Figure 4 Figure 5 Figure 6

Similar documents
The Advancement of Pressure Independent Technology

Hydronic Systems Balance

Modulating Flow Control with Mesurflo

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

TESTING OF BELIMO PRESSURE INDEPENDENT CHARACTERIZED CONTROL VALVES

Gerald D. Anderson. Education Technical Specialist

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

FloCon Commissioning Modules DESIGN GUIDE - JUNE Variable Flow Systems & Solutions brought to you by Hurlstones

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Some system examples

RadKits (Piping Packages)

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

my SYSTEM A guide to common applications in water distribution systems

SINGLE VALVE WITH LOW-FLOW BYPASS

Back to Basics: Pumping Systems RM ASHRAE TECH CONFERENCE

Application Block Library Fan Control Optimization

TECHNICAL DATA. than the water inlet pressure to the concentrate

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

The Ins and Outs of I/P Transducers

Aquavar SOLO 2 Frequently Asked Questions

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design

Waterous Relief Valve

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Discharge Relief Valve Operation & Maint.

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

CONTROL VALVE WHAT YOU NEED TO LEARN?

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Advanced Pump Control for Irrigation Applications

Chapter 10: Bidirectional Flow Controls

Pressure Independent Control Valves

Characterizers for control loops

ELECTRONIC VALVE SIZING AND SELECTION

OIL AND GAS INDUSTRY

Process Dynamics, Operations, and Control Lecture Notes - 20

User Manual for the Mars Calibration Bench

Expansion Tank Design (Chilled Water)

Residential Pressure Booster Systems

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Model 130M Pneumatic Controller

Union joints 23. Fulfilling Solutions Through Knowledge

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Sapag Control valve MONOVAR

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

553 Series.

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

BACK PRESSURE / SUSTAINING

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Lesson 6: Flow Control Valves

PROCESS MONITORING AND CONTROL

Rate of Flow Valve Series 120

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Full Range Pressure Compensating Variable Flow Control

BACK PRESSURE / SUSTAINING

Manual for continuous distillation

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Two Sides of the Same Coin

BUBBLER CONTROL SYSTEM

A Chiller Control Algorithm for Multiple Variablespeed Centrifugal Compressors

Engineering Note. Algorithms. Overview. Detailed Algorithm Description. NeoFox Calibration and Measurement. Products Affected: NeoFox

1. Study the performance of a binary distillation column operated in batch mode.

ENS-200 Energy saving trainer

Reverse Osmosis System Installation Guide and Operation Manual.

Fail Operational Controls for an Independent Metering Valve

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

Engineering Letter. Pump Protection

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

Model: 43T. Bermad Pressure Relief Valve

Constant Pressure Inlet (CCN) Operator Manual

Cable Pressurization Buffering

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

HERZ-Motorised flow controler

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Pressure independent control valve (PICV) FLOWMATIC

KELCO F60 DIGITAL PUMP CONTROLLER

Control System Nur Istianah-THP-FTP-UB-2014

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Pressure Independent Control Series

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Powers Controls RC 195 Multiple Input Receiver- Controller

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

Transcription:

PICCV versus conventional two-way control s A with an equal percentage characteristic has historically been used to counteract the nonlinear heat emission of the coils. The result is a linear heat emission versus the opening. This is a prerequisite for a stable control and a low proportional band of the control system. See Fig. 1, 2 and 3. Unfortunately this situation is only true when the pressure is held constant as the goes from closed to open. This is a condition that exists in a laboratory condition only. Heat Emission 0% 100% Typical coil characteristic Belimo CCV Resulting heat output is linear. flow Degree Opening characteristic = equal percentage 100% The flow rate of a conventional two-way depends upon both the degree of opening and the pressure. For example: a that is 50% open and supplies 5 GPM at 4 PSI, will at 36 PSI, supply 15.0 GPM at the same opening. When a conventional two-way control opens or closes, it causes pressure changes in the system. Often the pressure changes are quite large, and this causes a severe distortion of the s ability to control. When all the s are open the differential pressure is very low, but as they close the pressure increases more and more. Eventually the full pump pressure exists over the s. The differential pressure across the s increases quickly as the flow is reduced. This is due to the quadratic nature of the losses in the pipe, coil and other system components. See Fig. 4, 5 and 6. These pressure changes cause a severe distortion of the characteristic and its ability to control in a stable manner. FLOW BTU/H BTU/H Heat output/valve opening 50% 50% 20% 0 50% OPENING 20% FLOW 0 50% OPENING Figure 1 Figure 2 Figure 3 100% Differential pressure PSI 60 FLOW HEAT EMISSION 50 ON-OFF ON-OFF COIL COIL CONTROL VALVE BALANCING VALVE CONTROL VALVE BALANCING VALVE DIFFERENTIAL PRESSURE ACROSS THE VALVE 40 30 20 EQUAL PERCENT CURVE ON-OFF COIL CONTROL VALVE BALANCING VALVE 10 PUMP 0 BOILER/CHILLER 100% FLOW 90 80 70 60 50 40 30 20 10 0 100% 0 Figure 4 Figure 5 Figure 6

The PICCV s are used as a replacement for conventional two-way control s, but offer a very important new feature. It will regulate the flow rate regardless of the differential pressure. In other words, it is a true flow controller. It consists of a differential pressure regulator in series with a control. The differential pressure is held constant over the control. This is what gives a specific flow for each degree of opening, regardless of the differential pressure over the whole PICCV. The pressure changes before and after the PICCV are absorbed by the pressure regulator, so the differential pressure across the control remains constant. See Fig.8.. The flow rate of the PICCV depends only upon how much the actuator has opened the. The pressure has no importance. (Within the range of 6 50 PSI.) The actuator modulates the PICCV to a required flow rate, independent of the pressure. This more stable flow means less work for the actuator, thus increasing actuator life. Figure 7 1/2" PICCV 3GPM 4 3.5 3 2.5 (GPM) 2 1.5 1 0.5 0 0 5 10 15 20 25 30 Delta P (PSI) 10V 9V 8V 7V 6V 5V Figure 8

PICCV versus a conventional pressure dependent control There are several factors that contribute to a conventional control not being able to control well in a system. They include: Figure 9 Constant speed pumps The pressure over a regular control can vary greatly. For example: from 4 psi at full flow, to 36 psi at 25% flow. The pressure change a control is subject to when it is operated from open to closed is called authority. A poor authority distorts the resulting flow characteristics so it is no longer equal percentage. The flow is no longer controlled gradually, but increases quite dramatically especially in the beginning. The result is very dramatic when the flow is applied to a coil. For example, a 10% degree of opening of the, equals to a 15% flow, which translates to a 50% BTU output from the coil. At low loads the system most certainly will hunt. The question is not if the control system will hunt, but how small loads the system can control in a stable manner. See Fig. 9. The PICCV on the other hand, is unaffected by any pressure changes and gives an equal percent control of the flow in the beginning and there after an essentially linear characteristics. This characteristics looks the same at low and high pressures and is unaffected by the authority. See Fig. 10. The concave flow control matches the convex coil characteristics and the result is an essentially proportional output change of the heat emission- regardless of any pressure changes. 0 100% Equal percent characteristics. characteristics Heat emission/ position Valve Valve 0 100% Combination coil and control characteristcs gives a linear heat/cooling output. Variable speed pumps Figure 10 Variable speed control is an improvement, but does not completely eliminate the pressure variations at the control s. See Fig. 11, 12 and 13. The conventional control located near the pressure sensor for the pump control has conditions that is favorable. The problem arises with the other s, especially the as far away from the sensor as possible. Figure 12 High load 10 psi Figure 11 Low load 10 psi Figure 13 variable speed drive 40 psi High load = Large pipe losses. Boliler or Chiller Low load = Very small pipe losses.

Example: set point for pressure control = 10 psi. Pressure drop at full load is 30 psi between supply and return. This means that the pressure at the first is 30+10 = 40 psi at full load. At low loads on the other hand, the pressure approaches 10 psi, as the pipe losses goes down by the square. At full load (40 psi) we will have problem with a poor authority for the first s, and at low loads (10 psi) we can not supply the full flow. GPM Automatic balancing Figure 14 The use of the PICCV eliminates all difficulties associated with these systems. 2volt %Open 10 volt Control Valve in Combination with a Limiting Valve. Several manufacturers have a control built together with an automatic flow limiting. This must not be compared with a PICCV! This combination behaves exactly as a conventional control. Only when the maximum flow rate is reached, will the limit the flow. GPM Varying pressure. Restricted working range. Automatic balancing See Fig. 14. It shows an example of the normal behavior of the control when the pressure is low. See Fig. 15. It shows the behavior when the pressure is high and there is a call for full flow. Figure 15 With conventional control it is next to impossible to size the control s correctly. A high differential pressure should be used to size the s, so that a good authority can be achieved. However, the caveat is that it requires a much larger pump. The s are typically sized for a low pressure drop at maximum load. The issue is that they normally work at a much lower load, where the pressure is much higher. 2 volt %Open 10 volt High pressure. The reaches the flow linit early so a large portion of the operating range becomes uneffective. Figure XXX shows the operation of a combination as well as the PICCV. As you can see, the limiting acts as a conventional control (within its differential pressure limit of2-14 PSI) and then resumes the action of a conventional control with higher differential pressures. Belimo PICCV vs. Automatic Limiting Valve 9 8 Rate (GPM) 7 6 5 Belimo PICCV, 6GPM Automatic FLV, 5 GPM 4 Figure XXX 3 0 10 20 30 40 50 60 Differential Pressure (PSI)

Balancing Valve The PICCV performs balancing of the system because the maximum flow is limited. Typically, the actuators for the PICCV will go to the maximum position during start-up. The rated maximum flow for each PICCV will be provided. When sizing the PICCV, a with a rated maximum flow that is equal to or just higher than the desired flow is selected. There are several ways of limiting the flow and this creates a broad range of available flow rates. Therefore, no significant overflow will result in the system during morning start up. The average overflow will be very small. For _" s and higher, the average overflow will be less than 15%. For _" s, the percentage is higher, but the flow rate is so low that little effect will be seen. The overflow is estimated at less than 10% for the total installation, depending upon the mixture of s. This overflow situation will last only for a short time during start-up. Manual balancing s publish an accuracy of +/-3%, but that is under special conditions, where the s are adjusted near full open. Small balancing s (1/2" and _") tend to be oversized versus the desired maximum flow so these balancing s need to be turned down much, where their accuracy is lowered. This situation compiled with a conventional will give more than a 10% overflow during morning start-up. A note on Balancing Valves: Balancing s are not needed with the PICCV and can be replaced by shut-off s or a strainer/shut-off combination. accuracy at reduced flows. In addition, no extra cost is involved when using the PICCV as a flow meter. When the flow is known, it is a simple matter of measuring the temperature after each coil and one temperature in the supply. Using this differential temperature, the energy consumption can be calculated and displayed by the EMS system. By measuring the energy consumption, the cost for running each terminal or a group of terminals can be established. Therefore, the energy cost for each tenant can be established. This gives the ability to have a true energy management system, as you can measure the energy and see where and when it is consumed. This will prove to be an important feature as the cost for energy is likely to rise in the future. Less Complex Piping Systems The PICCV makes it possible to use simpler and less expensive piping solutions. It eliminates bypass lines that contribute to a poor differential temperature "delta T" in the system. Instead, all the flow that leaves the chiller or boiler will pass through a coil, which will allow for a large differential temperature "delta T". Elimination of Three-Way Valves See Fig. 18 and 19. Instead of using three way s, PICCV should be used, changing the system from constant flow, to a variable flow system. All the bypasses are eliminated, improving the differential temperature "delta T" considerably. In addition, the installation cost is reduced. However, if manual balancing s already are installed in the system, they can remain. Balancing s will only limit the maximum flow when the PICCV is fully open, for example during morning start-up. At any time, they will not effect operation. Balancing s, if present, should be sized after the maximum flow rate so they do not need to be turned down very much. shut off balancing 3 Way control balancing If desired, a main balancing can be installed after the pump, to regulate the maximum flow in the system, but this is optional. Measurement /Energy Management If a proportional actuator or three-point actuator with a 2 10 VDC feedback is used, the signal can be used for flow measurement, which can be displayed for each terminal. Every volt of control or feed back signal corresponds to a specific flow when a PICCV is used. A table in the DDC system translates volt to flow. The flow information is displayed for each terminal. The accuracy is about +/-10%. The accuracy PICCV compares favorably with turbine, paddle wheel, venturi and orifice type flow meters. These could have better accuracy at full flow, but at reduced flow their accuracy is decreased. PICCV s maintain their with three way. Figure 18 shut off with. Figure 19 shut off

Example of savings in material and installation is as follows: To install a 3-way, it requires: Item Pieces 1 Balancing 2 Three way 1 Couplings 14 Lengths of pipe 8 Large pump Figure 16 Large pump To install a PICCV, it requires: Item Balancing 0 PICCV 1 Couplings 8 Lengths of pipe 3 Pieces 2 (1 piece could be shutoff /strainer combination) Variable speed drive. Check Check Large pump As one can see, the installation costs can be reduced significantly. Smaller Pipes Smaller pipes can sometimes be used, because the effect of increased pipe losses can be accepted, because PICCV s are unaffected by pressure changes. Reset of the Supply Temperature. Reset of the supply water temperature with respect to the outdoor temperature can be eliminated, or the reset schedule can be less aggressive. This makes it possible to mix terminals for outside zones with terminals for interior zones on the same supply line. This can result in substantial savings in the piping. Control See Fig.16 and 17. Instead of using two large pumps, it is possible to use one large pump and one smaller pump. The large pump is used for start up situations and when the system operates under maximum load. The system switches automatically as soon as the load has gone down so much that the small pump can be used. The PICCV s are unaffected by the sudden change in pressure. NOTE: If this is attempted with conventional control s, you introduce a very large disturbance to the system at a time when the load is fairly large. This is not advised. The large pump is constant speed. The small pump may have optional variable speed drives. Example: Large pump, 50 HP @ 40 psi. Smaller pump, 5 HP @ 15 psi. Figure 20 Figure 21 Small pump Figure 16 Boiler or Chiller Riser 1 Riser 2 Balancing Conventional pipig arrangement. Riser 1 Riser 2 Balancing Primary/Secondary ing See Fig. 20 and 21. Instead of using one main pump for the header, and then one for each riser, only one central pump is used. Boiler or Chiller Piping arrangement using only one pump.

The bypass lines in the risers and all other bypass lines should be eliminated. This translates to improved differential temperature "delta T". Chiller Control. See Fig. 22 and 23. In a chiller we must maintain a certain minimum flow. Traditionally, this is done by a simple bypass line, but it results in a poor differential temperature "delta T" for the chiller, especially at light loads. The following set up eliminates or reduces the bypass flow to a minimum, over the whole operating range of the chillers. Suppose that three chillers are used, and the chillers can accept a flow that is reduced by a maximum of 25% (to 75% flow). Install one flow sensor in the supply line. It sequences the chillers so the chillers are started a 1/3, 2/3 and 1/1 load. Chiller Chiller Chiller Bypassline Traditional solution results in low delta T. Figure 22 Supply Water Return Water Install a bypass line with a control. Install a second flow sensor between the bypass line and the chillers. The control is closed between 100% - 75% flow. Between 75% - 66.7% the second flow sensor control the flow trough the control, and in doing so maintains a constant flow trough the three chillers. The third chiller is switched off at 66.6%. The control is closed between 66.6% - 46.6%. Between 46.6% - 33.3% the control control the flow through the, and in doing so maintains a constant flow trough the two chillers. The second (and third) chiller is switched off at 33.3%. The control is closed between 33.3% - 23.3%. Between 23.3% - 0% the control controls the flow through the, and in doing so maintains a constant flow through the chiller. Certain boilers may also benefit from a similar installation. sensor Chiller 1 Chiller 2 Chiller 3 Control Bypassline Controller Figure 23 sensor