WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Similar documents
ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

STANDARD OPERATING PROCEDURES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

SANP ACTING RELAYS YT-520/525/530 SERIES

LOCK UP VALVES YT-400/405/430/435 SERIES

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Constant Pressure Inlet (CCN) Operator Manual

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

92831 TEL: (714) FAX:

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Installation Instructions JATCO Environmental Protection Tank Model J-7000

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Manual Solvent Purification System. Innovative Technology, Inc.

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.

Glove Box Installation Manual

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

In Vivo Scientific, LLC INSTRUCTION MANUAL

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Precision Hydrogen (All B&W Screen Models)

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Installation and Use Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

MP15 Jockey Pump Controller

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

RK-IR Sample Draw Aspirator Adapter Operator s Manual

UNIVERSAL MASK TEST SYSTEM

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

STANDARD OPERATING PROCEDURES

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

I have to say that I had no idea about compressors. That means it s easy for everybody.

Rejuvenation Instructions

Agilent Auxiliary Gas Module AGM 2. User s Guide

Agilent Inlet EPC Leak Test

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

CC Burst Test System

Installation, Operation & Maintenance Manual

DPC-30 DPC-100. Reference Manual

Installing ASI Umbilical Delivery Systems

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

To use the Atex valve model is obligatory to consult the appropriate manual.

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

CircuFlow Quick Setup Guide

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

MB-SP Series Solvent Purification System

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

92831 TEL: (714) FAX:

TR Electronic Pressure Regulator. User s Manual

BGA244 Binary Gas Analyzer

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Model 6202 Reduced Oxygen Breathing Device 2

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

PANACEA P200 STAINLESS STEEL USER MANUAL

BCGA GUIDANCE NOTE 17

CSA Sample Draw Aspirator Adapter Operator s Manual

Interface Devices, Inc. Hydraulic Mini Mule

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

BD Cytopeia Fluidic Kit User s Guide

HumiSys HF High Flow RH Generator

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Agilent 1290 Infinity Pump Head Maintenance

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Instruction Manual Dräger MSI P7 and MSI P7 plus

Procedure of Xenon Transfer

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

KJ4000 Operating Instructions & Parts Manual NSN

Stainless Steel 142 mm Filter Holder YY

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

FIRESTORM. Assembly Instructions. Electric Upgrade Kit for the Autococker. Designed & Manufactured by PGI

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

J Air and Water Kit Instructions Part# 02584

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Halsey Taylor Owners Manual STOP!

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Arizona State University NanoFab XACTIX ETCHER. Rev A

University of Minnesota Nano Center Standard Operating Procedure

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Digital Vacuum Regulator

University of MN, Minnesota Nano Center Standard Operating Procedure

Transcription:

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, 80524 PHONE #: (970) 221-9179 FAX #: (970) 221-9364 TO-Clean Manual

Copyright 2008 by Wasson ECE Instrumentation, Inc. (SJC 02/05/2008) All rights reserved worldwide Printed in the United States of America This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or transmitted into any human or computer language, in any form or by any means electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Wasson-ECE Instrumentation, Inc., 101 Rome Court, Fort Collins, CO 80524. DISCLAIMER OF WARRANTY AND LIMITED WARRANTY THIS PUBLICATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND. WASSON ECE INSTRUMENTATION, INC. DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATION REGARDING THE USE, OR THE RESULTS OF THE USE, OF THIS PUBLICATION IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY, CURRENTNESS, OR OTHERWISE. FURTHER, WASSON-ECE INSTRUMENTATION, INC. RESERVES THE RIGHT TO REVIEW THIS PUBLICATION AND TO MAKE CHANGES FROM TIME TO TIME IN THE CONTENT HEREIN WITHOUT OBLIGATION OF WASSON-ECE INSTRUMENTATION, INC., TO NOTIFY ANY PERSON OR ORGANIZATION OF SUCH REVISION OR CHANGES.

NOTE TO THE END USER THIS MANUAL SHOULD BE READ IN ITS ENTIRETY, PRIOR TO USE OF THE APPLICATED INSTRUMENT. ONCE READ, PLEASE FOLLOW THE INSTRUCTIONS IN THE GETTING STARTED SECTION OF THE MANUAL IN SETTING GAS PRESSURES AND SUPPLYING APPROPRIATE POWER TO THE GAS CHROMATOGRAPH.

TABLE OF CONTENTS 1.0 SYSTEM OVERVIEW... 5 2.0 INSTALLATION... 5 3.0 OPERATION... 10 3.1 SETTING THE OVEN TEMPERATURE... 10 3.2 CONNECTING THE CANISTERS... 11 3.3 SOFTWARE CONTROL... 11 3.3.1 METHOD CONFIGURATION... 11 3.3.2 CANISTER CLEANING... 14 3.3.3 DIAGNOSTICS... 15 4.0 PLUMBING DIAGRAM... 18 5.0 WARRANTY... 18

1.0 System Overview TO-Clean is a revolutionary canister cleaning system developed by Wasson-ECE Instrumentation. The TO-Clean canister cleaner allows for fully automated canister cleaning. The TO-14/15 compliant TO-Clean system was designed to take the guess work out of canister cleaning. The twelve 6-liter canister capacity will increase your lab s efficiency. The system is fully automated, allowing the user to start a cleaning cycle and walk away. Using the touch screen controller, up to ten custom methods can be defined and loaded as needed. The system also comes with an automated leak check method to ensure system performance. This provides a high performance system that is easy to use as well as consistent. An on-board touch screen embedded controller makes system operation as easy as pressing start. The controller allows the user to save up to ten different methods. The user can define each method including: number of cycles, pressure, and soak times. Once the method has been defined, it is saved and is accessible for later use. 2.0 Installation Unpack and inspect the system for any damage that may have been incurred during shipment. Place the cleaner on a bench top or on the optional system cart. Connect all gas lines, vacuum lines and power as described below and as shown in Figures 2.1-2.6. Unpack the vacuum pump and place it on the floor next to the canister cleaner. Attach the vacuum valve hose assembly to the back of the system. Attach the 1/8 vacuum valve actuation air hose to the vacuum valve. Attach the 1/8 nitrogen charge line to the vacuum valve tee assembly. Connect all gases to the back of the control box as labeled. 5

Figure 2.1: Vacuum Valve Tee Assembly Nitrogen Charge Gas Vacuum Valve Valve Actuation Air Vacuum Hose to Dewar U-Tube Connect vacuum hose from pump to dewar U-tube as shown in Figure 2.2-2.3. Figure 2.2: Vacuum Hose Connection to Pump Vacuum Hose to Dewar U-Tube 6

Connect vacuum hose from the dewar U-tube to the T-assembly as shown in Figure 2.3. Figure 2.3: Vacuum Hose Connection to Dewar U-Tube Vacuum Hose to Pump Vacuum Hose to Valve Assembly 7

Connect 1/8 line from compressed nitrogen to 1/8 dewar U-tube and from the u- tube to the bottom of the humidification chamber. Connect the provided 1/8 tubing from the top of the humidification chamber to the back of the control box as labeled and shown in Figure 2.4 and 2.5. Figure 2.4: Connection to Humidifier To back of control box as labeled To compressed nitrogen or charge gas 8

Figure 2.5: 1/8 Nitrogen Charge Gas Connection to Dewar U-Tube Nitrogen or charge gas through Dewar 9

Connect the dewar bracket to the side of the canister cleaner as shown in Figure 2.6. Slide the dewar into the bracket and place both vacuum and nitrogen u-tubes into the dewar along with the provided insulating cap. Plug the power cable to the back of the control box. The power switch is located on the back of the control box. Set the power switch to the on position. Figure 2.6: Dewar Bracket 3.0 Operation 3.1 Setting the Oven Temperature The oven temperature is controlled by the Watlow controller located on the front of the control panel. Set the controller temperature to the temperature at which you wish to clean the canisters. 10

3.2 Connecting the Canisters Place the place the canisters into the oven and connect them to the ¼ Swagelok fittings provided with the steel flex tubing. If there are any positions that are unused ensure that position is plugged with the provided ¼ Swagelok plug. 3.3 Software Control When the controller is powered on using the power switch located on the back of the controller the user is presented with the Start Menu (Figure 3.3.1) which allows the user to select one of three options: Configure Methods, Diagnostics, or Clean. Figure 3.3.1: Start Menu 3.3.1 Method Configuration From the Start Menu select Configure Methods. In the Configuration screen (Fig 3.3.2) the user is able to configure the method including Cycle Setup, Pressure Setup, and Canister End State. Figure 3.3.2: Configuration Screen 11

To configure a method, start by selecting Cycle Setup. In the Cycle Setup screen (Fig 3.3.3), the user can select the number of cycles desired by touching the up and down arrows. Notice that for each cycle, both the Low and High Pressure Cycle Times can be adjusted. Each cycle can have different low and high pressure cycle times. Once the desired settings have been achieved select Accept to return to the Configuration screen. Figure 3.3.3: Cycle Setup From the Configuration screen (Fig 3.3.2) select Pressure Setup. In the Pressure Setup screen (Fig 3.34) for each cycle set the charge pressure and the vacuum pressure. Figure 3.3.4: Pressure Setup 12

Select Accept to return to the Configuration screen (Fig 3.3.2). Before the method is saved choose a Canister End State. The canister end state allows the user to select if the canisters will be under vacuum or under pressure at the end of the cycle. If the canisters will need to be tested for certification after cleaning, select Pressure. The pressure of the canister will be left at the Charge Pressure of the last cycle. If the canisters will need to be readied for sampling then select Vacuum. The canisters will be left at the Vacuum Pressure of the last cycle. This pressure is set in the Pressure Setup screen (Fig 3.3.4). After the method has been configured the user can save and name the method using the keyboard provided in the Save Method screen (Fig 3.3.5) by choosing Save from the Configuration (Fig 3.3.2) screen. Type the name of the new method and choose Save. After saving the method the user is returned to the Configuration screen. From the Configuration screen choose Accept. This will return the user to the Start Menu (Fig 3.3.1). 13

Figure 3.3.5: Save Method Screen 3.3.2 Canister Cleaning In the Start Menu (Fig 3.3.1) select Clean. The Clean Menu (Fig 3.3.6) displays the Method that is currently loaded. To start cleaning using the loaded method parameters, select Clean. If no method is listed as loaded or a different method is desired, select Load Method. Figure 3.3.6: Clean Menu In the Load Method screen scroll to the desired method using the arrows on the side of the screen and choose Load. 14

Figure 3.3.7: Load Method Screen Once the method has been loaded the user is returned to the Clean Menu and the loaded method is displayed on the screen. The method has now been loaded and is ready to clean. Select Clean. The system will start to run the method and the Cleaning status screen (Fig 3.3.8) will be displayed. Cleaning status will display the status of the system including number of cycles remaining, cycle status, pressure and time remaining for the current cycle. Using the Cancel button the cleaning can be cancelled at any time. Figure 3.3.8: Cleaning Status 3.3.3 Diagnostics The control software allows the user to diagnose the system for potential problems. By selecting Diagnostics from the Start Menu the user can leak check the system and actuate valves in the system to diagnose valve problems. 15

The Diagnostics screen (Fig 3.3.9) allows the user to select Valve Control or Leak Test the system. Figure 3.3.9: Diagnostics All system valves can be tested using the Valve Control menu (Fig 3.3.10). This menu allows the user to actuate the Pressure Valve, Vent Valve, and Vacuum Valve. When the valve is actuated the user will hear the valve switch. If the valve switch is not audible then contact the Wasson-ECE service department for support (970) 221-9179. Figure 3.3.10: Valve Control The Leak Test menu (Figure 3.3.11) allows the user to check that the system is leak tight. If the system is not leak tight achieving lower vacuum will be difficult if not impossible. From the Diagnostics menu select Leak Test. Using the arrows choose a desired charge pressure and a soak time. If the system holds pressure to 16

+/- 0.4 psi the system is considered leak tight and will pass the test. If the system fails the leak test secure all fittings and run the leak test again. The status of the leak test is displayed in the Leak Test menu. The leak test feature can also be used to ensure the canisters have been attached properly and that none of the canister fittings are loose before cleaning. Figure 3.3.11: Leak Test Menu Figure 3.3.12: Leak Test Status 17

4.0 Plumbing Diagram V2 V3 V1 5.0 Warranty Wasson-ECE Instrumentation provides a one-year limited warranty of all installed parts and system performance, excluding data handling devices. The warranty is in effect from the day the instrument is shipped from Wasson-ECE Instrumentation. After receiving the instrument, verify the instrument was not damaged in transit. Contact Wasson-ECE Instrumentation if the instrument was damaged. This warranty does not include problems from modifications made to the system by the end-user after installation. The warranty excludes any misuse of the instrumentation, acts of God, damage from user-supplied gases and line power, and lack of sample conditioning. Please contact us with any questions or problems that arise. Wasson-ECE Instrumentation 101 Rome Ct Fort Collins, CO 80525 970-221-9179 Tel 970-221-9364 Fax 18