Section: R100 Bulletin: R100.50A Date: 12/07 Supersedes: 08/06 THE STANDARD

Similar documents
Per Section I of the ASME

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

Instructions for Installing and Operating Clark Reliance EA101 Series Levalarm

Prismatic and Flat Glass Water Gage Maintenance Instructions

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

MSC Guidelines for Refrigeration Machinery

High-Pressure Boiler Inspection Procedures: A Complete Checklist

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

627 Series Pressure Reducing Regulators

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

YARWAY WATER COLUMN INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

SCA Series Inverted Bucket Steam Traps

NAVSEA STANDARD ITEM. 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

VB-7263 Series. Application. Features. Applicable Literature

THE PROCESS OF JOINT INTEGRITY

GAS SUPPLY DESIGN GUIDE

GM Series Dual-Block Multi-Function Gas Control Valves

Continental Industries STEEL SERVICE TEES or FAX Visit

Series 8500 Expansion Compensators. Catalog 674H

Mark 958 Series Sanitary Gas Back Pressure Regulators

FIRE PROTECTION PRODUCTS

INSTALLATION & MAINTENANCE INSTRUCTION

Type 92S Pilot-Operated Steam Regulator

SECTION BUTTERFLY VALVES

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

VBS-9263 Series. Application. Features. Applicable Literature

Horizontal Bladder Tanks

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Standard Specifications

Vertical Bladder Tanks

TECHNICAL DATA. Q = C v P S

MSC Guidelines for Independent Fuel Tanks

TECHNICAL DATA OBSOLETE

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

TECHNICAL DATA. Q = C v P S

Types S100K and S102K Pressure Regulators

VERTICAL BLADDER TANK

TechTalk. Purging for Delayed Coking. Understanding purging system design in heavy-fouling applications. Outline

Bermad Pressure Reducing. Model: 42T

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

HORIZONTAL BLADDER TANK

Model MTB-ASME Vertical Bladder Tanks

VB-7273 Series. Application. Features. Applicable Literature

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Model MTB-ASME Horizontal Bladder Tanks

TEST SPECIFICATION NYT-909-C

SECTION I REGULATORS

BVA BUTTERFLY VALVES

Model MTB-ASME Vertical Bladder Tanks

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

Float Operated Level Controllers

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

TECHNICAL DATA. Q = C v P S

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

RELIEF VALVES. General Description

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

SECTION DIGESTER GAS SAFETY AND CONTROL EQUIPMENT

Mark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators

Types 95L and 95H Pressure Regulators

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

Technical Data Sheet T 2025

TECHNICAL DATA. Q = C v P S

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

v. Size shall be specified on drawings.

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Dual position solenoid valve Type ICSH 25-80

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Installation, Operation and Maintenance Manual for Back Pressure Regulator

CASH VALVE TYPE KP BACK PRESSURE VALVES

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

1.0 - OPENING AND CLOSING THE DOOR

Magnetic Level Gauges

Atmospheric relief valve type 1100 Installation and maintenance instructions

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Fisher DVI Desuperheater Venturi Inline

FILTER TYPE PRESSURE SNUBBER

Transcription:

Section: R100 Bulletin: R100.50A Date: 12/07 Supersedes: 08/06 THE STANDARD APPROVED APPROVED

THE ELECTROLEV (PROBE) COLUMN CONNECTIONS Connections may be flanged, socket welded, butt welded or screw type. WIRING LEADS High temperature, Teflon insulated leads extend 30 inches beyond the chamber to facilitate installation. Optional longer leads available. 1" PIPE PROJECTION INSTALL SHUTOFF VALVES BETWEEN DRUM AND ELECTROLEV 9 8 NORMAL WATER LEVEL PROBE NUMBER LOW WATER LEVEL 7 6 5 4 3 2 1 Steam &Wate r Center s Overall 31.6 70.3 TFE EL450 2

ELECTRO EYE-HYE STANDARD LOW VOLT CONTROL UNIT 3

INDICATORS 4

LevelMax SYSTEMS Clark-Reliance offers the ultimate choice in Boiler Drum Level instrumentation, with the LevelMax system. This combination Drum Level Instrument Assembly provides Local and Remote monitoring of the level in the boiler drum. This system utilizes the world renowned Electro Eye-Hye System (Remote Drum Level Indicator), with a water gage glass attached for local (direct) viewing of the drum level. The LevelMax system provides one of the most economical drum level systems for ASME code compliance, and compact assembly design for any application. This concept eliminates a portion of the field piping, welding, which is associated with the traditionally independent instruments. Thereby, reducing the installation cost. The Electro Eye-Hye System is the hub of the assembly, and is available with in the following design pressures: 450, 1000, 1800, & 3000 PSIG. The photograph illustrates an actual unit for High Pressure service (up to 3000 PSI), including our Simpliport Bicolor type water gage glass. Optional Low Pressure models are rated up to 1500 PSI with Lever actuated water Gage isolation valves and an end stem connected water gage for easy maintenance. The High Pressure design for application pressures up to 3000 PSI include chain wheel actuated water gage valves and flanged connections to the water gage. The following types of water gage glass are available for your application maximum design pressures: The Specification of these systems is quite easy. Begin by selecting the appropriate Electro Eye-Hye System (from this bulletin), to meet or exceed the design pressure of your application. Then, select the type of water gage glass to meet your specifications. Then, select one or two sets of water gage glass connections. Additional installation considerations include the orientation of connections on the Electro Eye-Hye column for the probes, the vessel connections, and the water gage glass connections. A complete set application drawings and instruction manuals will be furnished for your approval prior to manufacturing. CUSTOMER SPECIFICATION OPTIONS On LevelMax Assemblies, the Electrolev Column is serving as the water column to support one or two water gage glasses for a complete level indication assembly. The illustration below offers guidance for User selections to optimize the installation. The conductivity probes must be located on a different position than a water gage glass, in order to facilitate maintenance or for inspection purposes. STEAM AND WATER (VESSEL) CONNECTIONS LOCATION - A Specify the connection size from one of the following (NPS): 1, 1-1/4, or 1-1/2 (including the type and rating) C CONNECTIONS ELECTROLEV PROBE LOCATIONS specify location - B, C, or D 1) Specify the number of probes: 10, 12, 20, or other 2) Complete the form drawing for the probe spacing and dimensional information. 3) MINIMUM SPACING BETWEEN PROBES 1 (25 mm). MINIMUM SPACING FROM TOP PROBE TO STEAM CONNECTION = 1-1/2 (40 mm). MINIMUM SPACING FROM BOTTOM PROBE TO WATER CONNECTION = 1-1/2 (40 mm) 4) STANDARD DRAIN CONNECTION FOR LEVELMAX COLUMN ASSEMBLIES = 3/4 (20 mm) FEMALE SOCKET WELD. WATER GAGE VALVE CONNECTIONS WITH GAGE specify location - B, C, or D on the column will accommodate a wide variety of Clark-Reliance valve sets and water gage glasses. Section1 of the ASME Boiler Code permits 3/4 threaded connections for applications up to 1500PSIG. Refer to Bulletin AB5.1C for additional details on Bronze and Steel Water Gage valves. Standard models include: BG404 (Bronze construction, lever actuated, to 450 PSI) SG854 (Steel construction, lever actuated, to 1500 PSI) SG777* (Steel construction, Chain wheel actuated, to 2500 PSI) SG677* (Steel construction, Chain wheel actuated, to 3000 PSI) B CONNECTIONS A STEAM AND WATER D CONNECTIONS WATER GAGE GLASSES Select the type of water gage glass, from the following options: PRISMATIC to350 PSI (Refer to bulletin R100.31) FLAT GLASS to 2000 PSI (Refer to bulletin AB7.3A) SIMPLIPORT Bicolor P4000 Series to 1500 PSI (Refer to bulletin AB7.5) SIMPLIPORT Bicolor P4100 Series* to 3000 PSI (Refer to bulletin AB7.5) Specify the location from the centerline of the gage visibility to the water connection centerline on the vessel. Modern technology LED Lighting accessories for the water gage glass can be located on bulletins AB7.4 for Flat Glass Gages and AB7.5C for Simpliport gages. Consult with our Applications Engineering staff, with any questions concerning LevelMax systems. Local assistance is available, upon request. 5

THE PROBES: 6