S Loadbreak Apparatus Connectors WARNING: WARNING:

Similar documents
COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with optional integral jacket seal installation instructions. Loadbreak Connectors MN650008EN

COOPER POWER SERIES. 200 A 15 and 25 kv class elbow with integral jacket seal* for use on tape and wire shielded cable installation instructions

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. 200 A 35 kv class LE series elbow installation instructions. Loadbreak Apparatus Connectors MN650010EN

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

DT400/436 Tee Connector Installation Instructions

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

600 A 35 kv class PUSH-OP deadbreak connector installation instructions

COOPER POWER SERIES. 600 A 35 kv class PUSH-OP deadbreak connector installation instructions. Deadbreak Apparatus Connectors MN650052EN

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

Effective May 2017 Supersedes July 2009 (S ) 600 A 35 kv Class T-OP II connector assembly installation instructions 200 A PROTECTIVE CAP LRTP

COOPER POWER SERIES. 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions. Bushings MN650045EN

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

Effective March 2015 Supersedes S August 2002

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

COOPER POWER SERIES. VariSTAR Storm Trapper high energy MOV arrester installation instructions. Surge Arresters MN235017EN

DAI630TB2669 Dead Front Arrester Installation Instruction

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

S Surge Arresters

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

COOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.

COOPER POWER SERIES. Operation Counter Replacement Instructions. Reclosers MN280047EN. Effective May 2016 Supersedes S December 2003

Effective January 2017 Supersedes July 2011 (I ) VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions

ESA Elbow Sealing Adapter Kit

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

INSTALLATION & MAINTENANCE INSTRUCTION

COOPER POWER SERIES. Types E, 4E, V4E, H, 4H, V4H, L, and V4L single-phase recloser installation and operation instructions. Reclosers MN280051EN

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

DK ton, Double-acting, Die-type Crimping Tool

Booster Pump PB4-60 Replacement Kits

Hydraulic Punch Drivers

750 Cable Cutter INSTRUCTION MANUAL

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Model 23H Hand Crank Seamer

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Pressure Dump Valve Service Kit for Series 2300 Units

General No. 25 and D-25 Handy Operating Instructions

FLEXIBLE SHAFTING (Wet & Dry)

ROPV R40 E Series User Manual

Work Standard CABLE PULLING OPERATIONS

Fiber Cable Puller with Tuf-Lugger lite

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

BUTTERFLY VALVES Series 800

Instruction Sheet. CP2000: 2000 lb Cable Puller IMPORTANT RECEIVING INSTRUCTIONS SAFETY ISSUES

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

DM-MARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike REAR DERAILLEUR XTR RD-M9100 RD-M9120

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Front derailleur. Dealer's Manual DURA-ACE FD-R9100 ULTEGRA FD-R FD ROAD MTB Trekking. City Touring/ Comfort Bike DM-RAFD001-03

Original Date of Issue: 04/09

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Sunbrite LTC Large Underwater Pool Lights

Pre-Paint>Fuselage>Empennage>Fit vertical tail fin. Objectives of this task: Materials and equipment required: Fit the spar extender

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

S Vacuum Switches. Contents. Type VCS-1 Single-Phase Vacuum Capacitor Switch Installation and Operation Instructions

SIG SAUER ENHANCED AUTO MIL SPEC TRIGGER KIT INSTALLATION INSTRUCTIONS

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Synthetic Rope Installation Guide Premium, Ultra Performance & Zeon Winch Lines

Type BBS-03, BBS-05, BBS-06, BBS-25

CHAPTER 2 MAINTENANCE

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

FRAME FEATURES TABLE OF CONTENTS INTRODUCTION

IMPORTANT: RECEIVING INSTRUCTIONS:

Inspection Recommendations

plasmarc air curtain For use with m3 Plasma System and PT-36 Plasma Torch ESAB Assembly Number: Instruction Manual gas the bottom of the plate.

Pressure Dump Valve Service Kit for Series 3000 Units

SASK-A-POLE OWNERS AND USERS MANUAL

BMW Motorrad. Installation Instructions. BMW Motorrad Communications System for Schuberth C3

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Hydraulic Punch Drivers

GM-7000 Series CE Approved Gas Control Valve

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

FULLY READ WARNINGS BEFORE OPERATING! AMERICAN MADE AND BACKED BY A 3-YEAR WARRANTY

TABLE OF CONTENTS FRAME FEATURES INTRODUCTION

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

Butler Parachute Systems, Inc

Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions

Shifting Lever. RAPIDFIRE Plus 11-speed

Transcription:

Loadbreak Apparatus Connectors 200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal* Installation Instructions Service Information S500-10-2 SEMI-CONDUCTING SHIELD LOCKING RING PULLING EYE LOADBREAK PROBE COPPERTOP CONNECTOR ARC FOLLOWER SEMI-CONDUCTIVE INSERT DRAIN WIRE TAB TEST POINT INSULATION ENCAPSULATED CONDUCTIVE INSERT ENDS LOADBREAK BAND EPDM INSULATION 5 kv CABLE ADAPTER Figure 1. Line illustration of 200 A 15 kv Loadbreak Elbow with 5 kv Cable Adapter. Contents General.................................... 1 Safety Information........................... 2 Product Information.... 3 Installation Procedures... 3 Preparation of Concentric Neutral Cable...... 3 Elbow and Loadbreak Probe Installation...... 6 Operating Instructions........................ 8 Loadmake Operation.... 8 Fault Close.... 8 Loadbreak Operation.... 8 All associated apparatus must be de-energized during any hands-on installation or maintenance. Failure to comply could result in death, severe personal injury and equipment damage. Optional Capacitive Test Point Operating Instructions: Use only volt age in di cat ing in struments spe cif i cal ly de signed for test points. Use of convention al volt age sensing devices may provide false No Voltage indications. The test point must be dry and free of con tam i nants when checking for voltage. After indication is taken: clean, dry, and lubricate the test point cap with silicone grease and assemble to the test point. Always consider the termination to be energized until the test point No Voltage indication is confirmed by other means. Failure to comply could result in death or severe personal injury. February 2014 Supersedes March 2011 1

200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal Installation Instructions SAFETY FOR LIFE SAFETY FOR LIFE Eaton's Cooper Power Systems products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton's Cooper Power Systems employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission. SAFETY FOR LIFE The instructions in this manual are not intended as a sub stitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION: Indicates a hazardous situation which, if not avoided, could result in equipment damage only. SAFETY INFORMATION Safety Instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER: Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. 2

S500-10-2 Introduction Eaton's Cooper Power Systems Loadbreak Elbow Connector is a fully-shielded and insulated plugin termination for connecting underground cable to transformers, switching cabinets and junctions equipped with loadbreak bushings. The elbow connector and bushing insert comprise the essential components of all loadbreak connections. Read This Manual First Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment Additional Information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user's purpose, please contact Cable stripping and scoring tools, available from various tool manufacturers, are recommended for use when installing loadbreak elbows. After preparing the cable, the elbow housing is pushed onto the cable. The load-break probe is threaded into the coppertop connector using the supplied installation tool or an approved equivalent. Use a clampstick to perform loadmake and loadbreak operations. (See page 8 for operating instructions.) Complete elbow kit includes: Standard 15 kv "CC" Elbow Body or 15 kv "CC" Elbow Body with Jacket Seal Coppertop Compression Connector Loadbreak Probe Probe Installation Tool Silicone Lubricant Mastic Strips (Jacket Seal Elbow Only) Installation Instruction Sheet Tools/Accessories needed: Tape Measure Wire Brush Knife Cable Stripping Tool Crimping Tool Cable Cleaner Cable Cutters Emery Cloth Clampstick Personal Protection Equipment PRODUCT INFORMATION INSTALLATION PROCEDURES your Eaton's Cooper Power Systems sales representative. Acceptance and Initial Inspection Each Loadbreak Elbow Connector is completely inspected and tested at the factory. It is in good condition when accepted by the carrier for shipment. Upon receipt of a Loadbreak Elbow Connector Kit, inspect the connector thoroughly for damage and loss of parts incurred during shipment. If damage or loss is discovered, file a claim with the carrier immediately. Handling and Storage If the Loadbreak Elbow Connector is to be stored for an appreciable time before installation, provide a clean, dry storage area. Locate the connector so as to minimize the possibility of physical damage. Quality Standards ISO 9001Certified Quality Management System PREPARATION OF CONCENTRIC NEUTRAL CABLE NOTE: Stripbacks shown in these instructions for concentric neutral cable are the same for tape shielded and drain wire cables. Refer to shield adapter kit being used for metallic shield stripbacks. Cable Training Position cable vertically so that it is centered between apparatus bushing and parking pocket, parallel to the apparatus frontplate. Provide adequate slack in the cable to permit unrestricted movement of the elbow connector from the apparatus bushing to a standoff bushing or portable feedthru. Once installed, the cable should enter the elbow connector in a straight line. Avoid a tight bend radius at the cable entrance of the elbow that causes the elbow to bend. (See Figure 2.) Correct Incorrect Figure 2. Proper Cable Training. 3

200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal Installation Instructions Step 1 Step 2 Step 3 Step 4 REMOVE EXCESS SQUARE CUT 2 1 / 8 " (54 mm) CONDUCTOR 1 / 8 " BEVEL (3 mm) 1 / 8 " BEVEL (3 mm) 6" (152 mm) 11 1 / 2 " (292 mm) 8 " - 8 1 / 2 " (203-216 mm) INSULATION SHIELD INSULATION SHIELD 7" (178 mm) 5 kv CABLE ADAPTER VINYL TAPE MARKER FLUSH WITH TAPE MARKER BEND NEUTRAL WIRES DOWN AND OUT OF THE WAY CABLE JACKET STEP 1 Measure down from top of the cable a minimum of 11 1/2" (292 mm). Remove cable jacket (if jacketed cable is used) to expose neutral wires. Unwind neutral wires. Measure up 8" to 8 1/2" (203 to 216 mm) and make a square cut to remove excess cable. STEP 2 Measure down from the top of the cable 2 1/8". Remove the insulation and conductor shield to expose the bare conductor. Take care not to nick the conductor. STEP 3 Measure down from the top of the exposed conductor 6". Remove the insulation shield, taking care not to nick or gouge the insulation. Measure down from the top of the exposed conductor 7" and apply vinyl tape marker. Place a 1/8" bevel on the insulation to ease cable adapter and elbow installation. STEP 4 Clean the insulation with a lint free cloth saturated with a cleaning solution. Wipe the insulation towards the insulation shield. Apply a thin layer of supplied lubricant to the cable insulation and inner bore of the 5 kv cable adapter. Slide the cable adapter over the cable until the black end of the adapter is flush with the top of the vinyl tape marker. A positive stop as the step in the cable adapter meets the insulation shield will also be felt. STEP 5 Clean the exposed conductor using a wire brush. NOTE: The probe (male contact) should be preassembled into the threads of the compression connector prior to crimping to ensure proper thread engagement. Place the coppertop (bimetal) connector on the conductor. Make sure the threaded hole in connector faces the apparatus bushing. Crimp the connector in place using a tool and die combination and minimum suggested number of crimps ( ) as shown in Table 1 on page 8. Start crimping just below 4

S500-10-2 Step 5 Step 6 Step 7 Step 8 FIRST CRIMP PLACED BELOW KNURL CLEAN EXCESS INHIBITOR GREASE KEEP BEND RADIUS AS SMALL AS POSSIBLE FIRST MASTIC LAYER 1/2" SECOND MASTIC LAYER 1/2" TRANSITION POINT PRESS TIGHTLY TO FILL IN VOIDS THIRD MASTIC LAYER PRESS TIGHTLY IN PLACE CABLE JACKET CONCENTRIC NEUTRALS the knurled line and rotate each successive crimp to prevent bowing. Do not overlap crimps. Clean excess inhibitor grease from coppertop connector by wiping toward threaded eye. Smooth any sharp edges on the crimp connector surface. NOTE: If Eaton's Cooper Power Systems Standard Elbow is used, proceed to Step 10. If Eaton's Cooper Power Systems Integral Jacket Seal Elbow is used, proceed to Step 6. STEP 6 Apply first supplied mastic strip around the cable jacket approximately 1/2 inch below the point where the jacket is removed. Do not stretch mastic when installing. Bend the concentric neutral strands back as tightly as possible against the cable, forming as small a radius as possible. Press the neutral wires into the mastic strip. STEP 7 Apply second layer of mastic over the neutrals directly on top of the first layer. Press tightly to fill in any voids. Do not stretch mastic when installing. STEP 8 Apply the third layer of mastic centering it on the transition point of the stripped back jacket and insulation shield. Press tightly in place. Do not stretch mastic when installing. 5

200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal Installation Instructions Step 9 Step 10 Step 11 CC CC Electrical Tape Elbow with Integral Jacket Seal shown Elbow with Integral Jacket Seal shown STEP 9 Wrap the cable and mastic with one half-lapped layer of vinyl electrical tape (User Supplied). The tape should extend from just above the third mastic applied at the transition point, to just below the first and second mastic onto a portion of the jacket still in place. ELBOW AND LOADBREAK PROBE INSTALLATION STEP 10 Clean the outside of the cable adapter with a lint free cloth saturated with a cleaning solution. Apply a thin layer of supplied lubricant to the cable adapter and the cable entrance of the elbow. Place the elbow on the cable and with a twisting motion push the elbow downward over the cable adapter until the threaded eye of the coopertop connector is aligned with the elbow. NOTE: The cable adapter must remain aligned with the vinyl tape marker. If the cable adapter slips down, push back into the elbow cable entrance until aligned with tape marker. NOTE: If Eaton's Cooper Power Systems Standard Elbow is used, proceed to Step 12. If Eaton's Cooper Power Systems Integral Jacket Seal Elbow is used, proceed to Step 11. STEP 11 Apply a thin layer of supplied silicone grease over the cable and vinyl tape. Grasping the thumbholes of the jacket seal, pull down firmly over the cable until all of the vinyl tape is covered. 6

S500-10-2 Step 12 CC Elbow with Integral Jacket Seal shown STEP 12 Push down and twist the elbow to align the coppertop compression connector, the threaded hole in the connector should be centered with respect to the hole in the elbow and perpendicular to the probe axis. By hand, insert the probe into the elbow along the center axis of the interface and thread the loadbreak probe into the coppertop connector. A thin layer of silicone lubricant applied to the last 1/4" of the probe body (not on the threads) can aid in installation. After at least three full turns or when the probe is seated (5 1/2 turns) onto the connector, use the provided installation tool to properly torque the loadbreak probe. Proper torque is applied when the tool twists at least 180 (1/2 turn). NOTE: If a different installation tool is used it must apply a torque of 100 to 120 lbf-in (11.0-13.5 N-m). Clean and lubricate bushing and elbow interface areas with a thin even coating of the silicone lubricant provided. Attach a drain wire lead to the drain wire eye of the elbow. 7

200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal Installation Instructions TABLE 1 Crimp Chart Do not connect two different phases of a multiple-phase system. Before closing a single-phase loop, make certain both ends of the loop are the same phase. Loadmake Operation Area must be clear of obstructions or contaminations that would interfere with the operation of the loadbreak elbow. Securely fasten a clampstick to the pulling eye of the elbow. Place the loadbreak elbow over the bushing, inserting the white arc follower of the probe into the bushing approximately 2 1/2 until a slight resistance is felt. This will align and stabilize the elbow. Turn your back to the bushing and grasp the clampstick securely and obtain good footing. Slam the elbow onto the bushing with one quick and continuous motion. Turn around and apply a force to the clampstick to push the elbow onto the bushing. A popping or snapping sound is often heard when this operation is performed. 8 CONNECTOR 5 / 8 DIAMETER 3 / 4 DIAMETER CONDUCTOR SIZE NO. 4 THRU 2/0 STRANDED 3/0-4/0 STRANDED BURNDY Thomas and Betts KEARNEY TOOL Y34 Y35 OR Y39 MD6 Y34 Y35 OR Y39 MD6 DIE A243 A25AR U243 U25ART UBG U687 The operator should always use personal protective equipment (insulated gloves, clampstick and eye protection) whenever operating the elbow. The operator should always be in the best possible operating position, providing firm footing and enabling a secure grasp of the clampstick, while maintaining positive control of the elbow before, during and immediately after operation. If there is any question regarding the operator s operating position, de-energize the elbow before operation. The operator should not be looking directly at the connector during the moment of circuit interruption or connection. Failure to comply could result in death or serious injury. W243 (3) BG (4) NOSE WBG W687 U247 A27AR U247 U467 U27ART (1) TOOL UT-3 UT-5 UT-15 UT-5 UT-15 DIE 5 / 8 (4) TV (4) 54 H TV (4) 66 TOOL DIE 5 / 8 NOSE (4) O WH2, WH3, BH4, WH4, PH2, PH13 O W247 (5) WH2, WH3, BH4, WH4, PH2, PH13 9/16 (3) 9/16 572 737 (3) 747 737 (3) 747 ACA TOOL 12 A 12 A Conductor Accessories DIE B24 EA B39 EA Anderson Tool VC-5, VC-6 VC-5, VC-6 Edison Electric Institute - REFERENCE 8 A 10 A ( ) Minimum suggested number of crimps. OPERATING PROCEDURES To check that the elbow is properly latched apply a gentle pull force to the clampstick. When latched properly the elbow will not slide back off of the bushing. As a last operation, push on the clampstick to seat the elbow all the way onto the bushing again. This insures that the elbow is latched and was not dislodged during the latching check in previous step above. Fault Close 1. It is not recommended that operations be made on known faults. 2. If a fault is experienced, the elbow connector, probe, and the bushing must be replaced. Loadbreak Operation Area must be clear of obstructions or contaminants that would interfere with this operation. Use clampstick to secure standoff insulator or portable feedthru in bracket. Ground devices to system ground per appropriate Installation Instructions. All associated apparatus must also be grounded. Secure elbow eye firmly onto clampstick and lock. Twist clampstick clockwise until the elbow rotates slightly on bushing about 1 /4 (7 mm). This action will break any surface friction between outer surface of bushing and inner surface of elbow. Withdraw elbow from bushing with a fast, firm, straight motion. Minimum amount of travel of elbow to break load is 9 (229 mm). Use clampstick to place elbow on lubricated standoff insulator or portable feedthru. (Follow loadmake instructions.) Place an insulated protective cap with ground wire attached to system ground on any exposed energized bushing using clampstick. Follow the same operating procedures as for the elbow as outlined above under Loadmake Operation.

S500-10-2 This page intentionally left blank. 9

200 A 15 kv Class Elbow with 5 kv Cable Adapter and Optional Integral Jacket Seal Installation Instructions This page intentionally left blank. 10

S500-10-2 This page intentionally left blank. 11

200 A 15 kv and 25 kv Class Elbow with Optional Integral Jacket Seal Installation Instructions 6" (152 mm) 2 1 / 8 " (54 mm) SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Business 2300 Badger Drive Waukesha, WI 53188 cooperpower.com 2014 Eaton All Rights Reserved Printed in USA Publication No. S500102 Rev 2 Supersedes S500102 Rev 1 Eaton, Cooper Power Systems, and Kearney are valuable trademarks of Eaton, in the U.S. and other countries. You are not permitted to use these trademarks without the prior written consent of Eaton. Burndy is a registered trademark of FCI Thomas and Betts is a registered trademark of Thomas and Betts. ACA Conductor Accessories is a division of AFL Telecommunications LLC Anderson is a registered trademark of Hubbell Power Systems 12