WITT-Gasetechnik GmbH & Co KG

Similar documents
GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

OXYBABY - MOBILE HAND HELD GAS ANALYSER

WITT-GASETECHNIK GMBH & CO KG

»Gases right? Package tight?«

How much do customer returns cost you?

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Pneumatic high-pressure controller Model CPC7000

Synthetic air supply by WITT hygienic, safe, cost-effective!

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Pneumatic high-pressure controller Model CPC7000

LT GasAnalyzer beyond standards

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Columbus Instruments

Hand-held pressure calibrator with integrated pump Model CPH6600

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Precision digital pressure gauge Model CPG1000

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Mass Flow Controller (MFC) for Gases

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Dräger X-act 5000 Automatic Dräger Tube Pump

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Additel 761 Automated Pressure Calibrators Selection Guide

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Additel 761 Automated Pressure Calibrators Selection Guide

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Additel 761 Automated Pressure Calibrators

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Mass Flow Meter (MFM) for Gases

780S Ultra High Purity Series

Mass Flow Controller (MFC) for Gases

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Using the UltraRAE. Firmware 2.35

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Additel 761 Automated Pressure Calibrators

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Technical Data Sheet MF010-O-LC

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

ADT 761 Automated Pressure Calibrator

Expert Hydrostatic Level Transmitters

C-Flow Coriolis Mass Flow Meters

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Additel 761 Automated Pressure Calibrators

SonoMeter 30 Energy Meters

Real-time gas analysis and software for the management of bioprocessing

Precision pressure sensor Basic version Model CPT6020

Mass Flowmeters. Mass Flowmeters for Gases

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Automatic Isokinetic Sampler. ST5 Evo

The New PHD 4 Portable Helium Detector

IRwin Methane Leak Detector. Innovation makes the difference

We measure it. For gas and water installers. testo hpa. bar

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

FAS-W. Features. Applications. Automatic condensation hygrometer

EPP4 Pressure Regulator Basic G 1/4"

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

SITRANS P measuring instruments for pressure

Supplementary Operator s Manual 42/24-14 EN Rev. 3

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Additel 780 Series Pressure Controller

Industrial pressure controller Model CPC4000

628 Differential Pressure Decay Leak Tester

Dräger RZ 7000 Test Equipment

FTC130 Transmitter. Operating Manual

CI-SfB 732 (5-1) x. - laboratory fittings

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

FLAMMABLE GAS SENSOR/TRANSMITTER

Oxidation Stability of Gasoline and Aviation Fuels

better measurement Simply a question of

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

High-performance submersible pressure transmitter For level measurement Model LH-20

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Ultra High Purity Model 780S

159 mm 154 mm. Subject to changes 10/2012

Filter Integrity Testers for the Pharmaceutical Industry

Dräger RZ 7000 Test Equipment

Series Environmental Chambers

Additel 780 Series Pressure Controller

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

GasSense NDIR User Manual

Pressure Calibrators. Series PC..., PM...

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Mass Flow Controller (MFC) for Gases

Transcription:

Gas analysers Portable multi-functional Analyser MAPY 4.0 for, C, He or /C vertical display inclined display Product Information / Analysing System for the monitoring of protective atmospheres in food packaging (MAP) and welding. For continuous analysis (in-line) and also intermittent sampling via a needle e.g. from food packs. A flexible analyser to guarantee quality and productivity of production processes. Available as a single or double analyser for carbon dioxide, oxygen, helium. minimum sample gas required for analysis of smallest volumes (e.g. food packaging) fast response time fast measuring results of sampling simple to operate via touch-screen reliable steady measuring results and high accuracy through pressure compensation simple calibration of sensor permanent monitoring of set limit values alarm signals are given if the set limits are exceeded and a potential free contact operates to e.g. auto-stop your machine to avoid quality problems easy to clean stainless steel housing for maximum hygiene, splash-proof USB connection for file transfer by USB memory stick Ethernet connection for network integration internal audible alarm measured data storage administration of product names user management for measurement personalisation Options vertical or inclined display fully automatic calibration software WITT-GasControl for recording of results (see separate data sheet) separate table printer for instant documentation plug set for external connection of signals model for higher inlet pressures bar code scanner for product names or user selection diverse Ethernet cable only vertical displays: selectable cable length for potential free contacts selectable cable length for power supply heating and thermostat for chemical measuring cell Equipment selection Applications Analysis Gases Food Welding Sampling Continuous Analysis C /C helium Type of equipment MAPY 4.0 S 3) MAPY 4.0 L 3) 2) 3) MAPY 4.0 S+L 1) 3) MAPY 4.0 P 1) without pump, with inlet pressure regulation 2) with 2 chemical sensors for oxygen 3) gases to be specified All versions also available with zirconia measuring cell for. Please add Zr to the model type. B01/H0 subject to change MFA 4

Gas analysers Measuring systems Gases Measuring system Measuring range Repeatability Response time Service life for sampling chemical measuring cell ± 0.2% 6 sec. approx. 2 years in air for continuous analysis chemical measuring cell ± 0.2% 10 sec. approx. 3 years in air optional for sampling and for continuous analysis for sampling and for continuous analysis C zirconia measuring cell * ± 0.1% 2 sec. no limited paramagnetic measuring cell infrared measuring cell adaptable 0-30% dependent on measuring range 5 sec. no limited ± 0.5% 6 sec. no limited helium thermal conductivity 0-30% ± 0.2% ± 0.5% 20 sec. no limited * no recommend for measures between 20 22% Type MAPY 4.0 Gases Temperature range (gas/environment), C, He or /C not for flammable, corrosive or toxic gases! 0 C to +40 C (+32 F to +104 F) Gas connections Permanent measuring lance, hose connection for PK 6/4 (exhaust) integrated measuring gas pump Sample measuring needle (exhaust) integrated measuring gas pump Calibration (full automatic) hose connection for PK 6/4 Inlet pressure S-version P-version Calibration Gas consumption Calibration time Alarm signals Interfaces Housing Weight Dimensions (HxWxD) max. 0.3 barg 1.5 barg 10 barg approx. 1 l/min the real gas consumption for calibration is depending on installation. optimal: 240 sec/calibration 2 potential free contacts for min. and max. settings (adjustable for each gas) RS 232 with ASCII-output of date, time, measured value USB by memory stick for profiles, product and user data RJ45 Ethernet FTP-Server for profiles, product and user data, software Update analog output 4-20 ma or 0-10 V stainless steel, splash-proof approx. 13.5 kg approx. 110 x 300 x 260 mm (approx. 4.33 x 11.81 x 10.24 inch) Voltage Power consumption 230 V AC 50 / 60 Hz 110 V AC 50 / 60 Hz 230 V AC / 0.12 A Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC B01/H0 subject to change MFA 4

WITT-GASETECHNIK GMBH & CO KG GAS ANALYSERS Portable multi-functional Analyser MFA for, C, He or /C Analysing System for the monitoring of protective atmospheres in food packaging and welding. For continuous analysis (in-line) and also intermittent sampling via a needle e.g. from food packs. A flexible analyser to garantee quality and productivity of production processes. Available as a single or double analyser for carbon dioxide, oxygen, helium. Product Information minimum sample gas required for analysing of smallest volumes (e.g. food packaging) fast measuring results of sampling simple to operate reliable steady measuring results and high accuracy through pressure compensation simple calibration of sensor permanent monitoring of set limit values alarm signals are given if the set limits are exceeded and a potential free contact operates to e.g. auto-stop your machine to avoid quality problems easy to clean stainless steel housing for maximum hygiene, splash-proof Options fully automatic calibration (for single gas analysers) software WITT-LOGGER for recording of results separate table printer for instant documentation lockable door with window to prevent tampering audio-visual alarms plug set for external connection of signals model for higher inlet pressures Equipment selection Applications Analysis Gases Food Welding Sampling Continuous Analysis C /C helium Type of equipment MFA III 2) MFA III S MFA L 1) 3) MFA P 1) without pump, with inlet pressure regulation 2) with 2 sensors for oxygen 3) gases to be specified Measuring systems Gases Measuring system Measuring range Repeatability Response time Service life O2 for sampling chemical measuring cell ± 0.2% 6 sec. approx. 2 y. in air O2 for continuous analysis chemical measuring cell ± 0.2% 10 sec. approx. 4 y. in air optional O2 for sampling and for continuous analysis O2 for sampling and for continuous analysis CO2 helium zirconium measuring cell paramagnetic measuring cell infrared measuring cell thermal conductivity 0-25% adaptable 0-30% 0-30% ± 0.1% dependent on measuring range ± 0.5% ± 0.2% ± 0.5% 2 sec. 5 sec. 6 sec. 20 sec. unlimited unlimited unlimited unlimited F5 subject to change. MFA

WITT-GASETECHNIK GMBH & CO KG GAS ANALYSERS Type Gases Temperature range (gas/environment) Gas connections Permanent measuring Sample measuring Inlet pressure Alarm signals Interfaces Housing Weigth Dimensions (HxWxD) (without carrying handle) Voltage Power consumption MFA, C, He or /C not for flammable, corrosive or toxic gases! 0-45 C (32-113 F) hose connections for ID 4 mm needle max. 0.3 barg 2 potential free contacts for min. and max. settings (adjustable for each gas) RS 232 with ASCII-output of date, time, measured value analog output 4-20 ma or 0-10 V stainless steel, splash-proof approx. 13.5 kg approx. 222 x 325 x 455 mm (8.74 x 12.80 x 17.91 inch) 230 V AC 50 / 60 Hz 110 V AC 50 / 60 Hz 230 V AC / 0.12 A Approvals Company certified according to ISO 9001:2000 and ISO 14001 CE-marked according to: - EMC 89/336/EWG - Low Voltage Directive 73/23/EWG F5 subject to change. MFA

GAs analysers Oxybaby M+ for or /C standard version Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate sample tests at the packaging machine, in stores or in laboratories. OXYBABY M+ a cost effective mobile alternative to tabletop / fixed analysers. Ensure that the quality of packaged product is maintained (HACCP), guaranteeing continued customer satisfaction. The ideal instrument for sample tests with a minimum sample gas requirement, allowing the smallest of modified atmosphere packages (MAP) to be tested. Integrated data log of the last 100 measurements assigned to specific product names or line numbers. minimum sample gas requirement for smallest packs cordless operation using rechargeable batteries simple one hand operation easy to clean large illuminated graphic display multilingual menu guide: German, English, French, Italian, Dutch, Swedish, Finnish, Spanish, Polish, Japanese and Russian integrated needle cover to protect the user Complete in carrying case Product Information charging device and mains adaptor CD-ROM with: - operating instructions 2 spare needles 2 spare filters set of 100 rubber seals case dimensions (HxWxD): approx. 325x385x115 mm (12.79x15.16x4.53 inch) case weight: approx. 1.7 kg Other models, options and accessories available on request. Please identify the individual gases at the time of enquiring! A01/A0 subject to change OXY 1

GAs analysers OXYBYBY M+ OXYBYBY M+ /C Gases balance gas: N 2, Ar (others on request) and/or C balance gas: N 2, Ar (others on request) Measuring principle electro-chemical cell Measuring principle C IR-absorption Sensor lifetime approx. 2 years (in air) Sensor lifetime C unlimited Measuring range ; in 0.1%-steps Sample gas requirement < 10 ml Sample time max. 10 sec. Calibration simple two point calibration Sampling automatic via needle using integrated pump Data log last 100 measurements assignment of measurements to different product names or line numbers Multilingual German, English, French, Italian, Dutch, Swedish, Finnish, Spanish, Polish, Japanese and Russian Temperature (gas/environment) 5 40 C (41 104 F) Display backlit Shut down automatic after 2 minutes of non-use Housing shock resistant plastic Weight approx. 600 g (without accessories) Dimensions (HxWxD) 187 x 106 x 91 mm (7.4 x 4.2 x 3.6 inch) (without needle) Power supply 2 integrated rechargeable batteries (mains adaptor + charging device included) Charging device 110 240 V AC Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC A01/A0 subject to change OXY 1

GAs analysers Oxybaby 6.0 for or /C Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate sample tests at the packaging machine, in stores or in laboratories. OXYBABY a cost effective mobile alternative to tabletop / fixed analysers for welding and food technology. Ensure that the quality of packaged product is maintained (HACCP), guaranteed continued customer satisfaction. The ideal instrument for sample tests with a minimum sample gas requirement, allowing the smallest of modified atmosphere packages (MAP) to be tested. Applicable wherever printed measurement results are required. Together with the exclusive WITT-LOGGER-Software the measured results can be documented providing complete traceability (HACCP). Provide your customer with the results ensuring that your product has the best possible pack quality. minimum sample gas requirement for smallest packs integrated data log of the last 500 measurements product administration up to 25 users, 100 product names and 50 packaging lines cordless operation using rechargeable batteries NEW data transfer and charge of batteries via USB port optional integrated bar code scanner for product data sample flow control with warning in case of blocked needle upgraded simple one hand operation easy to clean large illuminated graphic display multilingual menu guide integrated needle cover to protect the needle and user Complete in carrying case Options charging device data cable Product Information CD-ROM with: - WITT-LOGGER-Software (demo-version) - operating instructions 2 spare needles 2 spare filters set of 100 rubber seals case dimensions (HxWxD): approx. 325x385x115 mm (12.79x15.16x4.53 inch) case weight: approx. 1.7 kg WITT-LOGGER-Software licence code for instant documentation Bluetooth (e.g. for separate printer) over pressure version with pressure regulator equipment for measurement in bottles and cans Other models, options and accessories available on request. Please identify the individual gases at the time of enquiring! A01/A0 subject to change OXY 2

GAs analysers OXYBYBY 6.0 OXYBYBY 6.0 /C Gases balance gas: N 2, (Ar or others on request) and/or C balance gas: N 2, (Ar or others on request) Measuring principle electro-chemical cell Measuring principle C IR-absorption Sensor lifetime > 2 years at concentrations < 20.9% Sensor lifetime C unlimited Measuring range ; in 0.1%-steps Sample gas requirement < 4 ml /C < 6 ml Sample time max. 6 sec. max. 10 sec. Calibration simple two point calibration Sampling automatic via needle using integrated pump Data log last 500 measurements interface for transfer of logged data assignment of measurements to different product names Communication USB port Software WITT-LOGGER Multilingual German, English, French, Italian, Dutch, Swedish, Finnish, Spanish, Polish, Japanese, Russian, Turkish and Hungarian (more to follow) Temperature (gas/environment) 5 40 C (41 104 F) Display backlit Shut down automatic after 2 minutes of non-use Housing shock resistant plastic Weight approx. 580 g (without accessories) Dimensions (HxWxD) 187 x 106 x 91 mm (7.4 x 4.2 x 3.6 inch) (without needle) Power supply 3 integrated rechargeable batteries (charging device included) Charging device 110-240 V AC Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC A01/A0 subject to change OXY 2

WITT-GASETECHNIK GMBH & CO KG GAS ANALYSERS PA-, PA-C or PA- /C inclined display vertical display Compact analyser for the monitoring of protective atmospheres in food packaging (MAP) and welding. For continuous analysis (in-line) and also intermittent sampling via a needle e.g. from food packs. A flexible analyser to guarantee quality and productivity of production processes. Whenever you need a record of your measurement this instrument together with the exclusive WITT-LOGGER-Software is the solution. Provide your customer with the results proving that your product has the best possible quality. system errors or exceeding of set limits trigger an alarm and switch a potential free contact (e.g. to shut down machinery to avoid quality problems) splash-proof and robust housing interface for transfer of logged data Product Information minimum sample gas required for analysing of smallest volumes (e.g. food packing) fast measuring results of sampling integrated data logger for the last 100 measurements assignment of measurements to different product names multilingual menu guide: German, English, French, Italian, Dutch, Swedish, Finish, Spanish, Polish, Japanese and Russian (more to come) Options vertical or inclined display software WITT-LOGGER for recording of results incl. data cable (see separate data sheet) separate table printer for instant documentation Other models, options and accessories available on request. Please identify the individual gases at the time of enquiring! Measuring systems Gases Measuring system Measuring range Repeatability Response time Service life for sampling for continuous analysis C chemical measuring cell chemical measuring cell zirconia measuring cell infrared measuring cell ± 0,2% ± 0,2% 6 sec. 10 sec. approx. 2 y. in air approx. 4 y. in air 0-25% 4 sec. unlimited 0-30% ± 0,5% 6 sec. unlimited A7 subject to change PA 2

WITT-GASETECHNIK GMBH & CO KG GAS ANALYSERS Type PA- ; PA-C ; PA- /C Gases Measuring system Measuring range /C Calibration /C Withdrawal sample continuous Temperature (gas/environment) Gas connections sample continuous Inlet pressure pump pressure regulator Alarm contacts Interfaces Housing Weight Dimensions (HxWxD) Voltage Power consumption and/or C ; balance gas: N 2, Ar (others on request) not for flammable, corrosive or toxic gases! see table ; in 0.1%-steps simple two point calibration automatic via needle using integrated pump by pump or pressure regulator (optional) 5-40 C (41-104 F) needle with integrated pump hose connection for ID 4 mm with integrated pump max. 0.3 barg max. 10 barg 2 potential free contacts for min. and max. settings (adjustable for each gas) RS 232 with ASCII-output of date, time, measured value analog output 4-20 ma or 0-10 V splash proof approx. 3 kg ca. 145 x 105 x 200 mm (5.7 x 4.1 x 7.9 inch) (without connections) 230 V AC, 110 V AC or 24 V DC 230 V AC, 0.07 A Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 CE-marked according to: - EMC 89/336/EWG - Low Voltage Directive 73/23/EWG A7 subject to change PA 2

Gas analysers Analyser An analyser, available for integration with gas mixers or as a stand alone unit, for continuous analysis (in-line) of the gas concentration for a variety of industrial applications. An analyser to guarantee quality and productivity of production processes. NEW Together with the exclusive WITT- GasControl-Software the measured results can be documented providing complete traceability. Provide your customer with the results ensuring that your product has the best possible quality. MAPY plug-in module Flow control gas mixture Sensor Gas mixer Gas conditioning with pressure regulator and filter Gas inlet with changeover unit zero gas N 2 /Ar H 2 calibration gas analysis gas Control unit EEx-free-Zone EEx-Zone Analyser Scheme for fuel gases Product Information intuitive operation by coloured touch screen control unit different user levels high process reliability continuous monitoring of limit values Ethernet-interface for documentation (QM) on control unit low expenses for calibration (admin mode) multilingual menu guide: German, English, Spanish, Italian, Polish, French, (more to follow) Options exceeding set limits switching a potential free contact (common alarm) Ethernet interface design on back side of gas mixer USB interface design on back/front of gas mixer (depending on dimensions of housing) remote transmission of settings and measured values WITT Web Visio - remote and control of control unit full automatic calibration integrated measured data logging integrated digital printer Other models, options and accessories available on request. Please identify the individual gases at the time of enquiring! A03/E0 subject to change MFA 1

Gas analysers Measuring system ATEX Gases Measuring system Measuring range Repeatability relating to full scale Response time Service life chemical measuring cell ± 0.2% 10 sec. approx. 3 years in air zirconia measuring cell * ± 0.1% 2 sec. no limited C paramagnetic measuring cell infrared measuring cell X CH 4 infrared measuring cell He thermal conductivity 0-30% 0-10% 0-30% ± 0.02% 5 sec. no limited ± 0.5% 6 sec. no limited ± 0.1% 10 sec. no limited ± 0.2% ± 0.5% 20 sec. no limited 0-10 % X H 2 thermal conductivity 0-30 % 0-100 % ± 0.5% 30 sec. no limited other gases on request * no recommend for measures between 20% 22% Type integrated Analyser with gasmixer or stand alone Analyser Calibration sinple two point calibration Withdrawal continuous pressure regulator (factory set) Temperature enviroment - 5 C +40 C (23 F 104 F) gas -15 C +40 C ( 5 F 104 F) Hazardous location ATEX (option) zone 1 II 2G IIC T3 Gas connections (integrated) continuous measurement connected directly to receiver of gas mixer outlet at mixer analysis gas Swagelok 6 mm for pipe OD 6 mm precision regulator Swagelok 6 mm for pipe OD 6 mm Gas connections (stand alone unit) continuous measurement WITTFIX-Rohrverschraubung für Cu-Rohr 6 mm outlet analysis gas WITTFIX-Pipe Couplers for pipe OD 6 mm precision regulator Swagelok 6 mm for pipe OD 6 mm Inlet pressure regulator max. 10 barg Alarm contacts 2 potential free contacts for min. and max. settings (adjustable for each gas) Interfaces RS 232 (internal for printer) USB via stick for measure and fault data RJ45 Ethernet FTP-Server for measure and fault data, WebVisio, Software Update, analog output 4-20 ma or 0-10 V Housing integrated see data sheet according to gas mixer stand alone unit stainless stell, splash proof Weight integrated approx. 1.2 kg in addition to gas mixer stand alone unit approx. 20.0 kg Abmessungen (HxWxD) integrated see data sheet according to gas mixer stand alone unit approx. 280 x 465 x 230 mm (11.0 x 18.3 x 9.0 inch) (sensor housing without connections) approx. 222 x 325 x 455 mm (8.7 x 12.8 x 17.9 inch) (separate control cabinet without connections) Voltage 230 V AC, 110 V AC Power consumption 230 V AC, 0.12 A (depends on sensor technology) Approvals Company certified according to ISO 9001:2000 and ISO 14001 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC - ATEX 95 Directive 94/9/EC A03/E0 subject to change MFA 1

GAS ANALYSERS Ambient Air Monitoring System RLA 100 for the detection of carbon dioxide (C ). Product Information 2 alarm limits (adjustable) digital displays as soon as 4 LEDs for continuous visual monitoring of the gas concentration easily accessible potential free relay contact by cable at lower side on front Control and Display Unit with integrated alarm device (alarm lamp and -buzzer) easy wall mounting Components of system 1. Control and Display Unit 2. Remote Display Unit 3. Cable for connection of Remote Display Unit and Control Display Unit 2 1 Options other gases on request Type 1 Measured gas Sample gas supply Alarm contacts Alarm limits Menu items Display Function keys Safety Housing Dimensions (HxWxD) Voltage Control and Display Unit carbon dioxide (C ): 0 up to 50,000 ppm (5%) (Vol.), NDIR-measuring cell diffusion - 1 volt-free relay contact for activation of external devices at (alarm 1) - Rated: 30 V DC / 250 V AC, max 2 A alarm 1 0.5 / 1 / 1.5 / 2% alarm 2 1.5 / 2 / 2.5 / 3 / 3.5 / 4% check of connection between control and display unit and remote display unit, calibration, change over from C to F, alarms 1, 2 and factory setting - digital, 4 digits, for display of gas concentration with range 0 up to 9999 ppm - digital, 3 digits, for display of gas concentration with range 1 up to 5% - additional digital, 3 digits, for measurement of temperature in C or F - LEDs indicating operation, alarm status and monitoring of voltage reset, menu selection, enter continuous self check of temperature range, life time of sensor, implausible measured values, EEPROM system, internal data transfer plastics, IP 54, splash proof 168 x 125 x 47 mm (6.61 x 4.92 x 1.85 inch) (without connections) 230 V AC Type 2 Menu items Display Function keys Housing Dimensions (HxWxD) Voltage Approvals Tested Remote Display Unit check of connection between control and display unit and remote display unit, change over from C to F - digital, 4 digits, for display of gas concentration with range 0 up to 9999 ppm - digital, 3 digits, for display of gas concentration with range 1 up to 5% - additional digital, 3 digits, for measurement of temperature in C or F - LEDs indicating operation, alarm status and monitoring of voltage check, reset, menu selection, enter, change over of C to F aluminium, IP 54, splash proof 118 x 85 x 34 mm (4.65 x 3.35 x 1.37 inch) (without connections) via data cable to control and display unit Company certified according to ISO 9001:2000 and ISO 14001 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC according to EN 61326-1:2006 Report No.: 15030010 001 A01/F0 subject to change RL 2

GAS ANALYSERS Ambient Air Monitoring System for the detection of oxygen ( ) depletion or carbon dioxide (C ). Product Information 3 alarm limits adjustable within the measuring range digital displays for continuous visual monitoring of the gas concentration connections for alarm easy accessible on forefront easy wall mounting Components 1. Control and Display Unit 2. Transmitter 3. Transmitter cable for connecting of Transmitter and Control Unit 1 Options control and display unit with built-in alarm (audible alarm and emergency signal lamp) flow-through adapter for sensor check and calibration other gases on request 2 Type 1 Control and Display Unit Type 2 Transmitter Gases Input signal Output signal Alarm contacts Function keys oxygen ( ) or carbon dioxide (C ) 0.2 to 1 ma and 4 to 20 ma 4 to 20 ma - 4 volt-free relay contacts for activation of external devices at alarm limits 1, 2, 3 and system fault - Rated: 230 V / 4 A (Please indicate with order whether the relay contacts shall be normally open (NO) or normally closed (NC) acknowledgement of alarm, built-in test and check of measurement range and calibration; relay function test Measured gas Sample gas supply diffusion Special features Housing Dimensions (HxWxD) Voltage oxygen ( ) 0% - 25% (Vol.), electro-chemical sensor carbon dioxide (C ) 0% - 5% (Vol.), Infrared-sensor - service access to test switch - test connectors for measurement of measuring signal - potentiometers for zero and span adjustment aluminium, IP 54, splash proof 125 x 80 x 60 mm (4.92 x 3.15 x 2.36 inch) (without connections) 230 V AC or 24 V DC Display - digital, 3 digits, for display of gas concentration and parameters - LEDs indicating of operating status, system fault and alarms 1, 2 and 3 Safety Housing Dimensions (HxWxD) Voltage continuous self check of processor function, excessive / low voltage, cable fault, transmitter function plastics, IP 54, splash proof 185 x 130 x 95 mm (7.28 x 5.12 x 3.74 inch) (without connections) 230 V AC or 24 V DC Approvals Company certified according to ISO 9001:2000 and ISO 14001 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC A01/F0 subject to change RL 1

Gascontrol - center NEW Windows-Software for the documentation of analysis-results of MAPY, LEAK-MASTER, MAPMAX and other WITT- equipment with integated or separate analysis. Product Information / quality control by means of data transfer and storing - date and time - user (name or examiner) - lot data - product line data export data interface for further interpretation of measured data in MS EXCEL data tranfer to Control Unit (touch screen control) - product data - administration of product names - administration of user names inclusive access code logging and readable from up to 21 analysers multilingual interface: German, English, Spanish, Italian, Polish, French, Dutch (more to follow) System requirements Operating system WINDOWS 2000, XP, Vista, 7 Hardware Compatibility graphic resolution min. 800 x 600 pixel standard Ethernet cable installed by customer all MAPY, LEAK-MASTER, MAPMAX and gas mixers with integrated analysers please specify device number with order A01/D0 subject to change GC 1

Gascontrol - Web visio NEW Remote and Control - Function via Ethernet for controlling of software GasControl. login via password same fuction like GasControl programm in the gas mixer same readout and menu navigation on display Product Information / for using no relearning required quality control by means of data recording and storing - date and time - user (name or examiner) - process data tracing export data interface for further interpretation of measured data in MS EXCEL import data from programm to the unit - product data - administration of user names inclusive access code starting of remote and control function by standard internet browser multilingual (depending on gas mixer control) Retrofit on request. A01/D0 subject to change GC 2

moisture analysers Hydrobaby / mfa H 2 O The new handheld HYDROBABY is the smallest, lightest and most price competitive in portable instruments for low dewpoint measurement capability on the market today. NEW The newly designed analysers offer many advantages over older technologies with a larger signal response small change of low water vapor concentrations resulting in greater measurement range -110 C to +20 C dewpoint. The greater speed of measurement, improved reproducibility, sensitivity to ambient temperatures, higher reliability and accuracy with greater cost effectiveness make the instruments a technological leader. The Laboratory and Process Control applications for the moisture analysers meet the needs of a wide range of industries: petrochemical, power generation, medical, pharmaceutical, biotechnology, non-fossil fuels, and industrial gases and environmental. HYDROBABY The measurements are temperature and pressure compensated with built-in sensors (optional). All analysers are provided with traceable calibrations. Product Information fast response time state-of-the-art sensor technology -110 C to +20 C dewpoint easy navigation, large display cordless operation using rechargeable batteries data transfer and charge of batteries via USB port integrated data log of the dewpoint, temperature and pressure large illuminated graphic display model for higher inlet pressures with built-in metering valve and flow meter (MFA H 2 O) HYDROBABY: for mobile measurement MFA H 2 O: portable benchtop analyser Complete inclusive USB-cable AC universal power adapter with USB connector hanging hook and magnet (HYDROBABY) exhaust pigtail (HYDROBABY) CD-ROM with: - software (demo-version) - operating instructions Options passive analog output 4-20 ma (max. 30 V DC power supply by customer) data cable MFA H 2 O Software licence code for instant documentation pressure sensor with automatic dewpoint correction vacuum pump, built-in includes battery and external charger (MFA H 2 O) Other models, options and accessories available on request. C01/D0 subject to change MFA 5

moisture analysers HYDROBABY MFA H 2 O Gases all technical gases (excluding toxic or corrosive gases) No mixtures of fuel gases with! Measuring principle nanopore Sensor lifetime unlimited Pressure Sensor (optional) 0 10.34 bar (absolute) Measuring range -110 C +20 C / -166 F +68 F (dewpoint) Sample gas requirement >1 l/min Response time 95% of step change in 3 min. Repeatability 0.8 C / 1.5 F (dewpoint) Accuracy ±2 C (3.6 F), temperature corrected (dewpoint) Units of measure C and F dewpoint, ppmv, ppmw, µb H 2 O vapor pressure, grams of H 2 O/m 3 and Lbs H 2 O/10 6 standard cubic feet in Natural Gas Calibration simple one point calibration Data log circulating storage for last 4000 measurements interface for transfer of logged data assignment of measurements to different product names Communication USB-Port Software WITT-Software Multilingual German, English, French (more to follow) Temperature (gas/environment) -20 C +60 C / -4 F +140 F Connection 1/8 Swagelok Display backlit Shut down automatic (individual adjustable) Housing shock resistant plastic extruded aluminium IP65, IP68 with Sealing Cap Weight Dimensions (HxWxD) approx. 0.8 kg (without accessories) approx. 1.6 kg (without accessories) 187 x 106 x 50 mm (7.36 x 4.17 x 1.97 inch) 199 x 162 x 84 mm (7.83 x 6.38 x 3.31 inch) Power supply 1 integrated rechargeable battery (charging device included) Charging device 110-240 V AC, 50-60 Hz Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC C01/D0 subject to change MFA 5

NEW: OXYBABY 6.0 The next generation of mobile gas analysis Extended data storage for more than 500 measurements Large, high resolution display shows all information at a glance Integrated barcode reader* Data transfer and charging via USB-Port New control element for easier navigation Bluetooth* Alarm function in the event of needle or filter blockage Flow Control: Adjustment of pump action in the event of needle or filter blockage

The WITT OXYBABY - your ideal partner for mobile sample analysis of food packages : Minimum sample gas required (< 4 ml) suitable for small packages Integrated data storage, saves the last 500 measurements Administration of up to 25 users Classification of measurement results for up to 100 products and 50 packaging lines Flow control and alarm function in the event of a needle or filter blockage Multilingual menu Optional rig for headspace analysis of cans and bottles Connection of a separate printer possible via Bluetooth Also available as pressurised gas sample version Included in delivery: Carrying case approx. 238 x 380 x 100 mm (H x W x D) 2 spare needles 2 spare filters Set of 100 rubber seals Mains adaptor Detailed documentation *Optional: Data cable GAS CONTROL CENTRE software Barcode Reader Bluetooth WITT-Gasetechnik GmbH & Co KG Salinger Feld 4 8 D-58454 Witten POB 2550 D-58415 Witten Germany Tel.: +49 (02302) 8901-0 Fax: +49 (02302) 8901-3 witt@wittgas.com

Gas analysers CAN-PIERCER for OXYBABY Accessory for the easy measurement of oxygen and carbon dioxide in bottles and cans of various sizes in combination with the analyser OXYBABY. minimal gas sample volume required reliable test results safe and simple operation adjustable for different sizes of bottles and cans robust design, strong probe integrated needle-protection for packages with metal- or plastic-lids or caps Note: Please find further technical information about the measurement and the data administration on the OXYBABY data sheet. Product Information Preparation of the OXYBABY for application as a Can-Piercer: 1. Unscrew the probe protection of the OXYBABY counterclockwise and take it off. 2. Remove the probe of the OXYBABY and unscrew the filter counterclockwise. Then screw the filter on the probe holder of the Can-Piercer. ATTENTION! The analyser is only to be operated with the special filter! * analyser and bottle not included in package 3. Insert the OXYBABY into the holding brackets of the Can-Piercer. 4. Connect one end of the tube (connector with external thread) to the OXYBABY, and the other end to the filter on the probe holder. 5. For further details please refer to the operating instructions of the OXYBABY. Type Can-Piercer for OXYBABY Material steel Weigth 7.5 kg (without OXYBABY ) Dimensions (HxWxD) Height of bottles or cans 585 x 155 x 235 mm (23.03 x 6.10 x 9.25 inch) packed, without OXYBABY ) max. 400 mm (15.75 inch) Approvals Company certified according to ISO 9001:2000, ISO 14001 and IS2000 F9 subject to change CP 1

WITT-GASETECHNIK GMBH & CO KG OXYBABY / MFA / ZUBEHÖR ACCESSORIES ACCESSOIRES ACCESSORI ACCESORIOS CZESCI ZAMIENNE РАСХОДНЫЕ МАТЕРИАЛЫ D Nadeln Dichtungsplättchen Filter Sensor UK F IT SP PL RU JP Needles Foam rubber seals Filter Sensor Aiguilles carrées de mousse étanche Filtres Senseur Ago Guarnizione di gomma Filtro di ricambio Sensore di ossigeno Agujas Plaquitas de goma Filtros Sensor Igly Podkladki uszczelniajace Filtry Sensor Иглы Пластыри герметизирующие Фильтры Датчик Bestell.-Nr., Order-No, No de Réf., cadice no., Ref.-N, Nr katalogowy, Номер артикула, 800.499700E Product Information 800.507900 800.462800 800.515100 Mindestbestellwert minimum order minimo fatturabile pedido minimo minimalna wartść zamówienia минимальная сумма заказа 50 min F7 subject to change manufactures mixing-, metering and control equipment as well as analysing systems and safty equipment for all common gases OXY / MFA 2

SOFTWARE WITT-LOGGER Windows-Software for the documentation of analysis-results of OXYBABY 6.0, MFA, PA and other WITT- equipment with control system (AWS). Product Information quality control by means of data recording and storing with date and time individual product administration of lot no., article no., examiner etc. data-export interface for further read-out of the measured data in MS EXCEL simultaneous logging from up to 8 analysers multilingual interface automatic identification of the connected WITT-Analyser administration of product names System requirements Operating system WINDOWS 2000, XP, Vista, 7 Hardware Compatibility Accessories Option 1 free serial interface, graphic resolution min. 800 x 600 Pixel all MFA, PA, OXYBABY 6.0, WITT-analysers with AWS please specify device number with order USB connecting cable included in delivery RS232-adapter cable A01/D0 subject to change LOG