User Manual. Portable Balances PL-E

Similar documents
User Manual. Precision and Analytical Balances ME-T

English. Quick Guide MS-TS Precision and Analytical Balances

Operation Instruction. BSM Series Electronic Precision Balances

User Manual. Robotic Mass Comparator e100

User Manual. Quantos Automated Dosing Liquid Module

STANDARD OPERATING PROCEDURE

User Manual. Robotic Mass Comparator e5

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

User Manual. Pipette Calibration Balance XPE26PC XPE26PC METTLER TOLEDO

User Manual. Quantos Automated Dosing Liquid Module

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

KERN EG/EW Version /02

KERN CM Version /2004

American Weigh Scales, Inc. LB User Manual

User Manual. Quantos Automated Dosing Powder Module

Operating Manual Body fat balance

Sartorius Basic plus Service Manual. WBP5007-e95021

Eclipse Precision & Analytical Balances

MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

YAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO USA Tel (719) Fax (719)

Service Manual. Sartorius Expert. LE-Models Electronic Analytical and Precision Balances. WLE5001-e04022

SAUTER FK Version /2016 GB

Digital Melting Point Apparatus

All Purpose AP-Series Operation Manual

Gas density monitor With integrated transmitter Model GDM-100-TI

Pneumatic high-pressure controller Model CPC7000

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Precision digital pressure gauge Model CPG1000

Operating Instructions Electronic Precision Balances 1 TECHNICAL DATA UNPACKING AND STANDARD EQUIPMENT INSTALLATION...

Introduction. Check for the following items before use.

High-performance submersible pressure transmitter For level measurement Model LH-20

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Digital pressure gauge Model CPG500

Pneumatic high-pressure controller Model CPC7000

9A5N Solid State CW Paddle

The New Quintix. Redefining Standard.

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

Pressure Automated Calibration Equipment

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

QRAE II Quick Reference Covers Diffusion & Pump Models with Firmware Version 3.12 and higher

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Sartorius Competence CP Series Sartorius Gem plus

Instruction Manual EMA 84 Digital Pressure Gauge

KERN YDB-03 Version /2015 GB

General Accreditation Guidance. User checks and maintenance of laboratory balances

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Adam Equipment PGL SERIES. (P.N. 9326, Revision C5, March 2009)

Hand-held pressure calibrator with integrated pump Model CPH6600

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

StockWeigh 500 D3632 US-B

High-performance submersible pressure transmitter For level measurement Model LH-20

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Heavy Duty Dissolved Oxygen Meter

Manual Weighingblock VB2 series and Uniscale

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Digital Vacuum Regulator

SPS-5. Rate Computing Scale. Operation Manual

Vapor Sorption Analyzer

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Instruction Manual Contact Pressure Vacuum Gauge

PERFORM Operating Document

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Use this key to determine which sections of this Product Manual apply to your job.

Owner s Manual Humiport 10/20

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Operating Instructions Part No

EC214 EC215 - EC215R Bench Conductivity Meters

Instruction Manual Dräger MSI P7 and MSI P7 plus

Installation Instructions

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

FPG8601 Force Balanced Piston Gauge

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Arena by Oregon Scientific

DK46 - DK800 Supplementary instructions

testo Leakage detector for refrigerants Instruction manual

Digital pressure gauge Model CPG500

The New Secura : Easy, Reliable Weighing in Regulated Areas

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Transcription:

User Manual Portable Balances PL-E

u www.mt.com/pl-e-oi u www.mt.com/library Portable Balances 3

Overview components 4 3 2 1 5 6 7 8 7 11 10 9 Components overview legend 1 Operation keys 2 Display 3 Adapter ring 4 Weighing pan 5 Level indicator 6 Bottom of balance: Battery compartment 7 Leveling feet 8 Model sticker Hanger opening for weighing below the balance 9 Socket for AC/DC Adapter 10 RS232C serial interface 11 Lug for optional antitheft device 4 Portable Balances

Overview operation keys 1 2 3 4 5 Terminal keys legend No. Key Press briefly (less than 1.5 s) Press and hold (longer than 1.5 s) 1 Printout display value Transmit data To navigate backward in the menu or menu selection Decrease parameters in menu or applications Open the application list and scroll among the weighing applications in certain sequence for selecting an application Exits an active application and returns to the selection for weighing mode 2 Zero setting Cancel and leave menu without saving One step back in the menu Cancel or leave application setting 3 Tare Switch on 4 With entries, scroll down To navigate forward menu topics or menu selections To toggle between unit 1, recall value (if selected), unit 2 (if different from unit 1) and the application unit (if any) Increase parameters in menu or applications 5 Enter or leave menu selection To enter application parameter and switch to next parameter To store parameter Switch off Execute predefined adjustment (calibration) procedure Enter or leave menu (parameter settings) Portable Balances 5

1 Safety Information Two documents named "User Manual" and "Operating Instructions" are available for this instrument. The User Manual shows you how to start using the instrument. The Operating Instructions contain a full description of the instrument and its use. Keep both documents for future reference. Include both documents if you transfer the instrument to other parties. Only use the instrument according to the User Manual and the Operating Instructions. If you do not use the instrument according to these documents or if the instrument is modified, the safety of the instrument may be impaired and Mettler-Toledo GmbH assumes no liability. Additional information about this balance can be found in the Operating Instructions on the CD- ROM or online. 1.1 Definitions of signal words and warning symbols u www.mt.com/pl-e-oi Safety notes contain important information on safety issues. Ignoring the safety notes may lead to personal injury, damage to the instrument, malfunctions and false results. Safety notes are marked with the following signal words and warning symbols: Signal words WARNING CAUTION NOTICE Warning symbols Electrical shock A hazardous situation with medium risk, possibly resulting in death or severe injury if not avoided. A hazardous situation with low risk, resulting in minor or moderate injury if not avoided. A hazardous situation with low risk, resulting in damage to the instrument, other material damage, malfunctions and erroneous results, or loss of data. General hazard: read the Operating Instructions for information about the hazards and the resulting measures. 1.2 Product specific safety notes Intended use This instrument is designed to be used in laboratories by trained staff. The instrument is intended for weighing purposes. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo GmbH is considered as not intended. Responsibilities of the instrument owner The instrument owner is the person holding the legal title to the instrument and who uses the instrument or authorizes any person to use it, or the person who is deemed by law to be the operator of the instrument. The instrument owner is responsible for the safety of all users of the instrument and third parties. METTLER TOLEDO assumes that the instrument owner trains users to safely use the instrument in their workplace and deal with potential hazards. METTLER TOLEDO assumes that the instrument owner provides the necessary protective gear. 6 Portable Balances

Safety notes WARNING Danger of death or serious injury due to electric shock! Contact with parts that carry a live current can lead to death or injury. 1 Only use the METTLER TOLEDO power supply cable and AC/DC adapter designed for your instrument. 2 Connect the power cable to a grounded power outlet. 3 Keep all electrical cables and connections away from liquids and moisture. 4 Check the cables and power plug for damage and replace damaged cables and power plugs. NOTICE 2 Design and Function 2.1 Display Risk of damage to the instrument due to the use of unsuitable parts! Using unsuitable parts with the instrument can damage the Instrument or cause it to malfunction. Only use parts from METTLER TOLEDO that are intended to be used with your instrument. Application Icons Status Icons Weighing-in aid Weight Value Field Unit Field Application icons Application weighing Application piece counting Application percent weighing Application check weighing Application statistics Application formulation / Net total Application totaling Application dynamic weighing Application multiplication factor Application division factor Application density Menu locked While an application is running, the corresponding application icon appears at the top of the display. Status icons Indicates stored value (Memory) Feedback for pressed keys Indicates net weight values Service reminder Adjustments (calibration) started Portable Balances 7

Weight value field and weighing-in aid Brackets to indicate uncertified digits (approved models only) SmartTrack (weighing-in aid) shows how much of the entire weighing range has been used. Indicates negative values Marking of nominal or target weight Indicates unstable values Marking of tolerance limit T+ Indicates calculated values Marking of tolerance limit T- Unit field g gram ozt troy ounce tls Singapore taels kg kilogram GN grain tlt Taiwan taels mg milligram dwt pennyweight tola tola ct carat mom momme baht baht lb pound msg mesghal oz ounce tlh Hong Kong taels 3 Installation and Putting into Operation Finding more information Additional information about this balance can be found in the Operating Instructions on the CD- ROM or online. Search for documents. u www.mt.com/pl-e-oi u www.mt.com/library WARNING Danger of death or serious injury due to electric shock! The instrument must be disconnected from the power supply before performing all setup and assembly work. 3.1 Unpacking and delivery inspection NOTICE Risk of damage to the instrument due to the use of unsuitable parts! Using unsuitable parts with the instrument can damage the Instrument or cause it to malfunction. Only use parts from METTLER TOLEDO that are intended to be used with your instrument. 1 Open the packaging and carefully remove all components. 2 Check the delivered items. The standard scope of delivery contains the following items Balance Weighing pan and weighing pan support Protective cover for load cell cone (mounted) 8 Portable Balances

Protective cover (mounted) Stackable cover Universal AC/DC adapter (country specific) Operating Instructions or User Manual; printed or on CD-ROM, depending on country of use Declaration of conformity 3.2 Selecting the location A good location will enable the balance to work accurately and reliably. The surface must be able to safely take the weight of the balance when fully loaded. The following local conditions must be observed: If the balance is not horizontal at the outset, it must be leveled during commissioning. Operate the balance in indoor environments only and at an altitude of less than 4000 m above sea level. Before switching on the balance, leave the parts to reach room temperature (+5 to 40 C). Ensure that the relative humidity is between 10% and 80% and non-condensing conditions are met. The power plug must be easily accessible. No powerful vibrations No direct sunlight No excessive temperature fluctuations. No powerful drafts. No powerful electric or magnetic fields Ensure that the surroundings as free from dust as possible. 3.3 Installing the components 1 Remove the protective cover for weighing cone (1). Keep it for later use. 2 Place the following components on the balance in the specified order: Pan support (2) Weighing pan (3) 3 2 1 Portable Balances 9

3.4 Installation of the protective cover Install the protective cover according to the illustration on, using a screwdriver. 3.5 Connecting the balance WARNING Danger of death or serious injury due to electric shock! Contact with parts that carry a live current can lead to death or injury. 1 Only use the METTLER TOLEDO power supply cable and AC/DC adapter designed for your instrument. 2 Connect the power cable to a grounded power outlet. 3 Keep all electrical cables and connections away from liquids and moisture. 4 Check the cables and power plug for damage and replace damaged cables and power plugs. NOTICE Danger of damage to the AC/DC adapter due to overheating! If the AC/DC adapter is covered or in a container, it is not sufficiently cooled and will overheat. 1 Do not cover the AC/DC adapter. 2 Do not put the AC/DC adapter in a container. The balance is supplied with an universal AC/DC adapter. Install the cables so that they cannot be damaged or interfere with operation. Insert the power cable in a grounded power outlet that is easily accessible. 10 Portable Balances

Connect the AC/DC adapter to the connection socket on the back of your balance (see figure) and to the power line. ð The balance is ready for use. 3.5.1 Battery operation The balance can also operate with batteries. Under normal operation conditions, the balance works independently of the AC power line for about 8 to 15 hours (using alkaline batteries). It is also possible to use rechargeable batteries. Charging batteries inside the balance is not possible. Your balance uses 4 standard AA (LR6) batteries (alkaline batteries preferred). Inserting / replacing batteries WARNING Danger of death or serious injury due to electric shock! Contact with parts that contain a live current can lead to injury and death. Disconnect the instrument from the power supply when replacing batteries. NOTICE Risk of damage to the balance Do not place the balance on the pan support location bolt. Read and follow all warnings and instructions supplied by the battery manufacturer. Do not mix different types or brands of batteries. Performance of batteries varies depending on the manufacturer. Remove the batteries from the balance if the balance is not used for a long period of time. Batteries must be disposed of properly, according to local regulations. Make sure that the balance is off before removing or inserting batteries. 1 Remove weighing pan and pan support. 2 Turn the balance carefully on its side. Portable Balances 11

3 Open and remove the battery-chamber cover. 4 Insert / replace the batteries with the correct polarity as shown in the battery holder. 5 Insert and close the battery-chamber cover. 6 Turn the balance carefully to its normal position. 7 Reinstall all components in the reverse order. + - - + + - - + 3.6 Setting up the balance 3.6.1 Switching on the balance Before using the balance, it must be warmed up in order to obtain accurate weighing results. To reach operating temperature, the balance must be acclimatized and connected to the power supply for at least 30 minutes. Mains operated (standby mode) The balance is connected to the power supply. Press. ð The balance performs a display test. All segments in the display light up briefly, WELCOME, Software version. Maximum load and Readability appears briefly. ð The balance is ready for weighing or for operation with the last active application. MT.GREEN Battery operated 1 Remove any load from weighing pan. 2 Press. ð The balance performs a display test (all segments in the display light up briefly), WELCOME, Software version, Maximum load and Readability appears briefly. ð After the warm-up time, the balance is ready for weighing or for operation with the last active application. Legal-for-trade Approved balances will execute an initial zero. 3.6.2 Leveling the balance The balances have a level indicator and two or four adjustable leveling feet to compensate for slight irregularities in the surface of the weighing bench. The balance is exactly horizontal when the air bubble is in the middle of the level glass. The balance must be leveled and adjusted each time it is moved to a new location. 12 Portable Balances

1 Align the balance horizontally. 2 Turning the leveling feet of the balance housing until the air bubble is in the inner circle of the level indicator. 3.6.3 Adjusting the balance To obtain accurate weighing results, the balance must be adjusted to match the gravitational acceleration at its location and depending on the ambient conditions. After reaching the operation temperature, adjusting is necessary. before the balance is used for the first time. after a change of the location. at regular intervals during weighing service. See also 2 Adjustment with external weight } Page 13 3.7 Adjustment with external weight Legal-for-trade Approved models must be adjusted at the place of operation. Before putting in operation, and depending on particular country certification legislation, the balance will then have to be checked and sealed by authorized personnel. See the detailed information delivered with this balance. In the menu topic CAL (Adjustment) of advanced menu ADJ.EXT must be selected. Required adjustment weight is ready. Weighing pan is unloaded. 1 Press and hold CAL to execute external adjustment. ð The required (predefined) adjustment weight value flashes on the display. 2 Place adjustment weight in center of pan. ð The balance adjusts itself automatically. 3 Remove adjustment weight, when flashes. ð The adjusting is finished when the message ADJ DONE appears briefly on the display. The balance returns to the last active application and is ready for operation. Cal ADJ.EXT 200 ------ ------ ADJ.DONE Portable Balances 13

3.8 Performing a simple weighing The weighing application allows you to perform simple weighings and how you can accelerate the weighing process. If your balance is not in the weighing mode, press and hold the display. Press. Your balance is in the weighing mode. 1 Press to zero the balance. 2 Place the sample on the weighing pan. 3 Wait until the instability detector disappears and the stability beep sounds. 4 Read the result. key down until WEIGH appears in the 1182.03 g 1250.38 g Zeroing Use the zeroing key before you start with a weighing. 1 Unload the balance. 2 Press to zero the balance. ð All weight values are measured in relation to this zero point. 121.01 g 0.01 g Taring If you are working with a weighing container, first set the balance to zero. 14 Portable Balances

1 Place empty container on the weighing pan. ð The weight is displayed. 2 Press to tare the balance. ð and Net appears in the display. Net indicates that all weight values displayed are net values. 3 Place the sample in the container. ð The result appears in the display. If the container is removed from the balance, the tare weight will be shown as a negative value. 121.01 g Net Net 95.97 g - Net 121.01 g Switching weight units The key can be used at any time to toggle between weight unit UNIT 1, RECALL value (if selected) and weight unit UNIT 2 (if different from weight unit 1) and the application unit (if any). Press to set weight unit or recall value. 22.00 g * M 22.00 g 0.78 oz Recall / recall weight value Recall stores stable weights with an absolute display value bigger than 10d. Portable Balances 15

Function RECALL is in the menu activated. 1 Load weighing sample. ð The display shows weight value and stores stable value. 2 Remove weighing sample. ð The display shows zero. 3 Press. ð The display shows last stored stable weight value for 5 seconds together with asterisk (*) and memory (M) symbols. After 5 seconds the display goes back to zero. This can be repeated unlimited times. 121.01 g M 121.01 g Delete last weight value As soon a new stable weight value is displayed, the old recall value becomes replaced by the new weight value. Press. ð The recall value is set to 0. If the power is switched off, the recall value is lost. The recall value can not be printed. Weighing with the weighing-in aid The weighing-in aid is a dynamic graphic indicator which shows the used amount of the total weighing range. You can thus recognize at a glance when the load on the balance approaches the maximum load. 100% 0% Print / transmit data Press the key to transmit the weighing results over the interface e.g. to a printer or a PC. 4 Maintenance 4.1 Cleaning and service Every now and then, clean the weighing pan, draft shield element, bottom plate, draft shield (depending on the model) and housing of your balance. Your balance is made from high-quality, durable materials and can therefore be cleaned using a damp cloth or with a standard, mild cleaning agent. 16 Portable Balances

Please observe the following notes WARNING Danger of death or serious injury due to electric shock! Contact with parts carrying a live current can lead to injury and death. 1 Disconnect the balance from the power supply prior to cleaning and maintenance. 2 Only use METTLER TOLEDO power cables if they need to be replaced. 3 Prevent liquid from entering the balance, terminal or AC/DC adapter. 4 Do not open the balance, terminal or AC/DC adapter. They do not contain any parts that can be serviced by the user. NOTICE Risk of damage to balance due to inappropriate cleaning methods The balance is made from high quality, resistant materials and can be damaged by certain cleaning agents, solvents or abrasives. Any liquid that enters the housing may damage the balance. 1 Use water and a mild detergent to clean the balance or terminal. 2 Wipe off any spills immediately. 3 Prevent liquid from entering the interior of the balance. Contact a METTLER TOLEDO representative to find about the service options available regular maintenance by an authorized service engineer will ensure consistent weighing accuracy over the long term and extend the service life of the balance. 5 Technical Data 5.1 General data WARNING Danger of death or serious injury due to electric shock! Contact with parts that contain a live current can lead to injury and death. 1 Only use an approved AC/DC adapter with a current-limited SELV output. 2 Ensure correct polarity Standard power supply AC/DC adapter: Balance power supply: Battery operation: Primary: 100 240 V, ±10%, 50/60Hz, 0.3 A Secondary: 12 V DC, 0.84 A (with electronic overload protection) 12 V DC, 0.84 A Can be used up to 2000 m above mean sea level. 4 standard AA (LR6) batteries (alkaline) for 8 15 hours of use NOTICE If the balance is used above 2000 m mean sea level, the optional power supply must be used. Optional power supply AC/DC adapter: Primary: 100 240 V, ±10%, 50/60Hz Secondary: 12 V DC ±3%, 2.5 A (with electronic overload protection) Portable Balances 17

Cable for AC/DC adapter: Balance power supply: 3-core, with country-specific plug 12 V DC ±3%, 2.25 A, maximum ripple: 80 mvpp Can be used up to 4000 m above mean sea level. Protection and standards Overvoltage category: II Degree of pollution: 2 Protection: Protected against dust and water Standards for safety and EMC: See Declaration of Conformity Range of application: For use in closed interior rooms only Environmental conditions Height above mean sea level: Depending on the power adapter (2000-4000 m) Except for China: max. 2000 m Ambient temperature: Operating conditions for ordinary lab application: +10 to 30 C (operability guaranteed between +5 and 40 C) Relative air humidity: 10% up to 80% at 31 C with a linear decrease to 50% at 40 C, non-condensing Warm-up time: At least 30 minutes (60 minutes for 0.1 mg models) after connecting the balance to the power supply. When switched on from standby, the instrument is ready for operation immediately. Materials Housing: Housing: Plastic (ABS/PC) Weighing pan: ø 160 mm: Stainless steel X5CrNi 18-10 (1.4301) 18 Portable Balances

www.mt.com/ple-precision For more information Mettler-Toledo GmbH Im Langacher 44 8606 Greifensee, Switzerland www.mt.com/contact Subject to technical changes. Mettler-Toledo GmbH 11/2017 30357040E en 30357040