BPZM-MRD Nitrogen Injection System

Similar documents
TP Description to be used for Customer Technical Specifications

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

23.1 Functions, Basic Configuration, and Interfaces

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Portable Oil Lube Air Compressors

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Hydraulic Reliability & Preventive Maintenance Report

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

COMPRESSOR MANUAL. (888)

Inert Air (N2) Systems Manual

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

PURPOSE OF THE POLICY

NGP-250/500 Nitrogen Generator Quick Start Guide

Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices. Unit Objectives. Pressure Vessels and Piping (1 of 2)

03/07/2014 V

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Safety in Petroleum Industry

TP Description to be used for Customer Technical Specifications

GUIDELINES ON SAFE HANDLING AND STORAGE OF COMPRESSED GASES CHEMICAL MANAGEMENT CENTRE

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Pre-filter for Brushless Blower Instruction Manual

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

7.0 Compliance certificates

WHAT IS GAS TANK/CYLINDER?

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

General Precautions for handling compressed gases

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Flammable Environments Guideline

Laboratory Safety Committee

FIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO

GAS FUEL VALVE FORM AGV5 OM 8-03

There are three fuelling systems which use LNG/CNG and which may be found in vehicles today:

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

NORMAL OPERATING PROCEDURES Operating Parameter Information

SERIES & NO. SMI - 115

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Unit 24: Applications of Pneumatics and Hydraulics

EHS Laboratory Guidance: Cryogenic Material

Safety instructions and operating manual

MSDS Interspiro Spiroscape EEBD (compressed breathing air)

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Overview. OPIPOH7 - SQA Unit Code HG1X 04. Operate an Oil and Gas Process (Gas Compression)

STORAGE OF COMPRESSED GAS CYLINDERS (SAF-SPI-15)

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Number: 2015 IFC Effective Date: February 1, 2017 Page 1 of 5

SAFETY TRAINING LEAFLET 02 BASIC RULES FOR SAFETY AND GOOD HOUSEKEEPING

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS

Virtual Pipeline Emergency Response Guide

Hazardous Energy Control/Lockout

Preventive Maintenance

Electro-Pneumatic Converter YT-940 SERIES

System Pressure Manager Standard & System Pressure Manager Plus

Manual of SF6 Comprehensive Tester

Reliability Assessment of the Whistler Propane Vaporizers

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER P: REFERENCE OPERATING CONDITION STUDIES (PCC)

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Working in Gas Hazard Areas

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

PSM TRAINING COURSES. Courses can be conducted in multi-languages

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

444C DUAL PERFORMANCE VALUE PACK

NEW TYPE M PRESSURE RELIEF DEVICE

TABLE OF CONTENTS PART 2 - CONFINED SPACES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Challenges in Relief Design for Pilot Plants

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

Coriolis Mass Flow Meter

FV Flash Vessel Installation and Maintenance Instructions

ACCU-PULSE Installation and Operation Instructions

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

OPERATION MANUAL NTF-15

Minimum standard of competence in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2)

400C & 450C DUAL PERFORMANCE VALUE PACKS

EGL-12 OIL-LESS COMPRESSOR

Pressure Piping Code-Industrial Piping. Part 6: Safeguarding

Installation of Ballast Water Management Systems

Oxygen Usage Best Practice Guide

Annual Report on High Pressure Gas Related Accidents (2016 version)

APPS-160 Gen 2 User Manual

OPERATION MANUAL NTF-60 Plus

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

Maintenance handbook

Safety Powder Spray Systems

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

ChemiPPR. Response of hazardous materials LAMK. Sakari Halmemies 26 Sep2016

200 PSI COMPRESSORS - MODEL NUMBERS

Impact on People. A minor injury with no permanent health damage

100C Air Compressor Kit

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

On-Stream Tightness Testing of Vacuum Process Installations

Transcription:

BPZM-MRD Nitrogen Injection System (Transformer protector) Overview BPZM-MRD Nitrogen Injection Explosion Prevention & Fire Protection System became more advanced fire protection and explosion prevention system for the Oil immersed transformer protection after "Water Spray System" and "CO2 Spray System", FMD Systems were also examined by "National Fixed Fire Extinguishing Systems and Components Quality Supervision and Inspection Center" and passed the test as qualified. Transformer are among the most expensive equipment located in power plants and substations. They generally contain a large quantity of combustible substance, which can spray fire to nearby installations and caused a power failure and huge economic losses. Special attention should therefore be paid to their protection. The traditional protection of transformer usually focuses on the electric parameters of the transformer, while the sudden pressure increased within the tank resulting from insulation breakdown does not draw much attention. Principle of Explosion Prevention: If the transformer is not working properly, an enormous amount of flammable gases will be created in the oil tank. As a result, the gas relay closes and the electric breaker switches off. At this moment, the internal pressure of the tank increases due to the

thermal inertia. Once the pressure exceeds the setting value of the pressure relief valve (PRV) and the setting value of rupture disk, BPZM-MRD Nitrogen Injection system is operated immediately. Consequently, the oil drain valve opens to draw off oil in order to relieve the pressure inside the tank and prevent any explosion and fire. Principle of Extinct Fire: When the transformer is on fire, the fire detector is activated, the gas relay closes, and the electric breaker switches off. As a result, BPZM-MRD Nitrogen Injection system is operated and the oil drain valve opens to draw off oil. Then nitrogen gas is continuously injected, the large amount nitrogen gas sufficiently cools down the transformer, extinguishes fire, and prevents any re-combustion. Working Conditions: 1, Fire detector, drain valve, fire protection cabinet could be located outdoor. Control panel should be located indoor. Around the site there should be no violent vibration and shock, no corrosive gas. 2, Ambient Temperature A) outdoor application: -40 ~ 60 B) indoor application: 5 ~ 30 3, Relative Humidity A) outdoor application: 95 (@ 20 ±5 ) B) indoor application: 85 (@ 20 ±5 ) 4, Power Source Working power source:dc220v or DC110V Functions: Explosion Prevention and Fire Extinguishing The system can extinguishing the fire immediately thro injected the N2 gas into the Transformer Tank. The Nitrogen can be injected continuously for 30 mins to stir and cool down the transformer oil, which also isolated the air from the tank. Characteristics of BPZM-MRD Nitrogen Injection System: State-of-art concept: rapidly drain oil to prevent explosion and inject nitrogen to prevent and extinct fire.

Excellent performance: utilizing fast valves to drain oil in 0.1s with the technic from the national defence. Fast response: once a fault signal is detected from the transformer. The oil is drained within 0.2 second after detection in order to release pressure and to avoid explosion. The nitrogen gas is injected after 1 to 20 second in order to mix and cool down the oil, to reduce the concentration of flammable gases, to isolate oxygen gas, and to extinct fire.high reliability: utilizing the principle of logic signal to prevent any improper or unnecessary activity to the system and to provide a more flexible system. High efficiency: able to inject nitrogen gas continuously for more than 30 min to completely cool down the transformer oil as well as prevent and extinguish fire. Reduce pollution: no environmental pollution due to the characteristic of nitrogen gas in FMD. Extinct fire without water is an advantage to the lack of water area. Feasibility: easy to install and maintain for both new or existing transformers with reasonable investment in a minor price compare to other traditional transformer fire extinction systems, such as water spraying systems and CO2 spraying systems. Scope of applications: Generator power unceasingly increase with the development of technology, there are many transformer explosion happened due to ineffective of current breaker between the Generator and Power Transformer. BPZM-MRD Nitrogen Injection System is suitable for new or remodeled power transformer which located in the high power plant, substations, indoor substations, underground substations, city substations and cold and water-deficient area. Information Required to Quote 1, layout drawing, contact details of transformer manufacturer and system designing company. 2, if any special requirement, please indicate.

Appendix Transformer Capacity(MV.A) 50 >50, 360 >360 Volume of N2 (L) 40 40 63 No. of N2 Bottle 1 2 2 Initial Pressure of N2 Bottle (MPa) 15 15 15 Pressure after Decompression (MPa) 0.6 0.6 0.6 Volume of N2 after Decompression (L) 1000 2000 3150 Continuous Time of N2 Injection (min) 31 31 31 Valve Outlet after N2 Injection Stir (L/min) 32.25 64.51 101.61 Flow Speed of N2 in the bottle (m/s) 1.095 2.19 3.45 N2 Injection hole number 2 4 6 Flow Speed of Injection Hole (L/min) 16.13 16.13 16.94 1, Nitrogen Quantity of Three Different Transformer Capacity.

2, Sketch Drawing of the Fire Protection System Transformer Fire Protection Cabinet Main Control Room Auto-Control System Accident Oil Pool