Dispensing Pressure Vessels

Similar documents
Stainless Steel 142 mm Filter Holder YY

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

FloWash. Industrial Filter Cart

Techcon Systems TS1258 Pressure Pot

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

Tank Blanketing Pressure Regulators RHPS Series

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Techcon Systems TS1254 Pressure Pot

Hydraulic Live Swivels

Inline Swivels Switch Your Swivel!

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. y Use only genuine ARO replacement parts to assure compatible. RM051S-XXX-XX Single Post Lift / Ram

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Model ASSEMBLY and OPERATING INSTRUCTIONS

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Instructions Parts List

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

shutoff valves 900 Series psig Manual Shutoff Valves

RK-IR Sample Draw Aspirator Adapter Operator s Manual

P/N: IND-DP Industrial Drum Pumps

RM051S-XXX-XX SINGLE POST LIFT / RAM

OPERATOR S MANUAL

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

ROUGHNECK II Pumpless Drain

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. RM052S-XXX-XX Two Post Lift / Ram

Flexible Metal Hose Products

BS Series Basket Strainer

SINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS. Certified ISO 9001

GILMONT ACCUCAL FLOWMETERS

Stirred Ultrafiltration Cells

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

ZHE+ Zero Headspace Extractor Operation & Instruction Manual

RM052S-XXX-XX TWO POST LIFT / RAM

Corrosion Control Equipment and Supplies

Stirred Ultrafiltration Cells Models 8003, 8010, 8050, 8200, User Guide

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Horizontal Bladder Tanks

Vertical Bladder Tanks

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

PRODUCT DATA SHEET. Description

Constant Pressure Crude Oil Container Model CPCCP

V-24 OXYGEN LANCE VALVE

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

MANIFLEX System. 52B Series 52C Series 52S Series INSTALLATION AND OPERATION INSTRUCTIONS

624 Gas Panels INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

Geotech 1.66 Reclaimer

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Model MTB-ASME Horizontal Bladder Tanks

AIR INLINE METAL SHEAR

Protocol Switchover Station

Inline & 90 Swivels. Hydraulic Live Swivels. Heavy Duty Ball Bearing, Rebuildable Design

600 o F High Temperature Aging Cell Instruction Manual

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Multi-Probe Sampling System User Guide & Manual

Neotecha Tank Sampling Sapro

Geotech 1.66 Auto-Reclaimer Installation and Operation

Proportional Relief Valves

AND OPERATION INSTRUCTIONS

CSA Sample Draw Aspirator Adapter Operator s Manual

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

PRO SINK -R 1 and 2. Dilution system CONTENTS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

LRS(H)4 Pressure-Reducing Regulator User Manual

Model 2000 High-performance Ultrafiltration Cell

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Model MTB-ASME Vertical Bladder Tanks

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Instruction Manual Updated 7/26/2011 Ver. 2.2

Back Pressure Regulator

Model MTB-ASME Vertical Bladder Tanks

Angled Sign Light with Shade

ADAPTABILITY & PRECISION

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

1700ESL Kamvalok Coupler

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Installation Instructions JATCO Environmental Protection Tank Model J-7000

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Right-Angle Tube Roller Model

Installation Operation Maintenance

Propor tional Re lief Valve s

World Area Differences Technical Information

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Switch Your Swivel! Hydraulic Live Swivels. Inline & 90 Swivels. 304 & 440c Stainless Steel Heavy Duty Ball Bearing, Rebuildable Design

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Alkylphosphines. Storage and Handling Recommendations

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn ).

Transcription:

Dispensing Pressure Vessels ASME-UM Code-Complying Catalogue Numbers 5 liter XX67 00P 05 10 liter XX67 00P 10 20 liter XX67 00P 20 1 gallon XX67 00P 01 MILLIPOE COPOATION BEDFOD, MASSACHUSETTS 01730

Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. 2007, Millipore Corporation. All rights reserved. Printed in U.S. Millipore is a registered trademark of Millipore Corporation. Filterjet is a trademark of Millipore Corporation. Freon is a registered trademark of E. I. DuPont de Nemours and Company. Swagelok is a registered trademark of Swagelok Co. Corporation. Viton is a registered trademark of DuPont Dow Elastomers LLC. P30133, ev. E, 01/07 CE mark applies to XX67 00P 10 and XX67 00P 20 only

Introduction Millipore dispensing pressure vessels are designed for dispensing fluids under pressure for filtration through any pressure-type filter holder. The portable vessels are available in 5-, 10- and 20- liter, and in 1-gallon capacities. These ASME-UM code-complying vessels are compatible with ASME code-complying vent/relief valves. NOTE: Millipore recommends installing the vent/relief valve accessory (item f below, Millipore cat. no. XX67 00L 24) prior to use in order to comply with Pressure Directive safety requirements. All wetted surfaces are made of Type 316L stainless steel for maximum corrosion resistance. Inside and outside surfaces are electropolished for ease of cleaning. The vessels can withstand positive pressure up to 7 kg/cm 2 (100 psig). The safety cover assembly is secured by a cam-lock handle. A neoprene rubber cushion provides a skid-free and soft-sounding base. An optional vacuum lid is available (Millipore cat. no. P34188) for vacuum use. Dispensing Pressure Vessel Components Items a e are supplied with the vessel. Items f k are available as accessories. a outlet dip tube f vent/relief valve b pipe plug g pressure gauge c elbow h hex nipple d vessel cover i ball valve e O-ring j quick-disconnect nipple k hose connector

2 www.millipore.com Cleaning 1. Before initial use and after each use, disassemble all threaded fittings and rinse the vessel and fittings with laboratory-grade water. For a more thorough cleansing, wash the vessel with a mild, nonabrasive detergent and a soft brush or sponge before rinsing. 2. Air dry all parts before reassembly. CAUTION: If salt solutions were used in the vessel, rinse thoroughly to prevent corrosion of the vessel and fittings. Using the Dispensing Pressure Vessel The vent/relief valve (f) and the pressure gauge (g) must be used when operating the dispensing pressure vessel. They are included in Millipore s Pressure Vessel Fitting Kit, catalogue number XX67 000 PK, which also inludes optional hex nipples, vent/relief valves, ball valves, quick-disconnect nipples and couplings and hose connectors (items h through k in the Dispensing Pressure Vessel Components diagram). 1. Assemble the dispensing pressure vessel as show in the Dispensing Pressure Vessel Components diagram, using PTFE tape on all threaded male fittings. 2. Attach one end of a hex nipple to a ball valve and the other end to the outlet elbow fitting of the vessel. NOTE: Millipore recommends using ball valves on both outlet and inlet sides. A ball valve on the outlet side controls fluid delivery to the filter holder. A ball valve on the inlet side regulates the supply of gas from the pressure source.

Dispensing Pressure Vessels 3 Using the Dispensing Pressure Vessel, continued 3. Attach a barbed hose connector to each ball valve. NOTE: Millipore recommends using quick-disconnect fittings between the ball valve and the hose connectors to facilitate attachment to and detachment from the vessel. 4. Connect the appropriately sized tubing to each hose connector and secure with hose clamps. 5. Fill the vessel with the liquid to be filtered. 6. Position the O-ring on the lip of the top side of the vessel cover. Insert the cover into the vessel and rotate the cover to align it with the vessel opening. 7. Pull up on the handle to seat the O-ring. Lock the cover in place by forcing the handle down. WANING: When using the pressure vessel with a flammable solvent such as isopropyl alcohol, the following safety precautions must be taken: The pressure vessel must be properly grounded and all grounding connections must be secured before and at all times while dispensing. Proper grounding must be confirmed by verifying electrical continuity between the vessel, dispensing container and the ground. The vessel must be pressurized with an inert gas such as nitrogen.

4 www.millipore.com Chemical Compatibility The wetted surfaces of the vessel and its supplied components are constructed of Type 316 L stainless steel. The cover O-ring supplied with the vessel is constructed of Viton -A elastomer. The recommended vent/relief valve has a Viton-A seal. You can use fluids compatible with these materials in the vessel. O-ing Compatibility Guide Viton-A Viton-A acetone benzene carbon tetrachloride chloroform Freon TF or PCA solvent gasoline hexane isopropyl alcohol N kerosene mineral spirits petroleum ether petroleum base oils silicone oils trichloroethane trichloroethylene xylene : recommended, N: not recommended

Dispensing Pressure Vessels 5 Specifications Materials Type 316L stainless steel with stainless fittings; Viton gaskets and O-rings; EPDM base Pressure 7 barg (100 psig) maximum; not recommended for use under vacuum without accessory closure Depyrogenation If depyrogenation is required, wash the vessel thoroughly with a bactericide and rinse well with sterile, pyrogen-free water. CAUTION: Subjecting the vessel to the normal depyrogenation procedure at 250 C (482 F) for 4 to 5 hours will damage the base of the vessel. Temperature 121 C (250 F) maximum Connections 1/4" NPTF Dimensions Pressure Vessel Unit 5-liter 10-liter 20-liter 1-gallon Cover Opening Shipping Weight 5-liter 10-liter 20-liter 1-gallon 229 mm dia. 241 mm (9 in. 9.5 in.) 229 mm dia. 352 mm (9 in. 13.88 in.) 229 mm dia. 595 mm (9 in. 23.44 in.) 229 mm dia. 213 mm (9 in. 8.44 in.) 83 mm 99 mm (3.25 in. 3.88 in.) 4.6 kg (10.5 lb) 6.2 kg (13.75 lb) 9.3 kg (20.5 lb) 4.2 kg (9.15 lb)

6 www.millipore.com Product Ordering Information This section lists the catalogue numbers for the Dispensing pressure vessels. See the Technical Assistance section for information about contacting Millipore. You can also buy Millipore products on-line at www.millipore.com/purecommerce. Description Component Diagram Key Catalogue Number Dispensing pressure vessels 5-liter XX67 00P 05 10-liter XX67 00P 10 20-liter XX67 00P 20 1-gallon XX67 00P 01 eplacement Parts Outlet dip-tube a 5-liter 6977 10-liter 6978 20-liter 6979 1-gallon P35554 Pipe plug, 1/4" NPT, 316 ss, 2/pk b YY13 010 09 Elbow, 1/4" NPTM/female c XX67 001 04 Vessel cover, cam-lock d 6976 O-ring, Viton-A elastomer, S-381 e XX67 000 59 Accessories Pressure Vessel Fitting Kit (includes items f through k on diagram) XX67 000 PK Vent/relief valve, 7 barg (100 psig) ASME f XX67 00L 24 Pressure gauge, 0 11 barg (0 160 psig) ASME, 316 ss g XX67 00L 15 Hex nipple, 1/4" NPTM, 51 mm (2 in.) length h XX67 001 25 Ball valve, 1/4" NPTF i YY20 293 48 Quick-disconnect nipple and coupling, 1/4" NPT j XX67 000 30 Hose connector, 1/4" NPTM, 316 ss, 2/pk k XX67 00L 11

Dispensing Pressure Vessels 7 Product Ordering Information, continued Description Catalogue Number Filterjet Solvent Dispenser XX67 025 00 Zero Head Space Extractor YT30 090 HW Pressure Vessel Accessories Kit (use with the Zero Head Space Extractor; XX67 00P 00 includes one of each of the following): Adapter, 1/8" NPTF to male luer fitting XX30 025 67 Adapter, 1/4" NPTM to 1/4" tube XX67 025 07 Ball valve, 1/4" NPTF YY20 293 48 Hex nipple, 1/4" NPTM, 51 mm (2 in. length) XX67 001 25 Pressure gauge, 0 7 barg (0-100 psig) YY13 010 15 Quick disconnect female Swagelok 1/4" NPT YT30 090 13 Quick disconnect nipple and coupling 1/4" NPT Tubing, polypropylene 6 mm (1/4 in.) O.D., 3 m (10 ft)xx67 025 08 Vent relief valve, 1/4" NPT, 9 barg (125 psig) XX67 000 24 Closure for vacuum use SD1B 174 V3 PVC tubing, 9.5 mm (3/8 in.) I.D., 3 m (10 ft), with 2 ss clamps XX67 000 34 PVC tubing, 12.5 mm (1/2 in.) I.D., 3 m (10 ft), with 2 ss clamps XX67 000 35 PTFE tape, 12.5 mm (1/2 in.) 6.6 m (260 in.) TP00 013 26

8 www.millipore.com Technical Assistance For more information, contact the Millipore office nearest you. In the U.S., call 1-800-MILLI- POE (1-800-645-5476). Outside the U.S., see your Millipore catalogue for the phone number of the office nearest you or go to our web site at www.millipore.com/offices for up-to-date worldwide contact information. You can also visit the tech service page on our web site at www.millipore.com/techservice. CE Compliance For XX67 00P 01 and XX67 00P 05 the following applies: Millipore Corporation certifies that this product complies with the European Union Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product is classified under Article 3 3 of the Pressure Equipment Directive. In compliance with Article 3 3 of the Pressure Equipment Directive, this product does not bear the CE Mark. For XX6700P10 and XX6700P20 the following applies: This product, fully configured with all accessories, meets the requirements of the European Union Pressure Equipment Directive (PED) 97/23/EC and bears the CE Mark. A Declaration of Conformity stating compliance to the PED Directive and signed by a duly authorized representative of the manufacturer is included with each product.

Dispensing Pressure Vessels 9 Standard Warranty Millipore Corporation ("Millipore") warrants its products will meet their applicable published specifications when used in accordance with their applicable instructions for a period of one year from shipment of the products. MILLIPOE MAKES NO OTHE WAANTY, EX- PESSED O IMPLIED. THEE IS NO WAANTY OF MECHANTABILITY O FITNESS FO A PATICULA PUPOSE. The warranty provided herein and the data, specifications and descriptions of Millipore products appearing in Millipore's published catalogues and product literature may not be altered except by express written agreement signed by an officer of Millipore. epresentations, oral or written, which are inconsistent with this warranty or such publications are not authorized and if given, should not be relied upon. In the event of a breach of the foregoing warranty, Millipore's sole obligation shall be to repair or replace, at its option, the applicable product or part thereof, provided the customer notifies Millipore promptly of any such breach. If after exercising reasonable efforts, Millipore is unable to repair or replace the product or part, then Millipore shall refund to the customer all monies paid for such applicable product or part. MILLIPOE SHALL NOT BE LIABLE FO CONSEQUENTIAL, INCIDENTAL, SPECIAL O ANY OTHE INDIECT DAM- AGES ESULTING FOM ECONOMIC LOSS O POPETY DAMAGE SUS- TAINED BY ANY CUSTOME FOM THE USE OF ITS PODUCTS.