CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

Similar documents
ECS Protector Nitrogen Inerting Vent (PAV-WN)

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. Table 1 - Specifications

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

NGP-250/500 Nitrogen Generator Quick Start Guide

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Q = C v P S

Wet pipe low flow foam/water system

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA. Q = C v P S

OBSOLETE. Wet pipe low flow manifold system

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

VERTICAL BLADDER TANK

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

HORIZONTAL BLADDER TANK

TECHNICAL DATA OBSOLETE

Materials Performance November Nitrogen generator inhibits corrosion within fire protection systems

Potter Nitrogen Generators

TECHNICAL DATA ACCELERATOR MODEL E-1

MEDICAL EQUIPMENT CATALOG

2017 Award Nomination

CAPITAL CONTROLS SERIES NXT3000

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

DESIGN DATA. Dry 105a. September 5, 2008

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

INSTALLATION OPERATION MAINTENANCE

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION

Type 3 - PSA Nitrogen Generation System

Anti-flood device Model B-1

M-06 Nitrogen Generator (Nitrogen Making Machine)

Corrosion Protection in Dry-Pipe Systems Article and photos by Gregory Havel, except where noted. May 21, 2018

Piped Air SCBA Refilling System Standard

Data Sheet Issue A

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Corrosion in Fire Sprinkler Systems. Presenter: Josh Tihen Po.er Electric Signal Company

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

TECHNICAL DATA. Dry 132a. October 1, 2008

FIRE SPRINKLER PRODUCTS PRODUCT CATALOG

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Transferring and Storage

Bermad Pressure Reducing. Model: 42T

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

FIRE PROTECTION PRODUCTS

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

The Air Liquide Gas System Equipment Brochure

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

TECHNICAL DATA OBSOLETE

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

Rejuvenation Instructions

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

September 2018 Pressure Test

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

IH Report: SUFMO 08/09-CC21 1/27/2009 Stanford University Gas Cabinet Installation and Performance Criteria


Instructions for Installation, Operation, Care and Maintenance

Data Sheet Issue A

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Irrigation System Winterization and Pressurization Procedures

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Unique solutions for Oxygen and Nitrogen supply

/ /

TECHNICAL DATA OBSOLETE

Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Section GAS CHLORINATION SYSTEM

NGN Series nitrogen generator

Transcription:

CORROSION AT THE AIR-WATER INTERFACE There are three (3) physical attributes of oxygen that explain why almost all corrosion in wet pipe fire sprinkler systems occurs in close proximity to trapped air pockets: 1) Oxygen gas exhibits very low solubility in water 2) Once oxygen gas dissolves in water it reacts with steel in minutes 3) Oxygen gas dissolved in water has very poor mobility Trapped Air Pocket REMOVE THE GAS There is at least 5,000 times more oxygen available for corrosion in the trapped gas of a wet pipe fire sprinkler system than there is in the source water. Source water contains only 10 parts per million of dissolved oxygen which is 0.001% of water volume. Focusing on the very small amount of oxygen contained in the incoming water supply is costly, inefficient, and unproductive. Water (<1%) Trapped Gas (>99%)

SIMPLE AND SAFE CORROSION CONTROL Minimal equipment installation No chemical additives or coatings Solution for both new and existing systems INDUSTRY LEADING VENT EQUIPMENT Patented vent design requires no plumbing to drain with no leak risk Lightest weight, lowest profile redundant vent available Ability to inspect device functionality from the ground SUPERIOR CUSTOMER SERVICE AND PRODUCT SUPPORT Single engineer point of contact for every project Excellent lead times - maximum 72 hours from purchase order to shipment Project commissioning and training available with every nitrogen project PROVEN RESULTS Long term wet pipe nitrogen inerting case histories since 2010 Officially recognized solution by NFPA and FM Global Similar technology used to control corrosion in other industries for decades SIGNIFICANT COST AND RISK REDUCTION CASE STUDY: Mission Critical Aerospace Manufacturing Twenty-five (25) wet pipe systems protecting 1 million square feet Extensive pipe failure history; averaged 1 pipe leak every 2 weeks All systems flushed and inerted with nitrogen in 2010 One (1) recorded leak since systems were inerted No extensive pipe or full system replacement required CASE STUDY: Large Covered Mall Thirty-six (36) wet pipe systems protecting 1.2 million square feet Mall opened in 2001; averaged multiple pipe leaks per month Repaired existing pipe leaks and inerted with nitrogen in 2012 One (1) recorded leak since systems were inerted No extensive pipe or full system replacement required

WHAT IS WET PIPE NITROGEN INERTING (WPNI)? WPNI is a process that displaces oxygen, which causes corrosion, with nitrogen gas inside wet pipe fire sprinkler systems. Any trapped gas remaining in the system after the WPNI process is not corrosive. The process of using an inert gas provides a higher level of protection against corrosion when compared to only using automatic air vents because it is nearly impossible to remove all trapped oxygen from a wet pipe fire sprinkler system, even when multiple vents are installed. WHAT EQUIPMENT IS REQUIRED FOR WPNI? Three (3) essential components are needed: 1) An integral venting device to remove oxygen installed at a remote accessible high point 2) A nitrogen injection port installed at the sprinkler riser 3) A source of nitrogen gas - either nitrogen cylinders or a nitrogen generator Nitrogen Inerting Vent installed at remote accessible location Nitrogen Injection Port installed at sprinkler riser, nitrogen gas supplied from high pressure cylinder or nitrogen generator in applications with many sprinkler systems Typical WPNI System Configuration - equipment installed at two locations WHY IS A VENT NEEDED FOR WPNI? 1) The vent provides a remote location to exhaust oxygen gas from system piping after filling with nitrogen which facilitates gas mixing within system piping. 2) The vent provides an integrated gas sampling port to verify nitrogen concentration at the remote portion of the sprinkler system during the WPNI process. 3) The vent prevents false alarms and improves hydraulic performance in the system by automatically exhausting trapped gas from the sprinkler system as it fills with water. 4) The vent acts as a failsafe; in the event that a nitrogen atmosphere is not maintained the vent still provides a an automatic mechanism for removing trapped oxygen from the sprinkler system.

ECS Ejector Automatic Air Vent (PAV-W) Patented redundant design means no plumbing to drain Pressure gauge monitors primary float valve Optional electronic monitoring Rated up to 175 psig FM Approved Specifications System Connection: 1/2 MNPT Dimensions: 14 (L) x 7 (D) x 5 (H) Weight: 7 lbs. ECS Protector Nitrogen Inerting Vent (PAV-WN) Required for Wet Pipe Nitrogen Inerting (WPNI) Includes nitrogen injection port Patented redundant design means no plumbing to drain Pressure gauge monitors primary float valve Optional electronic monitoring Rated up to 175 psig FM Approved Specifications System Connection: 1/2 MNPT Dimensions: 14 (L) x 7 (D) x 5 (H) Weight: 8 lbs. ECS Ejector Riser Air Vent (PAV-R) For venting gas in riser assemblies Redundant design means no plumbing to drain Compatible with wet pipe nitrogen inerting (WPNI) Pressure gauge monitors primary float valve Rated up to 175 psig Specifications System Connection: 1/2 MNPT Dimensions: 12.75 (W) x 7 (D) X 15 (H) Weight: 16 lbs.

ECS In-Line Corrosion Detector (ILD) Only device that provides continuous real-time corrosion monitoring of a fire sprinkler system UL Listed Matches size, schedule, and material of system piping Provides 360 surface area to detect internal corrosion Thin wall section monitored by UL Listed/FM Approved pressure switch Includes remote test station, can be monitored remotely and with fire alarm or building automation systems ECS Protector Handheld Gas Analyzer (PHGA-1) Handheld battery powered device verifies nitrogen purity during wet pipe nitrogen inerting (WPNI) process Measures gas concentration at vent sampling port Features one button self-calibration Nitrogen Inerting Start-up Kit (NISK-1) Essential components for wet pipe nitrogen inerting (WPNI) 3/8 kink resistant rubber hose rated for 300 psig Industrial grade nitrogen cylinder regulator rated for 3000 psig Industrial grade brass couplers Ensures nitrogen gas is safely transferred from nitrogen cylinder to fire sprinkler system At least one (1) In-Line Corrosion Detector recommended per project In-Line Corrosion Detector typically installed on wet system branch lines at air/water interface One (1) Handheld Gas Analyzer recommended per WPNI project At least one (1) Nitrogen Inerting Start-up Kit recommended per WPNI project, multiple kits recommended for projects with many sprinkler systems to decrease time required for WPNI

Nitrogen Inerting Vent Installed on Remote Sprinkler Main and In-line Corrosion Detector Installed on Branch Line at Air/Water Interface Permanent High Capacity Nitrogen Generator, Air Compressor, and Storage Tank Provides Plant Nitrogen to Fire Sprinkler System Riser Air Vent Installed in Riser Check Valve Port Below Clapper

PAV-W Automatic Air Vent PAV-WN Nitrogen Inerting Vent Designed for Overhead Sprinkler Systems PAV-R Riser Air Vent Designed for Sprinkler Riser Assemblies Removes Corrosive Trapped Oxygen Redundant Float Valve Design (1) Visual Indicator for Primary Valve (2) Supports Wet Pipe Nitrogen Inerting Includes Nitrogen Injection Port FM Approved Meets NFPA 13 Vent Requirement (1) Patented design prevents water discharge and does not require plumbing to drain (2) PAV-W and PAV-WN visual indicator can be viewed from the floor up to 20 feet below CONTACT US Contact ECS Monday thru Friday, 8 AM - 5 PM (central time zone) to have a project specific quote returned in four (4) business hours or less. Your project will be reviewed by an ECS engineer to ensure the most cost effective solution is provided. (314) 432-1377 sales@ecscorrosion.com