Structure of Mechanically Agitated Gas-Liquid Contactors

Similar documents
Bioreactor System ERT 314. Sidang /2011

VISIMIX TURBULENT. LIQUID - SOLID MIXING. DEFINING JSS (JUST SUSPENSION SPEED)

VISIMIX TURBULENT. MECHANICAL CALCULATIONS OF A CONSOLE SHAFT

Energy Efficiency and Mixing Time Calculations in Mechanically Agitated Liquid Liquid Contactors

Bioreactor System ERT 314. Sidang /2012

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

Bubble Coalescence and Breakup in Gas-Liquid Stirred Tank Reactors

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

ENGG 199 Reacting Flows Spring Lecture 2a Blending of Viscous, Newtonian Fluids

Mixing in the Mechanically Agitated Bioreactor: A Matter of Being Stirred, not Shaken

VISIMIX LAMINAR. BLENDING OF NON-NEWTONIAN LIQUID. POWER. CIRCULATION. MIXING TIME.

SPECIFYING MOTIONLESS MIXERS

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

Tradition & Technology

Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor Using Single and Dual Impeller Configurations

CFD STUDY OF SLURRY HOMOGENIZER

Introduction to Pumps

CFD Simulation of Gas-Liquid in an Agitated Vessel

A Review on Hydrodynamics of Gas Inducing Mechanically Agitated Contactors.

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

Application of CFD for Improved Vertical Column Induced Gas Flotation (IGF) System Development

6. Positioning. 6.1 General description

Improving Conventional Flotation Methods to Treat EOR Polymer Rich Produced Water

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Development of a High Pressure, Oil Free, Rolling Piston Compressor

Use equation for the cylindrical section and equation or for the ends.

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Fire and Safety for Offshore drilling and production Ajey Walavalkar ANSYS Inc.

Third measurement MEASUREMENT OF PRESSURE

Gas-liquid flow characteristics study on the amino acid fermentation tank

The effect of back spin on a table tennis ball moving in a viscous fluid.

Liquid -Vapor. Contacting columns

CFD SIMULATION OF GAS-LIQUID HYDRODYNAMICS IN AERATED STIRRED TANK AZRI ABDULLAH. A thesis submitted in fulfillment of

Applied Fluid Mechanics

ME1251 THERMAL ENGINEERING UNIT IV AIR COMPRESSORS

Compressors. Basic Classification and design overview

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Experimental studies on the effect of the number of stages on the performance of an electrical submersible pump in two-phase flow conditions

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

ISS0065 Control Instrumentation Lecture 12

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC!

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

User s Guide. VisiMix LAMINAR. Simulation of Mixing-Related Processes for Chemical Engineers. Jerusalem

HYDRAULICS. H89.8D - Hydraulic Bench

Free Surface Flow Simulation with ACUSIM in the Water Industry

Liquid-Liquid Mixing in Stirred Vessels: A Review

AE Dept., KFUPM. Dr. Abdullah M. Al-Garni. Fuel Economy. Emissions Maximum Speed Acceleration Directional Stability Stability.

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

CFD SIMULATIONS IN AN INTERNAL CIRCULATION AIRLIFT OPERATING UNDER HOMOGENEOUS REGIME

Performance Testing of a High Capacity Compressor for a 20K 20W Cryocooler

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

Bioengineering RALF Advanced

Design a grit chamber for population with water consumption of 135 LPCD.

Energy and mass transfer in gas-liquid reactors.

Hub Bearings for Automobiles that Conserve Resources

CHEMICAL ENGINEERING TRANSACTIONS

Measurements of Gas-Liquid Mixing in a Stirred Vessel Using Electrical Resistance Tomography (ERT)

Study on Mixing Property of Circulation/Shear Coupling Mechanism-Double Impeller Configuration

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Module 15 : Grit Chamber. Lecture 20 : Grit Chamber

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Lab Problems. Lab Problems for Chapter Fluid Characterization by Use of a Stormer Viscometer L-1

VISIMIX TURBULENT. HEAT TRANSFER PROCESS IN A SEMIBATCH REACTOR

International Journal of Scientific & Engineering Research, Volume 5, Issue 4, April ISSN

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

How Inlet Conditions Impact Centrifugal Air Compressors

IMPROVING PLANT AERATION USING GAS INFUSION TECHNOLOGY

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

United States Patent (19)

Copyright Warning & Restrictions

ON THE DEGASSING KINETICS IN A LADLE EQUIPPED WITH A ROTATING IMPELLER ASSISTED THROUGH PHYSICAL MODELING

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Akasison Flow phenomena of a siphonic roof outlet

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Investigation of Suction Process of Scroll Compressors

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Copyright by Turbomachinery Laboratory, Texas A&M University

Hydraulic Evaluation of the Flow over Polyhedral Morning Glory Spillways

Copyright Warning & Restrictions

Figure 1 Figure 1 shows the involved forces that must be taken into consideration for rudder design. Among the most widely known profiles, the most su

The effect of two inclined circular plunging jets on air entrainment in an aeration tank

ELASTOMER PROCESSING

Selection of gas compressors: part 2

Oxygen mass transfer in a bubble column with non-newtonian fluids

Flowmeter Shootout Part II: Traditional Technologies

Chapter 2 Pump Types and Performance Data

Irrigation &Hydraulics Department lb / ft to kg/lit.

GROUTEC SCOTT VICKERS. Grouting Equipment

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

THE INFLOW OF UNWANTED AIR

Design Enhancements on Dry Gas Seals for Screw Compressor Applications

Stormy Phillips BASICS OF LEASE AUTOMATIC CUSTODY TRANSFER (LACT) SYSTEMS

Pure Process Latinoamerica S.A. de C.V. Distribuidor Exclusivo.

Transcription:

Structure of Mechanically Agitated Gas-Liquid Contactors 5 2 Structure of Mechanically Agitated Gas-Liquid Contactors 2.1 The vessel geometry The most commonly adopted geometry of a stirred gas-liquid contactor is an upright cylinder, which may have a flat bottom and open top in most mixing laboratory scale vessels, it normally has hemi-elliptical end plates at both ends in plant scale vessels to meet process and structure requirement as process equipment. In mixing studies, the standard configuration as shown in Fig. 2.1-1 has been widely adopted because that a great number of empirical correlations are available to estimate its hydrodynamics as well as other transport characteristics. Fig. 2.1-1 Standard configuration of a stirred vessel with single Rushton turbine impeller.

6 MULTIPLE IMPELLER GAS-LIQUID CONTACTORS For a pilot scale or small process proposes, a jacketed vessel equipped with single or dual impeller vessel is used quite often. Figures 2.1-2, and 3 depict examples of laboratory and pilot plant scale fermenters. For plant scale or large volume gas-liquid contactors, a multiple impellers design with higher aspect ratio as shown in Fig. 2.1-4 is employed to ensure better gas utilization and to reduce the structure cost. The recommended aspect ratio of the cylinder is known as 2.0~3.0, if the ratio exceeds this limit, it may cause vibration of the shaft which is harmful to the driving unit and sealing device. Internal heat exchange elements such as internal coil or baffle coil as shown in Fig. 2.1-4 is often used in large diameter tanks to replace the jacket to meet structure requirement. Fig. 2.1-2 Laboratory scale stirred vessel Fig. 2.1-3 Pilot scale fermenter Fig. 2.1-4 Industrial scale mechanically agitated gas-liquid contactor

Structure of Mechanically Agitated Gas-Liquid Contactors 7 2.2 The impeller The roles of impeller in mechanical stirred gas-liquid contactors are: (1) To disperse gas into bubbles (discontinuous phase) for creating more interfacial area; (2) To pump liquid which can generate circulation of fluids to accelerate mixing; (3) To create high shear and turbulence for promoting micro-mixing or transfer process; (4) To re-circulate bubbles and extend the residence time of gas within the system. A proper design and selection of impeller for the system is most critical for the gas-liquid contactors to have good hydrodynamics condition and well gas dispersion performance. Figure 2.2-1 shows the various impellers, which are commonly used in stirred gas-liquid contactors. They are further classified into radial flow (a, b and c) and axial flow (d, e, and f) impellers, depending on flow direction of the discharge stream from the impeller. (a) Rushton turbine (b) Curved blade Turbine (c) Concave blade Turbine (Smith Turbine) (d) 45 Pitched blade Paddle (e) Hydofoil impeller (f) Prochem Fig. 2.2-1 Different types of impeller used for gas-liquid system Among these disk turbines, the straight blade disk turbine (Fig. 2.2-1a Rushton turbine) was acknowledged to be one of the most efficient design for gas dispersion purpose. Because it can generate higher shear and strong trailing vortices, which can disperse the sparged gas without itself becoming flooded. Recent studies indicated that the Scaba turbine (Fig. 2.2-1d, also known as Smith turbine) can offer less power reduction due to aeration and also give higher gas handling capacity at same energy dissipation density. For more viscous liquids, or to accelerate liquid mixing, a pitched blade paddle impeller (as shown in Fig. 2.2-2) is often installed as the upper impeller to obtain higher liquid circulation.

8 MULTIPLE IMPELLER GAS-LIQUID CONTACTORS Fig. 2.2-2 Various impeller combinations in multiple impeller system The ideal size of the impeller for gas dispersion impeller is suggested to be one third to one half of the vessel diameter and the lowest impeller is generally located one impeller diameter above the bottom of the vessel. For tall vessels, a multiple impellers arrangement as shown in Fig. 2.1-4 is employed to allow complete dispersion of gas and optimal mixing of components within the system. In this case, the distance between impellers, at least a 1.5 impeller diameter is recommended to acquire a better performance. Fig. 2.2-3 The minimum height to install the lowest impellers The height of the lowest impeller from the bottom (denote as c in Fig. 2.1-1) is depended on the type of the impeller characteristic. For axial flow impeller, such as pitched blade turbine or pitched paddle impeller, at least 0.5D distance from the bottom is needed to have proper flow pattern of fluid flow. For radial flow type impeller, a minimum clearance of 0.5D is required as shown in Fig. 2.2-3.

Structure of Mechanically Agitated Gas-Liquid Contactors 9 2.3 The gas sparger It was often considered that the type of gas sparger can directly affect the initial size of the dispersed bubbles before the mechanism of gas dispersion of the impeller was well understood. Three basic types of gas sparger were used, namely, the porous sparger, the orifice or ring perforated sparger (as shown in Fig. 2.3-1a) and nozzle sparger (as shown in Fig. 2.3-1b, and c). The porous sparger has been used primarily in a non-agitation system, since it has a higher pressure loss, and the holes are tended to be clogged by dirt, this type of sparger is rarely used in large scale equipment. In laboratory or pilot scale gas-liquid contactors, perforated ring sparger is widely applied. The perforated ring is normally arranged below the impeller in the size of approximately three-quarters of the impeller diameter. The diameter of the holes should be at least 2-3 mm to avoid clogging and at least several downward facing larger holes are needed to drain for avoiding blockage of the holes by sediments. For plant scale gas-liquid contactors, the single or multi-nozzle sparger is popularly used because of its simple structure and low pressure loss. The position of the nozzle should be located centrally below the impeller or located at side balanced places with a guided ring For the cases in which no contamination problem exists. the self-induced type sparger design such as Woldhof type sparger (as shown in Fig. 2.3-1d) is used for sparging gas and also circulating liquid. (a) Ring parger (b) single nozzle sparger (c) Balanced nozzle sparger Fig. 2.3 Various types of gas sparger (d) Woldhof type self-induced sparger 2.4 Baffle An unbaffled vessel containing low viscosity liquid tends to swirl and generates undesirable vortex as shown in Fig. 2.4-1a. This undesirable swirling flow causes not only severe reduction in mixing efficiency, but also leads the dispersed bubbles to swirl to center core due to its centrifugal effect. These actions cause a severe surface aeration for the unbaffled system.to eliminate this swirling flow in a cylindrical vessel, installation of four

10 MULTIPLE IMPELLER GAS-LIQUID CONTACTORS 0.08T-0.1T width baffles as shown in Fig. 2.4-1b is recommended. The baffles promote up and down flow, which accelerates the liquid mixing of the entire system, however, it also increases the power drawn by impellers. The term, complete baffled refers the installation of proper number of baffles such that the power consumption of impeller reaches at plateau or a maximum level. For cylindrical vessel which its diameter is less than 3 m, four baffles with 0.08T-0.1T width are sufficient to give a complete baffled condition. For larger diameter vessel, more than four baffles may be required to attain a satisfied condition. Figure 2.4-2 illustrates various ways to install the baffles. Vertical baffles at wall as shown in Fig. 2.4-2a is very common for low or moderate low viscosity liquids. To prevent the existence of the stagnant region behind the baffles, baffles can be set away a clearance from tank wall as shown in Fig. 2.4-2b. An inclined baffle (as shown in Fig. 2.4-2c) is adopted for higher viscous liquid cases. The height of baffle is usually mostly top to bottom, but it may submerges beneath the free surface around 0.1T as shown in Fig. 2.4-3, if the process needs some degree of swirling induction. (a) without baffle (b) with four full baffle Fig. 2.4-1 Flow patterns in baffled and unaffled stirred vessels

Structure of Mechanically Agitated Gas-Liquid Contactors 11 (a) Vertical without clearance (b) Vertical with clearance (c) Inclined baffle Fig. 2.4-2 Baffle arrangement Fig. 2.4-3 Recommended submerged Height of the baffles For gas-liquid systems height and location of the baffles might severely affect the motion and distribution of the dispersed bubbles within the vessel as shown in Fig. 2.4.4 Fig. 2.4-4 Effect of baffle location on bubble Fig. 2.4-5 ndustrial scale mechanically stiired tank agitated gas-liquid contactor

12 MULTIPLE IMPELLER GAS-LIQUID CONTACTORS In a plant scale vessels, the baffles also may serve as heat transfer surface as Fig. 2.4-5. However, one should bear in mind that excess baffling may cause localizing flow which results in poor mixing of the system. 2.5 Stablizing devices To prevent vibration of the rotating shaft which causes extra loading on supporting bearing and sealing, bottom bearing as shown in Fig. 2.5-1 is offen recommended. In some cases, stablizing fin or ring as shown in Fig. 2.5-2 is attached beneath the impeller. By choosing the mass of the ring or fins, one can shift the critical rotational speed which can prevent further damage of supporting bearing and sealing. (a) end bearing Fig. 2.5-1 End bearing (b) stabilizer ring Fig.2.5-2 Type of Stabilizer fins (c) stabilizer fin