Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

Similar documents
Introduction to Pneumatics

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

KEG PUMP. Range of Electric Keg Pumps

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

CNG FILLING STATIONS

HYDRAULICS. H89.8D - Hydraulic Bench

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Product Range. High performance and economic high pressure solutions Made in Germany

AUTOMATIC HOSE TEST UNIT, TYPE SPU

WORKHOLDING APPLICATION BOOKLET

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Pressure Calibrators. Series PC..., PM...

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Tightness control TC. Product brochure GB 3 Edition AGA

CCT-7320/ROC-2313 Reverse Osmosis Controller

Pneumatic high-pressure controller Model CPC7000

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

TEST BENCH FOR SAFETY VALVES

HumiSys HF High Flow RH Generator

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

PRC CO ² -LASER PRESENTATION

Pneumatic spool valve islands

EPP4 Pressure Regulator Basic G 1/4"

Liquid ring vacuum pumps single-stage

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Valve test benches. Systems overview

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Liquid ring vacuum pumps in compact design

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

Pneumatic high-pressure controller Model CPC7000

GROUTEC SCOTT VICKERS. Grouting Equipment

High-performance submersible pressure transmitter For level measurement Model LH-10

Technical Information Conducal CLY421

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

THE UNIVENTOR 400 ANAESTHESIA UNIT

Gripping rotary modules

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Operation Manual Air Saver Unit ASV5000 Series

Safety Beyond the Electrics

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

GAS INJECTION TECHNOLOGY GIT

Model PDT Dewpoint Transmitter

Pressure Automated Calibration Equipment

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Agilent Auxiliary Gas Module AGM 2. User s Guide

BOSS PULISCI PROVA IMPIANTI MEDIA

Transmitter CS 21 Operation Manual

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

DMX 3 - DMX 3 MF INSTALLATION OPERATION MAINTENANCE. Your distributor : TECHNICAL INSTRUCTIONS (e) Revision

MoveRoll Conveyor Operating and Maintenance Manual

The Discussion of this exercise covers the following points:

UsER manual for Watersens ph -REDOX

CAPITAL CONTROLS SERIES NXT3000

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Armfield Distillation Column Operation Guidelines

14. Exploded View. Page 68

Calera Fire Department Breathing Air System Technical Specifications

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

High Pressure Breathing Air Compressors

EcoFuel Natural Gas Drive in Touran and Caddy

TECHNICAL DATA. Q = C v P S

Squeegee Unit for MRS Multi-Recovery System

Air Operated Hydraulic Pumping Systems to 50,000 psi

User Manual MFCS TM -EZ

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

Additel 780 Series Pressure Controller

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Hot Water Stationary Unit

BUBBLER CONTROL SYSTEM

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary.

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Customer Responsibilities

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Series Environmental Chambers

ALL TERRAIN CRANE AR-1200M-1

Additel 780 Series Pressure Controller

InFlow Modular perfusion bioreactor

Gas Absorption Draft Standard Operating Procedure

Tightness controls TC 1 3 and TC 4

TECHNICAL DATA. Q= Cv S

Transmitter CS 21 Operation Manual

Transcription:

1 ITV bench is equipped with a INJETVISION vision system whose purpose is to observe and study the jets from high pressure diesel injector in inert atmosphere (nitrogen or CO2) up to 50 bar (± 0.5 bar). ITV Injector Test for spray Visualisation 1

composition 2 Operating cabin including InjetVision system Safety components (sensor, push button, emergency stop switch) Electric cabinet Pneumatic cabinet Cooling system with heat exchanger (air / water) Temperature control system of the test fluid (oil / water) The high pressure management system comprises a drive motor, a high pressure pump and high capacity pressure accumulator. Two hydraulic drawers (oil supply of injection pump, feeding pressure control, temperature conditioning and precise filtering of the test fluid). Recycling tray Measurement cabinet.

benefits - Gasoline or diesel injector - Complete control of the image chain: acquisition, image processing, automated analysis of results - Complete characterization of injection jets - Real-time processing - Low gas consumption - Modular installation - Injector adapter made to measure - Ability to integrate other measurement equipment: IFR, continuous flow meters torque. complete characterization of injection jets - Penetration of a jet - Percentage of jet penetration - Opening angle of a jet - Surface of the jet - Volume of a jet - Symmetry - Spray slick angle for lambda view - λ angle of a jet in Lambda view - α Angle of a jet - inter-jet angle - Roundness - Measurement of the start of injection - Probability of jet - Film of idling jet. 3 3

Description Chassis Long chassis - Type: 8418 - Dimensions (mm): 2700 x 1200 x 1678 Short chassis - Type: 8555 - Dimensions (mm): 2250 x 1000 x 1580 Cabinet Electrical characteristics - Type: 3P + N + E - Voltage: 400 V - Frequency: 50 Hz - Power: 67 kva 4

Clamping of the injector Over 20 types of adapters have been made: - Straight injector - Motorized rotating injector - Manual rotating injector - Offset injector Others can be made by us on request. Gas management board This board contains all the elements for safe chamber pressurization. 5 The gas is either the nitrogen supply network or a cylinder of 200 bar through a pressure regulator calibrated at 75 bars. 5

Description hydraulic drawer Primary tank: Volume: 60 liters Fluid Type: ISO 4113 Filtration: 3 micron filter Security: 2 level sensors Pump unit: Engine 1.5 kw, 1500 rpm Pump with flow rate of 12 l/m. 6

High pressure rail EFS Volume: 500 ml Maximum pressure: 3000 bar Length: 580 mm Diameter: 140 mm 2 inlets HP pump 8 injector outputs 1 connector for pressure 3000 bar 1 connector for actuator Safety valve Pressure transmitter. Motorization Asynchronous motor: 34 kw @ 1000 rpm Speed: up to 4000 rpm Motor torque: up to 328 Nm @ 1000 rpm. Angular Encoder: 3600/rev. 7 Lubrication station Volume: 20 liters Capacity: 4 l/min Pressure: 1-6 bar (manual) Visual level display Temperature sensor Safety valve 6 bars 25 microns filter 7

security Safety devices Starting the test only after locking doors Control of the drive motors (soft start) Double checks at primary tank: - Temperature of the test fluid (temperature sensor and thermostat) - Fluid level test: two level sensors (critical and security) Check the pressure sensor and mechanical components of the high pressure rail (safety valve and bursting disc) Two emergency stop buttons (punch) Extraction of hydrocarbon vapors. Open Door Mode Safety devices allow to lock the two doors of the test bench during operation. In Open door mode, opening doors is possible at any time to perform maintenance and adjustments while the bench is running. A password is required. 8

Signal column The bench is fitted with a light column. It indicates the operating status of the bench: GREEN operate normally, ORANGE: non-blocking alarm RED: major fault: the bench is stopped. Air extraction The cabin is equipped with an aeration grille. A vent is provided above the bench to connect the customer drain system of the exhaust air. 9 Emergency stop The test bench is equipped with two emergency stop buttons: One on the bench and another on the measurement cabinet. A controller monitors the main functions of the test bench automatically and continuously. In the event of a detected fault on a device, it causes an emergency stop. 9

Softwares Measurement cabinet Measurement cabinet includes: An industrial PC in which SprayAcq and SprayAnalyser software are installed. A rail pressure controller EFS 8549 (HPC) An injector power control module EFS 8527 An ICU unit SAG Module A 24V DC supply. Security elements (light column, circuit breaker, disconnector...) An inverter. 10

SprayAcq This software manages the entire INJETVISION system and controls: - The control pulse of the injector, - The pressure in the chamber of vision, - The pressure in the rail, - The position of the jet deflector, - The rotation of the injector, - The two cameras for shooting bottom and side jets. 11 11

SprayAcq This software is dedicated to the analysis of jets from diesel or petrol injectors. The entire chain of image processing is controlled from image acquisition to image processing and formatting results. 12

Alpha Lambda 13 Single jet 13

injetvision Pressure chamber It is instrumented with a temperature sensor, a pressure sensor and a mechanical gauge. A thermal switch, a safety valve and a rupture disk to ensure the safety of the entire system. The constituent bodies of the pressure chamber are consistent with the pressure equipment directive PED 97/23 EC. Vision chamber Defelector module Fog extractor Lambda camera window 14 Alpha camara window

Fog extractor The vision chamber is equipped with a fog extractor. It aims to eliminate fog after each injection in order to obtain a perfect visualization of the jet. This equipment is necessary for an effective statistical analysis. 15 with without 15

injetvision Camera The camera is used to view the jet of the injector viewed from the side in order to determine the "lambda" angles. Deflector module A single jet can be studied at a time during lateral jet measurement The camera is used to view the jet of the injector viewed from the side in order to determine the "lambda" angles. 16

Lighting Mono-block design allows mounting directly inside the pressure chamber Quality lighting allows injector jet image acquisition in high definition. Gas management board 17 The gas management board is connected to the pressure chamber through a 300 bar high pressure hose equipped with an anti-whiplash cable. This equipment allows the chamber to be pressurized safely. 17

Injector holder Straight injector : 8212-1D-1 8212-1D-11 8212-1D-14 8212-1D-18 Manual rotating injector: 8212-1D-6 8212-1D-9 8212-1D-17 8212-1D-20 Offset injector: 8212-1D-3 8212-1D-4 8212-1D-5 8212-1D-13 8212-1D-15 8212-1D-16 Motorized rotating injector: 8212-1D-2 8212-1D-7 8212-1D-10 8212-1D-12 8212-1D-19 with continuous nitrogen flow 8212-1D-8 18

INSTALLATIONS The InjetVision system can be installed on different chassis: Type : 8555 Dimensions (mm) : 2250 x 1000 x 1580 19 Type : 8418 Dimensions (mm) : 2700 x 1200 x 1678 19

Specifications INJETVISION BENCH ELECTRICAL CHARACTERISTICS Type 3P + N + E Voltage 400 V ±10 % Frequency 50 Hz Maximum current 97 A Power 67 kva FLUID TEST Tank capacity 90 l Heating power 3 KW Cooling power 600 W / K. CIRCUIT OF FEEDING PUMP Maximum flow rate 30 l/mn (@ 6 bar) Filter 10 μm, clogging sensor Inlet pressure (control) 0.8 to 6 bar Outlet pressure (measure) 0 to 10 bar Control temperature 30 C to 60 C (±10 %) LUBRIFICATION Tank capacity 20 l Flow 4 l / min Pressure 1 to 6 bar (manual) Filter 25 μm COOLING CIRCUIT Fluid Maximum flow rate Pressure control Water 12 l/min (4 bar) From 1 to 3.5 bars (factory setting) 20

PRESSURE CHAMBER Maximum temperature 60 C Atmosphere N 2, CO 2 Maximum chamber pressure 50 bar (± 0,5 bar) Maximum working pressure 50 bar (± 0,5 bar) Maximum permissible pressure 53.2 bar Fluid type ISO 4113, ISANE IP 155 Power supply 230 VAC 50 Hertz References ITV 21 21

SITE ADDRESS 192 Allée des Chênes Parc d activité du Baconnet 69700 MONTAGNY FRANCE TELEPHONE & E-MAIL Tel.: +33 (0)4 72 49 27 72 Fax: +33 (0)4 72 49 27 77 e-mail: sales_inj_eng@efs.fr Website: www.injection.efs.fr SUBSIDIARY IN CHINA providing technical support installation, training, maintenance and calibration. North American Rep: brochure banc INJETVISION 22 V3.0-26-03-2014 fr-en Beacon Dynamics Inc. 275 Route 10 E Suite 220-164 Succasunna, NJ 07876 Tel. 973-442-6450 Info@beacondynamics.com