CONTRAfluran. Contrafluran TM -Anaesthetic Gas Filter with Standard Mount. Instruction for Use

Similar documents
Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

Instructions for use Compressed air injector with water trap

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Anesthesia Workstation

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Anesthesia. Midmark Animal Health Products

Keeping anaesthetic pollution to minimum in theatre environment

Standard Specification for Anesthetic Gas Scavenging Systems Transfer and Receiving Systems 1

A9600 Anesthesia Workstation. Your healthcare, we care.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

OPERATING INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Yoke Block Instruction Manual

M5400 Operators Manual

MEDICAL GAS OUTLETS & PROBES

The anaesthesia workstation focused on you

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

ISO INTERNATIONAL STANDARD. Breathing system filters for anaesthetic and respiratory use Part 2: Non-filtration aspects

Genie Supreme TM Model 123HP Installation & Operation Instructions

Operating Instructions Hand Test Pump BHP 700

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

BleaseDatum Anesthesia Vaporizers PEACE OF MIND. Serving The HealthCare Industry

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

ekom Compressor for Medical Air Sonata with Ekom

DPA 02 TM Diamedica Portable Anaesthesia System INSTRUCTIONS AND USER GUIDE

Making Life Easier Easypump II

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

PRODUCT NUMBER: Rd40 Aluminium Canister K2

Anes Machine Use and Pre-use Check - CA1 focus

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

MEDAP-MOBILE GAS SUPPLY

MSA AUER SSR 90 [K60]

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

User Manual. Quantos Automated Dosing Liquid Module

Siphon vessel / Priming aid

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Pulmonex II Training Presentation

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Declaration of Conformity as per Directive 97/23/EC

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Safety instructions and operating manual

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Operating manual for Material pressure tanks Vol./1 and Vol./2

AUTOVENT 4000 VENTILATOR

APC Pressure Reducer with Sensor

Genie Supreme Model 123 Installation & Operation Instructions

OPERATION MANUAL PNEUMATIC VALVES

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Breathing Circuits. Product training

ISO 5367 INTERNATIONAL STANDARD. Breathing tubes intended for use with anaesthetic apparatus and ventilators

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

SILENTAIRE TECHNOLOGY

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Micro Dial-Flowmeter. Instructions for Use

OPERATING INSTRUCTIONS

CAST IRON SAFETY VALVE TYPE 6301

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

NITRONOX SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Instruction for Use of Balloon Inflator JS-CE-SM-12-01, A/0

Instrument Operating Manual

Fire Escape Hood OPERATION AND INSTRUCTIONS

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

The anaesthesia workstation focused on you

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Operating Instructions

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

LISTADO DE CIRCUITOS DE PACIENTE

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Instructions for SILEX 1C Mixed bed cartridge filter

Oxygen Dialflow Meter. Instructions for Use

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Operating Instructions SKYJET Compact Sub-distributor

Installation and commissioning instructions 255 series and 256 series

NARKOVET ANAESTHETIC UNIT

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Anesthesia Machine Intro

Solstice Liquid Blowing Agent (LBA) and Solstice Gas Blowing Agent (GBA)

Pressure Regulators. Instructions for Use

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

ISO INTERNATIONAL STANDARD. Sleep apnoea breathing therapy Part 2: Masks and application accessories

Dräger X-plore 3500 Half Mask

Transcription:

CONTRAfluran Contrafluran TM -Anaesthetic Gas Filter with Standard Mount Instruction for Use

This instruction for use contains information about the CONTRAfluran TM -System, consisting of the CONTRAfluran TM -Anaesthetic gas filter, the standard mount and the logistic. Please read the instruction for use carefully before performing installation and operation of the CONTRAfluran TM -System. The instruction for use is one of the product s components and needs to be kept in direct proximity of the devices, so that it will be accessible for the operating personnel at any time. Table of contents 1. What is CONTRAfluran TM? 2. Appropriate use 3. Transportation, storage and operation of the CONTRAfluran TM -Anaesthetic gas filter 3.1. Transportation 3.2. Storage 3.3. Operation 4. Application areas of the CONTRAfluran TM -System 4.1. Application in operation areas with exhaust device 4.2. Application in intensive care units and ambulatory treatment areas 4.3. Application with the AnaConDa-System 5. What is to be considered during the application of the filter? 6. Redemption and disposal of the CONTRAfluran TM -Anaesthetic gas filter 7. Technical data 8. Customer service

1. What ist CONTRAfluran TM? CONTRAfluran TM is a world new innovation. It is a technology protected by international patents and other patent applications with which noxious anaesthetic gases are completely adsorbed out of the expiration air of a patient. The CONTRAfluran TM -Anaesthetic gas filter is a special filter consisting of solid materials, distinguished by their rugged grain structure, extensive surface and high microporosity. This highly porous internal structure adsorbs efficiently and retains volatile anaesthetic gas components selectively from the exhaled gas as it passes through the filter. The standard mount helps to fasten the CONTRAfluran TM -Anaesthetic gas filter. 2. Appropriate use The CONTRAfluran TM -Anaesthetic gas filter is intended to remove volatile anaesthetic gases in operation rooms, intensive care units, as well as mobile, and ambulatory treatment areas independent of the kind of the exhaust device used. The CONTRAfluran TM -Anaesthetic gas filter is designed exclusively for these applications. Every use exceeding the specified purpose is prohibited. Moreover it must also be noted, that the filter must only be used by trained skilled personnel. The standard mount should only be used in combination with a CONTRAfluran TM -Anaesthetic gas filter during sedation and operation of patients using volatile anaesthetics like Sevofluran, Isofluran or Desfluran. Only strict compliance with the specifications included in this instruction for use can guarantee the safe and efficient use of the CONTRAfluran TM - System. The ZeoSys GmbH or his authorized representatives will not accept any liability or damage, which is caused by incorrect or unreasonable use of the filter. 3. Transportation, storage and operation of the CONTRAfluran TM -Anaesthetic gas filter and the standard mount This chapter describes the transportation, storage, operation and service of the CONTRAfluran TM - Anaesthetic gas filter. To make the performance of your filter effective and to help ensure your safety, be sure to follow all proper application procedures. 3.1. Transportation During the transportation of the CONTRAfluran TM - System, the following points should be considered: The dispatch carton should be transported with the label showing on the top. The carton should not be put on its top or on its side. Open the carton from the top. Keep the original carton for back transport. 3.2. Storage If the filter is supposed to be stored while it is not being used, please consider the following facts: The dispatch carton should be stored with the label showing on the top. Do not store in the open air, but exclusively in suitable rooms which are dry and dustfree. We recommend a maximum relative humidity of 80%. Storage temperature should be 5 C to +40 C.

3.3. Operation Before using the filter, ensure that all components needed for a proper use are available. These including: The CONTRAfluran TM -Anaesthetic gas filter The standard mount Accessories: flexible hose ISO 22 and operationally adapters to use with different exhaust ports For initial operation, please follow the procedures below: A. Attach the CONTRAfluran TM -Anaesthetic gas filter to the expired gas outlet valve of the respirator by means of a flexible hose. The following pictures show the steps, which are necessary to attach the filter to the expired gas outlet valve. A2. Insert the filter into the mount. A3. Remove the seal cap from the filter. A1. Fasten the mount to the rail of the respirator/ anaesthetic gas device. A4. Connect the flexible hose to the filter. A5. Note down the applied anaesthetic gas on the top label of the filter.

4. Application areas of the CONTRAfluran TM - System 4.1. Application in operation areas with exhaust device Anaesthetic apparatus Flexible hose ISO 22 5. What is to be considered during the application of the filter? Apply only one kind of anaesthetic gas per filter. Mark the respective applied anaesthetic gas on the corresponding label of the filter. Filter change must be done: when approximately 267 ml anaesthetic gas is applied. The used filter should be clearly marked in order to avoid any repeated use. 6. Redemption and disposal of the CONTRAfluran TM -Anaesthetic gas filter 4.2. Application in intensive care units and ambulatory treatment areas Respirator with gas monitor Flexible hose ISO 22 Close the used filter with the seal cap. Put the used filter back into the original dispatch carton. Six used filters packed in each original dispatch carton should be returned (charge free) to the manufacturer or its legal distributor (Deposit returnable). The manufacturer takes over a professional disposal of the filters. For back transport use only the original dispatch cartons. 4.3. Application with the AnaConDa-System Gas monitor Gas monitor line Ventilator Flexible hose ISO 22 AnaConDa Agent supply line Syringe pump

7. Technical data CONTRAfluran TM - Anaesthetic gas filter Product-class according to MDD Class 1 Temperature Operation: +5 to +40 C Storage: 5 to +40 C Relative Humidity Operation: up to 80% Storage: up to 80% Storage capacity Flow-Resistance Height Diameter Weight Volumen Approx. 400 g 1,5 mmws 19 cm 12 cm Approx. 1.000 g 2 l Product description CONTRAfluran TM -Anaesthetic gas filter Standard mount (without fill level control unit) Mount with SENSOfluran TM -Fill level control unit Flexible hose 22 mm (interface 17 cm) Flexible hose 22 mm (interface 40 cm) Flexible hose 6 mm (Length 180 cm) Connector 22 mm (a/i), with 6 mm port Connector 22 mm a / 30 mm i Art. no. Zeo000050 Zeo000051 Zeo000052 Zeo000060 Zeo000061 Zeo000062 Zeo000066 Zeo000067

8. Customer service In the case of a malfunction of any product, please contact our customer service. You can reach our customer service as follows: Volmerstraße 13 D-12489 Berlin-Adlershof Telephone: +49-30/92 70 10 31 +49-172/3 81 10 94 Fax: +49-30/9 26 81 32 Email: info@zeosys.de Internet: www.zeosys.de www.contrafluran.de