Grove - Gas Sensor (O2)

Similar documents
12/07/2016 Grove Gas Sensor(O₂) Wiki

Grove - Gas Sensor(MQ9)

Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω

Electrochemical Sensor

Electrochemical Sensor

ME3-HCL Electrochemical sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Preparation for Salinity Control ME 121

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

living with the lab control of salinity 2012 David Hall

Transmitter CS 21 Operation Manual

MODEL GT820 OXYGEN SENSOR

Oxygen Meter User Manual

Transmitter CS 21 Operation Manual

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Written Report of Robot Design

APA software instruction manual

210 Series Transmitter with External Electrochemical Sensor

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

NEULOG OXYGEN LOGGER SENSOR GUIDE

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Mass Flow Controller (MFC) for Gases

Additel 761 Automated Pressure Calibrators Selection Guide

Operation manual Oxygen sensor

Technical Data Sheet MF010-O-LC

PERME- OX2/230 Oxygen Transmission Rate test system

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Additel 761 Automated Pressure Calibrators

GasSense NDIR User Manual

Additel 761 Automated Pressure Calibrators Selection Guide

Phosgene Sensor. Sensoric COCl2 3E 1

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

ADT 761 Automated Pressure Calibrator

Panther 5 Acute Care Ventilator

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Digital dead-weight tester Model CPD8500

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Digital deadweight tester Model CPD8500

Control of Salinity in the Fish Tank ME 121. Tank Pump Sensor. Figure 1 Schematic of flow loop and salinity control scheme for the fish tank.

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

FTC130 Transmitter. Operating Manual

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

DDR Dive Data Recorder Manual - Rel /12

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Application Note AN-107

AUTO PUMP STATUS CENTER

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Mass Flow Controller (MFC) for Gases

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Additel 780 Series Pressure Controller

RG2 Gripper Datasheet Version 1.6

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Experiment B-3 Respiration

LifeBeat should be worn during daytime as well as night time as it can record activity levels as well as sleep patterns.

Fixed Ozone Monitor User Manual December, Automatikprodukter

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

2/2-Way Solenoid Control Valve

Mass Flow Controller (MFC) for Gases

Additel 780 Series Pressure Controller

Return Policy / Procedures

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Meditation Trainer. Created by Collin Cunningham. Last updated on :36:45 PM UTC

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

EPP4 Pressure Regulator Basic G 1/4"

Technical Information Conducal CLY421

Miniature Electronic Pressure Controllers. Precision Fluidics

KEM Scientific, Inc. Instruments for Science from Scientists

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Easy to operate. Wide space

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

OC508 Programmable mv Calibrator

BUYER S GUIDE AQUAlogger 530WTD

Over 80 years of experience in precision weighing and UniBloc technology

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

Electronic gas volume corrector model DGVC-04

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

HumiSys HF High Flow RH Generator

MANUAL KPS Pressure Control Valve

Installation and Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual

BekkTech s Procedures For Performing In Plane Membrane Conductivity Testing

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Overview. Front Panel: Keypad and Display

TR Electronic Pressure Regulator. User s Manual

Datasheet: K-30 ASCII Sensor

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Mass Flow Controller (MFC) for Gases

Transcription:

Grove - Gas Sensor (O2) Release date: 9/20/2015 Version: 1.0 Wiki: http://www.seeedstudio.com/wiki/grove_-_gas_sensor(o%e2%82%82) Bazaar: http://www.seeedstudio.com/depot/grove-gas-sensoro2-p-1541.html 1

Document Revision History Revision Date Author Description 1.0 Sep 21, 2015 Victor.He Create file 2

Contents Document Revision History 2 1. Introduction 2 2. Features 3 3. Specifications 4 4. Usage 5 5. Resources 8 3

Disclaimer For physical injuries and possessions loss caused by those reasons which are not related to product quality, such as operating without following manual guide, natural disasters or force majeure, we take no responsibility for that. Under the supervision of Seeed Technology Inc., this manual has been compiled and published which covered the latest product description and specification. The content of this manual is subject to change without notice. Copyright The design of this product (including software) and its accessories is under tutelage of laws. Any action to violate relevant right of our product will be penalized through law. Please consciously observe relevant local laws in the use of this product. 1

1. Introduction Grove-Gas Sensor (O₂) is a kind of sensor to test the oxygen concentration in air, which is based on the principle of the electrochemical cell to the original work. You can know clearly the current oxygen concentration when you output voltage values proportional to the concentration of oxygen and refer to the oxygen concentration linear characteristic graph. It s very suitable for detecting oxygen concentration in the environment protection. Grove - Gas Sensor(O₂) is an organic reaction module, it can provide a little current while putting it in the air, we don't need to provide an external power to it, and output voltage will change as time current changes. 2

2. Features High-precision High sensitivity Wide linearity range Strong anti-interference ability Extraordinary reliability 3

3. Specifications Items Measurement Range Detect Life Sensitivity Temperature Range Pressure range Response Time Humidity range Parameter 0-25%vol two years 0.05~0.15 ma(in air) -20 ~50 QNE±10 % 15S 0~99 % RH Non-condensing Stability <2% 4

4. Usage That requires us to use the analog port of Arduino to take the readings. We have converted the read value to the corresponding concentration of O2. It's more convenient for you to get a value of O2 directly without watching the figure. Notice: Please power the Gas Sensor(O2) more than 48 hrs before you get data from it. Here is an example of concentration control Buzzer. When Oxygen concentration gets lower than the minimum safe concentration, the Buzzer will sound. 1. Connect the module to the Analog port 0 of Grove - Basic Shield using the 4-pin grove cable and connect Buzzer to Pin 3. 2. Plug the Grove - Basic Shield into Arduino. And connect Arduino to PC by using a USB cable. 3. Copy and paste the code below to a new Arduino sketch. Please click here if you do not know how to upload. #include <math.h> const int buzzerpin=3; //Connect the Buzzer Grove module to Pin3, Digital 3 float WarningValue= 19.5; //The minimum sate concentration of O2 in air void setup() { Serial.begin(9600); //Start the Serial connection } void loop() { //long unsigned a; float sensorvalue; float sensorvoltage; float Value_O2; sensorvalue = analogread(a0); sensorvoltage =(sensorvalue/1024)*5.0; sensorvoltage = sensorvoltage/201*10000; Value_O2 = sensorvoltage/7.43; Serial.print("Concentration of O2 is "); Serial.print(Value_O2,1); Serial.println("%"); if(value_o2<=warningvalue) { digitalwrite(3,high); 5

} } } else digitalwrite(3,low); delay(1000); 4. When the sensor is in air, the buzzer will not sound. You can blow toward the sensor, at this time, if Oxygen concentration is lower than threshold we set, the Buzzer will sound. You can check the output voltage (amplify 201) after opening the Serial Monitor. We tested it in an office, so the concentration of O2 is about 20.5%. Notice: We have adjusted the figure in a clear air, and we have updated it in the program, please refer to the program instead of datasheet. 6

7

5. Resources Grove - Gas Sensor(O2) Eagle File Schematic in PDF File:ME2-O2.pdf -- Sorry, It's written in Chinese but it's better than none. 8

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Seeed Studio: 101020002 101020078