Circuit diagnosis. Plan of attack Testing techniques and analysis. Failures causes and patterns

Similar documents
Steven Bellamy and Ronnie Jones Raleigh Durham International Airport

Universal Valve Company Inc

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Universal Valve Company Inc

KOBOLD KSM FLOWMETER. User Instructions

Size Selection & Installation of QSZH-125

Polatrak ROV II - Tip Contact Probe Operation Manual

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

Inspection and Testing Pocket Notes

Ground Fault Circuit Interrupter(GFCI) Policy

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

*ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE)

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

Some Furnace Questions I received an from a podcast listener with some furnace related questions. Based on the nature of the questions I figured

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Chapter 5: Comparison of Inspection and Testing Results

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

ELECTRIC OPERATING PROCEDURES Date: 11/01/06

Manual Leveling Control Installation/Operation

200 PSI COMPRESSORS - MODEL NUMBERS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

IMPORTANT SAFETY INSTRUCTIONS

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors

SEGMENT NINE - Electricity

SEMEMI SQA Unit Code H2AP 04 Carrying out fault location on electrical equipment and circuits

Sunbrite LTC Large Underwater Pool Lights

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

100C Air Compressor Kit

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs

OEM Manual. MODEL ½ Digit DRUM SCALE

Cycling Device Training Manual

Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS

Instructions for Installing and Operating Clark Reliance EA101 Series Levalarm

LOCK-OUT/TAG-OUT (LO/TO) SAFETY PROGRAM

Lockout / Tag out Program

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

MODELS (2 foot Version) (4 foot Version)

Maintaining electrical equipment/systems

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

Aquavar SOLO 2 Frequently Asked Questions

EcoCell Vertical Electrophoresis Unit

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

T EK-SUB 4800C 19 mm Submersible Level Transmitter

EXTERNALLY ROUTED DROPPER POST owner S MANUAL

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Norrsken Family Booklet

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Deep Well Submersible Pump Model MSU/MSUS

RPS900W Redundant Power Supply. Installation Guide.

A U T O O P E N S E R I E S C A P P R E S S O P E R A T O R S M A N U A L

Bollard Light Installation Guidelines

DEEPSEA. Sealite Sphere 6500 POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

Accu-Tab Systems 1000 Series by Axiall Corporation

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

PARAVION TECHNOLOGY, INC AIRWAY AVENUE FT. COLLINS, COLORADO 80524

POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS > AXIOM 3.5L, PASSPORT, RODEO & RODEO SPORT 3.2L

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

Easy Nest Kits. Installation Suggestions

Are Detonator Qualification and Lot Acceptance Test Requirements Rational?

Heavy-Duty Hot Knife

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

OWNER'S MANUAL FISHING AND PONTOON BOAT ANCHOR WINCH. 24' Class Rope Anchor Winch

Gas Network Craftsperson

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

INSTRUCTION MANUAL. Gas Salamander

D I G I T A L C L A M

ES18 Security Theory/Regulations Answer Schedule

Welding With Arc Welding Equipment

PRODUCT SPECIFICATION

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

REFERENCE SPECIFICATION

MODEL WEIGH MODULE

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Service Instructions. Syntron Control Model: CSCR-1-B (115V)

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS

SERVICE & MAINTENANCE MANUAL FOR:

General maintenance engineering applications

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

icreasepro Creaser Operators Manual

RAM 4021 Operation Manual

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

SEMEM3-65 Servicing anaesthetic and ventilation equipment

Transcription:

Circuit diagnosis Plan of attack Testing techniques and analysis Verification Failures causes and patterns

Circuit Diagnosis - Plan of attack In general the process of diagnosis is abut keeping facts and assumptions organized. Never mistake the two.

Circuit Diagnosis - Plan of attack Always use a plan. Always record results. Intermittent failures often a long take time to identify. Always verify and re-verify.

Circuit Diagnosis - Plan of attack A plan should start with verifying the problem, if possible. In general the plan should isolate through process of elimination. The plan should prioritize based upon ease of testing and likelihood of failure. Always find out what was done most recently.

Circuit Diagnosis - Plan of attack Often times known good data is hard to acquire. This can come from schematics, This can come from schematics, troubleshooting charts, other maintenance manuals, or other known good systems.

Circuit Diagnosis - Plan of attack This data can be various readings like voltages, resistances, or it can be O- Scope patterns, or data codes. But, effective diagnosis will not happen without good data.

Circuit Diagnosis - Plan of attack Use various connectors, switches, or circuit breakers to isolate circuits or portions of circuits.

Circuit Diagnosis - Plan of attack If a part proves bad, determine why if failed if possible. Parts that smelled burnt often fail due to too much load for some other reason. Avoid parts swapping unless its a last resort, this can get very expensive.

Circuit Diagnosis - Plan of attack Always assume multiple problems, particularly if you are not the first one looking at it. Be particularly alert if you see evidence of new parts currently installed. If there are multiple symptoms look to see what is common between symptom areas.

Circuit Diagnosis - Plan of attack Don t always trust manufacturer s data. Things like wire color or numbers sometimes get changed without being documented. Is very uncommon, so don t readily assume this, but if it happens, it ll drive you nuts.

Circuit Diagnosis - Testing techniques and analysis Testing technique is also critical. Make sure you are testing what you think you are. Trying to read power source voltage from a ground won t tell you much. Or reading resistance with an unseen parallel path will nullify any results.

Circuit Diagnosis - Testing techniques and analysis Be careful how you hook up test equipment. A current test applied incorrectly can fry a lot of pricy stuff. Make sure the circuit status is correct prior ro hook up, circuit off/circuit on/circuit devices running. Don t use an Ohm or Amp meter for voltage tests.

Circuit Diagnosis - Testing techniques and analysis Try to test at connectors without compromising their sealing capacity. Penetrating insulation is bad at best, but if you must, reseal with a dab of electrician s silicone sealant. (Non-corrosive)

Circuit Diagnosis Verification Always verify testing repeatability under differing conditions. Low voltage coupled with a voltage drop check can ensure accuracy. Heated vs cooled testing is often done. Once repaired re-verify circuit operation completely.

Circuit Diagnosis Verification Check to be sure other circuits are also working. In fixing one thing you may have loosened a poor connection somewhere else. Be thorough, customer confidence is what pays the bills.

Circuit Diagnosis Verification Always be in hyper-alert if other attempts have been made to rectify this problem. Many are challenged electrically and will repair symptoms leaving the cause unrepaired. They may also add new complications to your diagnosis/repair efforts.

Circuit Diagnosis - Failures causes and patterns There are only three types of failures within any circuit. An Open A Short A failed electromotive source or a partial/combination of the above.

Circuit Diagnosis - Failures causes and patterns An open is when there is a break in portion of the circuit cause the electrons to stop flowing. A short is when the electrons are allowed to flow anywhere other than designed.

Circuit Diagnosis - Failures causes and patterns A failed source will depend upon the type of source. In a chemical source either the source In a chemical source either the source is internally shorted/open, or its chemically depleted.

Circuit Diagnosis - Failures causes and patterns In a magnetic source either there is an internal short/open, a loss of magnetism, a failed current converter/regulator, or the unit has mechanically failed.

Circuit Diagnosis - Failures causes and patterns Circuit boards Typically fail at solder joints. Traces get fried. If smoky there is a high current user that needs fixing. Onboard component repair is rare but doable if you know the circuit.

Circuit Diagnosis - Failures Connectors causes and patterns Most common cause of electrical failures. Pin misalignment, or pin push-back Bad pin crimping Full of H 2 O or corrosion

Circuit Diagnosis - Failures Idiots causes and patterns If you are replacing a new part look for the idiot who didn t diagnose the original problem, and don t join them. Black vinyl electrical tape is a good sign of needing idiot intervention. The stupid list is infinite!!!

Circuit repair Component replacement Soldering

Circuit repair Component replacement If at all possible know why a component failed before you replace it. In general internal component repair should be done at the depot level. Field level repair is usually component or inter-connection replacements.

Circuit repair - Soldering The correct, and good quality tools are mandatory, do not use cheap unregulated irons. Solder surfaces must be clean and kept that way. Use flux minimally, and remove thoroughly.

Circuit repair - Soldering Delicate components should have heat sink between heat source and part. Heat source is wetted with solder to conduct heat quickly. Parts are heated then solder is added. Prefluxing is helpful with un-tinned parts.

Circuit repair - Soldering Adequate heat is critical to avoid cold joints that crack after time. Solder cools too fast and pre-cracks due to shrinkage. Plan for insulation prior to soldering (pre-install heat shrink or other mounting devices as needed)

Circuit repair - Soldering Do not compromise heat sinks, reattach with proper hardware and bonding agents. Do not overheat trace (delaminate it from board) Do not create conductive bridges (joints should be concave but filled)