TurboDraft. Fire Eductor Operating Instructions.

Similar documents
TurboDraft Fire Eductor

Cozumel Turbodraft. Operational Considerations

Apparatus Operator/Pumper

Apparatus Operator Refresher Training Program

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Chapter 14 Water Shuttle Operations

Driver Operator Pumps: Basic Pump Operations

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Flow Material Length. Weight GPM LPM. Style 3095

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

USER GUIDE EMERGENCY PUMP KIT ULTRAFILTRATION ULTRAFILTRATION SYSTEMS. safe drinking water ULTRAFILTRATION UNIT FOR USE WITH:

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Bermad Pressure Reducing. Model: 42T

Operating Instructions Model and Hydrostatic Test Pump

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Vacutrans Instructions

Operating Instructions Model and Hydrostatic Test Pump

Essentials of Fire Fighting

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

MEGR-1627 Instruction Manual

Model: 43T. Bermad Pressure Relief Valve

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Des Plaines Fire Dept. Engineer Program

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

Model 420-HY Pressure Regulating Hydrant Valve

Operating Instructions Models and Hydrostatic Test Pumps

TECHNICAL DATA Q= C. Table 1 - Specifications

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

SKYBOX USER GUIDE EMERGENCY ULTRAFILTRATION PACKAGE. The trusted choice for rapid response potable water solu4ons SKYBOX

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

OPERATION MANUAL NTF-60 Plus

Advanced Fluid Handling Cart Owner s Manual

OPERATION MANUAL NTF-15

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

KILGORE FIRE DEPARTMENT

VRS Assembly & Operating Instructions

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. than the water inlet pressure to the concentrate

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Installation of Your SprayMaster System

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

MEGR-1912 Instruction Manual

PRO SINK -R 1 and 2. Dilution system CONTENTS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Hydrostatic Pressure Testing

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

KJ4000 Operating Instructions & Parts Manual NSN

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

FIREFIGHTING EQUIPMENT

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

TECHNICAL DATA. Trimpac 244a. September 16, 2013

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Operating Procedure TITON SUBSEA BOLT TENSIONER

Operating Instructions Models and Hydrostatic Test Pumps

Driver Releasal Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

2.0 INSTALLATION & SERVICE

Discharge Relief Valve Operation & Maint.

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Bermad Model:

OWNER S TECHNICAL MANUAL

TECHNICAL DATA. Page 1 of 12

FSRS Relative Point Value Guide

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q= Cv S

Accu-Tab PowerBase 3012AT by Axiall Corporation

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Operation & Service Manual

Essentials of Fire Fighting 6 th Edition Firefighter I

Geotech 1.66 Reclaimer

Model PSI Compressor with 3-Gallon Air Tank 12VDC

ELKHART BRASS MANUFACTURING COMPANY

Halsey Taylor Owners Manual STOP!

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Transcription:

TurboDraft Fire Eductor Operating Instructions

1234djfkjldfjlkdjfklsdjlkjfdslkjfsd

Table of Contents Description Page Introduction........ 1 Safety Guidelines... 2 Care and Maintenance... 3 TurboDraft Set-Up... 4-6 Tandem TurboDraft Operations... 7 Strainer Clearing... 8 Operating Tips... 9-10 Unit Testing... 11 Using the Distant Water Source Table... 12 Unit Specifications... 13 2-1/2 TurboDraft... 14 Notes (Intentionally Blank)... 15-20

Fire Eductors For many years Schutte & Koerting has provided portable eductors to the U.S. Navy. These eductors were used for fire fighting onboard ships. The units were used to increase the volume of water available for fire fighting. They utilized the high pressure pumps onboard to supply the motive flow to the eductor which was placed overboard. The design of the unit was for high discharge head and typically had a two-to-one flow ratio. (i.e. 100 gpm of motive, 200 gpm of suction, with total flow of 300 gpm.) Over the past several years, Schutte & Koerting has worked with several local fire fighters to develop an eductor designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner. Unfortunately, this is not the case. A large percentage of the fire companies outside large cities depend on lakes, ponds, streams, rivers, and even swimming pools as a water source during a fire. Water is currently accessed from these sources in two ways. The first choice is to maneuver the fire truck close (typically 30 feet or less) to the water source and use the onboard pump to draft. This produces the greatest water flow. In many cases, this is not possible due to weather or access restrictions. The second option is to carry a large portable pump to the water source and use this to draft the water and discharge it back to a pumper truck or portable tank close to and accessible to the fire trucks. Portable pumps large enough to supply sufficient water flows tend to be large and require routine maintenance. Schutte & Koerting has developed an eductor to utilize the third option for water supply. Our eductor utilizes the water stored onboard the fire truck as the motive flow to start the eductor flow and return the motive flow as well as the suction flow back to the fire truck. This allows the fire truck to be at least 150 feet away from the water and still achieve significant net water flow to be utilized for fire fighting. To put the unit in operation, a 2 1 2 inch hose line and a 5 inch LDH supply line are stretched from the fire truck with the eductor to the water supply. The eductor is placed in the water and the motive line is charged to 150 psig. This immediately starts the flow of water back to the fire truck through the 5 inch LDH supply line. Once the suction flow is established, the first portion of the flow is used to replenish the tank water in the truck. Once the tank has been replenished, the water supply has been established and water can be supplied for use on the fire. The unit was designed for 17.5 feet of head and during our prototype testing we were able to achieve 750 gpm net suction gain. We supplied 200 gpm at 150 psig to the eductor, 750 gpm was developed as a suction flow with a total flow back to the fire truck of 950 gpm. 200 gpm of the 950 gpm was being recycled back to supply the eductor. Testing was completed in the Spring of 2000 and marketing began in early Autumn of that same year. 1

Safety Guidelines 1. Carefully read and follow all operating instructions before putting the TurboDraft unit into service. 2. Be sure all pump operators are properly trained in the correct and safe use of the fire pump that is supplying the TurboDraft unit. 3. Proper personal protective equipment should be utilized while operating any fire pump and while present at any emergency scene. 4. Be sure all hose connections are snug and secure. 5. Use caution at all times around any high pressure pump connections. 6. Always understand and follow all department rules, guideline and operating procedures. 2

Care and Maintenance The TurboDraft unit is manufactured from aluminum and stainless steel. Little maintenance is required to keep your TurboDraft unit in proper operating condition. 1. Before and after using the TurboDraft, carefully inspect the unit for any damage to the body, tail, and fire connections. 2. After use, flush the unit with clean water to remove any mud, sand or debris from the inside and outside surfaces. Be sure to thoroughly flush the 2 1 2 inch connection, as any sand or grit will effect the swivel action. Also, inspect that the screen is free from any obstructions (grass, leaves, etc.). Mild soap and a soft brush should remove any dried mud or soils from the unit. 3. IMPORTANT - Inspect nozzle orifice to be sure there are no obstructions. Any restrictions within the nozzle will dramatically effect the performance of the TurboDraft unit. 4. Safely store the unit securely on or in the apparatus to avoid injury to personnel and damage to the TurboDraft. 3

TurboDraft Setup/Operation The unit requires a 2 1 2 inch discharge line from the fire truck and a 5 inch supply line to return water flow to the fire pump. The lines should be stretched from the truck to the water s edge avoiding sharp bends and kinks. Before connecting hoses to the TurboDraft, inspect the unit to be sure no debris has entered the inlet or discharge openings. Connect the 2 1 2 inch line to a discharge from the pump and to the TurboDraft unit, as shown below. Connect a 5 inch LDH supply line to pump intake valve and TurboDraft unit, as shown below. Care should be taken to insure all connections are tight and secure. A rope or webbing may be attached to the handle and secured, however, this is not critical because the unit may be retrieved using the hose lines. Submerge in 2 to 3 feet of standing water, with the screen/strainer facing up, 1 to 1 1 2 feet of moving water. After the above steps are complete the unit is ready to be put into operation. 4

TurboDraft Set-Up/Operation Engine should be placed into pump gear and truck prepared for pumping operations. The intake valve should be closed. Open the bleeder on the suction intake valve to allow any air in the hose to be vented. Open the tank-to-pump valve. Increase the engine pressure to 175 PSIG. Open the 2 1 2 inch discharge supplying the TurboDraft unit and maintain discharge pressure at 175 PSIG. This is required to start suction flow back to the truck. As the 2 1 2 inch line is charged, the 5 inch line will immediately start to fill. Close the bleeder once water reaches it and slowly open the suction intake valve. The water supply is now established. 5

Close the tank-to-pump valve. TurboDraft Set-Up/Operation At this point the truck s tank should be refilled. Open the tank fill valve 1 4 to 1 2 open and allow tank to fill. The truck tank should always be kept full to allow the water supply to be re-established, if necessary. With 100 ft. of 5 inch hose, it should take approximately 100-250 gallons of water to establish a water supply to the truck. Once tank is full, close tank fill valve. Slowly open required discharge valve(s). Maintain the required pressure (see Chart 1, page 12) on the TurboDraft 2 1 2 inch line at all times. During the use of the TurboDraft unit, care should be taken not to exceed supply source availability. This will cause the supply line from unit to collapse. (see Flow Chart 1 on page 12). Supply line (5 inch LDH) from the unit should always be monitored. Maximum flow from the TurboDraft unit is achieved when the supply line starts to become soft. If the supply line flow is exceeded and the line collapses, simply open the tankto-pump valve and decrease the discharge flow until the supply line recovers. Once stabilized, close the tank-to-pump valve and top off the tank as soon as possible. 2-1/2" 5" PORTA-TANK ± 100' TURBODRAFT STATIC WATER SOURCE 6

Tandem TurboDraft Operations * Minimum required pump size: 500 GPM Set up Operation: Set up and establish the first TurboDraft unit as discussed under TurboDraft Set-Up/Operation on pages 4-6. Refill the tank.* Lay out the second unit connecting its 2 1 2 inch charge line to a 2 1 2 inch outlet and its 5 inch supply line to the truck s officer side steamer connection.** Using the first TurboDraft as a supply, charge the second unit s 2 1 2 inch supply line. Once the second unit s 5 inch line has been bled free of air, slowly open its suction valve. Begin water supply operations by slowly opening the required discharge valves. * The unit with the longest 5 inch line should be set up first and connected to the driver side steamer/intake. ** The second steamer must be fitted with a suction valve and air bleeder. A front or rear suction may be used in lieu of the other steamer if a suction of hard sleeve is installed between the 5 inch hose and the suction connection. This is necessary to prevent premature collapse of this line. 7

Strainer Clearing During operation of the unit it may become necessary to clear the strainer of grass or debris from the water source. This is easily performed and should only take 15 to 30 seconds. Discontinue water supply operations by closing down all discharges from the truck except for the line supplying the TurboDraft unit. Open the tank-to-pump valve. Slowly close the suction intake valve. This will cause the flow of water to backup into the strainer and clear any obstructions from the screen. Keep valve closed for 15 to 30 seconds to ensure the debris is cleared from the strainer area. 2.5 DISCHARGE LINE 5 SUPPLY LINE DISCHARGE 5 STORTZ Slowly open the suction intake valve to re-establish the water supply. Close tank-to-pump valve and open tank fill valve 1 4 to 1 2 and refill tank. 2.5 NST CONNECTION MOTIVE (NOTE: UNIT IS SUBMERGED IN WATER SUPPLY) When tank is full, close tank fill valve and resume flow operations. FIGURE 1 SUCTION FLOW arrow indicates back flow to clear the screen 8

Operating Tips Maintain pump seals per manufacturer s recommendations and tightly close all valves and bleeders to prevent air leaks and loss of prime. Take care to keep discharge flow rates within TurboDraft s rated capacity (see Chart 1 on page 12). If you do not, the suction hose will collapse. NOTE Keep hose lays and lifts as short as possible. The shorter the hose and lift, the greater your flow. The supply line (or longest supply line if two units are being used) should be connected to the driver side pump panel. This allows the driver to feel and see the hose. The TurboDraft s maximum flow is achieved when the supply hose starts to become soft. If the supply hose does collapse, quickly open the tank-to-pump valve to reestablish flow. Then, reduce discharge flow to within units capability and top off tank. NOTE When operating near capacity or under fluctuating discharge conditions, be ready by keeping your hand on the tank-to-pump valve. If the TurboDraft cannot be adequately submerged, use tennis balls (or other floating object) or a booster line sprayed above its inlet to break the vortex and prevent air from getting into the pump (i.e., loss of prime). 9

Operating Tips Under heavy algae surface debris conditions, back flushing (shown on page 8) may not be sufficient to prevent clogging of the strainer. Use a booster or forestry line to keep as much algae away as possible. If you have a pressure governor, use it. This will help maintain the constant discharge pressure required to the unit. TurboDraft use should be regularly practiced and results confirmed individually as this may vary slightly between trucks and operators. The pump s rated capacity at 150 psi should exceed the expected flow rate (see Chart 1 on page 12) by 300 GPM. The TurboDraft unit cannot achieve maximum rated flows with pumpers having rated capacities of less than 1,000 GPM. 10

Unit Testing A simple test can be performed to determine the fire flow of a given water source. In addition to the TurboDraft setup, connect a master stream device with a straight bore nozzle. See page 12 to determine the estimated fire flow for your location and required nozzle bore for deck gun. Place the TurboDraft unit in operation as shown on pages 4 through 6. Once the water supply is established, start flowing water to the deck gun and continue to increase water flow to the deck gun until the 5 inch line from the TurboDraft starts to get soft. At this point you have reached the maximum flow. Read the pressure at the deck gun. Refer to Chart 3 below to determine the flow for the deck gun at that pressure. Chart 3 GPM At Various Pressures (PSIG) Nozz. Dia. 30 35 40 45 50 55 60 66 70 76 80 85 90 95 100 105 110 115 120 1 1 8 206 222 238 252 266 279 291 305 315 328 336 347 357 366 376 385 394 403 412 1 3 8 308 332 355 377 397 417 435 456 470 490 502 518 533 547 562 575 589 602 615 1 1 2 366 395 423 448 473 496 518 543 559 583 598 616 634 651 668 685 701 717 732 11

Chart 1 Using The Distant Water Source Table Length of 5 Hose 50 100 150 200 Lift Pump Discharge Pressure Max. Avail. Fire Flow 10 175 psig 670 GPM 20 175 psig 470 GPM 10 180 psig 570 GPM 20 180 psig 400 GPM 10 185 psig 480 GPM 20 185 psig 325 GPM 10 190 psig 440 GPM 20 190 psig 280 GPM 1. Determine the required hose length (use the longer of the two if two TurboDraft units will be used). Refer to Chart 2 below for friction loss in hose line. 2. Estimate or measure the required lift. This is best done by pre-planning water source and actual measurement is preferred, as lifts can be visually deceiving. Hint: Place a pressure gauge on the end of a hose line. Place the gauge at water s edge and the opposite end of hose at truck elevation. Fill hose with water leaving the truck end open to atmosphere. The lift can be estimated by multiplying the pressure gauge reading (psi) by 2.3. 3. Read across and determine the required discharge pressure for the TurboDraft s 2 1 2 inch line and the maximum available fire flow. Chart 2 Friction Loss / 100 Ft. Of 5 Hose GPM 400 500 600 700 800 900 1000 1200 PSI 1.1 1.7 2.4 3.3 4.2 5.3 6.5 9.3 12

Specifications 2 16 8 11 7 12 5 4 9 9 17 13 14 2 4 1/2 10 8 9/16 11 7/8 3 11 3/16 24 5/8 38 3/4 5 11/16 12 5/16 MK NO DESCRIPTION QTY MATERIAL REMARKS 01 FIRE EDUCTOR ASSY. 1 ALUMINUM 02 BODY 1 ALUMINUM 99EB123J002 03 NOZZLE 1 ALUMINUM 131J0113J001 04 TAIL 1 ALUMINUM 98GB137J002 05 INLET PIPE 1 ALUMINUM 0010166J001 06 FILTER SCREEN 1 SST TY 304 0010115J001 07 BOLTING PLATE 2 ALUMINUM 0410098J001 08 HEX HEAD CAP SCREW 8 18-8 SST 0510220J001 09 5 FIRE HOSE ADAPTER 1 ALUMINUM 001B201J001 10 2-1/2 FIRE HOSE ADAPTER 1 ALUMINUM 98S0360J001 11 RIVET 8 SST TY 303 TD500-RIVET 12 HEX HEAD CAP SCREW 2 18-8 SST AAA29D22132 13 NAME PLATE 1 ALUMINUM 0010196J001 14 DRIVE SCREWS 4 0-1/8, 18-8 SST 0010197J001 15 I.O. & M. MANUAL 1 0010244J001 16 EYEBOLT WITH LOCKNUT 1 SS 5/8 8 5/16 091J0228001 091J0229001 17 HANDLE 1 SST A351 CF8M 0110195J001 Distant Water Source Situation 1,2,3 Length of 5 Hose 50 100 150 200 Lift Pump Discharge Pressure Max. Avail. Fire Flow 1,2 10 175 psig 670 GPM 20 175 psig 470 GPM 10 180 psig 570 GPM 20 180 psig 400 GPM 10 185 psig 480 GPM 20 185 psig 325 GPM 10 190 psig 440 GPM 20 190 psig 280 GPM Note: Using 6 supply line can increase unit output by decreasing line friction losses. 1 Theoretical, based on test curves of 9/21/99 and hose friction loss per NFPA Fire Protection Handbook, 15th Edition, Table 17-7H, actual friction losses may vary depending upon hose and coupling design/manufacturer. 2 All flows achievable with 1,000 GPM rated pumper based on NFPA recommended pump curves. Use larger pumper where maintenance/performance is questionable. 3 Minimum available flow from water source recognized by ISO for grading purposes is 250 GPM. ISO does not recognize drafting sources requiring a lift in excess of 18 (This is not a drafting device as it operates under pressure.) Net weight of unit: 48.5 lbs. 13

TurboDraft Operation 2-1/2 TurboDraft Once the TurboDraft Fire Eductor has been set up it can be quickly placed into service. The steamer suction valve is left closed and its air bleeder is opened. The 1 1 2 inch line is charged to approximately 175 psig. The force of the flow combined with TurboDraft eductor technology creates a suction which draws water from the standing water supply. As this happens, the return line is charged back to the fire truck. Once the air is bled from the supply line, the bleeder is closed and the steamer valve is opened. At this point the water supply has been established. 60 GPM is re-circulated through the truck to maintain a continuous flow and 264 GPM is available to supply tanker trucks or fill portable tanks. Useable fire flow will vary based on elevation and hose friction loss. (See table below.) Tap Water Sources in Remote Locations Rural fire companies need creative solutions to utilize water sources that are not accessible using typical drafting techniques. Schutte & Koerting s TurboDraft Fire Eductor allows fire companies to tap into water supplies like ponds, streams, and swimming pools up to 250 away and can generate flows up to 264 GPM. Overall Length: 30 Weight: 20 lbs. Connections: 1 1 2 NST Female Inlet 2 1 2 NST Male Outlet Discharge Head (ft) 30 20 10 180 PSIG Supply Pressu 165 PSIG Supply Pressu 150 PSIG Supply Pressu 2 1/2 TurboDraft Fire Eductor Performance 0 50 100 150 200 250 300 Net Suction Flow (GPM) Supply flow is 60 gpm psig truck pressure Distant Water Source Situation for 2 1 2 Unit Length of 2 1 2 Hose 50 100 150 200 Lift Pump Discharge Pressure Max. Avail. Fire Flow 10 175 psig 264 GPM 20 175 psig 185 GPM 10 180 psig 224 GPM 20 180 psig 157 GPM 10 185 psig 189 GPM 20 185 psig 128 GPM 10 190 psig 173 GPM 20 190 psig 110 GPM 14

Notes 15

Notes 16

Notes 17

Notes 18

Notes 19

Notes 20

030314