Garrett Gas Train Instruction Manual

Similar documents
INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID

Garrett Gas Train. Part No Instruction Manual. Updated 5/10/16 Ver. 4.0

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 5/26/2009 Ver. 2.0

Aging Cell, OFITE Style. Included Items

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

600 o F High Temperature Aging Cell Instruction Manual

Model VR6 System. Installation, Operation & Maintenance

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

High Temperature Aging Cell Instruction Manual. Manual No , Revision F

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Operation Manual Piston Sensed Gas Pressure Regulators

Installation, Operation, and Maintenance Manual

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

PRESSURISED PAINT CONTAINER

GILMONT ACCUCAL FLOWMETERS

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Lost Circulation Material Evaluation Receiver Instruction Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

LRS(H)4 Pressure-Reducing Regulator User Manual

HT4700 HPHT Filter Press Instruction Manual Manual No. D , Revision A Instrument Part Nos: , , ,

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Calcimeter Instruction Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Pressure Dump Valve Service Kit for Series 2300 Units

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

TEST SPECIFICATION NYT-909-C

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

V-24 OXYGEN LANCE VALVE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Installation, Operation, and Maintenance Manual

Helium-Oxygen Blender

CART FOR CENTURION 1500+

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

3/8" Dr. Air Butterfly Impact Wrench

Adjustable. Unloader Valve. O&M Manual. Part #

DBML-60/80 Squeeze Tool

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

TECHNICAL DATA CAUTION

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

DynaPak 2000L System Support Manual Version

4400 TwinHybrid Gas Seal

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

RG1200 Service and Repair Manual

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

1200B2 Series Service Regulators. Instruction Manual

Installation, Operation, and Maintenance Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Installation, Operation, and Maintenance Manual

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

UltRo Dual Flow Reverse Osmosis Water System

Instruction Manual Updated 6/22/06 Ver. 2.0

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Booster Pump PB4-60 Replacement Kits

RD(H)20/25 Pressure-Reducing Regulator User Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

FOR SAFE AND CORRECT USE

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Installation and Service Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

HPB25 Hydraulic Paving Breaker

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

AIR/OVER HYDRAULIC JACK 20 TON

Model PSI Compressor with 3-Gallon Air Tank 12VDC

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Flow meter. bellow vaporizer. APL valve. Scavenging system

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

1800C and 1800C-HC Series Service Regulators

DS05C,D,G Dial Set Pressure Regulating Valves

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

OPERATING INSTRUCTIONS

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Purge Star & Ring Purge Systems

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Transcription:

Garrett Gas Train Instruction Manual Part No. 552010001EA Rev. C

TABLE OF CONTENTS SECTION PAGE NO. 1 Introduction...1 2 Safety Considerations...3 3 Procedure for Gas Train Analysis (Sulfides - Water Based Fluids)...5 4 Procedure for Gas Train Analysis (Sulfides - Oil Based Fluids)...9 5 Procedure for Gas Train Analysis (Carbonates)...13 6 Cleaning and Maintenance...17 7 Equipment and Specifications...19 8 Pressure Regulator Maintenance...23 9 Parts List...25 TABLE 1 Draeger Tube Identification, Sulfide...7 2 Draeger Tube Identification, Carbonates...15 FIGURE 1 Garrett Gas Train (Sulfides Analysis water based drilling fluids)...4 2 Garrett Gas Train (Sulfides Analysis oil based drilling fluids)...8 3 Garrett Gas Train (Carbonates Analysis)...11 4 Model 337 Pressure Regulator (Exploded View)...22

SECTION 1 INTRODUCTION A number of gases are generally present in the drilling fluid during the drilling operation. Two of these gases may be identified and their concentration determined using the Garrett Gas Train. These are undesirable gases but their presence and concentration are important. These two gases are Hydrogen Sulfide (H 2 S) and Carbon Dioxide (CO 2 ). The presence of Hydrogen Sulfide Gas is important because it is toxic and dangerous to human health. It is a health hazard in concentrations in air as low as 20 parts per million. Hydrogen Sulfide can be fatal in higher concentrations. The Garrett Gas Train analyses can warn of the risk of increasing concentrations of sulfides in drilling fluid and possible release of Hydrogen Sulfides into the atmosphere. The presence of Carbon Dioxide (CO 2 ) in the drilling fluid is important because it can cause severe corrosion and damage to the drilling rig equipment. Measurement of the concentrations of carbonates permits calculation of treatment necessary for corrosion control. The Garrett Gas Train separates the gases from liquids, thereby preventing contamination of the H 2 S or CO 2 detecting Draeger tubes by the liquid phase. A Draeger tube is the preferred H 2 S detector for quantitative sulfide analysis. A Draeger tube responds to H 2 S by progressively darkening along its length as the H 2 S reacts with the reagent. NOTE: A hydrogen sulfide test paper disk can be accommodated in the Garrett Gas Train for routine tests until evidence of the presence of H 2 S is noted by discoloration of the hydrogen sulfide test paper, then a Draeger tube should be used for quantitative analysis. Total soluble sulfides include the sulfide (S = ) and bisulfide (HS) ions. Two types of Draeger tubes are used to adequately span the range of hydrogen sulfide concentrations that may be found in water based drilling fluid filtrates and in oil based drilling fluids. The low-range Draeger tube, H 2 S 100/a, is white until H 2 S turns it brownish-black. The high-range Draeger tube, H 2 S 0.2%/A, is pale blue until H 2 S turns it jet black. No known common drilling fluid component or contaminant causes this coloration of the Draeger tubes as does H 2 S. The Draeger tubes change color by reacting to a given quantity of H 2 S therefore the length of the darkened section of the tube depends not only on the concentration of the sample gas but also on the flow rate and the length of time the sample flows through the Draeger tube. To relate the divisions on the Draeger tube to the parameters of the Garrett Gas Train, a tube factor for each tube has been calculated. Refer to Table 1 for the tube factors to be used to calculate the hydrogen sulfide concentration and Table 2 for the tube factor for the carbonate concentration. For H 2 S in Oil-Based drilling fluids, the same two Draeger tubes are used as for water based drilling fluid. The technique of running the analysis is modified to analyze the oil drilling fluid instead of the filtrate in order to capture all the "active sulfides". Active sulfides are typically the neutralization products of H 2 S and lime plus any un-reacted H 2 S. Utilizing a weak acid in the Garrett Gas Train, the oil drilling fluid test liberates H 2 S gas from active sulfides but not from inert sulfides. Whole drilling fluid is used in this test rather than the filtrate.

The concentration of soluble carbonates in the water based drilling fluid filtrate can be determined by the following method. Total soluble carbonates include carbon dioxide (CO 2 ), the carbonate (CO 3 ) and bicarbonate (HCO 3 ) ions. Drilling fluid filtrate is acidified in The Garrett Gas Train, converting all carbonates to CO 2 which is then evolved by bubbling an inert gas through the sample. The gas stream is collected in a one liter bag and subsequently drawn through a Draeger tube at a fixed flow rate. The CO 2 Draeger tube responds to the CO 2 passing through it by progressively staining along its length as the CO 2 reacts with a chemical which causes a crystal indicator to turn purple. The stain length is sensitive to the amount of CO 2 present, but it also responds to the CO 2 distribution, total volume, and flow rate of gas passed through the tube.

SECTION 2 SAFETY CONSIDERATIONS Safe operation of the Garrett Gas Train requires that the operator be familiar with the proper operation and potential hazards associated with pressurized equipment. Pressurizing the Garrett Gas Train Cell, even though it is to a low pressure, poses the potential hazards of the cell or associated pressurization equipment leaking and/or releasing sample gas or pressurizing gas which could cause serious injury. Several precautions that should be observed are listed below: Usually Carbon Dioxide is the choice of pressurizing gas when running Sulfides analysis. Nitrous Oxide (N 2 O) or Nitrogen must be used for the Carbonates analysis. Never connect the Garrett Gas Train to any other gas. If Nitrogen is used it must be supplied from an approved Nitrogen gas cylinder. Nitrogen Cylinders must be secured and meet all safely standards. Refer to Section 9E (first four items) for the optional equipment required for Nitrogen connection. Carbon Dioxide and Nitrous Oxide are normally supplied in small cartridges which contain about 900 psi (6206 kpa) pressure. They are primarily used for pressurization. Do not allow these cartridges to be heated or exposed to fire. They can explode if overheated. Maintain pressure regulators in good condition. Never use oil on pressure regulators. Leaking pressurization systems should be repaired or replaced. Gauges, fittings and hoses should be kept in good condition and leaks should be found and corrected. Refer to REGULATOR REPAIR, Section 8. Periodically test the safety relief valve attached to the regulator. Never plug or bypass this safety valve. When preparing to pressurize the Garrett Gas Train Cell always make sure the regulator is closed (Tee screw backed all the way out, counterclockwise). Hydrogen Sulfide (H 2 S) smells like rotten eggs. Prolonged exposure to this gas will deaden a persons sense of smell and the person will assume the danger is over when in fact the Hydrogen Sulfide concentrations may be higher and the person may be in very serious danger. CAUTION WHEN COLLECTING (H2S) SAMPLES FOR THE GARRETT GAS TRAIN, USE EXTREME CAUTION TO AVOID BREATHING ANY HYDROGEN SULFIDE. USE AN APPROVED BREATHING MASK OR BREATHING AIR BACK PACK.

Fig. 1 - GARRETT GAS TRAIN SULFIDES ANALYSIS WATER BASED DRILLING FLUIDS (Numbers refer to Sections 9A through 9D PARTS LIST)

SECTION 3 PROCEDURE FOR GAS TRAIN ANALYSIS (SULFIDES - WATER BASED DRILLING FLUIDS) A. Set Up For Water Based Drilling Fluid Filtrate, Sulfides. (Refer to Fig. 1). If it is not known that CO 2 gas was used in the last test, the regulator, tubing, and dispersion tube should be purged with CO 2 gas for two minutes. NOTE If is desired to run the sulfides test using a hydrogen sulfide test paper disk instead of the Draeger tube, fit the test disc under the O-ring of Chamber 3 of the Garrett Gas Train. The hydrogen sulfide test paper, although not preferred for quantitative analysis, will show the presence or absence of sulfides in the sample, and under proper test conditions (flowing CO 2 for fifteen (15) minutes can provide an estimate of the amount of sulfides when compared to a Hach color chart. Install the 3 in. (7.6cm) tube in place of the Draeger tube in Chamber 3 and connect the tube to the flowmeter to it. Omit steps A-6, A-7, B-6, and B-7 below. 1. Be sure the gas train is clean, dry, and on a level surface, with the top [13] removed. 2. Add 20 ml deionized water to Chamber 1. (Refer to Fig. 1). 3. Add 5 drops W-300 octanol defamer to Chamber 1. 4. Assemble the top [13] onto the gas train body [12] using the four thumb screws [14]. Make sure the "O" rings [27, 28] have properly sealed by noting flattened tops all the way around "O" ring circumference. 5. Adjust the dispersion tube [7] in Chamber 1 to approximately 0.5 cm above the bottom. 6. Select the proper Draeger tube for the expected concentration of sulfides. (Refer to Table 1, for sample volumes, and selection of Draeger tube range). 7. Apply Lubriseal onto the 7 mm diameter of both ends of Draeger tube Beak the tips off both ends of the Draeger tube by inserting the tips in the hole in bracket [44] near the bottom of chamber 1. With the arrow on the Draeger tube pointed upward, insert Draeger tube [33 or 34] into the loosened connector [15] on top of Chamber 3 until first line on scale is level with the top of the connector. Tighten tubing connector nut hand tight. Fit the Tygon tube [25] from the flowmeter inlet fitting [22] onto top of Draeger tube. 8. Make sure the Luer Cap [16] is secured on the sample inlet Luer Fitting [17]. 9. Back out the regulator tee screw [5] until it turns freely. 10. Install and puncture the CO 2 cartridge [32], or open the supply pressure, if Nitrogen is being used. 11. Adjust the regulator to 5 psi. (34 kpa) or gauge [21]. NOTE: Do not attempt to pressurize higher than 10 psi. (69 kpa). 12. Adjust needle valve [6] for a flow of 0.3 to 0.5 liters/minute read on flowmeter [29].

13. Flow CO 2 carrier gas for 15-seconds to purge air from the system. Check the system for leaks as described below. 14. Close the discharge at the top of the flowmeter [29] by fitting a piece of Tygon Tubing [25] over the barbed insert [24] and plugging or pinching the tubing to seal it closed. 15. Verify approximately 5 psi pressure on gauge [21], back out the Tee Screw on the regulator [5] until it turns freely to shut of the carrier gas supply. 16. Allow the system to remain pressurized approximately 5 minutes and observe the gauge reading. If less then 3 psi, use soap solution to determine source of leak. 17. If pressure test is passed, remove tubing plug and readjust regulator to about 5 psi. 18. Shut off the CO 2 carrier gas at the needle valve [6]. B. Sample Analysis The estimated concentration of soluble sulfides will determine the volume of filtrate that will be required. (Refer to Table 1). Care should be taken during drilling fluid sampling, filtration, and analysis to avoid extensive exposure of sample to the air because sulfides are rapidly lost by air oxidation. 1. Using an API Low Temperature / Low Pressure Filter Press, run a filtration test on a sample of the water based drilling fluid to be analyzed and collect a sufficient volume of solids-free filtrate for analysis. (Refer to Table 1 for volume required). 2. Using a 10 ml hypodermic syringe [30], inject the required volume of solids-free filtrate sample into Chamber 1 through the top injection port [8]. 3. Using a clean syringe, slowly inject 10 ml sulfuric acid solution into chamber 1 through the injection port [8]. Gently shake the gas train to mix acid with sample in Chamber 1. CAUTION MOISTURE IN THE TRAIN CAN CAUSE THE BALL IN THE FLOWMETER TO FLOAT ERRATICALLY AND MAY AFFECT THE ACCURACY OF THE DRAEGER TUBE READING.

4. Immediately restart the CO 2 carrier gas flow by turning the needle valve [6] to a steady flow of about 0.3 liters/minute as read on the flowmeter for 4 minutes for paper disc Sulfide/ no Sulfide test. One cartridge is sufficient for either size Draeger tube and should provide 15 to 20 minutes of charge at 0.3 liters/minute flow rate. If the hydrogen sulfide test paper disks are used, three to four tests can be made with one cartridge, but the paper disc should not be used more than three or four times. For any quantitative test, the full 15 minutes must be run. 5. Observe changes in appearance of the Draeger tube. Before the front starts to smear, note and record the maximum darkened length (in units marked on the tube). Although the front may attain a diffuse and "feathery" coloration, continue flowing for a total of 15 minutes. If sulfites are present in the sample, an orange color (caused by SO 2 ) may appear in the high-range tube ahead of the black front. When recording darkened length, the orange SO 2 region should be ignored. 6. When de-pressurizing, shut off the supply pressure by closing the two shut off valves [6] on the CO 2 manifold. If a Nitrogen system is being used, close the cylinder valve. Bleed the system of pressure, then, back out the regulator Tee screw. 7. Using the measured sample volume, the Draeger tube's maximum darkened length, and Draeger Tube Factor from Table 1, calculate sulfides in the sample: 1 TABLE 1 Draeger Tube Identification-Sample Volume & Tube Factor for Various Sulfide Ranges Sulfide Range (mg/l) Sample Volume (ml) Draeger Tube Identification (See Tube Body) Tube Factor (Used In Equation) 1.2 to 24 10.0 2.4 to 48 5.0 H 2 S 100/a 0.12* 4.8 to 96 2.5 60 to 1020 10.0 120 to 2040 5.0 H 2 S 0.2%/a 1500** 240 to 4080 2.5 * Tube Factor "0.12" applies to new style tubes, H 2 S 100/a (catalog no. CH-291-01), with calibration marks from 100 to 2000. Older style tubes with 1 to 20 scale use a Tube Factor of 12. ** Tube Factor "1500" applies to new style tubes, H 2 S 0.2%/a (catalog no. CH-281-01), with calibration marks 0.2 to 7.0. Older style tubes with 1 to 17 markings still use a Tube Factor of "600" times the ratio: "Batch Factor"/0.40. (A "Batch Factor" was stamped on boxes of old style tubes; there is not a "Batch Factor" for new style tubes.)

Fig. 2 - GARRETT GAS TRAIN SULFIDES ANALYSIS OIL BASED DRILLING FLUIDS (Numbers refer to Sections 9A through 9D PARTS LIST)

SECTION 4 PROCEDURE FOR GAS TRAIN ANALYSIS (SULFIDES - OIL BASED DRILLING FLUIDS) A. Set Up Of The Garrett Gas Train For Oil Based Drilling Fluid, H 2 S Analysis. (Refer to Fig. 2). If it is not known that CO 2 gas was used in the last test, the regulator, tubing, and dispersion tube should be purged with CO 2 gas for two minutes. 1. Be sure the gas train is clean, dry, with the top [13] removed. Set the body [12] of the Garrett Gas Train on the magnetic stirrer [36], positioning the center of chamber 1 over the center of the stirrer. Place the stirring bar [37] in chamber 1. (Refer to Fig. 2). 2. Add 20 ml of citric acid/demulsifier/isopropyl alcohol solution to Chamber 1 (Refer to Fig. 2). 3. Add 10 drops W-300 octanol defamer to Chamber 1. (Refer to Fig. 2). 4. Assemble the top [13] onto the gas train body [12] using the four thumb screws [14]. Make sure the "O" rings [27, 28] have properly sealed, by noting a flat portion in "O" ring profile all around the circumference of ring. 5. Adjust the dispersion tube [7] in Chamber 1 to be slightly above the liquid level in that chamber by loosening and tightening connector [15]. 6. Select the proper Draeger tube [33 or 34] for the expected concentration of sulfides. (Refer to Table 1, for sample volumes and selection of Draeger tube range.) 7. Apply Lubriseal onto the 7mm diameter of both ends of Draeger tube. Break the tips off both ends of the Draeger tube by inserting the tips in the hole in bracket [44] near the bottom of chamber 1. With the arrow on the Draeger tube pointed upward, insert Draeger tube [33 or 34] into the loosened connector [15] on top of Chamber 3 until first line on scale is level with the top of the connector. Tighten tubing connector nut hand tight. Fit the Tygon tube [25] from the flowmeter inlet fitting [22] onto top of Draeger tube. 8. Make sure the Luer Cap [16] is secured on the sample inlet Luer Fitting [17]. 9. Back out the regulator tee screw [5] until it turns freely. 10. Install and puncture the CO 2 cartridge [32], or open the supply pressure, if Nitrogen is being used. 11. Adjust regulator to about 5 psi (35 kpa) on gauge [21]. Then adjust needle valve [6] for a flow of 0.3 to 0.5 liters/minute on flowmeter (29). 12. While keeping the dispersion tube [7] "frit" above the liquid level in chamber 1, flow CO 2 carrier gas for 15-seconds to purge air from the system and check for leaks. (Refer to section 3-A step 13-17), then shut off the CO 2 carrier gas at the needle valve [6].

B. Sample Analysis The estimated concentration of soluble sulfides will determine the volume of oil base drilling fluid that will be required. (Refer to Table 1, "Sample Volume ml). Care should be taken during sampling and analysis to avoid extensive exposure of sample to the air because sulfides are rapidly lost by air oxidation. 1. Load a 10 ml syringe without needle [30] with a sample of the oil based drilling fluid to be tested. The size of this sample will be as determined from Table 1 plus 0.1 ml of excess sample. The excess sample (0.1 ml) compensates for the hold-up volume inside the injection fitting. 2. Wipe the outside of the syringe to clean off any oil base drilling fluid that is on it as a result of filling the syringe. Especially clean the area on the tip where the syringe will connect to the injection fitting. 3. Remove the cap [16] from the sample inlet Luer Fitting [17] on the side of chamber 1. 4. Connect the loaded hypodermic syringe to the syringe Luer fitting by inserting and turning 1/4 turn to the right. (Refer to Fig. 2) 5. Turn on the magnetic stirrer [36]. Adjust its speed of the stirring bar [37] until a vortex in the fluid is formed then carefully lower the gas dispersion tube [7] into the liquid to a point just above the rotating stirring bar [37]. Be careful not to let the dispersion tube hit the stirring bar. 6. Very slowly inject the sample from the syringe then lock the syringe closed with the syringe lock clip [35]. Increase the stirring speed to improve dispersion and to prevent the oil drilling fluid from sticking to the walls of Chamber 1. Continue the stirring about one minute. 7. Restart the CO 2 carrier gas flow by turning the needle valve [6] to a steady flow of about 0.3 liters/minute as read on flowmeter [29] for 15 minutes. A second cartridge may be required for the full 15 minutes. 8. Observe changes in appearance of the Draeger tube [33 or 34] which will begin at the inlet end (lower end). Note and record the maximum darkened length (in units marked on the tube) before the front starts to "feather" and smear. Although the front may attain a diffuse and "feathery" coloration, continue flowing for a total of 15 minutes. If sulfites are present in the sample, an orange color (caused by SO 2 ) may appear in the high-range tube ahead of the black front. When recording darkened length, the orange SO 2 region should be ignored. 9. Using the measured sample volume (not including the 0.1 ml hold up volume), the Draeger tube maximum darkened length, and Draeger Tube Factor (Table 1), calculate sulfides in the oil drilling fluid sample. 2

Fig. 3 GARRETT GAS TRAIN (CARBONATES ANALYSIS WATER BASED DRILLING FLUIDS (Numbers refer to Sections 9A through 9D PART LIST

SECTION 5 PROCEDURE FOR GAS TRAIN ANALYSIS (CARBONATES) If it is not known that N 2 O gas was used in the last test, the regulator, tubing, and dispersion tube should be purged with N 2 O gas for two minutes. A. Set Up Of The Garrett Gas Train For Water Based Drilling Fluid Filtrate, Carbonates Analysis. (Refer to Fig. 3). 1. Be sure the gas train is clean, dry, and on a level surface, with the top [13] removed. 2. Add 20 ml deionized water to Chamber 1. 3. Add 5 drops W-300 octanol defamer to Chamber 1. 4. Assemble the top [13] onto the gas train body [12] using the four thumb screws [14]. Make sure the "O" rings [27 and 28] have properly sealed by noting flattened tops all the way around "O" ring circumference. 5. Adjust the dispersion tube [7] in Chamber 1 to approximately 0.5 cm above the bottom. 6. Apply Lubriseal lubricant to and insert the 5/16" X 3" long plastic tube [43] into the tubing connector [15] on top of Chamber 3. Tighten the connector nut hand tight. 7. Make sure the Luer Cap [16] is secured on the sample inlet Luer Fitting [17]. 8. With regulator Tee Handle [5] backed off, install and puncture an N 2 O cartridge [38]. 9. Adjust regulator to about 5 psi (35 kpa) on gauge [21]. Then adjust valve [6] for a flow of 0.3 to 0.5 liters/minute as read on flowmeter [29]. (For maintenance instructions for regulators, Refer to Section 8 and Fig. 4). 10. Flow N 2 O for a 10-second period to purge air from the system. Check for leaks. Refer to Section 3-A, steps 13-17. Shut off the N 2 O carrier gas at the needle valve [6]. 11. Connect the gas bag [40] and stopcock [42] to the hand pump [41] using tubing [25]. Start with the bag essentially empty. Fully depress and release the hand pump. When the bag is completely empty and free of leaks, the pump will remain depressed for several minutes. If leakage is detected, check the pump and all connections. To check the pump alone, insert a sealed Draeger tube [39] into the pump opening and depress bellows. It will remain depressed if the pump does not leak. 12. With the bag fully collapsed, close the stopcock and disconnect the pump. Install the flexible tubing [25] from the stopcock and bag onto the top barbed tubing connector of the flowmeter [24]. 13. Using an API low temperature filter press and standard filtration procedure, collect a sufficient volume of solids-free filtrate for analysis. B. Sample Analysis 1. Using one 10 ml syringe and needle [30], inject a measured volume of solids-free filtrate sample into Chamber 1 through the top injection port [8]. (Refer to Table 2, for using estimated concentration of CO 2 to determine sample volume). 2. Using another 10 ml syringe and needle, slowly inject 10 ml sulfuric acid solution into Chamber 1

through the injection port [8]. Gently shake the gas train to mix acid with sample in Chamber 1. 3. Open the stopcock [42] on the gas bag [40]. Restart and adjust the gas flow by turning the needle valve [6] to a steady flow of 0.1 liters per minute as read on flowmeter [29] for 10 minutes. This will fill the gas bag with 1 liter of gas. At the end of 10 minutes, shut off gas flow by closing valve [6] and close the stopcock [42]. Immediately proceed to next step. 4. Apply Lubriseal to 7mm diameter at both ends of the tube. Break off the tips of both ends of the Draeger tube [39] by inserting the tip in the hole in the bracket [44] near the bottom of chamber 1. Remove the tubing [25] from flowmeter barbed tubing connector [24] and install it onto the upstream end of the Draeger tube. Observe that an arrow on the Draeger tube indicates gas flow direction. Attach the Draeger tube hand pump [41] to the downstream end of Draeger tube [39]. 5. Open the stopcock [42] on the bag [40]. With steady hand pressure, fully depress hand pump [41]. Release pump so that gas flows out of bag and through the Draeger tube. Operate the pump and count the strokes until the bag is empty. (10 strokes should empty the bag. The need for more than 10 strokes indicates leakage has occurred and test results will not be correct. 6. Using the measured Sample Volume, the Draeger Tube's Stain Length, and Tube Factor from table 2, calculate total soluble carbonates (CO 3 + HCO 3 ) in the filtrate sample, using the equation below: GGT Carbonates, mg / l = (Stain Length) x (2.5) (Sample Volume, cm ) 3 3

TABLE 2 Draeger Tube Identification-Sample Volume & Tube Factor for Carbon Dioxide Ranges Carbonate Range (mg/l) Sample Volume (ml) Draeger Tube Identification (See Tube Body) Tube Factor (Used In Equation) 25 to 750 10.0 CO 2 100 a 2.5 50 to 1500 5.0 250 to 7500 1.0 Tube Factor "2.5" applies to new style tubes, CO 2 100/a (catalog no. 1801811), with calibration marks IN PARTS PER MILLION BY VOLUME. Older style tubes (CH-308-01 are scaled to use a 25,000 Tube Factor.

SECTION 6 CLEANING and MAINTENANCE To clean the Gas Train, adjust the pressure regulator [5] counterclockwise until the pressure on the diaphragm is released. Remove the Draeger tube [33, 34 or 39], the plastic tube [43] from connector [15] on the top above chamber 3. Remove Gas Train Top [13] by loosening the four thumb screws [14], then remove dispersion tube [7] from the top above chamber 1. Using a soft brush, wash out all the chambers with warm water and mild detergent. Use a pipe cleaner to clean the passages between chambers. Wash, rinse, and then blow out the dispersion tube with a dry gas. Rinse the unit with deionized water and allow to drain dry. Inspect the "O" rings for cuts, hardening or flat spots. Make sure the "O" ring grooves are clean. Inspect the flowmeter [29] for contamination and/or sticking of the ball. If required the flowmeter may be dissembled from the gas train cover [13] by removing screw [2]. The plug in the top of the flowmeter can be removed to gain access to the ball and the tube bore. Using a soft brush, wash all graduates, syringes and other laboratory containers with warm water and mild detergent. Wash, rinse, and then blow out the dispersion tube [7] with a dry gas. For maintenance of the pressure regulator [5] refer to Section 8.

SECTION 7 EQUIPMENT AND SPECIFICATIONS The apparatus, laboratory supplies, and reagents listed are required to perform one or more of the three analyses utilizing the Garrett Gas Train. A. Equipment required for all tests. 1. Garret Gas Train apparatus, shown in Figs. 1, 2, and 3, consists of: Transparent plastic gas train Chamber 1 on regulator [5] and gauge [21] side of Gas Train. Chambers 2 & 3 Passages between chambers 2. Pressure Regulator Assembly Pressure Regulator Pressure gauge Needle valve (bleed valve) Depth 3.54 in. (90mm) Diameter 1.52 in. (39mm) Depth 3.54 in. (90mm) Diameter 1.18 in. (30mm) 0.08 in. (2mm) High pressure - Low flow, Chrome plated 30 psi (207 Kpa), dial 1.5 in. (38 mm), chrome plated 1/8 in NPT, Chrome plated Relief valve Adjustable 5-25 psi (34.5-172.5 Kpa) Pressure Source CO 2 or N 2 O cartridges 3. Flowmeter Floating-ball, Plastic body 0.06-0.5 LPM (60-500 cm 3 per minute) air 4. Hypodermic syringe 10.0 ml glass or plastic (inert to oil based drilling fluids) Luerlok. 5. Dispersion Tube PYREX glass Stem length Stem diameter Frit Frit Diameter 7.1 in. (180 mm) 0.315 in. (8.0 mm) Medium porosity Diameter 1.18 in (30 mm) 6. Graduated cylinder (not shown) 25 ml TC. Glass 0.2 ml divisions, +/- 0.2 ml

B. Equipment required for Sulfides in water base drilling fluid in addition to that listed in "A" above. 1. Inert carrier gas supply CO 2 cartridges 2. Detector Draeger tubes [2] Hydrogen Sulfide Test Paper Disks Draeger tube, low range Draeger tube, high range 3. Sulfuric acid 5N, reagent grade 4. W-300 Surflo Octanol defoamer Dropper bottle Marked H 2 S 100/a (No. CH-291-01), 100 to 2000 PPM Marked H 2 S 0.2%/A (NO. CH-281-01), 0.2 % to 7.0% C. Equipment required for Sulfides in oil base drilling fluid in addition to that listed in "A" above. 1. Magnetic Stirrer w/stirrer Bar* 1/4 inch (0.63 cm) diameter x 1 inch (2.54 cm) long stirring bar, coated with glass or TEFLON.* 2. Inert carrier gas supply CO 2 cartridges 3. Detector Draeger tubes [2] Draeger tube, low range Draeger tube, high range Marked H 2 S 100/a (No. CH-291-01), 100 to 2000 PPM Marked H 2 S 0.2%/A (NO. CH-281-01), 0.2 % to 7.0% 4. Demulsifer Citric acid/demulsifer/isopropyl alcohol solution 5. W-300 Surflo Octanol defoamer Dropper bottle * (Optional equipment with this instrument) D. Equipment required for Carbonates in water base drilling fluid in addition to that listed in "A" above. 1. Draeger CO 2 -analysis tube Marked CO 2 100/a (No. 1801811) 2. Draeger Alcotest gas bag. One-liter 3. Draeger Multigas Detector Hand-operated vacuum pump, Model 31 4. Stopcock (2-way bore), 8 mm glass 5. Sulfuric acid 5N, reagent grade 6. W-300 Surflo Octanol defoamer Dropper bottle 7. N 2 O gas cartridges Nitrous Oxide gas inert to Carbonates

NOTE Nitrogen (N 2 ) bottle with a low-pressure regulator can be used for both sulfides and carbonates. It can be connected to the Garrett Gas Train as follows: 1. Remove pipe plug [1]. (Refer to Figs. 1, 2 & 3) 2. Replace plug with (33513) 1/8 NPT x Eastman adapter. 3. Connect Regulator (34265) to a nitrogen cylinder such as (34005). 4. Connect (31700) 3 ft. hose from regulator to Eastman Adapter.

Fig. 4 - MODEL 337 PRESSURE REGULATOR (EXPLODED VIEW)

SECTION 8 PRESSURE REGULATOR MAINTENANCE A. Pressure Regulator Maintenance and Repair Most regulator troubles are caused by leaking fittings or faulty pins and seats. Rarely does a diaphragm rupture. If regulator will not hold pressure, check the fittings which are screwed into it. This is done by applying pressure to the system and looking for escaping gas in the form of bubbles. There are two methods of doing this. One method is to apply soap suds to the fitting areas, the other is to carefully immerse all but the pressure gauge in a container of water. If leaks are apparent, disassemble and apply tape thread sealant to the threads. B. Replacing the seat and pin. CAUTION DO NOT USE OIL BASED THREAD DOPE OR OIL IN ASSEMBLING ANY REGULATOR. If regulator connections do not leak, the seat and pin probably need replacement. Use the following procedure. (Refer to items on Fig. 4). 1. Using a wrench on the hex of the spring case, unscrew the spring case. All parts down to and including the diaphragm will remain in the spring case. 2. Remove the thrust plate. 3. Unscrew the retainer and remove the seat with the pin. 4. Clean and inspect the regulator for evidence of dirt or drilling fluid in the regulator body. An outlet filter (33720) is available to prevent this problem. 5. Replace the pin and seat. 6. Re-assemble the regulator. C. Verify the relief valve will relieve at 12-14 psi (88-96 kpa) pressure. Periodically test the safety relief valve which is pointed downward and attached to the regulator. (Refer to item 31 of Fig.1,2,and 3). Never plug or bypass this safety valve.

SECTION 9 PARTS LIST A. PARTS REQUIRED FOR ALL TESTS (Item numbers refer to Figs. 1,2 or 3) (N/S Refer to Items not shown) ITEM NO. PART NO. QTY DESCRIPTION 1 14015 1 Plug, 1/8 Pipe 2 31515 1 Screw, 1/4-20 x 1/2, Flowmeter, Mount Bracket 3 33606 1 Cartridge Adapter Barrel 4 33620 1 Cartridge Adapter Head 5 33700 1 Pressure Regulator 6 35300 1 Regulating Valve N/S 50700 1 Bara-Defoam, Octanol Defoamer 2 oz. Dropper Bottle N/S 51334 1 5N Sulfuric Acid, 16 oz. Poly Bottle N/S 55201 1 Instruction Manual 7 55204 1 Dispersion Tube (Fritted Disk) 8 55205 1 Injection Port 9 55209 1 Adapter, 3/8-24 X 1/8 NPT 10 55214 1 Flowmeter Bracket 11 55215 1 Injection Gasket (11 spare) N/S 55223 1 Carrying Case 12 55231 1 Gas Train Body 13 55232 1 Gas Train Top 14 55202 4 Thumb Screw 1/4-20 15 55227 2 Connector, Draeger Tube & Fritted Disc. 16 55228 1 Cap, Sample Inlet Luer Fitting 17 55229 1 Sample Inlet Luer Fitting 18 A5059 2 Flowmeter Mounting Screw 20 L1770 1 Reducing Bushing 21 L3703 1 Pressure Gauge 22 L3903 1 Barbed Tubing Elbow Connector, 1/8 MNPT 23 L3906 1 Barbed Tubing Connector, 1/4 FNPT 24 L3907 1 Barbed Tubing Connector, 1/8 MNPT 25 L3979 2 Tubing, Tygon, 1/4 in (6.3 mm) ID X 1/6 in (1.6 mm) Wall N/S l4026 1 Lubricant Grease, "Lubriseal" 26 L4506 1 "O" Ring (1 spare) 27 L4674 2 "O" Ring (1 spare)

PARTS REQUIRED FOR ALL TESTS, Continued ITEM NO. PART NO. QTY DESCRIPTION 28 L6475 4 "O" Ring (2 spares) 29 L8750 1 Flowmeter N/S N3000 1 25 ml Graduated Cylinder 30 N3334 4 10 ml Plastic Syringe w/22 gauge needle 31 L3643 1 Safety Valve 44 55224 1 Bracket, Inlet Port 45 30779 1 Screw, 6-32 X 1/4 BHMS, Inlet Port Bracket B. PARTS REQUIRED FOR WATER BASED SAMPLE, H 2 S DETECTION (Item numbers refer to Fig. 1) (N/S Refer to Items not shown) ITEM NO. PART NO. QTY DESCRIPTION 32 33601 1 Box CO 2 Cartridges (10 per Box) 33 55206 1 Draeger Tubes H 2 S - Low Range 100 to 2000 (10 per Box) 34 55208 1 Draeger Tubes H 2 S - High Range 0.2% to 7.0% (10 per Box) C. PARTS REQUIRED FOR OIL BASED SAMPLE, H 2 S DETECTION (Item numbers refer to Fig. 2) (N/S Refer to Items not shown) ITEM NO. PART NO. QTY DESCRIPTION 32 33601 1 Box CO 2 Cartridges (10 per Box) N/S 51354 1 Citric Acid/Demulsifier/Isopropyl Alcohol, 16 oz. 33 55206 1 Draeger Tubes H 2 S - Low Range 100 to 2000 (10 per Box) 34 55208 1 Draeger Tubes H 2 S - High Range 0.2% to 7.0% (10 per Box) 35 55225 1 Syringe Plunger Lock 36 N5251* 1 Magnetic Stirrer 37 N5258 1 Stirring Rod 1/4 in (.63 cm) Diameter X 1 in (2.54 cm) Long * Required for test but not supplied in standard kit.

D. PARTS REQUIRED FOR WATER BASED SAMPLE, CO 2 DETECTION (Item numbers refer to Fig. 3) (N/S Refer to Items not shown) ITEM NO. PART NO. QTY DESCRIPTION 38 33602 1 Box N 2 O Cartridges (10 per Box) 39 55203 1 Draeger Tubes, CO 2 Analysis (Scaled in PPM) 40 55211 3 Draeger Gas Bag, 1 liter (2 spares) 41 55212 1 Draeger Hand Vacuum Pump 42 55213 1 Straight Bore Stopcock 43 55216 1 Connector Tube, Plastic, 5/16 in (8mm) Diameter X 3 in (7.6 cm) Long E. ACCESSORIES NOT SUPPLIED WITH GARRETT GAS TRAIN KIT PART NO. DESCRIPTION 31700 Hose, 3 ft. 33513 1/8 NPT X Eastman Adapter 34005 Cylinder, N 2 Size D 34265 Regulator Assembly for N 2 Cylinder 64036 Hydrogen Sulfide Paper Disk (pkg. of 100) N5251 Magnetic Stirrer