Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP

Similar documents
MANUAL KPS Pressure Control Valve

Measuring range Δp (span = 100%) Pa

Installation, operating and maintenance Instructions for Seemag bypass level indicator

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

GasSense NDIR User Manual

ASDX Series Silicon Pressure Sensors

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

Installation, use and maintenance instructions. Gas burner (5)

Model PDT Dewpoint Transmitter

Installation and Operation Manual

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

GATE 2 Part No

AMS 2710 PCB pressure sensor module with V output

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

2/2-Way Proportional Valve (motor-driven)

Instruction and Maintenance Manual

Transmitter CS 21 Operation Manual

ATM.ECO - Analog Pressure Transmitter

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Instruction and Maintenance Manual

Columbus Instruments

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

INSTALLATION,OPERATION AND MAINTENANCE INSTRUCTIONS DRY AIR COOLER

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Ventam 85 Installation & Commissioning Instructions

BUBBLER CONTROL SYSTEM

Variable Area Flow Meters

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Standard 1/4 compressor chiller/heat pump with heating recovery Manual version: /02/97

Digital electro-pneumatic regulators Series ER100

Prestige Solo Prestige Excellence 24-32

High-performance submersible pressure transmitter For level measurement Model LH-10

Stand-Alone Bubble Detection System

Manual Oxygen Analyzer A4009T

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

SX150A. Features. Typical Applications. Description

Aquavar SOLO 2 Frequently Asked Questions

HS653 Negative Pressure Ventilation Controller

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Technical Data. Dimensions

Standard Chiller 1/4 compressors Manual version: /10/96

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

AUTO PUMP STATUS CENTER

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

BS12 Piezoresistive OEM Pressure Sensor

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Gas density monitor With integrated transmitter Model GDM-100-TI

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

XT100 SERIES: NTC, PTC, Pt100, TcJ, TcK, TcS, 4 20mA, 0 1V, 0 10V

Parametrable / Programmable Pressure Transmitter

Technical Data. Dimensions

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Relative and differential pressure transmitter type 692

BS12N Piezoresistive OEM Pressure Sensor

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Transmitter CS 21 Operation Manual

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

SDX Submersible Depth Transmitter User Manual

Project Title: Pneumatic Exercise Machine

Code Basic module and level control complete with optionals code

Technical Data Sheet MF010-O-LC

ATM.ECO/IS - Analog Transmitter with Temperature compensation

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

86BSD Backside Digital Output

AUTOMATIC GAS MANIFOLDS

Pressure Transmitters 36 F-27839

BUBBLER CONTROL SYSTEM

MIL-STD-883G METHOD

OC Panel High Limit Aquastat Kit, Manual Reset p/n

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

P499 Heavy Duty Pressure Transducer

Evaporative Emissions (EVAP) system, checking

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Technical Data. Dimensions

Programmable pressure and temperature transmitters PTM/RS485

Roller AC Servo System

Sensoric 4-20 ma Transmitter Board Operation Manual

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

SSL. Smart Valve Positioner.

FTC130 Transmitter. Operating Manual

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

JUMO dtrans p30 Pressure Transmitter

OEM Manual. MODEL ½ Digit DRUM SCALE

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

INSTALLATION GUIDE Gas Rangetops

High-performance submersible pressure transmitter For level measurement Model LH-10

Workhorse-15 Oxygen Generator

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Programmable pressure and temperature transmitters PTM/RS485

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

P-5215 Differential Pressure Transmitter

SENSORS Pressure CALDARO

Electronic relative and differential pressure switch type 616

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

Transcription:

SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP Control by pressure or temperature Pressure control 0-50 bar for all refrigerants Temperature control -20 to +100 C ADR 40 eng Regulator ADR Date::01/11 Page: 1

INDEX SPECIFICATION REGULATOR ADR 40 3 INTRODUCTION 3 SYSTEM COMPOSITION 3 REGULATION PARAMETERS 3 REGULATION 3 PROPORTIONAL BAND REGULATION (PROP) 4 WORKING IN TEMPERATURE 4 WORKING IN PRESSION 4 NORMAL WORKING SCHEME 5 HEAT PUMP WORKING 7 CONNECTIONS 9 The connectors 9 Connection scheme of ADR 40 10 Broken sensor connections 10 Dimension ADR 40 Board 11 Dimension ADR 40 DP IP 54 11 ADR 40 eng Regulator ADR Date::01/11 Page: 2

SPECIFICATION REGULATOR ADR 40 INTRODUCTION This regulator allows the control of fans, connected to single phase motors by 50/60 Hz, trough an algorithm which decides the fan speed on the base of a set of parameters adjusted by a trimmer on the border of the board and a pressure or temperature measure, executed in real-time by the board. The board schedules to work with temperature sensor NTC 10 kohm or with pressure sensor 4-20 ma. The temperature sensor will be connected to the connector CN3 which is related to the inscription NTC. The pressure sensor will be connected to the connector CN4 which is related to the inscriptions +12V, SIGN, GND. The fan will be connected to the connector CN1 on the level with the inscription VENT. The power supply 220Vac (50-60) Hz will be connected to the connector CN1 on the level with inscription N L SYSTEM COMPOSITION Input Temperature probe 10k @ 25 Pressure probe (4 20) ma Output Output for fan command 220 VAC 50/50Hz Output for fan command 220 VAC 50/50Hz REGULATION PARAMETERS REGULATION SET REGULATION - Through the trimmer on the board close to the inscription SET also during the regulator working. Indication and progress of the regulation Progress ideal point ( C) if the working is in temperature. Progress ideal point (bar) if the working is in pressure. - SET PROP ADR 40 eng Regulator ADR Date::01/11 Page: 3

PROPORTIONAL BAND REGULATION (PROP) PROPORTIONAL BAND REGULATION PROP - Through the trimmer on the board closet the inscription SET also when the regulator is working.. Indication and progress of the regulation Determining the extension of the proportional band, which is the regulation between and voltage. Determining a small/high band extension means a higher/smaller (faste/slower) variation of the ventilation speed for the same input signal - SET PROP WORKING IN TEMPERATURE The choice of the working in TEMPERATURE expects the use of a temperature sensor, type NTC10K. To connector CN1, signed with the inscription VENT, connect a single phase motor 230 VAC 50/60Hz To connector CN1, signed with the inscription N L, connect the power supply 230 Vac. The connector CN4 for the input in current, signed with the inscriptions (+12V, SIGN, GND), is not connected. For working in temperature it is necessary to connect the NTC probe and CN3 rim board which is related to the inscription NTC; By adjusting the trimmer of SET and of the PROP is possible to modify the working characteristics See in fig 1,2,3 some examples. The board calculates the fan speed, in relation to the temperature and based of the working characteristic determined by the values of the SET and PROP trimmer. WORKING IN PRESSION The choice of the working in PRESSION is dedicated to the control of the refrigeration pressure circuits for condensation and evaporation. The choice of the working in PRESSION expects the use of pressure transducers type 4-20 ma To connector CN1, signed with the inscription VENT, connect single phase motor 230VAC 50/60Hz. To connector CN1, signed with the inscription N L, connect the power supply 220VAC. For the working in pressure is necessary to connect the pressure sensor to the connector CN4 on the board signed with the inscription ( +12V, SIGN, GND) By adjusting the trimmer SET and PROP it is possible to modify the characteristics of working characteristics. See in fig 1,2,3 some examples. ADR 40 eng Regulator ADR Date::01/11 Page: 4

The board calculates the fan speed, in relation to the pressure and based of the working characteristic determined by the values of the SET and PROP trimmer. The working in pressure can also be affected by the temperature. Simply connect also the NTC sensor to connector CN1 signed wit NTC. The intervention of the NTC sensor determines to switch off the fan after 20sec when the temperature noticed by the sensor exceeds 90 C. The fan is switched on again to pressure controlled working only when the temperature gets down below 90 C. NORMAL WORKING SCHEME This regulator allows the control of a fan, through an algorithm which decides the fan speed on the base of temperature or pressure compiled through the temperature or pressure sensor connected to the board. The fan speed is controlled by the use of a temperature sensor NTC which senses the temperature and operates the fan like described in the graphics below. Operation is very much related and influenced by the values of SET and PROP trimmer and result in a lot of working settings; some examples are noticed below. The schematic diagrams below shows of change and influence in the different settings by the trimmer SET and Prop. The abscissa is drawn for the temperature or the pressure and in ordinate there s the voltage percentage provided to the fan. The graphic can be separated in 3 sectors. Sector (A): Temperature / pressure under C/bar min => Voltage to the fan is Zero Sector (B): Temperature / pressure between C/bar min and C/bar max => Voltage increases linearly between the minimum () and the maximum () Sector(C): Temperature/ pressure greater than C/bar max => Maximimum voltage () is supplied to the fan. NB.: The range of sector (B) to sector (C) includes a hysteresis avoiding, annoying hunting s between the working speeds. The same will be also for the range between sector (A) and sector (B). NB: Each fan start is begins with a short starting phase in which the speed is set to 70% of the total speed. After this short period it runs down to the equivalent speed according to the temperature or pressure signal. ADR 40 eng Regulator ADR Date::01/11 Page: 5

% +/2 0 (A) (B) C/bar min SET C/bar max (C) C/bar Fig. 1 % +/2 (A) C/bar min 0 (B) SET C/bar max (C) C/bar Fig.2 ADR 40 eng Regulator ADR Date::01/11 Page: 6

(+)/2 (A) (B) (C) Cbar min SET Cbar max Fig 3 HEAT PUMP WORKING It s possible to set the ADR 40 also to work in heat pump function. In that case the board works only with the pressure sensor 4-20 ma. This function can be used also in evaporating. To select this function it s sufficient to short-circuit the entry (connector CN3) NTC. In this case the normal function will be reversed as you will see in the following examples: The fan speed is controlled by a pressure sensor which senses the pressure and operates on the fan like described in the graphics below. Operation is very much related and influenced by the values of SET and PROP trimmer and result in a lot of working settings; some examples are noticed below. The schematic diagrams below shows of change and influence in the different settings by the trimmer SET and Prop. The abscissa is drawn for the temperature or the pressure and in ordinate there s the voltage percentage provided to the fan. The graphic can be separated in 3 sectors. Sector (A): Pressure under bar min => Maximum voltage () provided to the fan Sector(B): Pressure between bar min and bar max => Voltage that increases linearly between the minimum () and the maximum () Sector (C): Pressure greater of C/bar max => Voltage to the fan is ZERO ADR 40 eng Regulator ADR Date::01/11 Page: 7

NB.: The range of sector (B) to sector (C) includes a hysteresis avoiding, annoying hunting s between the working speeds. The same occurs also for the range between sector (A) and sector (B). NB: Each fan start is begins with a short starting phase in which the speed is set to 70% of the total speed. After this short period it runs down to the equivalent speed according to the temperature or pressure signal. (+)/2 (A) (B) (C) Fig 1 bar min SET bar max bar (+)/2 (A) (B) (C) bar min SET bar max Fig 2 ADR 40 eng Regulator ADR Date::01/11 Page: 8

(+)/2 (A) (B) (C) Fig 3 CONNECTIONS The connectors bar min SET bar max Con. CN1 No. pin Label Description Signal type 1 N Power supply input (NEUTRAL) 230 VAC (80 260 V) 50/60 Hz 2 L Power supply input (PHASE) 230 VAC (80 260 V) 50/60 Hz 3 FAN FAN output 230 VAC, max. 4 amps 4 FAN FAN output 230VAC max. 4 amps Con. CN4 No. pin Label Description Signal type 1 +12V Sensor Input 12V 2 SIGN Sensor output signal ma 3 GND Negative GND Con. CN3 No. pin Label Description Signal type 1 NTC NTC temperature sensor Input mv/ma 2 NTC NTC temperature sensor Input mv/ma ADR 40 eng Regulator ADR Date::01/11 Page: 9

Con. CN2 No. pin Label Description Signal type 1 PE System input (EARTHED) 2 PE System input (EARTHED) 230 VAC (180-260V) 50/60 Hz 230 VAC (180-260V) 50/60 Hz Connection scheme of ADR 40 Wiring for Heat pump function Pressure transducer 4-20 ma The scheme above shows the connection of a pressure transducer and alternatively the connection with a NTC sensor. By using a 3-wire pressure transducer the transducer has to be wired to GND, too Broken sensor connections In case of an interruption of a pressure transducer or temperature sensor the ADR 40 manages to run the connected fans even at about 70% of max speed. (Safe to fail) ADR 40 eng Regulator ADR Date::01/11 Page: 10

Dimension ADR 40 Board Dimension ADR 40 DP IP 54 COVER Pg 9 Pg 9 Pg 7 ADR 40 eng Regulator ADR Date::01/11 Page: 11