Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Similar documents
Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Throttle Cartridges, Size 16

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure-Relief Cartridge Valve, Size 4

Cooler-Bypass Thermostat Valve, Size 16

Double Pilot Operated Cartridge Check Valve, Size 8

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Leak-Free Load-Control Valve SAE ½ psi flange

PRESSURE COMPENSATORS TECNORD

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Pressure reducing valve, direct operated

Leak free Pipe Rupture Valve for Excavators

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Pressure reducing valve, pilot operated, Model 3DR

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Leak-Free Load-Control Valve, Size 20

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

3-Way Safety Block DSV

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Proportional Directional Valve System

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

Cover headline. Cover subheadline. Check Valves

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Safety and Shut-off Block SAF/DSV

Check valve hydraulically pilot operated

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Solenoid valves VZWF, force pilot operated

D62 - D63 Directional Control Valve l/min

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Safety and Shut-off Block SAF/DSV

Directional Controls

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Series K Air service units G 1/8, G 1/4

SDM to 8 sections monoblock valve D1WWDA02A

The Size 16 Product Range

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure relief valve, direct operated

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Safety and Shut-off Block SAF/DSV

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Air service units series K G1/8, G1/4

SPCH/ Blowing block

4/2 way Pneumatic Solenoid Valve

Pressure Reducing Valves Catalog Quick Reference

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

PRESSURE SEQUENCE VALVE TYPE UZK

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Directional Valves. Hydraulic Operated Directional Valves

Intrinsically safe solenoid valves on/off controls - ATEX certification

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Cartridge Valves Technical Information Proportional Valves Quick Reference

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Safety and Shut-off Block SAF/DSV

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Full Range Pressure Compensating Variable Flow Control

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Safety and Shut-off Block SAF/DSV

Applications. What moves your world

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

SOLENOID VALVES AND PNEUMATIC VALVES

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Pressure relief valve, direct operated Type DBD

Axial Piston Variable Pump A10V(S)O (US-Version)

Pneumatic valve islands

Fixed Displacement Motor A4FM

PVQ 13 A2 R SE 1 S 20 C-11 D

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Axial piston pumps type PVC

Monoblock directional control valves ML - Directional control valve

Axial piston pumps type PVC

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Pressure relief valve, direct operated

PLD 03 T A CASAPPA S.p.A.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Chapter 10: Bidirectional Flow Controls

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

VSD03M DIRECTIONAL CONTROL VALVES

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Transcription:

Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size / SAE 8, high performance screwin cartridges with an /4-16 UNF mounting thread. They reduce the outlet pressure in as a function of the control current signal and independently of the inlet pressure in 1. In the initial position (solenoid de-energised) the inlet of the -way pressure-reducing cartridge is shut off and the outlet is connected to tank (port ). In control mode, the connection 1 opens until the pressure in port reaches the preset level. If the pressure rises above the preset level, the control spool opens the connection until balance is attained. Two pressure ranges are available, with maximum Compact construction for cavity type AM /4-16 UNF Operated by a proportional solenoid pressure ranges available Excellent stability over the whole pressure and flow range All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body operating pressure (inlet pressure) p max bar. These -way pressure-reducing cartridges are predominantly used for reducing a system pressure in mobile and industrial applications. Thanks to the special terminal assignment, a proportional function can be achieved in manifold control blocks featuring WK... valves by using these valves in a way that does not require any redesign of the block. All external parts of the cartridge are zinc-nickel plated to DIN 979 and are thus suitable for use in the harshest operating environments. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol Technical data General characteristics Designation proportional -way pressure-reducing cartridge Design direct acting, electrically operated Mounting method screw-in cartridges /4-16 UNF Tightening torque 4 Nm ± 1 % ( ft-lbs ± 1 %) Size nominal size / SAE 8, cavity type AM Weight.4 kg (.9 lbs) Mounting attitude unrestricted (preferably vertical, coil down) Ambient temperature range - C + C (-1 F +1 F) Reference: 4-P-911-EN- Issue:.17 1/

Hydraulic characteristics Maximum operating pressure bar (6 psi) Maximum flow rate 1 l/min (4 gpm) Nominal pressure ranges 4 bar, 7 bar (64 psi, 1 psi) Flow direction see symbols Hydraulic fluid HL and HLP mineral oil to DIN 1 4; for other fluids, please contact BUCHER Hydraulic fluid temperature range - C +7 C (-1 F +18 F) Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 446 : 1999 1 8 mm /s (cst), recommended...1 mm /s (cst) class 18/16/1 Electrical characteristics Supply voltage Control current Coil resistance R - cold value at C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Switching time Relative duty cycle Protection class to ISO 6 / EN 6 9 Electrical connection 1 V DC, 4 V DC 1 V = 14 ma, 4 V = 76 ma 1 V =.8 / 4 V =.9 1 V = 9.1 / 4 V =.7 Hz 6 % I N 6 % I N < % I N < % p N see performance graphs 1 % IP 6 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) -pin square plug to ISO 44 / DIN 4 6 (standard) for other connectors, see Ordering code / 4-P-911-EN-/.17

4 Performance graphs measured with oil viscosity mm /s (cst) p = f (I) Pressure adjustment characteristic p [bar (psi)] 8 ( 11) P49.ai 6 (86) p N 7 bar (1 psi) 4 (7) (8) p N 4 bar (64 psi) 1 4 6 7 4 6 8 1 1 14 I [ma] p = f (Q) Pressure - Flow rate characteristic p [bar (psi)] 1 P4.ai p N = 7 bar p [bar (psi)] (17) 9 (1) p 1 = bar (6 psi) 6 (86) (4) 1 7,., 7, 1 1, 1 (.6) (1.9) (1.) (.6) (.6) (1.) (1.9) (.6) (.) (4) Q [l/min (gpm)] p = f (Q) Pressure - Flow rate characteristic p [bar (psi)] 8 P41.ai p N = 4 bar p [bar (psi)] (11) 6 4 p 1 = bar (6 psi) (86) (7) (8) 1 (.6) 7, (1.9) (1.). (.6). 7, 1 1, 1 (.6) (1.) (1.9) (.6) (.) (4) Q [l/min (gpm)] 4-P-911-EN-/.17 /

Dimensions & sectional view 7 4 8. 1 6 /4 16UNF 4 81 119. Ø 6 1 4 M A = 4 [Nm] ± 1 % ( ft lbs ± 1 %) M A =.7 [Nm] ± 1 % ( ft lbs± 1 %) 6 Installation information IMPORTANT! When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. Seal kit NBR no. DS-47-N 1) Item Qty. Description 1 1 O-ring 18, x, FKM ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. IMPORTANT! 1) Seal kit with FKM (Viton) seals no. DS-47-V 1 O-ring no. 17 17,17 x 1,78 N9 1 O-ring no. 14 1,4 x 1,78 N9 4 1 O-ring no. 1 1,8 x 1,78 N9 O-ring 16, x, FKM 6 Backup ring 1.7 x 1.4 x 1.4 FI71 7 Backup ring 9.4 x 1.4 x 1. FI71 4/ 4-P-911-EN-/.17

7 Ordering code Ex. DRD S A - 7 M - 7 - _ - 1 4 D _ DRD = direct acting, prop. pressure-reducing cartridge S = standard solenoid (proportional) A... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER 7 = -way pressure function (external pilot drain) M = cavity type AM 7 = pressure range 7 bar (1 psi) 4 = pressure range 4 bar (64 psi) = nominal size (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) 1... 9 = design stage (omit when ordering new units)... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 44 / DIN 4 6 connection with mating plug (standard, IP 6) M1 = ISO 44 / DIN 4 6 connection without mating plug C = Kostal plug connection (IP 6) JT = Junior Timer radial plug connection (with protection diode, IP6) IT = Junior Timer axial plug connection (with protection diode, IP6) D = Deutsch plug connection DT4-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT4-P (with protection diode, IP 67/69K) S = AMP Superseal 1. (IP67) / Metri-Pack 1 (IP6) plug connection F = flying leads ( mm) 8 Related data sheets Reference (Old no.) Description 4-P-411 (i-) The form-tool hire programme 4-P-4181 (i-.11) Cavity type AM 4-P-111 (W-.141) Coils for screw-in cartridge valves 4-P-111 Amplifier unit for proportional valves (1-channel) PBS - A 4-P-1111 Amplifier card for proportional valves (1-channel) SAN- 4-P-7111 (G-4.) Line-mounting body, type GAMA (G /8 ) info.ch@bucherhydraulics.com www.bucherhydraulics.com 17 by Bucher Hydraulics AG Frutigen, CH-714 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 4...1 4-P-911-EN-/.17 /