Determination of Capsaicin Content and Pungency Level of Five Different Peppers Grown in Nigeria.

Similar documents
Determination of capsaicinoid profile of some peppers sold in Nigerian markets

DETERMINATION OF CAPSAICIN CONTENT AND PUNGENCY LEVEL OF DIFFERENT FRESH AND DRIED CHILLI PEPPERS

DETERMINATION OF THE CONTENT OF CAPSAICIN AND DIHYDROCAPSAICIN IN TWELVE VARIETIES OF CHILLI PEPPERS USING LIQUID CHROMATOGRAPHY WITH UV/VIS DETECTION

Experiment GC : Analysis of BTEX by GC-FID

Differences of capsaicinoids content in pericarp and paste of soft-flesh Capsicum spp. fruit

Variation of capsaicinoids in chilli (Capsicum frutescens L.) cultivars with the maturity of fruits in middle hill conditions of western Himalayas

Influence of process parameters on the extraction of capsaicinoids from various Capsicum species cultivated in Romania

May 1, By John Heim,Doug Staples

Retention Time Locking: Concepts and Applications. Application

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Impact of Organic Solvents in the Extraction Efficiency of Therapeutic Analogue Capsaicin from Capsicum chinense Bhut Jolokia Fruits

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

GCMSD-Headspace Analysis SOP

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

Chilli Oleoresin Paprika Oleoresin Paprika Extract Oil

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Rapid and Reliable Detection of Dissolved Gases in Water

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Longterm Detection of Anabolic Steroid Metabolites in Urine

Gas Chromatography-Mass Spectrometry Analysis Of Organics In Drinking Water: Concentrates And Advanced Waste Treatment Concentrates, Vol.

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

Extended Application Note

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Gas chromatographic determination of 1,4-dioxane at the

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Pressurized Liquid Extraction of Capsaicinoids from Peppers

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

M/s. Thermo fisher Scientific

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Arizona Department of Public Safety. And Phoenix Police Department. Oleoresin Capsicum Staff Study

SIMPLE, EFFICIENT AND SIMULTANEOUS DETERMINATION OF ANABOLIC STEROIDS IN HUMAN URINE

FAST EVAPORATION AT NORMAL PRESSURE

LCMSMS Solutions For Steroid Analysis

FROG-4000 TM Chemical Analysis System

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

Carrier Gases in Capillary GC

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Agilent Dimension Software for ELSD User Manual

CHEMTRACE Fremont Blvd. Fremont, CA 94538, Tel: (510) Fax: (510)

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

HPLC Determination of Capsaicinoids with Cross-Linked C18 Column and Buffer-Free Eluent

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

M A T E R I A L S A F E T Y D A T A S H E E T

no peaks missing peaks too small peaks increasing retention decreasing retention

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

Best Practice for Identifying Leaks in GC and GC/MS Systems

Addressing the World Shortage of Helium

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

IJPAR Vol.6 Issue 1 Jan - Mar Journal Home page:

Operation of the Perkin Elmer TGA-GC/MS

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Supplementary Information

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

3. Coupled Techniques in Thermal Analysis

SUPPORTING INFORMATION

Chemical Analysis for Methyltestosterone

This GC has two columns (I think new columns can be ordered from Restek)

Video Notes. LC Troubleshooting Series Retention Time Shifts

Svensk läkemedelsstandard

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

Automated Determination of Dissolved Gases in Water Anne Jurek

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

APPLICATION NOTE. GC Integrated Permeation Device

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

IMPACT OF THE HELIUM SHORTAGE ON PROCESS GAS CHROMATOGRAPHS

Wave Energy Atlas in Vietnam

TRACE LEVEL DETERMINATION OF PER- AND POLYFLUOROALKYL SUBSTANCES (PFASs) IN WATER USING THE AGILENT 6460 LC/MS/MS

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Multiple Gas#5 GC configuration Jan 2016

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

Transcription:

Determination of Capsaicin Content and Pungency Level of Five Different Peppers Grown in Nigeria. 1 C.O. Nwokem *, 2 E.B. Agbaji, 2 J.A. Kagbu, 2 E.J. Ekanem 1 National Research Institute for Chemical Technology, Zaria, Nigeria. 2 Department of Chemistry, Ahmadu Bello University, Zaria, Nigeria. onyenwokem@yahoo.com Abstract: The determination of capsaicin content in five different peppers grown in Nigeria without the need for a derivatization step is here presented. Extraction of capsaicin was done using methanol as solvent and capillary Gas Chromatography-Mass Spectrometry used for quantitation. Nsukka Yellow pepper (Capsicum chinense) had the highest concentration of capsaicin (9.177 ± 0.268mg/g) and pungency level (146,823.20 SHU), whereas, Zaria tatashe (Capsicum annuum) had the lowest concentration (1.189 ± 0.073mg/g) and pungency level (19,015.20 SHU). All the peppers analyzed in this study can be classified as very highly pungent as the Scoville Heat Unit (SHU) values exceed 80,000, except the tatase, Zaria (Capsicum annuum) which has a mean SHU value of 19,015.20. [New York Science Journal 2010;3(9):17-21]. (ISSN: 1554-0200). Keywords: Pepper, Capsaicin, Gas Chromatography-Mass Spectrometry Introduction Peppers belong to the family Solanaceae, genus Capsicum and species annuum, frutescens or chinense. They are widely used in many parts of the world as a result of their valued sensory attributes; colour, purgency and aroma. Pungency, a commercially important attribute of peppers, is due to the presence of six chemically related compounds; capsaicin, dihydrocapsaicin, norcapsaicin, nordihydrocapsaicin, homocapsaicin and homodihydrocapsaicin which constitute the capsaicinoids group (Perucka and Materska, 2001). The two most abundant capsaicinoids in peppers are capsaicin and dihydrocapsaicin, both constituting 90%, with capsaicin accounting for ~71% of the total capsaicinoids in most of the pungent varieties (Kosuge and Furuta, 1970). Capsaicin content of peppers is one of the major parameters that determine its commercial quality. Capsaicin is the active principle which accounts for the pharmaceutical properties of peppers. It has been used as an analgesic against arthritis pain and inflammation (Deal et al., 1991). It has been reported to show anticancer effect (Moore and Moore, 2003) and neurogenic inflammation (burning and stinging of hands, mouth and eyes) (Szolcsanyi, 2004). The latter property is the basis for the use of capsaicin as defensive pepper sprays. Capsaicin has also been reported to show protective effects against cholesterol and obesity (Kempaiah et al., 2005). Pepper pungency is measured in Scoville Heat Units (SHU) and Scoville organoleptic test was used initially for measuring SHU (Scoville, 1912). There are five levels of pungency classified using Scoville Heat Units (SHU): - non-pungent (0-700 SHU), - mildly pungent (700-3,000 SHU), - moderately pungent (3,000-25,000 SHU), - highly pungent (25,000-70,000 SHU) and; - very highly pungent ( 80,000 SHU) (Weiss, 2002) However, the Scoville organoleptic test has been replaced with chromatographic methods which are considered more reliable and accurate. High Performance Liquid Chromatography has been the method of choice as most workers have reported the need for derivatization when using Gas Chromatography. The aim of this work was to devise a simple method for the determination of the capsaicin content in five commonly consumed peppers in Nigeria using Gas Chromatography-Mass Spectrometry without the need for a derivatization step. *Corresponding author 17

Materials and Methods Peppers used for this study were purchased from local retail markets in the region where they are grown. The peppers used in the study are Atarugu, Zaria (Capsicum annuum var), Tatase Zaria (Capsicum annuum), Yellow pepper, Nsukka (Capsicum chinense), Atarugu, Miango (Capsicum annuum var) and Atarugu, Makurdi (Capsicum annuum var). Extraction of capsaicin from the pepper samples was done using the method described by Collins et al., (1995) with slight modifications. GCMS Analysis Conditions Injections were performed by AOC-20i Auto injector (Shimadzu, Japan). A Rtx-5MS column (5% diphenyl, 95% dimethylpolysiloxane stationary phase), 30m 0.25mm i.d. (Restek, USA) was used. The column temperature program is as follows 60 C for 5min, 15 C/min to 140 C for 0min, 25 C/min to 280 C for 10min (25.93 min total). The carrier gas used was helium with a flow rate of 1.61ml/min. While the detector was a quadrupole mass spectrometer (MS) with EI ionization at 70eV in full scan mode. Standard Curve The following standard solutions were prepared from a stock solution of capsaicin using serial dilution: 20, 40, 60, 80 and 100mg/dm 3. The standard solutions were run on the Gas Chromatograph Mass Spectrometer (GCMS) and the standard curve plot of peak area against concentration obtained. Capsaicin Quantitation The major capsaicinoid, capsaicin, in the peppers was determined by reference to an external capsaicin standard (Sigma, USA). Identification and quantitation of capsaicin in the peppers analyzed were made by comparing the peak retention time and area with those of the external standard analyzed under identical GC- MS conditions. Scoville Heat Unit Conversions Capsaicin contents were converted to Scoville Heat Units by multiplying the pepper dry weight capsaicin content in grammes of capsaicin per gramme of pepper by the coefficient of the heat value for capsaicin; which from literature is, 1.6 10 7 (Todd et al., 1977). Results and Discussion Methanol was chosen as extraction solvent because it is non-toxic and has been reported to give high extraction efficiency with reduced amounts of pigments and oils extracted with capsaicin as compared to other suitable solvents like acetone (Attuquayefio and Buckle, 1987; Collins et al., 1995). Extraction and quantitation was carried-out in duplicate for each variety. The standards used for the standard curve were injected at intervals during sample injection to confirm retention time. The chromatograms in figures 1 and 2 reveal that capsaicin with a molecular ion [M] = 305, eluted at between 18.9 and 19.0min. In all chromatograms obtained for the peppers analyzed, the peak of interest was identified upon search with the GCMS as capsaicin. Effective separation of the various components of the pepper extracts and identification of capsaicin was possible by capillary GCMS. The pepper contents obtained in mg/dm 3 were converted to Scoville Heat Units (Table 2) in order to classify them into the various pungency levels. Results obtained showed varied capsaicin content in the peppers used for this study. The Capsicum annuum pepper had the lowest capsaicin content and was the least pungent as compared to the Capsicum annuum var. and Capsicum chinense peppers. Similar variation in Capsaicin content of different peppers has been previously reported (Sanathombi and Sharma, 2008). Table 1. Capsaicin content of the whole peppers a Pepper variety Zaria atarugu Makurdi Miango Zaria tatase Nsukka Yellow Mean values 0.546 ± 0.014 0.642 ± 0.015 0.670 ± 0.023 0.116 ± 0.007 0.810 ± 0.024 a values in mg/g ± SD on fresh weight basis, n = 2 18

Figure 1. Chromatogram and mass spectrum for 100 mg/dm 3 standard capsaicin. Figure 2. Chromatogram, mass spectrum and quantitative results for atarugu Makurdi pepper. 19

Table 2. Capsaicin content of the dry whole peppers b Pepper variety Zaria atarugu Makurdi Miango Zaria tatase Nsukka Yellow Mean values 5.960 ± 0.153 6.264 ± 0.142 7.172 ± 0.242 1.189 ± 0.073 SHU % Capsaicin 95,364.00 100,228.80 114,744.00 19,015.20 146,823.20 9.177 ± 0.268 b values in mg/g ± SD of dry weight, n = 2 0.596 0.626 0.717 0.119 0.918 The use of SHU is the traditional method for pepper evaluation as it provides a better indicator of the pungency level, but is considered less precise (Collin et al.,1995). All the pepper varieties except for Zaria tatase were classified as very highly pungent, with their pungency above 80,000 SHU (Table 2). Nsukka yellow has the highest pungency level (146,823.20 SHU). All peppers used in this study, with the exception of Zaria tatase fall within the pungency limit (0.5-0.9%) presented by the BPC, hence are recommended for Oleoresin production, which is used in the formulation of certain pharmaceuticals. On the basis of capsaicin content, all the pepper varieties except Zaria tatase can serve as potential sources of capsaicin for use in the pharmaceutical industry. The concentration capsaicin would expectedly have been higher if only the placenta of the pepper varieties were used for analysis as capsaicin is produced in the placental glands. Conclusion Yellow pepper (Capsicum chinense), obtained from Nsukka, the South Eastern part of Nigeria is the most pungent of the peppers studied. All the peppers analyzed in this study can be classified as very highly pungent as the Scoville Heat Unit (SHU) values exceed 80,000, except the tatase, Zaria (Capsicum annuum) which has a mean SHU value of 19,015.20. This implies that all the pepper varieties studied, with the exception of the tatase, Zaria (Capsicum annuum) can serve as potential sources of capsaicin. Acknowledgements: Authors are grateful to the National Research Institute for Chemical Technology, Zaria, Nigeria for access to the Shimadzu QP-2010 GCMS in the course of this work. References 1. Attuquayefio V., Buckle K. Rapid Sample Preparation Method for HPLC Analysis of Capsaicinoids in Capsicum Fruits and Oleoresins. Journal of Agricultural and Food Chemistry1987; 35: 777-779. 2. British Pharmaceutical Codex. The Pharmaceutical Press, London, 1973. 3. Collins M.D., Mayer-Wasmund L., Bosland P.W. Improved Method for Quantifying Capsaicinoids in Capsicum using High- Performance Liquid Chromatography. HortScience 1995; 30: 137-139. 4. Deal C.L., Schnitzer T.J., Lipstein E., Seibold J. R., Stevens R.M., Levy M.D., Albert D., Renold F. Treatment of Arthritis with Topical Capsaicin: A Double-blind Trial. Clinical Therapy1991; 13(3), 383-395. 5. Kempaiah R. K., Manjunatha H., Srinivasan K. Protective Effect of Dietary Capsaicin on Induced Oxidation of Low-Density Lipoprotein in Rats. Journal of Molecular and Cellular Biochemistry 2005; 275: 7-13. 6. Kosuge S., Furuta M. Studies on the Pungent Principle of Capsicum. Part XIV: Chemical Constitution of the Pungent Principle. Journal of Agricultural and Biological Chemistry 1970; 34: 248-256. 20

7. Moore D. J., Moore.D. M. Synergistic Capsicum-Tea Mixtures with Anticancer Activity. Journal of Pharmacy and Pharmacology 2003; 55(7): 987-994. 8. Perucka I., Materska M. Phenylalanine Ammonia-lyase and Antioxidant Activities of Lipophilic Fraction of Fresh Pepper Fruits Capsicum annuum L. Journal of Innovative Food Science and Emerging Technologies 2001; 2:189 192. 9. Sanatombi, K., and Sharma, G. J. Capsaicin Content and Pungency of Different Capsicum spp. Cultivars. Notulae Botanicae Horti Agrobotanici Cluj-Napoca 2008; 36(2), 89-90. 10. Scoville W.L. Note on capsicum. Journal of the American Pharmaceutical Association 1912; 1:453. 11. Szolcsanyi.J. Forty years in Capsaicin Research for Sensory Pharmacology and Physiology. Neuropeptides 2004; 38: 377-384. 12. Todd, P., Bensinger, M., and Biftu, T. Determination of Pungency due to Capsicum by Gas-Liquid Chromatography. Journal of Food Science 1977; 42: 660-665. 13. Weiss E.A. (2002). Spice Crops. CABI Publishing International, New York, 2002; 411. 6/29/2010 21