Flare Gas Mass Flow Metering Innovations Promise More Economical Choices

Similar documents
Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

analytical bulk flow distance FLOW level pressure temperature industrial communication

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

deltaflowc deltaflowc Venturi or Probe

Drilling Efficiency Utilizing Coriolis Flow Technology

Calibrating and Monitoring MUSMs in Natural Gas Service

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Gas Turbine Performance Analysis

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Simplicity in VRU by using a Beam Gas Compressor

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

SideTrak 830/840. Process Gas Mass Flow Meters and Controllers. FEATURES DESCRIPTION

Flow metering in gases Introduction to COMBIMASS family

Flare Gas Measurement in B.C., Alberta, and Saskatchewan Using GE Ultrasonic Metering Technology

FIRE PROTECTION. In fact, hydraulic modeling allows for infinite what if scenarios including:

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

780S Ultra High Purity Series

1 PIPESYS Application

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Features. Description

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Thermal Mass Flowmeters. 5 Mass Flowmeters

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

THERMAL MASS FLOW MEASUREMENT FOR GASES

Discovery HP-TGA 75/750. Site Preparation Guide

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Valve Replacement: Using Non-Intrusive Isolation Technology to Minimize Production Downtime

Improving distillation tower operation

Operational Settings:

Automatic Isokinetic Sampler. ST5 Evo

Products Solutions Services. Gas Flow Measurement

Measurement & Analytics Wet gas monitoring

FAQs about Directive 017

Interchangeability Criteria.

Ultra High Purity Model 780S

TABLE OF CONTENTS LIST OF FIGURES

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Micro Motion 3098 Gas Specific Gravity Meter

InstrumentationTools.com

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

CAMASS. Calibration Centre. Gas flow technology and services

44 (0) E:

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Chapter 22 Testing Protocols

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

CAMASS. Calibration Centre. Gas flow technology and services

EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Improve Process Reliability

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Sampling Considerations for Equilibrium Dissolved Oxygen [DO] Sensors

Application Note AN-107

Applied Technology and Best Practices in CEE. Conference

TP Validating a dynamic grid model with tracer gas injection and analysis

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

GAS SUPPLY DESIGN GUIDE

Gas Transportation Planning System in the Department of Economy of Gazprom

Enbridge Pipelines (NE Texas) LP EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

AN INNOVATIVE APPROACH TO OPTIMIZE REVERSE OSMOSIS MEMBRANE PERFORMANCE

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

High Performance Digital Gas Mass Flow Meters & Controllers

Digester Processes. 1. Raw Sludge Pumping System

Responding to Natural Gas Pipeline Emergencies

Automatic Isokinetic Sampler. ST5 Evo

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Real-time Wobbe Index Determination of Natural Gas. J.C. Lötters Bronkhorst

Level MEASUREMENT 1/2016

Non-intrusive Natural Gas Flow Measurement

Every things under control High-Integrity Pressure Protection System (HIPPS)

Flowmeter Shootout Part II: Traditional Technologies

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation

Mass Flow Controller (MFC) for Gases

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study

"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

Transcription:

Flare Gas Mass Flow Metering Innovations Promise More Economical Choices By Matthew J. Olin, President, Sierra Instruments, Inc. A S I E R R A W H I T E P A P E R www.sierrainstruments.com N O R T H A M E R I C A 5 Harris Court, Building L / Monterey, CA 93940 / USA 800.866.0200 / 831.373.0200 / fx 831.373.4402 E U R O P E Bijlmansweid2 / 1934RE Egmond aan den Hoef The Netherlands +31 72 5071400 / fx +31 72 5071401 A S I A - P A C I F I C Second Floor Building 5 / Senpu Industrial Park 25 Hangdu Road Hangtou Town / Pu Dong New District Shanghai, P.R. China Post Code 201316 +8621 5879 8521/22 / fx +8621 5879 8586

INTRODUCTION As the drive towards energy independence in the United States continues at full speed, oil and gas companies are turning to hydraulic fracturing to increase production. Increasingly stringent state and national regulations for flare gas in particular now require the installation of mass flow measurement instruments to measure waste and excess gases burned off as a result of the hydraulic fracturing process. For gas wells alone, the EPA estimates that the cost of compliance will rise to $754 million per year by 2015. 1 Given the immense number of flares that are to be regulated, there is a need for more cost-effective mass flow measurement technologies. Multi-path ultrasonic flow meters have been widely used for flare gas measurement, but they are extremely expensive and have marked limitations. To comply with regulations, oil and gas companies need new flow meter alternatives that are accurate, durable, reliable and economical. This paper reviews flare gas flow measurement challenges and describes how several recent innovations in thermal mass flow sensor technology gives end-users an alternative metering choice to consider. Of particular interest is four-sensor thermal technology coupled with an advanced math model algorithm that works in tandem with the American Gas Association s (AGA) compliant gas property database. In combination, these technologies allow the user to adjust the instrument and retain accuracy as flare gas compositions change in the field over time. The ability of this new breed of four-sensor thermal meter to adjust for changing gas compositions gives end-users a significantly lower cost alternative to four-path ultrasonic meters. 1

Background: Hydraulic Fracturing Hydraulic fracturing is used to release oil and natural gas from wells drilled into reservoir shale rock formations called shale plays. While fracturing itself is not new (first done in 1947), it is the perfecting of horizontal-drilling techniques that have made it economical to exploit these shale plays. The oil produced using these techniques and other new exploration technologies is poised to make the USA the world s largest producer of oil by 2020. 2 The process of hydraulic fracturing releases large amounts of natural gas. While this is the objective in fracturing a natural gas well, some natural gas is inevitably released during the well completion (called flow back). Oil wells almost always produce natural gas ( associated gas ) along with the petroleum. In many cases, it is uneconomical to process due to heavy contamination. Many of the newer fracturing discoveries do not have the pipelines, compressors and gas plant infrastructure to collect this gas. As a consequence, this gas is combusted, flared off or simply vented as-is. When all sources are considered, over 150 billion cubic meters are flared or vented globally every year. This is equal to 25% of the United States natural gas consumption in 2012. 3 Methane itself is a very potent greenhouse gas, while the carbon dioxide, soot and other contaminants in flared gas are also significant pollutants. Flare Gas Measurement Challenges In order to comply with state and federal regulations, oil and gas companies need to invest in mass flow measurement equipment to measure flare gas flowing to: the combustor, vented gas from storage tanks, gas used as fuel, and/or gas sent to the grid for sale. Each well has its unique and constantly changing characteristics that include depth, temperature, pressure, flow rate, soot content and changing gas composition. This makes accurate flare gas measurement very challenging. To comply with stringent state and federal regulations, engineers at oil and gas companies must assess which flow measurement technology yields the highest accuracy with the lowest installation and cost-of-ownership over the lifetime of the well. The choice of flow measurement technology for flare gas measurement needs to perform under the following application challenges: Wide Flow Rate Variations Turndowns of up to 1,000:1 may be required. Non-Uniform Flow Profile Flare stacks generally have asymmetric and swirling flow. Very Low Pressure with Variable Temperatures Most flare headers operate at near atmospheric conditions. Gas temperature varies with well depth and reservoir characteristics. Dirty Flares Versus Clean Flares Many flares have significant amounts of dirt, hydrogen sulfide, wax, tar, and other paraffins that make for a dirty, sooty flame. Maintenance Is Difficult and Costly Roaring flames, difficult access and regulatory requirements make flares difficult to service. Wide Gas Density Variations Flare gas composition, and thus the density of flare gas varies over the lifetime of the flare. Traditional flow meters cannot successfully manage the changes in flare gas composition. 2

As seen in Table 1 (Flare 1), the molecular percentage of hydrogen changes from 86.18% to 48.77%, and methane changes from 5.93% to 3.52% over a year of operation. Faced with such changing flare gas composition, a typical total flow measurement error can be in the 5% to 10% range and could be as high as 20% in applications with widely varying compositions. Correcting measured linear velocities to actual mass flow rates can be problematic if the molecular weight of the waste gas varies by more than 20% from the molecular weight of the meter s calibration gas. Flare Gas Composition Variability: Flare 1 COMPONENT MOLE % MOLE % hydrogen 86.18 48.77 methane 5.93 3.52 ethane 0.81 0.26 ethylene 0.02 0.01 propane 0.34 0.14 propylene 0.00 0.01 n-butane 0.11 0.05 i-butane 0.11 0.06 cis, 2-butylene 0.16 0.06 trans, 2-butylene 0.17 0.06 isobutylene 0.12 ND 1,3-butadiene ND ND n-pentane 0.03 0.08 i-pentane 0.05 0.05 pentenes ND ND C 6 + 0.01 0.01 CO 0.02 0.04 N 2 4.99 45.80 0 2 ND ND CO 2 0.06 0.04 hydrogen sulfide 0.24 0.35 water vapor 0.68 0.70 Totals 100.00 100.00 Table 1. Examples of Flare Waste Gas Compositions Constituents of Interest and Variability over 1 Year 4 3

Many Meter Choices Few Good Solutions Over the last five years, multi-path transit-time ultrasonic meters (typically four-path) have been used for flare gas measurement. Given the flare gas measurement challenges they face, multi-path ultrasonic flow meters perform reasonably well. With multi-path ultrasonic flow meters, speed of sound through the flare gas is directly related to its density. This makes flare gas measurement independent of changing gas composition and facilitates mass flow measurement. Because the sensors are non-intrusive (not exposed directly to the flare gas), they have been used in some installations to measure dirty, wet gas without gumming up mechanical parts, resulting in lower maintenance costs. However, in some applications, dirt, wax, tar, and paraffin in the flow causes internal erosion or build-up of material on the inner wall of the pipe. Since multi-path ultrasonic meters are built into in-line pipe sections, called spool pieces, the entire meter must be removed to clean them. This degrades the flow measurement accuracy without obvious indicators. Susceptibility to the effects of flow profile, especially swirl, will also cause degraded accuracy. Multi-path ultrasonic meters are distinguished by the number of paths they use to compute the flow rate. Multiple paths enable more precise calculation of the gas velocity and the speed of sound (and thus density), but each set of paths substantially increases the cost. Cost also increases with the size of the spool piece. This can cost oil and gas companies over $15,0005 for a four-path ultrasonic flow meter. This cost is several times more than the traditional flow meters (depending on the technology) listed in Table 2 (next page). Other technologies listed in Table 2, like averaging pitot tubes and insertion turbine meters, have performance for measuring flare gas. These devices measure volumetric flow, not mass flow, which is the desired measurement. They require a clean flare gas with constant gas composition. Additionally, multivariable mass vortex meters successfully measure low pressures of flare gas, but they need to know the gas composition for accurate measurement. 4

Comparison of Flow Technologies Based on Performance Factors HIGH & LOW FLOW (TURNDOWN) LOW PRESSURE DIRTY FLARES VARYING COMPOSITION FLOW PROFILES COST Averaging Pitot Tubes $2,000 10 to 1 P device Prone to clog Volumetric Averages across pipe Insertion Turbines $1,000 10 to 1 Minimum velocity Prone to clog Volumetric Point measurement Insertion Vortex $3,000 Minimum velocity Multivariable Sensor head can plug, but is ly large Must know gas composition Point measurement Insertion Thermal $2,500 1,000 to 1 Must be calibrated at operating pressure Clean flares only Must know gas composition Point measurement Ultrasonic excellent excellent $15,000 100 to 1 Not affected External to pipe Infers density from speed of sound Signal accross pipe QuadraTherm excellent excellent $3,000 2,000 to 1 Multivariable Sensor head can plug, but is ly open Four compositions on board, any other can be uploaded in field Point measurement, but Reynolds number correction built in Table 2. Comparison of Flow Technologies Considered for Flare Gas Metering 5

Four-Sensor Thermal Mass Flow Meters Traditional thermal flow meters have limitations in flare gas measurement because they can t accurately measure changing gas composition without factory recalibration. Recent innovations in thermal mass flow sensor technology have removed this barrier to market entry. Four-sensor thermal mass flow meters now have the ability to adjust for changing flare gas compositions in the field over time. This new four-sensor thermal meter gives end-users a lower cost alternative to four-path ultrasonic meters in flare applications. Improved Accuracy Specification With four-sensor thermal sensor technology, as seen in Figure 1, accuracy specifications are comparable to four-path ultrasonic meters at a much more economical price. Pioneered by Sierra Instruments, Inc., in Monterey, California, four-sensor thermal has +/- 0.75% of reading accuracy for insertionprobe versions (far better than the 2.0% of reading previously possible with traditional thermal). The in-line version of the instrument improves on that with +/- 0.5% of reading accuracy. Figure 1. QuadraTherm Four-Sensor Design by Sierra Field Composition Changes, Now Possible For the first time, four-sensor technology can compete with multi-path ultrasonic meters due to its ability to compute the mass flow rate of any gas composition. Hyper-fast microprocessors run flowmeasurement algorithms to compute the mass flow of any gas composition. The microprocessor takes the inputs from the four sensors and solves the First Law of Thermodynamics (Heat Energy In = Heat Energy Out) for each data point. 6

In thermal mass flow meters, the composition of the gas is required. Flare gas composition sampling depends on the wellhead and typically done once every three months. Once the flare gas composition is known, operators can create, name, store and upload new gas compositions to the four-sensor meter (See Figure 2). Accuracy is maintained without sending the meter back to the factory for costly recalibration. The meter itself stores four gas compositions. Operators can access the software s gas library, which is password protected to keep proprietary gas mixtures secure. This gas library contains all AGA compliant gas properties needed to make the algorithmic gas mass flow rate calculations. Figure 2. Smart Interface Portal QuadraTherm Embedded Gas Composition Management Tool Cost Savings It was clear from the comparison of flow technologies for flare gas metering in Table 2 that both thermal and ultrasonic are the preferred choices. At this point, it is a time to review costs and overall cost of ownership. Table 3 gives a five year cost of ownership example comparing a traditional 6.0 inch (150 mm) long two-sensor insertion-probe thermal mass meter inserted into a 4.0 inch (100 mm) flare header, with an inline 4 (100mm) four-path inline ultrasonic meter, and a 6 inch (150 mm) long four-sensor insertion-probe thermal mass meter inserted into a 4 (100 mm) flare header. The four-path ultrasonic meter averages $15,000 (Flow Research, Inc. 2008 Study), while the four-sensor thermal insertion-probe meter averages $3,000. Insertion-probe thermal meters also accommodate larger pipe applications up to 72 inches (2m) with a single 0.75 inch (19mm) insertion point. 7

Ultrasonic meters only have in-line flow body configurations, and the cost increases exponentially with pipe size and number of paths. Using the Table 3 data, let s assume that a typical customer has 150 flare gas measurement points. When the composition changes five times over the life of the wellhead, costs add up. Using four-path ultrasonic metering would cost $2,475,000, but the instrument would be unaffected by gas composition changes. In contrast, the four-sensor thermal meter would be much less expensive at $562,500, even though periodic field adjustments of the four-sensor thermal meter would be required. If you take a more macroeconomic view on the industry and make the reasonable estimate of 30,000 new flares per year that need measurement, annual ultrasonic metering costs are pushed to $495 million. Under these same assumptions, four-sensor thermal would cost much less at $112 million. These cost estimates support the need for alternative, lower cost metering choices for this tough application. In the absence of lower cost options, energy costs will increase over the long-term as high metering costs are pushed to the consumer in the form of higher prices. Flow Meter Cost-of-Ownership Comparison 6 inch (150 mm) TRADITIONAL 2-SENSOR THERMAL INSERTION-PROBE MASS FLOW METER 4 inch (100 mm) INLINE 4-PATH ULTRASONIC FLOW METER 6 inch (150 mm) 4-SENSOR THERMAL INSERTION-PROBE MASS FLOW METER Instrument Initial Cost $2,500.00 $15,000.00 $3,000.00 Installation $ 500.00 $ 1,500.00 2 $ 500.00 3 Calibration 1 $ 850.00 1 00.00 4 $ 50.00 5 Calibration 2 $ 850.00 00.00 $ 50.00 Calibration 3 $ 850.00 00.00 $ 50.00 Calibration 4 $ 850.00 00.00 $ 50.00 Calibration 5 $ 850.00 00.00 $ 50.00 Total $7,250.00 $16,500.00 $3,750.00 Table 3. Example of Five Year Cost-of-Ownership Comparison Between Traditional and Four-Sensor Thermal Mass Flow Meters Versus Multi-Path Ultrasonic Flow Meters Table 3 Notes: Assume a 4 inch (100mm) flare header and gas composition that has changed 5 times over 5 years where it was dramatic enough to warrant instrument adjustment. 1 Cost to remove instrument, ship back to factory, recalibrate to new gas composition, return and reinstall. Cost of process measurement downtime not calculated 2 Must shut process, cut pipe to install inline ultrasonic flow meters. Cost of process measurement downtime not calculated 3 Single 6 inch (19.1mm) insertion point, can be hot-tapped 4 No need for removal from pipe or adjustment 5 Assume cost of 30 minutes at $50 labor cost each time the instrument is adjusted for new gas composition via field software interface. 8

Summary and Conclusions: Oil and gas companies may potentially lose thousands of dollars a day if they are not in compliance with local, state and federal regulations. And flow metering costs will drive energy prices up as they are passed to the consumer at the gas pump. In addition, as infrastructure is developed, gas that is now flared will eventually be sold to the national distribution network, turning a current liability into a future asset. While multi-path ultrasonic flow meters are widely used today, end-users now have an alternative. Primarily due to the significantly lower cost of ownership, four-sensor thermal mass flow technology is poised to become a highly attractive alternative. The ability to adjust the instrument in the field in response to changing flare gas compositions over time and the extremely high accuracy of these devices offer oil and gas companies a compelling alternative to multi-path ultrasonic meters. Acnowledgements Scott Rouse, Erica Giannini References 1. http://www.ogj.com/articles/2011/09/wea-new-epa-rules-would-divert-development-dollars-tocompliance.html 2. http://www.worldenergyoutlook.org/publications/weo-2012/ 3. World Bank: Global Forum on Flaring and Gas Utilization. December 13, 2006. 4. TCEQ work Assignment 5: Flare Waste Gas Flow Rate and Composition Measurement Methodologies Evaluation. Shell Global Solutions 2003. 5. Flow Reaserch Inc.: The World Market for Ultrasonic Flowmeters, 3rd Addition. January 2008. 6. EPA Enforcement Alert: Volume 10, Number 5. August 2012 Figure 3. 4-Sensor Insertion-Probe QuadraTherm Mass Flow Meter by Sierra 9