GAS DETECTION: CALIBRATION GAS

Similar documents
PRECISION GAS MIXTURES

Precision Calibration Gas

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Gas-Detection Instruments

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Gas-Detection Instruments

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Automatic Test and Calibration Station

Nonrefillable Cylinders

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Non-refillable canister solutions for ultimate portability

GASES FIRE & RESCUE SPECIALTY. Gases & Equipment. Medical Gases Liquid & High Pressure Oxygen U.S.P. Nitrogen N.F. Carbon Dioxide U.S.P.

Technical Manual. Sensepoint XCD Gas Detector

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Gas Mixture Two Components. Gas Mixtures Two Components

SAFETY FIRST. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES S.

Lecture Bottles Purchase & Disposal

Operation and Maintenance Manual

IRwin Methane Leak Detector. Innovation makes the difference

Phosgene Sensor. Sensoric COCl2 3E 1

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Misuse of Combustible Gas Meters

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MODEL CALIBRATION GAS DELIVERY SYSTEM

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

CSA Sample Draw Aspirator Adapter Operator s Manual

Sensepoint XCD. Calibration Guide

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions

ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS:

Describe Flammable Gas Measurement

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Introduction to Confined Space Safety OR-OSHA

GasLab SAN-102 Micro Oxygen Monitor User Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

STORAGE AND USE OF HIGH HAZARD GAS

Ozone. Sensoric O3 3E 1

Aerotest Breathing Air Systems

City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B

CYLINDER VALVE GUIDELINES TD 12/15/E

Recent changes in the rules for confined space entry

Leaders in Calibration Gas Solutions

Instrumental Technique GAS CYLINDER

SENSOR MANUAL Document No M (Revision L)

GasLab SAN-102 Micro Oxygen Monitor User Manual

Working in Gas Hazard Areas

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

Gas monitoring using GASMET FTIR

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Discovery HP-TGA 75/750. Site Preparation Guide

Vehicle and Engine Emissions Testing

800.Keen.Gas

CALIBRATION KIT. Instruction Manual

Technical Data for Alicat M-Series Mass Flow Meters sccm Full Scale through slpm Full Scale

Compressed Gas ER Fundamentals

Technical Data for Alicat MC and MCR Mass Flow Controllers sccm Full Scale through slpm Full Scale

Quebec Quebec Tel : Fax : MSDS: Hydrogen Sulfide in Nitrogen Mixture PRODUCT INFORMATION

Multiple Tube - Teflon PTFE-Glass Flowmeters

Guide to Gases and Vapours

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Flammability Chart. Gas Formula Ignition

Aerotest Breathing Air Systems

Single Tube Flowmeters

8.1 Calibration of gas sensors

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

BASF Corporation Title: Portable Multi-Gas Monitoring Equipment. Individual Unit Function: Safety Procedure No.: GSS09 Page: 1 of 5

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Oxygen Measurement Systems High Reliability and Wide Application Coverage

There is no protection without detection. HiQ specialty gases, equipment and services for environmental monitoring.

There is no protection without detection. HiQ Specialty Gases, Equipment and Services for Environmental Monitoring.

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above:

WHAT IS GAS TANK/CYLINDER?

Identifying Confined Space. By Jeff Lavery KC Supply Co

Operation and Maintenance Manual

Chapter 4: Monitoring and Sampling. Chapter 4: Monitoring and Sampling

CONFINED SPACE PROGRAM

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Multiple Tube Flowmeters

HiQ laboratory gas generators.

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

Use of Hazardous Gases Standard Operating Procedure

NEW Edge Series Products: OUTFITS and REGULATORS

The lighter range. Alumini mini-containers from Westfalen.

Technical Data for Alicat MS Series Mass Flow Meters

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck!

Operating Instructions

Contaminated Air in Cylinders By Ronny J. Coleman

Confined Space Entry Program 8 CCR 5157

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

Specification & scope of work for Multi Component Gas Separation test Rig

Transcription:

ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures 98 Reactive Single & Two-Gas Mixtures 98 Non-Reactive Multi Mixtures 99 Reactive Multi Mixtures 99 Bump Gas 100 BumpIt 100 Information Precision Gas Mixtures 100 Cylinder Information 101 EcoSmart Refillable Cylinders 102 Accessories Cases & Kits 103 Regulators 104 www.conceptcontrols.com 97

GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures Reactive Single & Two-Gas Mixtures PART NUMBER (SUFFIX) TARGET GAS CONCN. BALANCE -21-5 Benzene 5 ppm Air -50-200 Carbon Monoxide 200 ppm Air -50-100 Carbon Monoxide 100 ppm Air -50-50 Carbon Monoxide 50 ppm Air -50-35 Carbon Monoxide 35 ppm Air -50-250 Carbon Monoxide 250 ppm Air -35-2.5 Carbon Dioxide 2.5 % vol. Nitrogen -34-1000 Carbon Dioxide 1000 ppm Nitrogen -34-2000 Carbon Dioxide 2000 ppm Nitrogen -34-5000 Carbon Dioxide 5000 ppm Nitrogen -62A-50 Ethylene 50 ppm Air -289-400 Hexane 400 ppm Air -262-0.48 Hexane 0.48% vol. Air -85-2 Hydrogen 2% vol. Air -248-10 Isobutylene 10 ppm Air -248-100 Isobutylene 100 ppm Air -135A-2.5 Methane 50% LEL Air -135N Methane 50% vol. Nitrogen -135A-0.5 Methane 10% LEL Air *34LA-132 Methane 100% vol. n/a -114 Nitrogen 99.999% vol. n/a 154-0.75 Pentane.79% Vol. 50% LEL Air 154-.35 Pentane.35% Vol. 25% LEL Air 176-1.05 Propane 1.05% Vol. 50% LEL Air -1 Zero Air 20.9% vol. Nitrogen Non-Reactive Single and Two-Gas Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 17 Litre 17L 71 Series or 2007 DFR 34 Litre 34LS 71 Series or 2007 DFR 105 Litre 105L 70 Series or 2001 DFR PART NUMBER (SUFFIX) TARGET GAS CONCN. BALANCE -13-25 Ammonia 25 ppm Nitrogen -14-25 Ammonia 25 ppm Air -14-50 Ammonia 50 ppm Air -252-5 Chlorine 5 ppm Nitrogen -252-10 Chlorine 10 ppm Nitrogen -HCN-5 Hydrogen Cyanide 5 ppm Nitrogen -HCN-10 Hydrogen Cyanide 10 ppm Nitrogen -HCL-5 Hydrogen Chloride 5 ppm Nitrogen -HCL-10 Hydrogen Chloride 10 ppm Nitrogen -98-50 Hydrogen Sulfide 50 ppm Nitrogen -99-50 Hydrogen Sulfide 50 ppm Air -98-25 Hydrogen Sulfide 25 ppm Nitrogen -98-5 Hydrogen Sulfide 5 ppm Nitrogen -98-15 Hydrogen Sulfide 15 ppm Nitrogen -98-20 Hydrogen Sulfide 20 ppm Nitrogen -98-35 Hydrogen Sulfide 35 ppm Nitrogen -98-40 Hydrogen Sulfide 40 ppm Nitrogen -98-100 Hydrogen Sulfide 100 ppm Nitrogen -98-200 Hydrogen Sulfide 200 ppm Nitrogen -99-25 Hydrogen Sulfide 25 ppm Air -99-10 Hydrogen Sulfide 10 ppm Air -98-10 Hydrogen Sulfide 10 ppm Nitrogen -112-100 Nitrogen Dioxide 100 ppm Air -112-10 Nitrogen Dioxide 10 ppm Air -112-5 Nitrogen Dioxide 5 ppm Air -175-5 Sulfur Dioxide 5 ppm Nitrogen -175-10 Sulfur Dioxide 10 ppm Nitrogen -175-25 Sulfur Dioxide 25 ppm Nitrogen -175-50 Sulfur Dioxide 50 ppm Nitrogen -175-100 Sulfur Dioxide 100 ppm Nitrogen Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 34 Litre 34L 70 Series or 2001 DFR 58 Litre 58L 70 Series or 2001 DFR 74 Litre 74L 70 Series or 2001 DFR 116L 70 Series or 2001 DFR 98 www.conceptcontrols.com

GAS MIXTURES Non-Reactive Multi Mixtures PART NUMBER (SUFFIX) CARBON MONOXIDE METHANE PENTANE OXYGEN BALANCE COMPANY -304 100 ppm 50% LEL Air Draeger -305 100 ppm 30% LEL Air Draeger -309 200 ppm 50% LEL 19% Nitrogen Dynamation -311 35% LEL 25% LEL Nitrogen ISC -315 50 ppm 50% LEL 17% Nitrogen Quest -318 50 ppm 50% LEL 12% Nitrogen GasTech -321 100 ppm 50% LEL 17% Nitrogen -325 35 ppm 10% LEL 18% Nitrogen -328 100 ppm 50% LEL 15% Nitrogen -348 100 ppm 50% LEL 12% Nitrogen Reactive Multi Mixtures PART NUMBER METHANE PENTANE PROPANE CARBON MONOXIDE HYDROGEN SULFIDE OXYGEN BALANCE COMPANY -404 50% LEL 100 ppm 25 ppm 20.9% Nitrogen BW -409 50% LEL 50 ppm 25 ppm 12% Nitrogen GasTech / RKI -421 50% LEL 100 ppm 25 ppm 18% Nitrogen BW (dock. stn.) -463 50% LEL 100 ppm 25 ppm 19% Nitrogen ISC -406 50% LEL 50 ppm 25 ppm 18% Nitrogen Bio-Systems -412 50% LEL 50 ppm 25 ppm 20.9% Nitrogen RAE Systems -413 50% LEL 50 ppm 10 ppm 20.9% Nitrogen RAE Systems -414 58% LEL 300 ppm 10 ppm 15% Nitrogen MSA -418 50% LEL 50 ppm 25 ppm 19% Nitrogen -410 25% LEL 25 ppm 19% Nitrogen ISC -411 25% LEL 100 ppm 25 ppm 19% Nitrogen ISC -425 10% LEL 35 ppm 10 ppm 18% Nitrogen AIM -445 25% LEL 50 ppm 25 ppm 12% Nitrogen GasTech (Pent.) -453 50% LEL 50 ppm 25 ppm 12% Nitrogen GasTech (Pent.) -471 50% LEL 100 ppm 25 ppm 18% Nitrogen BW (Pentane) -480 50% LEL 100 ppm 25 ppm 20.9% Nitrogen BW (Pentane) -403E 50% LEL 50 ppm 25 ppm 18% Nitrogen Bio-Systems -470 50% LEL 100 ppm 25 ppm 20.9% Nitrogen Non-Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 17 Litre 17L 71 Series or 2007 DFR 34 Litre 34LS 71 Series or 2007 DFR 105 Litre 105L 70 Series or 2001 DFR Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 34 Litre 34L 70 Series or 2001 DFR 58 Litre 58L 70 Series or 2001 DFR 74 Litre 74L 70 Series or 2001 DFR 116L 70 Series or 2001 DFR www.conceptcontrols.com 99

GAS DETECTION: CALIBRATION GAS Bump Gas PART NO. CH4 CO H2S O2 BAL. 10L-490-T 50% LEL 200 ppm 40 ppm 10% Nitrogen 10L-467 50% LEL 100 ppm 60 ppm 13% 10L-135 50% LEL Air 98-50 50 ppm Nitrogen BumpIt Make sure your gas detector works! BumpIt is a disposable 6 mini gas cylinder designed for bump testing portable gas monitors, gas sensors, or fixed gas detection equipment. Non-aerosol, non-flammable and low pressure 10-15 five second bumps per cylinder No regulator needed Many mixes available: Call for available gases Information Precision Gas Mixtures SIZE GAS BALANCE SHELF LIFE 17 & 34 Litre Non-Reactive Air or Nitrogen 48 Months 105 Litre Non-Reactive Air or Nitrogen 48 Months 221 Litre Non-Reactive Air or Nitrogen 48 Months 552 Litre Non-Reactive Air or Nitrogen 48 Months Sulfur Dioxide Air or Nitrogen 15 Months Hydrogen Sulfide Air or Nitrogen 15 Months The Importance of Bump Testing Gas monitoring instruments are designed to protect personnel from unseen hazards that may exist in workplace environments, including confined spaces. It is vital to worker safety that these instruments are maintained and calibrated properly. Instrument inaccuracy due to improper or irregular calibration can lead to serious accidents. Exposure to excessive levels of toxic gas or an oxygen-deficient environment can cause workers serious illness and even death. Combustible gas explosions are often catastrophic, injuring or killing personnel and destroying property. The only way to guarantee that an instrument will detect gas accurately and reliably is to test it with a known concentration of gas. Exposing the instrument to a known concentration of test gas will show whether the sensors respond accurately and whether the instrument alarms function properly. DEFINITION: QUICK CHECK The brief exposure of the monitor to gas at concentrations higher than those of the low-alarm set-points to test the functionality of the monitor. Ammonia Air or Nitrogen 12 Months Hydrogen Cyanide Nitrogen 12 Months Chlorine Nitrogen 12 Months Hydrogen Chloride Nitrogen 12 Months Nitrogen Oxide Nitrogen 12 Months Nitrogen Dioxide Air 12 Months Phosphine Nitrogen 12 Months Silane Nitrogen 12 Months Ethylene Oxide Nitrogen 12 Months Four-Gas Mix Air or Nitrogen 15 Months DEFINITION: BUMP TEST The brief exposure of the monitor to a known concentration of gas (exceeding the low-alarm set-point) for each sensor. The instrument reading is then compared against the reference point of the last calibration and if it is within an acceptable range (normally 10%) its calibration can be considered accurate. 10 Litre Hydrogen Sulfide Air or Nitrogen 6 Months DEFINITION: CALIBRATION Calibration refers to an instrument s measuring accuracy relative to a known concentration of gas. Gas detectors measure the concentration of a gas in an air sample by comparing the sensor s response to the response generated by a calibration gas of a known concentration. The instrument s response to the calibration gas serves as the measurement scale or reference point. 100 www.conceptcontrols.com

INFORMATION Cylinder Information CYLINDER CONTENTS DIMENSIONS MATERIAL WATER CAPACITY WEIGHT VALVE INLET TRANSPORT REGULATOR REQUIRED 552L 552 litres (19.4 cu ft) @70 F & 2200 20.75 x 4.5 Steel 3.69 Litres 11 lbs. Gas Specific N/A 221L 221 litres (8.0 cu ft) @70 F & 250 16.25 x 9.0 Steel 12 Litres 6.3 lbs. CGA 165 70-series w/ adapter 116L 116 litres (4.0 cu ft) @70 F & 1000 14.25 x 3.5 Aluminum 1.72 Litres 2.1 lbs. 5/8-18 105L 105 litres (3.6 cu ft) @70 F & 1000 13.6 x 3.3 Steel 1.52 Litres 3 lbs. 5/8-18 74L 74 litres (2.6 cu ft) @70 F & 500 14.25 x 4.25 Aluminum 2.2 Litres 2.3 lbs. 5/8-18 58L 58 litres (2.0 cu ft) @70 F & 500 14.25 x 3.5 Aluminum 1.72 Litres 1.75 lbs. 5/8-18 34L 34 litres (1.2 cu ft) @70 F & 500 10.64 x 3.125 Aluminum 0.9 Litres 1.9 lbs. 5/8-18 34LS 34 litres (1.2 cu ft) @70 F & 500 10.75 x 2.9 Steel 0.9 Litres 1.5 lbs. CGA 600 71-series 71 CVA 17L 17 litres (0.6 cu ft) @70 F & 240 10.75 x 2.9 Steel 1 Litre 1 lb. CGA 600 71-series 71 CVA 10L 10 litres (0.35 cu ft) @70 F & 500 9.4 x 2.9 Aluminum 0.97 Litres 0.3 lbs 7/16 28NS/2 male Spray Nozzle www.conceptcontrols.com 101

GAS DETECTION: CALIBRATION GAS EcoSmart Refillable Cylinders NEW Concept Controls and Gasco are taking responsibility for the impact our products have on the environment. Exclusive EcoSmart cylinders are coupled with innovative measures which enable you to reuse and refill your gas cylinder. Gasco employs proprietary procedures to create the highest quality grades of pure gases and gas mixtures bringing us to the forefront of this technology. Plus, EcoSmart cylinders are available at no additional cost. The price remains the same as in a throw away! Features: Refillable Portable Lightweight Increases efficiency Holds pure and mixed gases Eliminates disposal fees and regulatory paperwork Part Number 44 ES 58 ES 66 ES 116 ES 650 ES Pressure 825 PSI 1000 PSI 1200 PSI 1000 PSI 1650 PSI Gas Type Dimensions 9.8" x 2.9" 9.8" x 2.9" 10.5" x 2.9" 14.3" x 3.5" 5.25" x 19.25" Water Capacity 0.79 Litres 0.79 Litres 0.79 Litres 1.7 Litres 5.77 Litres Material Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Weight 1.7 lbs 1.7 lbs 1.7 lbs 2 lbs 15.8 lbs with valve Valve Inlet 5/8-18 5/8-18 5/8-18 5/8-18 CGA 330 valve Regulator Demand Flow, 70 Series, 70-SS Series Demand Flow, 70 Series, 70-SS Series Demand Flow, 70 Series, 70-SS Series 70 Series, 70-SS Series 75 DFR/330 Contents 1.5 cu.ft. 2.05 cu.ft. 2.33 cu.ft. 4 cu.ft. 22.8 cu.ft. 102 www.conceptcontrols.com

ACCESSORIES Accessories Cases & Kits CASES 574 GD-HPCC-3 638-0001 Teal Calibration Case Holds (2) 58L 3 Cylinder Soft-Sided Carry Case Black Plastic Case Holds 17 & 34 Litre KITS KG34L421421002 KG34L4047005 KG58L4047005 Bump Test Kit Includes: Black Carrying Case, Bump Gas (34L-421), 0.2 LPM Trigger Reg., Tygon Tubing Concept Calibration Kit Includes: Black Carrying Case, Cal. Gas (34L-404), 0.5 LPM Reg., Tygon Tubing Concept Calibration Kit Includes: Teal Calibration Case, Cal. Gas (58L-404), 0.5 LPM Reg., Tygon Tubing Kits can be manufactured to meet any specific need www.conceptcontrols.com 103

GAS DETECTION: CALIBRATION GAS Regulators 17L & 34LS REGULATORS Part Number 71-* 76-Q71-* CV-2 Valve Inlet CGA 600 CGA 600 CGA 600 Flow Rate 0.1 6 LPM Fixed 0.1 6 LPM Fixed N/A Gauge PSI 600 PSI N/A N/A Material Aluminum or Brass 34L, 58L, 74L,105L, & 116L REGULATORS Part Number 74 DAF 70 & 70/SS-* 75 DFR Valve Inlet C-10 C-10 C-10 Flow Rate 0.3-3LPM Selectable 0.1 6 LPM Fixed On-Demand Gauge PSI 1200 PSI 1200 PSI 1200 PSI Material or Stainless Steel 17L, 34L, 34LS, 58L, 74L, 105L, & 116L REGULATORS Part Number 2007 70 FMV 70-TR IGGER Valve Inlet CGA-600 C-10 or CGA 600 C-10 or CGA 600 Flow Rate On-Demand Flow-Matching 0.1 6 LPM Fixed Gauge PSI 1200 PSI 1200 PSI 1200 PSI Material Brass 104 www.conceptcontrols.com