User Guide and Operating Manual

Similar documents
Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

M5400 Operators Manual

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Installation and Use Manual

Yoke Block Instruction Manual

Flow meter. bellow vaporizer. APL valve. Scavenging system

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

VAPOMATIC ANESTHETIC VAPORIZER

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Yoke Block Instruction Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

MicroVent 1 Dual Mode Veterinary Ventilator IPPV / HFOV

Medical Gas Control Panel

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Operation Manual Guillotine Cutter RC-5

GILMONT ACCUCAL FLOWMETERS

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

ACUC ۰ ROUTINE PROCEDURE

AUTOVENT 4000 VENTILATOR

Halsey Taylor Owners Manual STOP!

RG3100 and RG3100Ice Regulator System

MOBILE E TANK STAND INSTALLATION AND INSTRUCTIONS

3/8" Dr. Air Butterfly Impact Wrench

Halsey Taylor Owners Manual

Hallowell EMC Anesthesia WorkStation Operating Manual

SurgiVet Universal CDS 9000 Small Animal Anesthesia Machine Operation Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Installation/Care/Use Manual

PORTER INSTRUMENT COMPANY, INC.

Halsey Taylor Owners Manual

5 Channel Calibrator

92831 TEL: (714) FAX:

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

GAS ANESTHESIA SYSTEMS. Cat. No / 22100

Agilent 1220 Infinity II LC Mobile Upgrade Kit

CSA Sample Draw Aspirator Adapter Operator s Manual

Rev. B. Operating Instructions

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

AIR/OVER HYDRAULIC JACK 20 TON

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

IV-ANE. User s Manual. Anesthesia equipment for test animals. Petition

Models: C62/63/64-A/D

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Carter Option X Valve connector assembly. Maintenance manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model VR6 System. Installation, Operation & Maintenance

AND OPERATION INSTRUCTIONS

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Helium-Oxygen Blender

RK-IR Sample Draw Aspirator Adapter Operator s Manual

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

1 DRIVE INDUSTRIAL IMPACT WRENCH

92831 TEL: (714) FAX:

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Halsey Taylor Owners Manual

VERTICAL BLADDER TANK

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

INTENDED USE TECHNICAL SPECIFICATIONS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Service and Repair Manual

User's Manual. MixRite TF 10. Edition 05.08

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

RG2200 BC Integrated Octopus

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Product Information News

Anes Machine Use and Pre-use Check - CA1 focus

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

THE UNIVENTOR 400 ANAESTHESIA UNIT

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

Installation and Maintenance Manual. Compact Medical Gas Outlets

Float Operated Level Controllers

SOTR Special Operations Tactical Respirator

Welcome to the Specialized Medical Services Respiratory training webinar series!

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Model ASSEMBLY and OPERATING INSTRUCTIONS

Transcription:

User Guide and Operating Manual Table Top Laboratory Animal Anesthesia System 901806 & Mobile Laboratory Animal Anesthesia System 901807 / 901809 VetEquip, Inc. - Pleasanton, California USA - 800-466-6463

Table of Contents Table of Contents User / Owner Responsibility... 3 Receiving... 3 Guarantee... 4 Warnings and Cautions... 5 Equipment Descriptions... 6 Specifications... 7 Component Identification... 8-9 System Assembly... 10-12 Theory of Operation... 13 Operational Flowchart... 14-15 Pre-Operative Check & Operation... 16 Use Protocol... 17-18 Maintenance... 19 Web Site: www.vetequip.com E-mail: info@vetequip.com USA Toll-Free: 1-800-466-6463 International: +925-463-1828 VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 2

User/Owner Responsibility User/Owner Responsibility PLEASE READ THIS MANUAL BEFORE OPERATING THE ANESTHESIA MACHINE. The VetEquip Laboratory Animal Anesthesia System is for veterinary use only and is designed to function as specified when operated and maintained in accordance with the instructions supplied in this manual. This equipment must be periodically checked, calibrated, maintained and/or, components repaired and replaced when necessary for equipment to operate reliably. Parts that have failed in whole or in part, exhibit excessive wear, are contaminated or are otherwise unfit for use, should be immediately discarded and replaced. To maintain the warranty, replacement parts must be installed or supplied by VetEquip, Inc. Equipment that is not functioning correctly must not be used. This equipment must not be modified by unauthorized personnel or with unauthorized components. Receiving 1. Examine shipping carton for signs of external damage. Receiving 2. Unpack all items. Retain and store original shipping cartons and materials for use in the event this anesthesia machine must be shipped. 3. Inspect the anesthesia machine and accessories for any sign of damage that may have occurred during shipping. If damage is discovered, immediately file a damage claim with the carrier. Notify VetEquip of the claim, and we will do all we can to assist you. 4. Compare quantities received to quantities shown on packing list. Report any discrepancies to VetEquip immediately. 5. Complete the following information: Packed by: Date: / / Serial Number: Rec d by: Date: / / Serial Number verified: VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 3

Guarantee VetEquip s 100% Total Satisfaction Guarantee Guarantee VetEquip s philosophy on quality can be summed up in just 3 simple points: There is no room for mediocrity. You should never pay for anything less than premium products and services. The customer is the best judge of quality. This philosophy is more than just a credo; it dictates how we work. To demonstrate just how serious we are, we are pleased to extend to you our 100% Total Satisfaction Guarantee. What follows is the entire guarantee in all its simplicity. Read it as a reflection of the confidence we have in our quality equipment, dedicated support and outstanding service. Finally, a guarantee that let s you decide whether you re satisfied. Everything we sell is backed by a 100% 1-year money-back guarantee. Everything we sell is backed by a 100% 7-year unconditional replacement guarantee. If you are not fully satisfied and delighted with the VetEquip product or service furnished to you, just call us within 1 year of delivery and we will make arrangements to issue a full and prompt refund to you. If for any reason you become dissatisfied with your VetEquip product, at your request we will replace it without charge to you with an identical item or an item with comparable features and capabilities. That s it! Some guarantees guarantee products, some guarantee service and some have so much fine print, the only thing you re guaranteed is confusion. Ours is simple - only you decide when you re satisfied! Obtaining Warranty Service To obtain warranty service, contact us directly. Warranty service is FOB Pleasanton, CA. VetEquip, Inc. USA Toll-Free: 1-800-466-6463 P.O. Box 10785 International: +925-463-1828 Pleasanton, CA 94588-0785 Web Site: www.vetequip.com E-mail: info@vetequip.com What This Warranty Does Not Cover Damages or malfunctions caused by negligence, abuse, or use not in accordance with the operating manual. Defects or damages caused by unauthorized service or the use of other than VetEquip supplied parts. Parts of the anesthesia machine that require replacement under normal use, such as rubber or latex parts or components. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 4

Warnings and Cautions Warnings & Cautions For veterinary use only. Personnel operating this Laboratory Animal Anesthesia System must be thoroughly familiar with the instruction manual and equipment operation prior to use with patients. Tampering with the anesthesia system components by unauthorized personnel voids all warranties and specifications. The prevention of tampering with the anesthesia system is the sole responsibility of the user or owner. VetEquip assumes no liability for any malfunction, failure, damage or loss to either equipment or life. (Model 901809) Failure to open the APL (evacuation) valve with a patient attached to the absorber assembly could result in the death of the patient. Before using the anesthesia system, check that it is set up properly and ensure all connections and settings are correct. For the Model 901809, perform the 10 Second Leak Test as outlined in the Pre-operative Check section of this manual to verify the breathing circuit is leak-free. Always adhere to proper Diameter Index Safety System (D.I.S.S.) hose connections. Failure to comply will void your warranty and could compromise patient safety. If the oxygen flush button does not immediately return to the off position after being released or if the flow of oxygen does not immediately stop flowing from the common outlet after the oxygen flush button is released, remove the machine from service. The valve must be repaired by VetEquip or a VetEquip authorized service facility before using the machine. When turning off flowmeters, it is only necessary to turn the flow control knob clockwise until the ball float reaches the bottom of the tube. Excessive tightening will damage the valve seat, resulting in a leak requiring replacement of the valve. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 5

Equipment Descriptions Equipment Descriptions The Laboratory Animal Anesthesia System is designed for use with small animal models mouse to pig. Standard configuration includes a stand assembly with oxygen flowmeter, oxygen flush valve, precision vaporizer and a 10-foot oxygen hose assembly with threaded DISS connections. The standard system also includes a dual-procedure circuit; 2-liter induction chamber; breathing circuit with rat-size & mouse-size nose cones; and 2 activated charcoal filters for waste gas removal. Table-Top - 901806 Compact and versatile. This model uses only 8 x 11 of counter space. Weightbalanced handle and non-skid feet make this unit usable virtually anywhere. Mobile - 901807 Rugged and portable. This model utilizes sturdy casters and a built-in handle to allow easy movement between rooms or buildings. All internal connections are covered by a smooth panel, allowing easy cleaning. Mobile with CO 2 Absorber - 901809 A carbon dioxide absorber assembly has been added to the mobile system (above). Positive sealing gaskets and molded construction virtually eliminates leakage. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 6

Specifications All specifications are for standard systems. Operational Characteristics Table Top (901806) Mobile (901807) Mobile w/absorber (901809) Oxygen Flowmeter Volume: 0-4 liters per minute @ 55 psi. 0-4 liters per minute @ 55 psi. 0-4 liters per minute @ 55 psi. Oxygen Flush Volume: 15-35 liters per mintue @ 55 psi. 15-35 liters per mintue @ 55 psi. 15-35 liters per mintue @ 55 psi. Gas Supply: Oxygen male connector DISS Oxygen male connector DISS Oxygen male connector DISS Gas Pressure Requirements: 50-55 psi. 50-55 psi. 50-55 psi. Controls Flowmeter: Single-turn metering valve Single-turn metering valve Single-turn metering valve Oxygen Flush: Plunger-actuated, springreturn valve Plunger-actuated, springreturn valve Plunger-actuated, springreturn valve Adjustable Pressure- Limiting (APL) Valve: None None Three-turn metering valve Physical Properties W eight: A pprox. 32 lbs. (14.5 kg) A pprox. 56 lbs. (25.41 kg) Approx. 64 lbs. (29.03 kg) Dimensions: 11"w x 8"d x 14" h 19"w x 18"d x 50" h 22"w x 19"d x 50"h Base Footprint: 19"w x 18"d Material: Aluminum Frame; steel handle, bolts and screws; brass valves and tubing; acrylic flowmeter cover. Aluminum Frame, steel bolts and screws; brass valves and tubing; acrylic flowmeter cover; Delrin handle. Aluminum Frame; steel bolts and screws; injection molded polyurethane absorber head; brass valves and tubing; acrylic canister and flowmeter cover; Delrin handle and APL (evacuation) valve. Finish: Heat-treated enamel Heat-treated enamel Heat-treated enamel Prices, terms and product specifications are subject to change without notice. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 7 0801 - Rev. A

Component Identificaiton Oxygen Flowmeter Carrying Handle Table Top Laboratory Animal Anesthesia System Oxygen Flush Vaporizer Dial Vaporizer Common Outlet Flow Control Knob Table-Top Laboratory Animal Anesthesia System (LAAS) 901806 Induction Chamber Feed-Tube Evacuation Port Charcoal Filters Dual Breathing Circuit Breathing Circuit Stopcocks Nose Cone attachment site VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 8 Dual-Delivery Breathing Circuit Included with all Laboratory Animal Anesthesia Systems 991011

Component Identification Mobile Laboratory Animal Anesthesia System Syringe Holder Oxygen Flowmeter (A 2nd Flowmeter is optional.) Stainless Steel Instrument Shelf Vaporizer Handle & Hose/Circuit Hanger Oxygen Flush Button Common Outlet Mounting Holes for optional 2nd Vaporizer Attachment site for optional E-cylinder mounts CO 2 Absorber Assembly Mobile Laboratory Animal Anesthesia System (LAAS) 901807 INSET: Optional CO2 Absorber Assembly 901750 VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 9

System Assembly In order to quickly and properly set-up your Table Top or Mobile Laboratory Animal Anesthesia System, please complete each step of the Assembly Procedures below. If you have any questions, concerns or comments regarding the assembly of your system or with these instructions, please call us at 800-466-6463. Assembly STEP 1: (Fig. 1) Insert the clear fitting connected to the semi-transparent feed-tube of the Dual Breathing Circuit into either one of the Induction Chamber ports. Connect one end of the 22mm FlexHose to the remaining Induction Chamber port and the other end of the 22mm FlexHose to a Charcoal Filter. NOTE: (Fig. 2) The 22mm FlexHose can be cut to your desired length by cutting the hose at the ridge in the smooth junctions. Induction Chamber Ports Charcoal Filter with 22mm FlexHose connected Cut here Fig. 2 Fig. 1 Cut the FlexHose only at the ridge in the smooth junctions. Dual Breathing Circuit - Clear Fitting (semi-transparent feed-tube) STEP 2: (Fig. 3) Connect the second Charcoal Filter onto the 22mm FlexHose at the end of the Patient Breathing Circuit. Fig. 3 Charcoal Filter connected to Patient Breathing Circuit STEP 3: (Fig. 4a & 4b) Insert either the 9mm, 12mm or 14mm Cone into the Patient Breathing Circuit elbow fitting. Fig. 4a Fig. 4b 12/14mm Nose Cone 9mm Nose Cone VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 10

System Assembly Assembly Upon completion of STEP 3, the Dual Breathing Circuit Assembly should look similar to that shown in Fig. 5. Fig. 5 Dual Breathing Circuit connected to the Induction Chamber and Charcoal Filters. STEP 4: Insert the blue connector of the Dual Breathing Circuit into the Common Outlet of the machine. (see Fig. 6a for the Table Top LAAS and Fig. 6b for the Mobile LAAS). Fig. 6a (Table Top LAAS) - Insert the blue connector (black tubing) of the Dual Breathing Circuit to the Common Outlet. Fig. 6b (Mobile LAAS) - Insert the blue connector (black tubing) of the Dual Breathing Circuit to the Common Outlet. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 11

System Assembly STEP 5: Connect the gas supply hose assembly to the rear inlet DISS fitting of the Laboratory Animal Anesthesia System. Tighten gently with an 11/16 wrench on the hose fitting and a 5/8 wrench on the DISS inlet fitting. (see Fig. 8 for the Table Top LAAS and Fig. 9 for the Mobile LAAS). Assembly IMPORTANT: The other end of the DISS hose assembly must be connected to your tankmounted regulator or the outlet of your in-house O 2 supply line with an operating pressure of 55 PSI MAXIMUM. Pressure in excess of 55 PSI will cause damage to the Laboratory Animal Anesthesia System. DISS inlet - use 5/8 wrench Hose fitting - use 11/16 wrench Fig. 8 (Table Top LAAS) - DISS Hose Assembly connection. DISS inlet - use 5/8 wrench Fig. 9 Hose fitting - use 11/16 wrench (Mobile LAAS) - DISS Hose Assembly connection. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 12

Theory of Operation Theory of Operation An inhalation anesthesia system is designed to do the following: 1. Change a liquid anesthetic agent into a vapor. 2. Deliver that vapor to the patient in a precisely measurable amount. 3. Sustain the patient by delivering a metabolic gas in addition to the anesthetic vapor. 4. Capture all waste gas. 5. Channel the waste gas to an evacuation system such as an activated charcoal canister or a scavenging interface. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 13

Operational Flowchart 1. Oxygen flows from a pressurized tank that may be located on the anesthesia machine, in the room with the anesthesia machine, or in a remote area with the oxygen being piped through the walls. Operational Flowchart 2. A regulator is attached to the supply tank and reduces the pressure of the oxygen from as high as 2200 PSI down to a useable 55 PSI. 3. The oxygen flow reaches the anesthesia machine through the DISS connection and is then plumbed into two channels: a. One channel goes to the oxygen flowmeter. By using the flow control knob on the flowmeter, you further reduce the 55 PSI to a flow measured in liters per minute (LPM). b. The other channel goes to the oxygen flush valve. In the normal (closed) position, the flush valve has no flow through it. When the flush button is pushed, the oxygen flows directly into the patient circuit at a rate of approximately 15-35 LPM. This oxygen does not pass through the vaporizer. 4. The oxygen flow from the flowmeter is delivered to the inlet of the vaporizer. If the vaporizer is in the OFF position, the oxygen bypasses the vaporizer without picking up any anesthetic agent. If the vaporizer dial is turned to any position other than OFF, a precise concentration of vaporized anesthetic agent is delivered through the outlet of the vaporizer to the patient circuit. The vaporizer dial is adjusted by the operator and determines the amount of anesthetic agent vapor that will be added to the oxygen flow. The amount is measured as a percentage of the total flow and can be varied from 0-5%. 5. Lines from the vaporizer and the oxygen flush valve merge through the common outlet and into the dual procedure circuit. 6. Once the gas enters the dual procedure circuit, it is bifurcated by a Y-fitting into two branches. A stopcock within each branch of the circuit provides independent control of each branch. a. One branch goes to the induction chamber. When the stopcock to the induction chamber is open, the gases flow into the chamber through the feedtube. Turbulence circulates the anesthetic gases throughout the chamber until it exits through the evacuation port on the induction chamber, flowing passively through flexible evacuation tubing (FlexHose) and into a charcoal filter. b. The other channel goes to the patient breathing circuit. When the stopcock to the patient circuit is open, the gases flow to the nose cone of the breathing circuit. The gases then continue through the down-tube of the breathing circuit and into a second charcoal filter. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 14

Operational Flowchart Oxygen Supply (tank or house line) O 2 @ 2200 PSI Regulator Laboratory Animal Anesthesia System D.I.S.S. Hose O 2 @ 55 PSI Oxygen Flush Valve (normally CLOSED) Flowmeter O 2 @ 0 to 4 LPM Vaporizer O 2 + Agent Common Outlet 15-35 LPM with Flush Button Activated Dual Breathing Circuit Stopcock #1 Stopcock #2 Normal Flow with Oxygen Flush closed: 0-4 lpm of Oxygen and % Anesthetic Agent Charcoal Filter Induction Chamber (Patient) Flow with Oxygen Flush Activated: 15-35 LPM of Oxygen Nosecone Elbow Fitting Charcoal Filter Patient VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 15 0801 - Rev. A

Pre-Operative Check & Operation For veterinary use only. Personnel operating this Laboratory Animal Anesthesia System must be thoroughly familiar with the instruction manual and equipment operation prior to use with patients. Pre-Operative Check and Operation Tampering with the anesthesia system components by unauthorized personnel voids all warranties and specifications. The prevention of tampering with the anesthesia system is the sole responsibility of the user or owner. VetEquip assumes no liability for any malfunction, failure, damage or loss to either equipment or life. Always adhere to proper Diameter Index Safety System (D.I.S.S.) hose connections. Failure to comply will void your warranty and could compromise patient safety. 1. Ensure gas supply line for each gas is attached to appropriate D.I.S.S. inlet on back of the flowmeter(s). Connect gas supply hose(s) to in-house supply as necessary. 2. Ensure gas supply is turned on and is of sufficient quantity for the procedure(s). When turning off flowmeters, it is only necessary to turn the control knob clockwise until the ball float reaches the bottom of the tube. Excessive over-tightening will eventually lead to damaging of the valve seat, resulting in a leak at this point and necessitating replacement. 3. Test oxygen flowmeter for full range of operation by turning the control valve knob counter-clockwise to open and clockwise to close valve. Close valve when test is complete. 4. Test oxygen flush valve for performance by depressing and holding the button for 3 seconds. Oxygen should flush rapidly out of the common outlet. When the oxygen flush button is released, it should immediately return to the off position and the flow should immediately stop. If the oxygen flush button does not immediately return to the OFF position after being released, or if the flow of oxygen does not immediately stop flowing from the common outlet after the oxygen flush button is released, remove the machine from service. Have the valve repaired by calling VetEquip or a VetEquip-authorized service facility before using this machine. Before using the anesthesia system; check that it is set up properly, ensure all connections and settings are correct. For the Model 901809, perform the 10 Second Leak Test as outlined in the Preoperative Check section of this manual to verify the breathing circuit is leak-free. 5. Fill the vaporizer with the appropriate anesthetic agent. Refer to vaporizer instruction manual for complete instructions. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 16

Use Protocol Every facility should have in place an inhalation anesthesia protocol / SOP. The following is an outline from which you can begin to create your own. If you need assistance writing your protocol, please call us at 800-466-6463. Use Protocol 1. After checking to ensure your oxygen supply tank(s) is/are open and that you have sufficient gas pressure in the line(s) from the tank(s), assemble your system and check all connections for possible oxygen leaks. Oxygen tank to regulator (If oxygen is supplied from a free-standing tank) If any hissing is detected, check the condition of the gasket between the tank and regulator (E-cylinder only) and tighten the regulator onto the tank. Machine to dual delivery system This common outlet port is a friction-fit connection. Ensure connections made are leak-free. Dual delivery system to nose cone and chamber connection These are friction-fit connections. Ensure connections made are leak-free. Breathing elbow down tube and chamber outlet port to charcoal filters Connect tubing to charcoal filter to create a leak-free connection. For proper operation, the charcoal filter must be oriented vertically, ensuring the exit holes in the bottom are not obstructed. Filter canister holders are provided for this purpose. WARNING Standing filters directly on a surface will impede the airflow out the bottom of canister, rendering the filter useless and causing back pressure in the breathing circuit. 2. If required, fill the vaporizer with the appropriate liquid agent, according to instructions in the vaporizer manual. 3. Open the stopcock in the chamber tubing line. 4. Close the stopcock in the nose cone line. 5. Turn the oxygen flowmeter to at least one (1) liter per minute (lpm). 6. Place animal #1 in the induction chamber and secure the lid. NOTE You may place as many animals in the chamber as will fit comfortably. WARNING The chamber is airtight. If the oxygen flowmeter on the machine is turned off, there will be NO AIRFLOW into the chamber. NEVER leave animals in the chamber without an oxygen flow. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 17

Use Protocol Use Protocol 7. Turn the vaporizer dial to 2-2½%. Animal #1 should begin to lose consciousness within 2 minutes. 8. When Animal #1 has no response to rocking/jiggling the chamber, push the oxygen flush button for 20 to 30 seconds (for 2 liter chamber) to evacuate all anesthesia-saturated gas from the chamber. NOTE The brief oxygen flush evacuations of the chamber should not awaken already anesthetized animals. If the stopcock to the nose cone/mask is open when the oxygen flush button is depressed, the resulting oxygen pressure through the nose cone may push that animal s nose out of the nose cone. Always close the stopcock to the nose cone mask before using oxygen flush. 9. Open the stopcock in the nose cone line. 10. Immediately close the stopcock in the chamber tubing line. Open the chamber and remove Animal #1. 11. Place Animal #1 s nose in the nose cone. 12. Place Animal #2 in the chamber and open the stopcock in the chamber tubing line. 13. When the procedure on Animal #1 is complete, close the stopcock in the nose cone line and place Animal #1 in a recovery unit. That animal will begin to awaken in approximately 2 minutes. 14. Repeat steps 8 through 12 with Animal #2, and all remaining models, until all procedures have been completed. 15. Turn the vaporizer dial to the OFF position. 16. Turn off the oxygen flowmeter. 17. If a freestanding oxygen tank is used, turn off the oxygen at the tank. 18. Clean and sanitize the chamber and nose cone/mask as outlined in your procedure area cleaning protocols. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 18

Maintenance Maintenance Annual preventive maintenance and certification by qualified personnel is recommended to ensure proper operation. General upkeep and daily maintenance will enhance the longevity of your Lab Animal Anesthesia System. DO NOT USE PETROLEUM BASED LUBRICANTS. If you must use a lubricant, use only a silicone-based product. Stand Assembly: Do not use harsh or abrasive cleaners. Wipe with a damp cloth to clean. The stand is coated with a baked-on enamel that will withstand most cleaning/ disinfectant solutions. If a solution is to be used, it is recommended that you initially test its effect on an inconspicuous spot of the enamel. Flowmeter(s): Do not use harsh or abrasive cleaners. Plastic flowmeter covers may be removed and cleaned with a damp cloth. The exterior of the glass flowtube may be cleaned in the same manner. Should dirt or an obstruction get inside the flowtube, contact VetEquip for assistance. The flow control requires no maintenance. Oxygen Flush: This valve requires no maintenance. Rubber Goods: Rubber is a natural product and will deteriorate with age and use. All rubber goods are considered disposable and should be inspected daily for presence, condition and alignment. VetEquip, Inc. - Pleasanton, California USA - 800-466-6463 19