TRENCH AND EXCAVATION COLLAPSE

Similar documents
TRENCH AND EXCAVATION COLLAPSE PROCEDURES

STRUCTURAL COLLAPSE SEARCH AND RESCUE PROCEDURES

SUMMIT COUNTY SPECIAL OPERATIONS RESCUE TEAM TRENCH RESCUE BRANCH TRENCH RESCUE OPERATIONS

Lisle-Woodridge Fire District Trench Rescue STANDARD OPERATING GUIDELINES

ROPE RESCUE OPERATIONS

Rescue Technician: Trench Rescue I/II

GEORGIA FIRFIGHTERS STANDARDS AND TRAINING COUNCIL TECHNICAL TRENCH RESCUE PERFORMANCE EVALUATION SHEET

Committee Input No. 35-NFPA [ Chapter 1 ] Submitter Information Verification. Committee Statement

Developed by Engineers Alex Klinger and Shelby Vrem November 2015

Series Confined Space Rescue - Draft Page 1 of 6 Adopted: Revised: INCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL

Orchard Farm Fire Protection District Standard Operating Procedure

Gaining Access. Lesson Goal. Lesson Objectives 9/10/2012. Explain basics of emergency rescue operations. Additional training recommended

TRENCH RESCUE TECHNICIAN SKILLS LEVEL I

Structural Collapse Search and Rescue

BP OIL -- TOLEDO REFINERY

Cognitive Objectives (1 of 2)

Trench Rescue 1 - NFPA 1006, 2008

Developed by: Purdue University Agricultural Safety and Health Program Department of Agricultural and Biological Engineering West Lafayette, IN

Excavations and Trenches

SPECIAL OPERATIONS COMMAND (SOC) SUPPORT LADDER COMPANIES

Division 09 Special Operations. Chapter 01 Technical Rescue Services February 2009

OGP Supplementary Life-Saving Rules

Confined Space Entry and Rescue

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

Standard Operating Guidelines: Swift Water Rescue Operations

Annual Regional Refresher

Ottawa Fire Services Standard Operating Procedure

NATURAL GAS RESPONSE SOG

Water Rescue

An Overview of Confined Space Rescue Course Objectives

Course Objectives. An Overview of Confined Space Rescue

This section applies to all open excavations made in the earth's surface. Excavations are defined to include trenches.

TRENCH RESCUE TECHNICIAN SKILLS LEVEL II

THURSTON COUNTY FIRE/EMS RESPONSE TO LARGE SCALE VIOLENT INCIDENTS

Trench Rescue 2 - NFPA 1006, 2008

Cedarville Township Volunteer Fire Department Fire Department Standard Operating Guidelines 2008

MASON COUNTY FIRE DISTRICT #4

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

Tonto Rim Search and Rescue (TRSAR) Swift Water Rescue Team Standard Operational Guideline

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

WATER RESCUE RESPONSE SOG

INSARAG EXTERNAL CLASSIFICATION (IEC) CHECKLIST FOR USAR TEAMS

Construction OS&H Working at or below ground level

Excavation and Trenching

CENTRAL ZONE OPERATIONS MANUAL

Safety Manual Section 6 Confined Space

Clear up confusion between the requirements for confined spaces and grain storage structures.

Removal from entrapment or a dangerous situation or position. To be caught within a closed area with no way out 8 Team Members

Rescue Technician: Cave Rescue I/II

Rescue Technician Site Operations

Rescue Technician: Confined Space Rescue I/II

Aluminum Sheeting Guide (ASG)

Participate in a rescue operation

Travis County Emergency Services District #1 Standard Operating Guidelines

Confined Space Rescue Technician Task Book

Rope Rescue. Approved by MCERS on 2/18/2016. These SOGs are based on FEMA guidelines FA-197

SAFE WORK METHOD STATEMENT TRENCHING OPERATIONS

Confined Space Entry

Rescue Core Prerequisites NFPA 1006, Chapter 5, 2008 Skills Completion

STANDARD OPERATING PROCEDURES

Confined Space Entry Procedure Page 1

Technical Rescuer Core NFPA 1006

Total s Golden rules

Summary Report for Individual Task Control Hazards of a Confined Space Status: Approved

TRENCHING/SHORING/EXCAVATIONS Revision Date: 04/2017

STANDARD OPERATING PROCEDURES TACTICAL OPERATIONS b ROPE RESCUE EFFECTIVE: OCTOBER 2007

MINIMUM STANDARDS FOR STRUCTURAL COLLAPSE RESCUE

Rescue Technician: Rope Rescue Level II

Confined Space Entry

HAZ MAT RESPONSE SOG

Confined Space Entry Procedure

SPEED SHORE MANUFACTURER S TABULATED DATA MANGUARDS. October 31, 2005

STEEL TRENCH SHIELDS DW MODELS

Confined Space Entry Safety Program

CONFINED SPACE AWARENESS

SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs

STEEL TRENCH SHIELDS TUFF-LITE MODELS

Rescue Technician Site Operations

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

Summit to Sound Emergency Medical Services Group Standard Operating Guidelines

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

SITE CONTROL, SCENE MANAGEMENT and RISK BENEFIT ANALYSIS

In addition, all personnel assigned to the Field Operations Division will be trained and prepared to support this effort.

Guidelines for Rapid Extraction in a Hazardous Materials Environment

Summary Report for Individual Task Construct Cribbing System(s) to Stabilize a Load Status: Approved

MODULAR ALUMINUM PANEL SHIELDS MAPS

Confined space - A confined space is defined as an area which: A confined space with one or more of the following characteristics:

Course Length: The course is four sessions for a total of 32 hours.

Emergency Response Plans

Progressive Safety Services LLC (c)

MEWP - Boom Note: It is recommended that you read the Supporting Information page before you read this factsheet.

DAILY EXCAVATION CHECKLIST

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

Snohomish County Fire Chiefs Association Document #

The term MAYDAY typically will be used in the following situations:

Work Activity (e.g. Road Work): Work Location:.

Objectives. Demonstrate proper first responder swiftwater PPE and safety. Demonstrate proper floating throw bag throwing technique.

The Johns Hopkins University/The Johns Hopkins Hospital Health, Safety and Environment Manual Safety Policies:

NFPA 1006 Standard on Technical Rescuer Professional Qualifications, 2013 edition Chapter 7.1 Confined Space Rescuer Level I.

MEWP - Scissor Note: It is recommended that you read the Supporting Information page before you read this factsheet.

Transcription:

TRENCH AND EXCAVATION COLLAPSE A. GENERAL This guideline provides operational guidance at rescue incidents that involve the location, disentanglement and removal of victims from sub-surface trench and excavation locations where they are trapped by material or equipment, by collapse, or have a medical emergency in an unprotected trench. This guideline is used in conjunction with NFPA 1670, NFPA 1006 and WAC 296.305. The Incident Commander shall assign the Rescue Group Supervisor. The Rescue Group Supervisor will make position assignments in accordance with the Thurston County Technical Rescue Guidelines and Mobilization Plan as required by the needs of the incident. Definitions: Trench: A narrow excavation in relation to its length made below the surface of the ground. In general, the depth is greater than the width, but the width is not greater than 15 feet. Excavation: A man-made cut, cavity, trench or depression in an earth surface, formed by earth removal and usually is wider than it is deep. Unprotected Trench: Any trench greater than 4 in depth without proper protection. Shoring operations are limited to trenches 20 feet or less in depth without additional specialized resources. Rescue Group Supervisor: Coordinates rescue operations and the functions associated with all activity in the rescue area. The Rescue Group Supervisor will serve as the on-site competent person and will report to the Incident Commander. Technical Rescue Safety Officer: Responsible for monitoring safety at the confined space site and will coordinate actions with the Rescue Group Supervisor. The Technical Rescue Safety Officer has the authority to stop any and all rescue site actions deemed unsafe and immediately report them to the Rescue Group Supervisor. The Technical Rescue Safety Officer reports to the Rescue Group Supervisor. Trench Rescue SOG 1 August 1, 2013

Entry Team Leader: Directs disentanglement and removal operations. Controls access into the trench. The Entry Team Leader is responsible to insure that a CS Permit is filled out. The Entry Team Leader reports to the Rescue Group Supervisor. Shore Team Leader: Directs the installation of shoring and sheeting systems. The following systems may include wood, pneumatic, hydraulic or mechanical as required by the incident. This function may be assisted by operations level personnel. The Shore Team Leader reports to the Rescue Group Supervisor. Panel Team: Responsible for directing the installation of panels and all edge protection and preparation prior to the installation of the panels. The Panel Team members report to the Shore Team Officer. Extrication: Responsible for any rescue extrication that needs to be done to extricate the patient. Extrication reports to the Entry Team Leader. Hazard Control: Responsible for ventilation, atmospheric monitoring (as assigned), dewatering operation supervision. This assignment may be supported by operations personnel. Hazard Control reports to the Rescue Group Supervisor. The Thurston County Passport System will be used by all onsite personnel. All entries into a trench will follow confined space entry procedures. Anyone entering a trench will wear a class III harness and appropriate personal protective equipment. B. OPERATIONAL GUIDELINES First Arriving Units 1. Establish Command keeping emergency vehicles 100 from collapse area. 2. Size Up First arriving units will attempt to gather the following incident information: General description of the incident. Number and location of victims. Determine if it is a rescue or a recovery. Remove non-essential personnel. Identify the type of trench (straight, L, intersecting) Width, length and depth of the trench or excavation. Incident scene hazards including; disrupted or exposed utilities, flowing water, mechanical or equipment, hazardous materials or explosives, secondary collapse. Locate all utilities. Contact competent on site representatives. Trench Rescue SOG 2 August 1, 2013

3. Request SORT response as appropriate. 4. Request Law Enforcement assistance for incident scene control. Site Safety 1. No personnel shall be allowed to enter an unprotected trench to render patient care or perform disentanglement operations. All trenches shall be safe and protected using approved methods prior to entry. 2. Restrict entry and establish visible access control points. Stop and detour traffic within 300 feet of the collapse zone. Establish a hazard zone at least 75 feet around the perimeter of the collapse zone with fire line tape. 3. Shut down all heavy equipment operations. Prior to touching or moving equipment or machinery check to be sure there is no contact with electrical wires. C. Rescue Area Operations Operations Level Personnel 1. Operations level personnel are authorized to carry out the following basic activities in establishing and supporting rescue area operations. 2. Personnel shall approach the trench from the end. 3. Place ladders at each end of the trench for emergency egress. 4. Ground pad the trench or collapse site lip with plywood or other appropriate material. 5. Ventilate the trench. 6. Support any unbroken utilities. 7. Provide a helmet, goggles and oxygen (if needed) for the victim. 8. If the victim is conscious and trapped pass them a shovel so that they can attempt to selfrescue. 9. Sheeting and shoring, entry and disentanglement operations may be carried out under the direction and supervision of SORT personnel. 10. Initiate atmospheric monitoring. 11. Move spoil pile as needed to provide a clear area for ground pads. 12. Conduct debris removal from above to expose victim if possible. STOP: Await the arrival of SORT personnel and equipment before proceeding. Trench Rescue SOG 3 August 1, 2013

Technician Level Personnel Pre-Entry All Confined Space Pre-Entry procedures apply to trench recue. Prior to rescuers entering the trench, atmospheric monitoring will be performed and ventilation started. 1. The Rescue Group Supevisor will report to and work with the Incident Commander. 2. All personnel entering the trench will wear a Class III harness. Tag lines will not be worn as they can become a hazard if caught on a strut or shoring. 3. Conduct size-up if not already completed. 4. Evaluate the collapse incident site to determine appropriate sheeting and shoring requirements. Arrange for adequate materials to be on site Spoil Pile Slide The result of the excavated earth placed too close to the lip of the trench. The pile must be 2 from the lip of the trench. Slough Failure The loss of part of the trench wall that can be the result of several conditions. Trench Rescue SOG 4 August 1, 2013

Shear Wall Collapse Indicated by a section of soil losing its ability to stand and collapsing into the trench along a mostly vertical plane. Toe Failure A slough that occurs at the bottom of the trench where the floor meets the wall. As the soil falls into the trench it creates an opening at the bottom that is characteristic of a cantilever. Trench Rescue SOG 5 August 1, 2013

Water Accumulation May cause a bell pier condition. Rotational Failure A scoop shaped collapse that starts back from the trench lip and transmits itself to the trench wall in a half moon shape. ilure Wedge Failure This type of failure normally occurs with intersecting trenches. It is characterized by an angle section of earth falling from the corner of two intersecting trenches. Trench Rescue SOG 6 August 1, 2013

5. Only vactor trucks or hand methods of material removal should be used within proximity of the victim. 6. Establish plans for patient movement mechanism for removal of the patient once disentangled. 7. Evaluate the collapse site for the following special hazards: Running sand or material It may be necessary to encase the victim(s) in inter-locking drums used as an isolation tunnel. These drums should be used in the vertical position only. Horizontal placement may result in failure under the weight of the material. Other items which may be used for isolation tunnels in either the vertical or horizontal configuration are concrete, steel or corrugated pipe. Pier Holes or Caissons These bell shaped excavations are used mainly as footers to pour support columns for concrete buildings. They present an extreme danger due to the difficulty in sheeting and shoring their bell shaped bottoms. Trench and Tunnel Operations In some incidents it may be necessary to dig a trench or excavation to create a parallel shaft. Any trench cut for a rescue operation should be properly protected by either benching or sloping methods. A safe area will be established prior to personnel entering a trench. Trenches that are 4 or greater in depth will have a shore placed 1.5 2 from the top and bottom with no more than 4 between the struts Whenever possible 4x8 panels with 2x12 strong backs will be used to create safe areas. When trench walls do not allow for traditional sheeting and shoring operations then Spot shoring techniques should be used. All void areas behind panels and shores will be filled. 8. Request outside expertise, equipment and resources through the Incident Commander as required by the nature and extent of the incident. Including: Utility Company Representatives Public Works equipment and personnel Engineers 9. Plan operational activities at least two steps ahead of the operation. Have a secondary plan ready in the event that the initial tactical plan proves un-workable. 10. Provide for the regular rotation of personnel. Personnel involved in disentanglement and digging operations should be rotated as needed. Trench Rescue SOG 7 August 1, 2013

D. Patient Considerations 1. When the safe zone is established Paramedic or EMS personnel can assess the condition of the victim and provide treatment. 2 Patient should be treated for Crush Syndrome by Paramedics in accordance with Thurston County ALS Protocols. 3. Consider and threat for hypothermia. 4. Request helicopter transport to a trauma center if required. E. Termination 1. Rehab all personnel prior to termination and removal operations. 2. Debrief all personnel on the operation and its outcome. 3. Systems will normally be left in place pending Labor and Industries review. 4. If systems are removed, conduct removal operations in reverse order of placement. 5 Consider the potential for secondary collapse zones during equipment removal operations. When in doubt, leave equipment in place. No equipment is worth an injury. 6. Parallel shaft construction, tunnels or isolation tunnels should be left in place. Removing them may cause a collapse. 7. Stage, clean and inventory all equipment. Report lost or damaged equipment. 8. Identify who is responsible for backfill and when. 9. File documentation and incident report. 10. Schedule post incident analysis. Trench Rescue SOG 8 August 1, 2013

TRENCH RESCUE GROUP LEADER OPERATIONAL CHECKLIST DATE TIME_ Assign Technical Rescue incident management positions Begin Confined Space Entry Permit Develop operations plan to include an incident action plan Ensure adequate resources are on scene or en route Brief all personnel on plan of action Establish communication with logistics area and between Entry Team Supervisor and Entry Team and others as required. Provide updates to Incident Commander Rotate personnel as needed Provide for positive pressure ventilation and atmospheric monitoring Provide for de-watering systems as necessary Assure utilities are controlled and identified Limit personnel at lip and collapse zone Provide EMS as needed Get 2 sets of panels in place ASAP in order to create a safe zone for Rescue personnel Trench Rescue SOG 9 August 1, 2013