Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

Similar documents
Touch Screen Guide. OG-1500 and OG Part # T011

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Safety Manual VEGAVIB series 60

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Connect with Confidence NO POWER NO PROBLEM

Supplementary Operator s Manual 42/24-14 EN Rev. 3

frequently asked questions

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Typical Wayside Reader System Quotation

Residential Ultrasonic Gas Meters

User manual CF8-D/W-IN

Safety Manual VEGAVIB series 60

Product Overview. Product Description CHAPTER

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

CCT-7320/ROC-2313 Reverse Osmosis Controller

EWC EARLY WARNING CONTROL OPERATIONAL PRESENTATION. Charles Dickens (757)

RPS900W Redundant Power Supply. Installation Guide.

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Safety Manual OPTISWITCH series relay (DPDT)

LENNOX SLP98UHV DIAGNOSTIC CODES

XC2 Client/Server Installation & Configuration

AGW SYSTEMS. Blue Clock W38X

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

Ultima. X Series Gas Monitor

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Description of Device Parameters Proline Prowirl 200 HART. Vortex flowmeter. Products Solutions Services. Main menu Language.

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Datasheet: K-30 ASCII Sensor

E L E C T R O N I C S X T

[CROSS COUNTRY SCORING]

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

DeZURIK. KSV Knife Gate Valve. Safety Manual

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

A4s Operation Manual

LT GasAnalyzer beyond standards

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

CASE STUDY. Compressed Air Control System. Industry. Application. Background. Challenge. Results. Automotive Assembly

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

Protec P3000 (XL) Helium Sniffer Leak Detector

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

Autocalibration Systems For In Situ Oxygen Analyzers

Operating instructions Capacitive sensor KIA (M30) / / 2010

Minimum standard of competence for electro-technical officers (STCW Reg III/6) Electrical, electronic and control engineering at the operational level

Pressure Sensor Bridge Configurations

GUIDELINES FOR VESSELS WITH DYNAMIC POSITIONING SYSTEMS ***

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

BUBBLER CONTROL SYSTEM

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

theben Continuous valve actuator CHEOPS drive CHEOPS drive As of: Jul-11 (Subject to change without notice) Page 1 of 41

The elegant solution for enhanced security. Manual Attack Resistance. Ballistic Resistance. Recyclable product. Eco-design. exit

Wind Plant Operator Data User's Guide

Electrical, electronic and control engineering at the operational level

[CROSS COUNTRY SCORING]

Operating instructions Capacitive sensors KG AC (M18) / / 2010

Alimak Lift Control, ALC II User s Manual

PROCEDURE. April 20, TOP dated 11/1/88

Questions & Answers About the Operate within Operate within IROLs Standard

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Roller AC Servo System

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

This Manual Part recommends functional/operating guidelines for control of automatic grade crossing warning systems. Draft

X-dock Software History

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

SIDRA INTERSECTION 6.1 UPDATE HISTORY

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

DTG - LCD Digital Temperature Gauge USER MANUAL

Safety manual for Fisher GX Control Valve and Actuator

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Design Envelope Booster. Sequence of operation

SDX Submersible Depth Transmitter User Manual

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

M-06 Nitrogen Generator (Nitrogen Making Machine)

Electronic Turbine Meter TERZ 94

GasSense NDIR User Manual

D-Case Modeling Guide for Target System

CompacSas BA. Comfort and design for high-security access

New Thinking in Control Reliability

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Airflow Options for Cisco MDS 9396S SAN Switch

Requirements for Reduced Supervision of Power Plants, Thermal Liquid Heating Systems, and Heating Plants

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

REASONS FOR THE DEVELOPMENT

300C/ 800C/ 990C Plus Series

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

RESOLUTION A.817(19) adopted on 23 November 1995 PERFORMANCE STANDARDS FOR ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEMS (ECDIS)

Lecture 04 ( ) Hazard Analysis. Systeme hoher Qualität und Sicherheit Universität Bremen WS 2015/2016

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Confidence comes with knowing you are Code-Ready.

Bidirectional Forwarding Detection Routing

Grantek Systems Integration

SonoMeter 30 Energy Meters

Transcription:

4.0 COMPONENT FEATURES AND REQUIREMENTS An AEI site should include the following component subsystems: Presence detector Wheel detector Tag reader Controller Communications Power supply Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1. Comm Link To External Systems I Comm Link Main Contro ller Tag Reader 'Presence Detector I Wheel Detector 6 ell Power Supply Surge Protection Power Source Fig. 4.1 AEI site components 08/2014 K-III [RP-9203.V1.0] 317

RP-9203.V1.0 4.1 Presence Detector Subsystem 4.1.1 Detect Start of Train The AEI site should sense and report when a train enters the AEI site's read range. To reduce power consumption and extend the life of the equipment, much of the equipment should be in standby mode, or even powered down, when not in use. The presence detector is one means for the AEI site to detect a train in time to turn on the train movement and tag reading subsystems and start the read without missing any tag reads or axle counts. 4.1.2 Detect End of Train The AEI site should sense and report when a train exits the AEI site's read range. The AEI site cannot build the final consist for a train until the entire train has passed through and exited the AEI site's read range. With no train in range, the train movement and tag reading subsystems can return to standby mode. 4.2 Wheel Detector/Train Movement Subsystem See paragraph 2.2.1.1, "Capture Train Movement Data." For purposes of allocating functionality, some "train movement" processing is hosted on the controller component. Ideally, the wheel detector/train movement subsystem will have sufficient redundancy to correctly detect and build consists even when it has a faulted sensor. The AEI site wheel detector/train movement subsystem should function in both directions and be compliant with each movement type of the S-9203A movement status criteria. 4.2.1 Count Axles The AEI site wheel detector/train movement subsystem should count axles on trains passing through the AEI site's read range. The wheel detector is the main driver of the train movement subsystem. Although newer ways of counting wheels are emerging, wheel detectors have traditionally been made of a magnetic sensing system that is able to detect when a wheel passes over it. The sensor is traditionally mounted to the flange side of the rail just under the clearance of the wheel with its connecting cable run in the gravel of the track bed. 4.2.2 Direction 4.2.2.1 The AEI site wheel detector/train movement subsystem should determine the direction of travel for trains passing through the AEI site's read range. 4.2.2.2 Reversing Direction The AEI site wheel detector/train movement subsystem should not double-count axles when trains stop and/or reverse direction while passing through the AEI site's read range. Note: This implies correct function at very low speeds. 4.2.3 Speed The AEI site wheel detector/train movement subsystem should determine the speed of trains passing through the AEI site's read range. K-III [1113-9203.V1.0] 318 08/2014

RP-9203.V1.0 4.4.2 Data Evaluation 4.4.2.1 Car Recognition The AEI site-controller subsystem should use the train movement data to identify, at a minimum, the following types of cars. To further clarify the requirements for car type, refer to the Universal Machine Language Equipment Register (UMLER): 4- and 6-axle locomotives Standard 4-axle railcars Standard 6-axle railcars Articulated and fixed drawbar railcars Amtrak Other commuter-type railcars RoadRailer equipment Specialty equipment 4.4.2.2 Data Reconciliation The AEI site-controller subsystem should reconcile the train movement data and the AEI tag data, assembling a full consist that conforms to Standard S-9203A (latest version). 4.4.2.3 Error Reporting The AEI site-controller subsystem should flag any errors or inconsistencies identified in reconciling the tags read with the train movement data. For instance, if a tag is in error and reports too few axles, the known physical model of the axle count of the train must be used to indicate a problem in the tag. 4.4.3 Data Caching The AEI site-controller subsystem should cache consist reports for a desired minimum of 200 trains to allow for data recovery as well as power and communication outages. This feature will also allow users to recover data that was lost or not collected. 4.4.4 Secure Access See paragraph 5.2, "Security Requirements." 4.4.5 Data Reporting The AEI site-controller subsystem should assemble and provide consist reports to external entities that provide the correct password. See paragraph 2.2.1.4, "Report Consists." 4.4.5.1 Pushing Consist Reports The AEI site-controller subsystem should push consist reports to a list of predefined recipients within 5 minutes of identifying that a train has passed. That list of predefined recipients may be determined by consist information, such as the train operator, cargo, or errors detected. 4.4.5.2 Responding to Consist Report Queries The AEI site-controller subsystem should construct and push consist reports in response to queries from authorized external systems that provide the correct password. 4.4.5.3 Train Reporting and S918A Compliance The AEI site-controller subsystem should construct consist reports that comply with the requirements of Standard S-9203A (latest version). K-III [RP-9203.V1.0] 320 08/2014

4.4.6 Maintenance Functions 4.4.6.1 Maintenance Reporting and S-9203A Compliance The AEI site-controller subsystem should provide maintenance reports that comply with the requirements of Standard S-9203A (latest version). Specific requirements of Standard S-9203A include, but are not limited to, the following: Functional maintenance reporting with designated intervals established Individual message adherence to preset percentages, accuracy, and descriptiveness of actual event Triggering a message, independent of the predetermined interval, upon request Validation of time synchronization Complete reports, utilizing selected displays, AHM, EMS, and EOC 4.4.6.2 Fault Reporting The AEI site-controller subsystem should alarm fault indications, including but not limited to fatal and warning conditions, sensor faults and failures, loss of a communication link, loss of primary power, and UPS status, to a predefined external entity. This feature will allow users with administrative access to respond promptly to faults, thereby improving availability. 4.4.6.3 Remote Diagnostics The AEI site-controller subsystem should provide remote diagnostics, indicating when the AEI site system or any component thereof is in need of service and how it should be serviced. This feature will allow users with administrative access to identify and troubleshoot faults remotely, thereby reducing maintenance costs. Ideally, the remote diagnostics will function when the controller subsystem is not in a defined normal operating condition. 4.4.7 Remote Configuration The AEI site-controller subsystem should support remote configuration by users with appropriate access. 4.4.7.1 Multiple Configurations The AEI site-controller subsystem should support a minimum of eight separate user configurations. 4.4.7.2 Configurable User Parameters The AEI site-controller subsystem should allow users with the correct password to modify user-specific parameters including, but not limited to, site number or ID, delimiters, reported time, track orientation/designation, password, report filtering criteria, and report delivery address(es). Users may specify that they receive consist reports for all trains or only for trains that satisfy specific criteria such as size, direction, or car type. Users must identify the IP address(es) and/or phone numbers to which consist reports will be sent. 08/2014 K-III [RP-9203.V1.0] 321

4.4.7.3 Configurable Administrative Parameters The AEI site-controller subsystem should allow users with the correct password to modify site-specific parameters, including, but not limited to, system time, user configurations, diagnostic thresholds and reporting address(es), consist report hold time, alternate communications links, and default track identification. User configuration includes adding, deleting, and modifying user names and passwords. The tag-reader subsystem needs to be told how many tracks and in what configuration it is dealing with. These privileges are reserved for the owning road of the site. 4.4.7.3.1 Passwords The AEI site should support adding, deleting, and modifying user names and passwords. 4.4.7.3.2 Track Orientation The AEI site should support setting its track orientation to E-W, W-E, N-S, or S-N. Note: This determines the train travel direction reported for the consist. 4.4.7.3.3 Site Health Check Report Interval The AEI site should support setting how often a health check report is generated to its owning host system. 4.5 Communications Subsystem The AEI site communications subsystem should support multiple communication paths from the site controller to external clients, including, but not limited to, IP Networks and modem connections from 2400 baud to 56 KB. In this context, support means to be able to utilize multiple communication paths if they are provided. The available communication paths will be site-specific. 4.5.1 Secondary Communication Paths The AEI site communications subsystem should be capable of automatically switching to a secondary communication path if the primary communication path is inoperative or unavailable. 4.6 Power Supply Subsystem The AEI site power-supply subsystem should provide sufficient power to operate the AEI site equipment, except for heaters and air conditioners, for a minimum of 6 hours in the absence of primary power. AEI sites must have an uninterruptable power supply that will last long enough for a technician to remedy a "typical" power outage. Battery backup is the norm, but solar or other hybrid solutions are acceptable. 4.6.1 UPS Status Reporting The AEI site power-supply subsystem should report to the controller subsystem its status, including, but not limited to, prime power availability and remaining operating time. 4.7 Surge Suppression Subsystem An AEI site must provide the protection of its sensitive electronic equipment from high electrical surges. Presumably, this takes the form of Faraday shielding and surge suppressors on I/O paths. All possible surge paths must be protected. All but direct lightning strikes to the site must be guarded against meaning that a nearby lightning strike on the track may not bring the site down. Sites that can handle a direct strike are preferred as long as the direct hit protection is not cost prohibitive. See paragraph 4.4.7.3.1, "Surge Suppression." 4.7.1 Input/Output Protection The AEI site subsystem should protect all sensor, data, communication, and power inputs and outputs. 08/2014 K-III [RP-9203.V1.0] 323