Tube Clamps Advanced Tube Clamps for the Most Demanding Applications

Similar documents
The Next Generation. Sani-Tech Ultra Tubing and Sani-Link Ultra Manifolds

BIOCLOSURE SYSTEM ASSEMBLIES

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

REACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

SmoothFlex Nominal Bore (SN) Dash Size

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

DuPont Kalrez PARTS AVAILABILITY LIST

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Model No Product Name Handpiece Only Complete System

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

Gemini Owner s Manual

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

ECHO INSTRUCTION GUIDE WARNING STATEMENT & INSTRUCTIONS Thank you for your purchase of the Echo Trigger. This product should be used only after

Hemorrhoid Multiple Band Ligator Set Instructions for Use

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

Research Grade Blood Pressure Transducer User's Manual

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

86BSD Backside Digital Output

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

BarbLock Handheld Pneumatic Assembly Tool

PACKER OPERATING PROCEDURES

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

SWAGELOK HOSES HOSE & FLEXIBLE TUBING SWAGELOK BANGALORE CHENNAI DELHI HYDERABAD

I have to say that I had no idea about compressors. That means it s easy for everybody.

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de CadĂȘncia Kadencesensor

1700ESL Kamvalok Coupler

ATEX ATEX

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Casing Spacer Technology Leaders

Corning Step-R. Repeating Pipettor. Instruction Manual

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Outback Inflatable SUP Board Owner s Manual

Installation and Operating Manual

Boreline Flexible Drop Pipe

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

TDUX Inflatable Duct Sealing System 1.0 General Product Information

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

Stainless Steel 142 mm Filter Holder YY

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

COSASCO MODEL 60 RETRACTABLE 1500 PSI SYSTEM RETRACTOR KIT Work Instruction

FLANGED TWO-PIECE BALL VALVES

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

QPF Pneumatic Fenders. Operation Manual A EUROTECH BENELUX COMPANY

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

CONTROL WITHOUT COMPROMISE

Adapter Kit 5WAR RA NT Y. For use with EZ-Up Gravity Boots and select Teeter Inversion Tables* NEW! Assembly Instructions FULL YEAR

MANUAL: Jumbo Siamese and Jumbo Wye

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

Model ASSEMBLY and OPERATING INSTRUCTIONS

Industrial Hose Products

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Manufacturers Crimp Guidelines Sure Seal Crevice Free Hose Couplings

VANDAL SUP OWNER S MANUAL

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Deep Submersible Level Transducer Series 300DS

User s Guide. CO2 Controller for miniature incubators

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Food Service Industry Hose

ROPV R40 E Series User Manual

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

Vessel Installation and Operating Manual

Laminating Technique for Face Adhesive Verification Transfer Adhesive

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

Tribomatic II Powder Pump

OPERATION MANUAL FOR VP 710E-3HM SERIES ALLIGATOR TUMBLE STIRRERS *US Patent # 6,176,609

Solstice Liquid Blowing Agent (LBA) and Solstice Gas Blowing Agent (GBA)

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Owner s Manual High Density Sports Storage Partial End Closure Accessory 32-inch Partial End Closure 48-inch Partial End Closure

Installation Instructions

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

FLANGED TWO-PIECE BALL VALVES

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

MSC Guidelines for Refrigeration Machinery

Success Paths: A Risk Informed Approach to Oil & Gas Well Control

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

Yoke Block Instruction Manual

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

THERMOPLASTIC HOSE INSTALLATION FACTORS

OPERATING MANUAL EASY-LOAD PUMP HEADS

COMPACT METAL bender 99826

Transcription:

www..accuflowsystems.com----ph:--240.457.4413 Tube Clamps Advanced Tube Clamps for the Most Demanding Applications

Standard Size Tube Clamps TC Pure-Fit TC Pure-Fit TC Tube Clamps represent a new generation of clamping technology for the pharmaceutical industry. They feature an outer body with no sharp edges, eliminating the potential for snags, scratches and punctures; a press-down locking system that is fully encapsulated to guard against untimely or unwanted release; a side release mechanism that facilitates secure, single-handed installation and operation; and an integral bore hole for absolute lock-out capabilities. Pure-Fit TC s innovative design allows for complete flow stoppage, and the clamp can be installed over the tube in the normal fashion or put together after the tube is already part of a completed assembly. Pure-Fit TC Characteristics Pure-Fit TC Tube Clamps are constructed from high performance thermoplastic materials (PVDF or polypropylene), and come in two standard sizes (3/8" and 3/4") to accommodate a wide range of tubing products. Pure-Fit TC Compatibility Pure-Fit TC Tube Clamps are autoclavable and sterilizable and meet all USP Class VI criteria. They have been physically tested to meet the most demanding applications. Pure-Fit TC Features/Benefits Provides complete fluid stoppage Smooth edges and corners help prevent punctures and ruptures Can be installed on or over tubing or finished assemblies High degree of leverage accommodates tubing with different durometers Can be utilized in the flow position Single-hand installation capability for ease of operation Unique top locking mechanism and side release prevent unwanted openings Integral bore hole for lock-out capabilities Available in PVDF or polypropylene Polypropylene is BPA-free; PVDF is both animal derivative-free and BPA-free Custom colors and identification available Autoclavable and sterilizable (autoclave not recommended for polypropylene clamps) Pure-Fit TC and TCL* Typical Physical Properties 1 Property Polypropylene PVDF Tensile Strength, psi (MPa) ASTM D638-91 4,800 (33.1) 6,300 (43.4) 2 Flexural Modulus, psi (MPa) ASTM D790-92 145,000 (999.7) 290,000 (1,999.5) Hardness (Shore D) ASTM D2240-91 72 78 Heat Deflection ASTM D648-82 ºF (ºC) @66 psi ºF (ºC) @264 psi 189 (87) 266 (130) 221 (105) Water Absorption (%) ASTM D570-81 0.01 0.03 Maximum Recommended Working Temperature ºF (ºC) * (PVDF only) 200 (93) 275 (135) 3 1 Squeeze to release. 2 Press down to lock. 3 Thread cable tie through bore hole for total lock out.

Large Tube Clamps Pure-Fit TCL Pure-Fit TCL Large Tube Clamps provide the same innovative clamping technology as Pure-Fit TC, but are designed to accommodate large diameter and thick wall tubing applications. Pure-Fit TCL is compatible with standard, braided (reinforced) and multilayer tubing. In addition to providing complete fluid stoppage, Pure-Fit TCL can be utilized in the flow position and features an integral bore hole for absolute lock-out capabilities. Pure-Fit TCL Characteristics Pure-Fit TCL is constructed from animal derivative-free and BPA-free PVDF. Pure-Fit TCL is available in two sizes to accommodate a wide range of thick wall tubing and can be used with up to 2.0" O.D. tubing. Pure-Fit TCL Compatibility Pure-Fit TCL is fully autoclavable and sterilizable and meets all USP Class VI criteria. Pure-Fit TCL Features/Benefits Compatible with large diameter, thick wall, reinforced and multilayer tubing Provides complete fluid stoppage Smooth edges and corners help prevent punctures and ruptures Can be installed on or over tubing or finished assemblies High degree of leverage accommodates tubing with different durometers Can be utilized in the flow position Integral bore hole for lock-out capabilities Available in PVDF PVDF is completely animal derivative-free and BPA-free Custom colors and identification available Fully autoclavable and sterilizable Pure-Fit TC and TCL Typical Applications Biopharmaceutical manufacturing Drug delivery and discovery Laboratory functions Pharmaceutical processes Medical systems Assemblies and tubing set Peristaltic pump sets Pure-Fit TC Selection Guide Part Number Material Tubing Range, O.D. (Inches) Minimum, Wall Section (Inches) PFTC375PP Polypropylene 1/8 3/8.030 PFTC375PVDF PVDF 1/8 3/8.030 PFTC750PP Polypropylene 3/8 3/4.060 PFTC750PVDF PVDF 3/8 3/4.060 Pure-Fit TCL Selection Guide Part Number Material Tubing Range, O.D. (Inches) Tubing Range, Wall (Inches) PFTCL150 PVDF 3/4 2 1/16 1/8 PFTCL250 PVDF 3/4 2 1/8 1/4

Pure-Fit TCL Clamping Properties The tests below were conducted using standard silicone tubing, Sani-Tech STHT-C-500-4 (0.5" ID x 0.75" OD x 0.125" wall) and Sani-Tech STHT-C-1000-6 (1.00" ID x 1.5" OD x 0.25" wall), and braid-reinforced silicone hose, Sani-Tech STHT-R-0500 (0.5" ID x 0.875" OD x 0.187" wall) and Sani-Tech STHT-R-1000 (1.00" ID x 1.375" OD x 0.187" wall). Position Telltale Stop Flow Flow Upper Member Gate Lower Member First Latch Cam Lever Red Push Button Locking Link STHT-C-500-4 0.5" ID x 0.75" O.D. x 0.125" Wall STHT-R-0500 0.5" ID x 0.875" O.D. x 0.187" Wall STHT-C-1000-6 1.00" ID x 1.5" O.D. x 0.25" Wall STHT-R-1000 1.00" ID x 1.375" O.D. x 0.187" Wall Pure-Fit TCL part number PFTCL150 (white) PFTCL250 (red) PFTCL250 (red) PFTCL250 (red) Clamp holding force Pressure Only, psi 56* 102.33 76.50 40 Pressure with Liquid, psi 55* 101.83 76.50 40 Drop testing of liquid-filled assembly from a distance of 5 feet Flow Position, Cam Lever Closed Pass Pass Pass Pass Stop Flow Position, Cam Lever Closed Pass Pass Pass Pass Stop Flow Position, Cam Lever Closed, Pressurized Pass Pass Pass Pass Average % free flow Free Flow, No Clamp 100% 100% 100% 100% Flow Position, Cam Lever Closed 100% 100% 76% 76% Stop Flow Position, Cam Lever Opened 100% 75% 53% 53% Stop Flow Position, Cam Lever Closed 0% 0% 0% 0% Flow rates, time to empty, sec. Free Flow, No Clamp 58.58 58.58 8.73 8.73 Flow Position, Cam Lever Closed 58.50 44.38 11.50 11.50 Stop Flow Position, Cam Lever Opened 58.55 58.57 16.47 16.47 Stop Flow Position, Cam Lever Closed No flow No flow No flow No flow * determined by tubing

How to Operate Pure-Fit TCL 1 Starting from the closed position, simultaneously press and hold the two Red Push Buttons. Red Push Button 2 While pressing the Red Push Buttons, pull the Cam Lever back toward the hinge of the clamp. Cam Lever Red Push Button Locking Link Pull the Lower Member away from the Locking-Link. Lower Member 3 Position the tube in the gate, as close as possible to the hinge of the clamp. 4 Push Lower Member to the desired position ( Flow or Stop Flow ). Rotate the Cam Lever to the closed position. 5 The tubing is now held in the Flow position or locked in the Stop Flow position (rendering shows Stop Flow position).

For more than four decades, and its family of companies have supplied the world with innovative, high-performance polymer products for the most demanding applications. Our tradition of excellence goes back almost 350 years through our parent company, Compagnie de, one of the world s top 100 industrial corporations, with operations in 64 countries. This successful corporation has been built with the single purpose of serving the customer and a commitment to quality and leadership in each of the industries served. biopharmaceutical products manufacturing facilities 700 Warner Blvd. Taunton, MA 02780 Tel: (800) 722-7106 Tel: (508) 823-7701 Fax: (508) 823-1438 2664 Gilchrist Road Akron, OH 44305 Tel: (800) 798-1554 Tel: (330) 798-9240 Fax: (330) 798-6968 4451 110th Avenue North Clearwater, FL 33762 Tel: (800) 541-6880 Tel: (727) 531-4191 Fax: (727) 530-5603 Grindwell Norton Ltd, Devanahalli Road, Off Old Madras Road, Bangalore, 560049, India Tel: +91 80 28472900 Fax: +91 80 280472616 460 Milltown Road Bridgewater, NJ 08807 Tel: (800) 435-3992 Tel: (908) 218-8888 Fax: (908) 218-9009 3910 Terry-Diane Street Beaverton, MI 48612 Tel: (888) 387-0067 Tel: (989) 435-9533 Fax: (989) 435-2355 La Mothe-aux-Aulnaies F-89120 Charny, France Tel: (33) 3-86-63-78-78 Fax: (33) 3-86-63-77-77 KK 10801-5, Haramura, Suwa-gun Nagano 391-0106 Japan Tel: (81) 266-79-6400 Fax: (81) 266-70-1001 www..accuflowsystems.com----ph:--240.457.4413 Consult a Sales Representative for the product and material formulation that best suits your specific application needs. www.biopharm.saint-gobain.com Pure-Fit is a registered trademark. Patent Number 7,434,779 B2 WARNING: The content of tubing materials is not certified by the FDA for implant devices and is neither designed nor intended to be used in medical applications involving permanent implantation in the human body or permanent contact with body fluids or tissues. Failure to comply with this warning may lead to serious bodily injury or death. 1234 Street Name City, State 01234 USA Tel: +1 (234) 567.8910 Toll Free: +1 (888) 123.4567 Fax: +1 (234) 567.8910 www.website.com IMPORTANT: It is the user s responsibility to ensure the suitability and safety of materials for all intended uses. Laboratory, field or clinical tests must be conducted in accordance with applicable requirements in order to determine the safety and effectiveness for use of materials in any particular application. If intended for medical use, it is the user s responsibility to ensure that the materials to be used comply with all applicable medical regulatory requirements. Limitation of Liability: Except for products for which (SGPPL) has established a specific written warranty, the products described herein are sold by SGPPL without any guarantee and/or warranty, oral or written. User assumes all risk, if any, including the risk of injury, loss or damage, whether direct, consequential or incidental, arising out of the use, misuse or inability to use these products. SAINT-GOBAIN PERFORMANCE PLASTICS DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NOTE: Corporation does not assume any responsibility or liability for any advice furnished by it, or for the performance or results of any installation or use of the product or of any final product into which the product may be incorporated by the purchaser and/or user. FLS-5118-0414-SGCS 2014