ASHE Monograph. Medical Gas Cylinder and Bulk Tank Storage

Similar documents
Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

STORAGE OF COMPRESSED GAS CYLINDERS (SAF-SPI-15)

UTMB RESPIRATORY CARE SERVICES GUIDELINES Respiratory Care Services Medical Gas Cylinder Storage, Use and Transport

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

SERIES & NO. SMI - 115

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Number: 2015 IFC Effective Date: February 1, 2017 Page 1 of 5

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

DSEAR- Storage, Use and handling of gas cylinders guidance.

Compressed Gases Safety Program

Developing a Policy for Auto Transportation of Medical Oxygen in High Pressure Cylinders and Cryogenic Vessels

Savard Labor & Marine Staffing, Inc. Compressed Gas Safety Program Rev3/14

LLSC Jan 2019 WHEA. Jan 2019 Lunch & Learn OXYGEN CYLINDER USE & STORAGE. Presented by Lauzon Life Safety Consulting 1

Laboratory Safety Inspection Checklist

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Date Issued: 27 September 2018

Compressed Gases and Cryogens


Cylinder Exchange Training Manual

Fire Performance Safety Standard

MEDICAL EQUIPMENT CATALOG

MATERIAL SAFETY DATA SHEET. Oxygen, Refrigerated Liquid DOT Hazard Class: 2.2

Gas Cylinder Storage Structures

UNIVERSITY OF TOLEDO

KENNECOTT UTAH COPPER CORPORATION SAFETY AND HEALTH STANDARDS COMPRESSED GAS

General Precautions for handling compressed gases

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

User manual. ZX trolley.

Material Handling and Storage of compressed gases and Air equipment

Oxygen and other Compressed Medical Gas Rules and Regulations Complying with the Law. Regulatory agencies:

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Hazard Identification and Risk Assessment Form. Risk Assessment

BCGA GUIDANCE NOTE 17

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Pure Gases Liquid & High Pressure High Pressure Gas Mixtures Equipment Safety MEDICAL GASES

Welcome to the Specialized Medical Services Respiratory training webinar series!

Laboratory Safety Committee

Compressed Gas Cylinders - Guideline

OVERVIEW OF PROPANE DISTRIBUTION SYSTEMS FOR HVAC AND PLUMBING PROFESSIONALS SAMPLE COURSE

FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM

COMPRESSED GASES CHAPTER 53

Aerosol Portion: faster than butyl acetate;immediate at temperatures above -35 C. Liquid Portion: slower than butyl acetate.

SAFETY DIRECTIVE 3.0 REFERENCES. 3.1 See Appendix B

General Safety and Health Provisions for Construction Self Inspection Checklist

SAFETY DATA SHEET According to Regulation (EC) N 1907/2006

SAFETY DATA SHEET (SDS)

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

CUSTODIAL Safety Inspection Checklist

Class 2 Gases Learning Tool

Having reviewed the Law on Constructional Organisation of Buildings promulgated by Legislative Decree No.(13) of 1977, as amended,

Quebec Quebec Tel : Fax : MSDS: Hydrogen 25% in Nitrogen Mixture PRODUCT INFORMATION

LABELLING OF MEDICAL GAS CONTAINERS

DATA SHEET Revised edition no : 0. o óm MÁM M« : Industrial and professional. Perform risk assessment prior to use. Company identification

NPGA White Paper. OSHA Hazard Communication Standard

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Laboratory Inspection Checklist

5.0 Store. safely IN THIS SECTION: 5.1 Decanting or transferring

Quebec Quebec Tel : Fax : MSDS: cis-2-butene PRODUCT INFORMATION

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Biosafety Level 2 (BSL2) Laboratory Safety Inspection Checklist

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

SAFETY DATA SHEET (SDS)

Safe Handling of Pressurized Gases and Cylinders. Dr. Michael Hanisch

Risk Management Department. Compressed Gas Safety

Standard Operating Procedure (SOP) Compressed Gas Cylinders (Original SOP from Eastern Washington University)

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

WLPGA East African Summit

MATERIAL SAFETY DATA SHEET. ACTION LANOSPRAY Commercial Grade Lanolin Protection

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Safety data sheet GRADE F 160 SAMPLE Revision date : 2009/08/07 Page: 1/6

Safety Data Sheet. Zero Air 1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer NorLab a division of Norco 898 W. Gowen Rd.

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

Bauman Machine Inc. COMPRESSED GAS CYLINDER SAFETY

SAFETY DATA SHEET (SDS)

Refrigerant R170 - ETHANE

API RECOMMENDED PRACTICE 500 THIRD EDITION, DECEMBER 2012 ERRATA, JANUARY 2014

Paint Spraying and Other Painting Processes Fire Safety

MATERIAL SAFETY DATA SHEET Product Name: Gas Mixture (1ppm - 50% Carbon dioxide + Balance Nitrogen) DOT Hazard Class: Emergency No: UN 1956

Safe Handling - Dimethylamine

Quebec Quebec Tel : Fax : MSDS: Methane Compressed PRODUCT INFORMATION

Safety Manual HAL Extraction Technology Ltd. Extraction Booth Systems

Safety data sheet Code MAP-Pro Page 1 of 5 Issue Date Feb 26, SECTION 1: Identification of substance/preparation and company

Material Safety Data Sheet

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

GUIDELINES ON SAFE HANDLING AND STORAGE OF COMPRESSED GASES CHEMICAL MANAGEMENT CENTRE

Compressed Gasses Safety

Sodium Lauroyl Sarcosinate

Drum / cylinder handling

MSDS Interspiro Spiroscape EEBD (compressed breathing air)

SAFETY DATA SHEET ACETYLENE (DISSOLVED)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Wilkins Safety Group

Transcription:

ASHE Monograph Medical Gas Cylinder and Bulk Tank Storage

ASHE Monograph Medical Gas Cylinder and Bulk Tank Storage Susan B. McLaughlin, MBA, FASHE, CHFM, CHSP David A. Dagenais, CHSP, CHFM, SASHE JUNE 2012

2012 ASHE The American Society for Healthcare Engineering of the American Hospital Association 155 North Wacker Drive, Suite 400 Chicago, IL 60606 312-422-3800 ashe@aha.org www.ashe.org ASHE members can download this monograph from the ASHE website under the Resources tab. Paper copies can be purchased from www.ashestore.com. ASHE catalog #: 055954 About the Authors Susan B. McLaughlin, MBA, FASHE, CHFM, CHSP, is managing director of MSL Healthcare Consulting, Inc., in Barrington, Ill. She is a nationally known speaker in the field of health care safety, regulatory compliance, and emergency management and has authored numerous articles and books on related topics. David A. Dagenais, CHSP, CHFM, SASHE, is director of plant operations and security at Wentworth-Douglass Hospital in Dover, N.H. He has been involved in code development for more than 15 years and is coauthor of the NFPA 99: Health Care Facilities Code Handbook. He has been a presenter at many national health care engineering conferences. Disclaimer: This document was prepared on a volunteer basis as a contribution to ASHE and is provided by ASHE as a service to its members. The information provided may not apply to a reader s specific situation and is not a substitute for application of the reader s own independent judgment or the advice of a competent professional. Neither ASHE nor any author makes any guaranty or warranty as to the accuracy or completeness of any information contained in this document. ASHE and the authors disclaim liability for personal injury, property damage, or other damages of any kind, whether special, indirect, consequential, or compensatory, that may result directly or indirectly from use of or reliance on this document.

Medical Gas Cylinder and Bulk Tank Storage This monograph summarizes storage requirements for medical gas cylinders, including bulk tank storage, in health care occupancies. Decision points for various storage requirements are based on the total volume of gas in stored cylinders. 1 Definitions 1.1 Cylinder capacity is approximately as follows: E cylinder: 23 cubic feet G cylinder: 254 cubic feet H cylinder: 337 cubic feet 1.2 Medical gas cylinders are considered to be in use if they are: Actually being used by a patient. Secured to equipment (e.g., a crash cart, wheelchair, single E cylinder two-wheel cart, or gurney) so as to be ready for immediate use. Placed in a patient room for immediate patient use. Note: Cylinders that are in use are excluded from the total volume of gas considered for storage determination. Regulatory Requirements As of June 2012, both the Joint Commission and the Centers for Medicare and Medicaid Services (CMS) require compliance with the 1999 edition of NFPA 99: Standard for Health Care Facilities because this is the edition cited by NFPA 101-2000: Life Safety Code, which is the edition of that code CMS requires hospitals to follow. It is anticipated that both organizations will adopt the 2012 edition of NFPA 99, now titled Health Care Facilities Code. Therefore, this monograph references NFPA 99-2012 for medical gas cylinder storage requirements. Relevant information can be found in NFPA 99-2012 as follows: Storage of 300 cubic feet or less of gas: 11.3.3 11.3.3.2 Storage of between 300 and 3,000 cubic feet of gas: 11.3.2 11.3.2.3 Storage of more than 3,000 cubic feet of gas: 11.3.1, 5.1.3.3.2 5.1.3.3.3 Storage of cylinders and containers: 11.6.5 Mechanical ventilation: 9.3.7 Transfilling cylinders: 11.5.2.2 11.5.2.3 The full text of NFPA 99-2012 should be consulted for complete details. 1

2 ASHE Monograph 2 General Storage Requirements for All Medical Gas Cylinders 2.1 All medical gas cylinders (including E cylinders) must be physically supported, either in a stand or rack or chained or strapped to the wall. This requirement is intended to prevent mechanical hazards caused by a sudden release of gas if a tank falls over. 2.2 Oxidizing gases such as oxygen, nitrous oxide, and nitrogen must not be stored with flammable gases. 2.3 Medical gas cylinders should not be stored near radiators, steam pipes, heat ducts, or other sources of heat. 2.4 Full cylinders must be segregated from empty cylinders. The Joint Commission defines segregation as storage in separate racks. Empty cylinders must be marked to avoid confusion, which is typically done by labeling the racks Empty and Full. 3 Requirements for Cylinder Storage of Less Than 300 Cubic Feet of Gas 3.1 Cylinders with contents totaling less than 300 cubic feet of gas per smoke compartment (22,500 sq. ft. maximum) are not required to be stored in enclosures of any type. 3.2 Both the Joint Commission and CMS permit storage of up to 300 cubic feet of gas (12 E cylinders) per smoke compartment without any specific protection or room requirements. Tanks may be kept in an area open to the corridor, but may not obstruct the corridor. The number of 12 E cylinders allowed to be stored is based on full tanks; empty tanks (as well as tanks that are in use) do not count toward the total. 3.3 All full cylinders totaling up to 300 cubic feet may be stored in one rack. It is not necessary that they be distributed throughout the smoke compartment. 3.4 Wooden racks are permitted for storage of up to 300 cubic feet of gas. 3.5 If stored inside a room, the local authority having jurisdiction (AHJ) may enforce the requirements of 4.1 and 4.2, below.

Medical Gas Cylinder and Bulk Tank Storage 3 4 Requirements for Cylinder Storage of 300 3,000 Cubic Feet of Gas 4.1 Cylinder storage must be located either outdoors in a lockable enclosure or indoors in a lockable enclosed space constructed of non-combustible or limited-combustible materials. 4.2 In such a room, oxidizing gases must be separated from combustible materials in one of the following ways: It is possible to store up to 130 E cylinders in an approved storage room. Consult local authorities having jurisdiction, however, as additional approvals may be required. Locate gases at least 20 feet from combustible materials in non-sprinklered areas Locate gases at least 5 feet from combustible materials in a room that is fully sprinklered Contain gases in a flammable cabinet with a fire resistance rating of at least 30 minutes. 4.3 Cylinders stored outside must be protected as follows: From the ground beneath to prevent rusting From accumulation of snow and ice during the winter From exposure to direct sunlight during the summer 5 Requirements for Cylinder Storage of More Than 3,000 Cubic Feet of Gas 5.1 All Locations 5.1.1 The storage requirements for cylinders totaling more than 3,000 cubic feet apply to single-tank storage as well as rooms containing gas manifolds and associated piping. 5.1.2 The storage location must be lockable. 5.1.3 Chains, racks, and stands for medical gas cylinders must be constructed of non-combustible or limited-combustible materials. 5.2 Indoor Locations 5.2.1 Indoor locations for cylinder storage must have walls, floors, ceilings, and doors constructed with at least a one-hour fire resistance rating.

4 ASHE Monograph 5.2.2 Full or empty cylinders may be stored in the same location as their respective central supply system. They may NOT be stored in enclosures that contain medical air compressor sources, medical vacuum supply systems, or waste anesthetic gas disposal (WAGD) systems. 5.2.3 Electrical requirements Any electrical devices such as switches or outlets in rooms where medical gas is stored must be located at least 5 feet off the finished floor. An alternative is to have the light switch outside the room and no electrical outlets inside. All electrical service must be compliant with NFPA 70: National Electrical Code for ordinary locations. Electrical power must be part of the essential electrical system. In locations where only oxygen and/or nitrogen is stored, the wiring and electrical equipment is not required to be explosion-proof. 5.2.4 Heating of the enclosure, if necessary, must be via indirect means. In other words, the source of the heat must be outside the enclosure, with only warm air, steam, hot water, etc. passing into the enclosure. 5.2.5 Ventilation requirements 5.3 Outdoor Locations The area must be equipped with dedicated mechanical ventilation that draws air from within one foot of the floor and operates continuously. A source of makeup air must be provided. This ventilation system must not be connected with other facility ventilation systems. The power supply for the ventilation system must be part of the essential electrical system. 5.3.1 Outdoor locations for cylinder storage must be enclosed with a wall or fencing made of non-combustible materials. 5.3.2 Outdoor storage locations that are surrounded by solid walls must have protected ventilation openings at the base of each

Medical Gas Cylinder and Bulk Tank Storage 5 wall, unless that wall is shared with another enclosure or building. 5.3.3 Cylinders stored outside must be protected as follows: From the ground beneath to prevent rusting From accumulation of snow and ice during the winter From exposure to direct sunlight during the summer 6 Signage Requirements for Cylinder Storage Signs must be posted on each door or gate of a gas cylinder storage room or enclosure. The signs must be readable from a distance of 5 feet and must include the following language: CAUTION OXIDIZING GAS(ES) STORED WITHIN NO SMOKING 7 Requirements for Transfilling Liquid Oxygen 7.1 Transfer of any gases from one cylinder to another in patient care areas of health care facilities is prohibited. 7.2 Transfilling of liquid oxygen must be performed in an area that is: Mechanically ventilated Sprinklered Ceramic- or concrete-floored Separated with at least one-hour construction from any patient care area 8 Requirements for Outdoor Bulk Tank Storage 8.1 Bulk storage tanks and associated systems are considered critical components of the piped medical gas system.

6 ASHE Monograph 8.2 Tanks must be installed as follows: Above ground and not on roofs Away from electrical services or power lines 10 feet clear of vehicles and sidewalks At least 50 feet from wood-framed buildings 8.3 Tanks must have permanent signage that states: OXYGEN NO SMOKING NO OPEN FLAMES 8.4 Access to tanks should be controlled or locked.

www.ashe.org