SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Similar documents
SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

Town of Poughkeepsie Received: Permit # Aboveground/Inground Pool Building Permit Application

Pool Submittal & Inspection Packet

Swimming Pool Barrier 2015 International Swimming Pool and Spa Code

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

AMITY TWP POOL REQUIREMENTS

CITY OF HERCULANEUM RESIDENTIAL SWIMMING POOL HANDOUT

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Building Code Guidelines For Home Pools

Requirements for Swimming Pools

INGROUND OR ABOVE GROUND POOL. APPROVALS REQUIRED (Check here if): Well Septic

Swimming Pool Permit and Inspection Requirements

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Check with local zoning official for property line distance requirements.

CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA (949)

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

Pool Barrier, Fence, Gate, Closer and Alarm Requirements

Information Required on Building Permit Applications and Building Plans for the Installation of Swimming Pools, Spas, and Hot Tubs

Building Code Guidelines For Home Pools

Whitehall Township Swimming Pool, Spa and Hot Tub Code Guide

Building Code Guidelines for Residential Pools

Swimming Pools, Hot Tubs and Spas

Swimming Pool Fence Guide Kodiak Iron

BULLETIN SP b. All doors providing direct access from the home to the pool must be equipped with a self

Permit and Inspection Requirements for Swimming Pools

Residential Swimming pools

Information on RESIDENTIAL SWIMMING POOLS

RESIDENTIAL SWIMMING POOLS

Pool / Hot Tub Permit

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

Residential Swimming Pool/Spa Requirements

Swimming Pool Permits are About Health and Safety

Homeowner s Safety Guidelines for Home Pools

RESIDENTIAL SWIMMING POOL

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team

City of Lockport Above Ground Pool Regulations

Swimming Pool Requirements Packet

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

INGROUND OR ABOVE GROUND POOL. APPROVALS REQUIRED (Check here if): Well Septic

TOWN OF FARMINGTON DEPARTMENT OF PUBLIC WORKS & DEVELOPMENT SERVICES. Russell M. Arnold Jr., P.E. Director/Town Engineer (860)

Swimming Pool Installation

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team

Subdivision: Block: Lot: Part 3. Contractor Address City/State/Zip Phone Pool:

Norton Shores Building Division 4814 Henry Street, Norton Shores, Michigan Telephone: (231) Pool Requirements

Swimming Pool Requirements

Home Inspector Newsletter Hamilton, Ancaster, Binbrook, Brantford, Burlington, Caledonia, Dundas, Dunnville, Flamborough and area

SWIMMING POOL/SPA & SAFETY BARRIER PERMIT APPLICATION

TOWN/VILLAGE OF LIMA POOL PERMIT APPLICATION

Building Standards Department Pool Requirements 111 N. Michigan AV, Bradley, IL Phone Fax PRIVATE SWIMMING POOLS

Building Department Informational Handout

SWIMMING POOL / SPA PLAN REVIEW CHECKLIST

COURSE SYLLABUS. Program for Resource Efficient Communities University of Florida PO BOX Gainesville, FL

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2015 International Swimming Pool and Spa Code

Residential Above-Ground and In-Ground Swimming Pool, Hot Tub and Spa Construction June 2017

Building Services Department

SWIMMING POOLS, SPAS & HOT TUBS. This hand out is for REFERENCE ONLY. For more details see specific code sections.

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2014 Florida Building Code and 2014 Florida Building Code Residential

RESIDENTIAL POOL, SPA AND HOT TUB PERMIT REQUIREMENTS

Fencing your spa or swimming pool

Fencing your spa or swimming pool

SWIMMING POOL REQUIREMENTS

Swimming Pool Construction Guidelines

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST

Eaton County Department of Construction Codes. Requirements for, Swimming Pools, Hot Tubs and Spas in Michigan

Swimming Pool Requirements

Ordinance amendments are included below. New language is underlined in red. Deleted language is lined-through.

4700 Drexel Drive, Highland Park, TX office fax Department of Building Inspection

2015 ISPSC International Swimming Pool and Spa Code Information & Requirements

SWIMMING POOL AND SPA REQUIREMENTS (Including Fire Pit, BBQs, and Accessory Structures)

Swimming Pools, Spas & Hot Tubs Construction requirements for outdoor private swimming pools (in-ground and above-ground), spas and hot tubs

*A Certificate of Survey for the property may be on file at City Hall if the house was built after 1984.

City of Crystal Lake Community Development Department

CURRENT REQUIREMENTS FOR SWIMMING POOLS CONTAINED IN THE STATE FIRE PREVENTION AND BUILDING CODE (THE "UNIFORM CODE") (June 2008) Introduction

(145) GENERIC TYPE-A INFLATABLE MANUAL ENGLISH X /09/2015

SWIMMING POOL BUILDING PERMIT REQUIREMENTS FOR THE UNINCORPORATED TERRITORY OF DOUGLAS COUNTY, KANSAS

Nottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)

If the answer to ALL the following points (G to M) is 'Yes', the pool is not required to be surrounded by a pool fence:

TOWN OF AMHERST BUILDING DEPARTMENT

GAINES CHARTER TOWNSHIP INSPECTION DEPARTMENT Phone: Fax: SWIMMING POOL PERMIT APPLICATION

Acknowledgement must be given for the assistance provided by Barry Hutchens, Kenji Iwanaga, and AJ Murguia in preparing this booklet.

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

VILLAGE OF ISLAND PARK LOCAL LAW NO. 12 OF THE YEAR A local law Private Swimming Pools

Fence and Swimming Pool Permit Guidelines

Village of Lombard. Building Division/Community Development Department 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Handouts Included: Minimum Barrier Requirements For Pools / Spas & Hot Tubs

ANDOVER CITY COUNCIL Tuesday, October 08, 2013 Minutes

TOWN OF AURORA. Pool Enclosure Permit Guide. PLANNING AND BUILDING SERVICES Building Division

BY-LAW NUMBER 816. WHEREAS Notice of Motion of the present By-law was given at the Council Meeting held on July 6 th, 2015;

Department of Public Services Building Engineering Planning Water & Sewer POOL, HOT TUB & FENCE REQUIREMENT CHECKLIST

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

NO wiring shall be above the pool within 10, measured horizontally, or under a pool within 5, measured horizontally.

SWIMMING POOLS CHAPTER 41

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

Private Swimming Pool Permit Application

Transcription:

SWIMMING POOL, SPA, & HOT TUB GUIDELINES A. Adopted construction codes and installation requirements 1. 2015 edition of the International Residential Code and Appendix Q, 2. 2014 edition of the National Electrical Code B. Permit Procedures The Swimming Pool Contractor must apply for the Construction Permit by providing the following: Submit two (2) pool design plans; with each plan stamp approved by the electric underground utility company. Each plan must also include the installation design, depth of pool and location of equipment, per the above mentioned adopted codes. Submit two (2) site plans (a survey plat is required) showing the location of the pool with respect to the property lines, easements and house. Vent on pool heater shall terminate not less than 4 ft. below or 4 ft. horizontally from, nor less than 1 ft. above any door, operable window, or gravity air inlet into any building or less than 4 ft. from any property line except a public way. No part of pool, equipment or decks will be allowed in easements. NOTE: Pool setbacks side to PL = 3, rear to PL = 3, pool to house (one/one ratio = pool excavation depth at the point closest to house = pool setback distance.) All pool must be a minimum of 10 off any retaining wall over 3 tall, or an engineered letter must be provided. Permit application must be filled out completely to include the following: 1. All applicable contractor information. 2. Subcontractors listed on permit must be licensed and currently registered with the City of Rockwall. 3. A fence permit must also be obtained if a new or reconstructed fence is to be installed. C. Inspection Procedure The following inspections can be requested online at http://www.rockwall.com/buildinginspections/inspectionreq.asp or by calling our inspection line at 972-771-7760. Any inspection request received after 7:30 AM will be scheduled for the next business day.

Information listed below must be provided when making an inspection request: Permit number (located in top right hand corner of permit application) Address Contractor name Type of inspection Construction Site Requirements Erosion protection required. A four-foot (4 ) temporary fence must be in place at all times during construction until the permanent fence is installed. Streets and alleys must be kept free of mud and debris at all times. Pool Layout Inspection Proper placement of the pool for setback requirements. Encroachment on easements. Inspection of permanent barriers (fences) around pools for compliance with the code. Safety alarm or self-closing devices on residence door will be inspected. (Refer to the 2015 International Residential Code, Appendix Q. Barrier Requirements, Sec. AQ 105.2 copy attached). The resident must sign a certification document provided by the city, which states that this requirement has been met. This letter must be left with the blue permit card on the job site at the time of inspection. (Door alarm letter must be signed by the homeowner in front of a notary). Windows must be of tempered glass if bottom edge of glass is less than 60 inches above walking surface and within 60 inches horizontally of the water s edge. No excavation work should be performed until all of the items listed above are completed and passed by the City. Belly Steel Inspection Be sure setbacks are per the approved site plan before any excavation. Steel reinforcement inspection. Bonding shall be done on the belly steel inspection with a No. 8 or larger solid copper conductor around pool belly and looped a minimum of 4 times up to pool deck steel and fixtures. All 120 volt light fixtures shall be bonded with a No. 8 solid copper wire attached to the fixture housing lug. This wire should then be run parallel with the brass pipe and bonded to the pipe with a suitable clamp. Connection shall be made by exothermic welding or by pressure connectors or clamps

that are labeled as being suitable for the purpose and are of the following materials: Stainless steel, brass, copper. Suction outlets shall be designed and installed in accordance with ANSI/APSP-7 P-Trap Waste water is to be disposed of through a public sewer; a minimum of three (3) inch P-trap shall be required. The tailpiece from the trap shall extend a minimum of three (3) inches above finished grade and below finished floor grade of structure. Traps need not be vented when located on the exterior of the building. The connection between the filter waste discharge piping and the P-trap shall be made be means of an air gap. Deck Steel Inspection Deck steel must be in place (min. #3 rebar on 18 centers) and properly supported with expansion material installed. Any decks placed on top of loose fill dirt will have footing dug around to prevent dirt from eroding from underneath. Common bonding grid as well as the brass pipe clamp must be visible! Any metallic material (handrails, slides, diving boards, etc.) must be grounded to the bonding grid with a #8 solid copper wire. A static water or air pressure test of not less than twenty -five (25) psi will be required on the deck steel inspection. Piping can be in a manifold and tested separate from equipment. Final Inspection Grass, vegetation or approved means of erosion control must be in place at property lines and City property at alleys and parkways. All pool finals must be called in prior to plastering, all equipment shall be wired and ready for operation. Fence must be in place and meet all the requirements of attached appendix. If you have any further questions, please call 972-771-7709.

2015 International Residential Code Appendix Q Section AQ 105.2 Barrier Requirement 1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the barrier, which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier, which faces away from the swimming pool. Where the top of the pool structure is above grade, such as an aboveground pool, the barrier may be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). 2. Openings in the barrier shall not allow passage of a 4-inch-diameter (102 mm) sphere. 3. Solid barriers, which do not have openings, such as masonry or stonewall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. 4. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed 1.75 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1.75 inches (44 mm) in width. Exception: Boards with a minimum 60-degree angle, cut and placed at the top of the horizontal fence members, may be used on existing fences that will become pool barriers. This exception does not apply to fences adjacent to public right of way. 5. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1.75 inches (44 mm) in width.

6. Maximum mesh size for chain link fences shall be a 2.25-inch (57 mm) square unless the fence is provided with slats fastened at the top or the bottom, which reduce the openings to not more than 1.75 inches (44 mm). 7. Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall not be more than 1.75 inches (44 mm). 8. Access gates shall comply with the requirements of RAQ105.2, Items 1 through 7, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism and openings shall comply with the following: 8.1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate, and 8.2. The gate and barrier shall have no opening greater than 0.5 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. 9. Where a wall of a dwelling serves as part of the barrier one of the following conditions shall be met: 9.1. The pool shall be equipped with a powered safety cover in compliance with ASTM F1346; or 9.2. All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and/or its screen, if present, are opened. The alarm shall be listed in accordance with UL 2017.The audible alarm shall activate within 7 seconds and sound continuously for a minimum of 30 seconds after the door and/or its screen, if present, are opened and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm system shall be equipped with a manual means, such as touch pad or switch, to temporarily deactivate the alarm for a single opening. Deactivation shall last for not more that 15 seconds. The deactivation switch(es) shall be located at least 54 inches (1372 mm) above the threshold of the door; or 9.3. Other means of protection, such as self-closing doors with self-latching devices, which are approved by the governing body, shall be

acceptable so long as the degree of protection afforded is not less than the protection afforded by Item 9.1 or 9.2 described above. 10. Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure and the means of access is a ladder or steps, then: 10.1. The ladder or steps shall be capable of being secured, locked or removed to prevent access, or 10.2. The ladder or steps shall be surrounded by a barrier, which meets the requirements of RAQ105.2, Items 1 through 9. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a 4-inch-diameter (102 mm) sphere. Fence barrier exceptions for spas or hot tubs: Safety covers for spas and hot tubs must comply with ASTM F 1346-91. 1. There should be a means of fastening the safety cover to the hot tub or spa, such as key locks, combination locks, special tool, or similar devices. 2. The safety cover should have a label that provides a warning and message regarding the risk of drowning. 3. The cover should have been tested to demonstrate that it is capable of supporting the weight of one child (50 pounds) and one adult (225 pounds). 4. There shall be no openings in the cover itself or at any point where the cover joins the surface of the hot tub or spa that would not allow a 4-inch sphere to pass through. 5. Safety covers are to be installed in accordance with the manufacture s instructions.