A novel approach to study locomotion in under-g load bearing conditions

Similar documents
Steffen Willwacher, Katina Fischer, Gert Peter Brüggemann Institute of Biomechanics and Orthopaedics, German Sport University, Cologne, Germany

A portable roller ski rolling resistance measurement system

Inertial compensation for belt acceleration in an instrumented treadmill

Load dynamics of joints in Nordic walking

A New Approach to Modeling Vertical Stiffness in Heel-Toe Distance Runners

Dynamic analysis and motion measurement of ski turns using inertial and force sensors

Characteristics of ball impact on curve shot in soccer

Kick precision and spin rate in drop and torpedo punts

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

Does wearing a wrist guard affect the site of wrist fracture in snow sports?

Available online at Prediction of energy efficient pedal forces in cycling using musculoskeletal simulation models

A Feedback System for the Motor Learning of Skills in Golf

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Ball impact dynamics of knuckling shot in soccer

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers

Artifacts Due to Filtering Mismatch in Drop Landing Moment Data

Available online at ScienceDirect. Brendan Kays a, Lloyd Smith a *

ScienceDirect. Aerodynamic body position of the brakeman of a 2-man bobsleigh

Toward a Human-like Biped Robot with Compliant Legs

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Impact Points and Their Effect on Trajectory in Soccer

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

The effects of a suspended-load backpack on gait

THE EFFECT OF BINDING POSITION ON KINETIC VARIABLES IN ALPINE SKIING

Available online at Procedia Engineering 00 2 (2010) (2009)

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Megan E. Krause, BSBSE, Young Hui Chang, Ph.D. Comparative Neuromechanics Laboratory. Georgia Institute of Technology

Medicine Meets Virtual Reality 21

3 people 3 unique lifestyles 3 advanced foot solutions

DIFFERENCE BETWEEN TAEKWONDO ROUNDHOUSE KICK EXECUTED BY THE FRONT AND BACK LEG - A BIOMECHANICAL STUDY

ScienceDirect. Rebounding strategies in basketball

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance

Basketball free-throw rebound motions

SPRINTING CHARACTERISTICS OF WOMEN S 100 METER FINALS AT THE IAAF WORLD CHAMPIONSHOPS DAEGU 2011

Kinematic Differences between Set- and Jump-Shot Motions in Basketball

AN EXPERIMENTAL INVESTIGATION ON GOLF SHOE DESIGN USING FOOT- PRESSURE DISTRIBUTION DURING THE GOLF SWING

Biomechanical analysis of the medalists in the 10,000 metres at the 2007 World Championships in Athletics

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1.

GROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF

Gait & Posture 33 (2011) Contents lists available at ScienceDirect. Gait & Posture. journal homepage:

Analysis of Skip Motion as a Recovery Strategy after an Induced Trip

Available online at ScienceDirect. Procedia Engineering 112 (2015 ) 40 45

THE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING

ScienceDirect. Relating baseball seam height to carry distance

MODEL OF A PERSON WALKING AS A STRUCTURE BORNE SOUND SOURCE

Toward a Human-like Biped Robot with Compliant Legs

ScienceDirect. Long-distance, short-distance: triathlon. One name: two ways.

RELATIONSHIP OF SELECTED KINEMATIC VARIABLES WITH THE PERFORMANCE OF DOUBLE HANDEDBACKHAND IN TENNIS. Rajesh Kumar, M.P.Ed,

Relationship between Ground Reaction Force and Stability Level of the Lower Extremity in Runners Background: Objective: Design and Setting:

RUNNING SHOE STIFFNESS: THE EFFECT ON WALKING GAIT

Available online at Procedia Engineering 200 (2010) (2009) RETRACTED

Ground Forces Impact on Release of Rotational Shot Put Technique

INCLINOMETER DEVICE FOR SHIP STABILITY EVALUATION

Development of an end-effector to simulate the foot to ball interaction of an instep kick in soccer

Comparison of Kinematics and Kinetics During Drop and Drop Jump Performance

Figure 1 betois (bending torsion insole system) system with five measuring points and A/D- converter.

Mutual and asynchronous anticipation and action in sports as globally competitive

ScienceDirect. Analysis of climbing postures and movements in sport climbing for realistic 3D climbing animations

empower Reclaim your power. Information for technicians empower Ottobock 1

Biomechanics and Models of Locomotion

HRC adjustable pneumatic swing-phase control knee

Keywords: multiple linear regression; pedestrian crossing delay; right-turn car flow; the number of pedestrians;

Non-invasive, spatio-temporal gait analysis for sprint running using a single camera

Does isolated hip abductor fatigue lead to biomechanical changes of trunk, pelvis and lower leg during single-leg landing?

Available online at ScienceDirect. The 2014 conference of the International Sports Engineering Association

Analysis of Gait Characteristics Changes in Normal Walking and Fast Walking Of the Elderly People

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

BIOMECHANICAL EVALUATION OF RUNNING AND SOCCER SHOES: METHODOLOGY AND TESTING PROCEDURES. Ewald M. Hennig

Ground Reaction Force Alterations Due to Experimentally-induced Anterior Knee Pain During Walking

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system

Smita Rao PT PhD. Judith F. Baumhauer MD Josh Tome MS Deborah A. Nawoczenski PT PhD

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Human hoppers compensate for simultaneous changes in surface compression and damping

Empower. Reclaim your power. Information for technicians. Empower Ottobock 1

Denny Wells, Jacqueline Alderson, Kane Middleton and Cyril Donnelly

Analysis of Foot Pressure Variation with Change in Stride Length

Transformation of nonfunctional spinal circuits into functional states after the loss of brain input

Simulation-based design to reduce metabolic cost

ScienceDirect. Friction at the tennis shoe-court interface: how biomechanically informed lab-based testing can enhance understanding

Sample Solution for Problem 1.a

Foot Biomechanics Getting Back to the Base

Available online at ScienceDirect. Energy Procedia 53 (2014 )

Biomechanics of Parkour: The Vertical Wall-Run Technique

Posture influences ground reaction force: implications for crouch gait

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT

Ground Reaction Forces and Lower Extremity Kinematics When Running With Suppressed Arm Swing

THE ANKLE-HIP TRANSVERSE PLANE COUPLING DURING THE STANCE PHASE OF NORMAL WALKING

Walking and Running BACKGROUND REVIEW. Planar Pendulum. BIO-39 October 30, From Oct. 25, Equation of motion (for small θ) Solution is

A COMPARISON OF SELECTED BIOMECHANICAL PARAMETERS OF FRONT ROW SPIKE BETWEEN SHORT SET AND HIGH SET BALL

Diabetes and Orthoses. Rob Bradbury Talar Made

ScienceDirect. Improvement of three-dimensional motion analyzer system for the development of Indonesian gait database

Analysis of ankle kinetics and energy consumption with an advanced microprocessor controlled ankle foot prosthesis.

The effect of different backpack loading systems on trunk forward lean angle during walking among college students

Gait analysis for the development of the biped robot foot structure

Procedia Engineering Procedia Engineering 2 (2010)

Toward a human-like biped robot with compliant legs

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Transcription:

Available online at www.sciencedirect.com Procedia Engineering 60 ( 2013 ) 112 117 6 th Asia-Pacific Congress on Sports Technology (APCST) A novel approach to study locomotion in under-g load bearing conditions Katina Mira Fischer a*, Steffen Willwacher a, Martin Küsel-Feldker a, Gert-Peter Brüggemann a a Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933 Köln, Received 20 March 2013; revised 6 May 2013; accepted 9 May 2013 Abstract The purpose of this study was to develop a methodology for systematically unloading in locomotion, which allows for a simple and comfortable weight reduction to study individual movement patterns and adaptations to under-g conditions. For this purpose an unloading harness was constructed. Further vertical ground reaction forces (vertical GRF) were used to develop a formula to calculate the individual unloading situation with respect to the body weight. The constructed unloading harness system allows for a systematical reduction of body weight. Using vertical GRF data, the developed methods enable to calculate the required system settings to obtain the desired individual unloading situation in static as well as in dynamic situations. 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection 2013 Published and peer-review by Elsevier under responsibility Ltd. Selection of the and School peer-review of Aerospace, under Mechanical responsibility and of Manufacturing RMIT University Engineering, RMIT University Keywords: Unloading harness; instrumented treadmill; gait mechanics 1. Introduction Joint motion is subject specific and assumed to be individually highly repeatable [1, 2]. It is assumed that joint motion follows a path of least resistance determined by, e.g. the shapes of the articular surfaces, tendons, ligaments and muscles surrounding the joints [1]. The preferred motion path is assumed to be the path where the acting internal forces and force requirements are minimized. Experimental results show that changes in skeletal movement due to interventions, e.g. shoes or inserts, are only small and subject * Corresponding author. Tel.: +49-221-4982-5660; fax: +49-221-4971598. E-mail address: k.fischer@dshs-koeln.de. 1877-7058 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of the School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University doi: 10.1016/j.proeng.2013.07.025

Katina Mira Fischer et al. / Procedia Engineering 60 ( 2013 ) 112 117 113 specific [3]. There is evidence that when constraints, such as higher/reduced loads or interventions are imposed, the locomotor system will control muscle activity to sustain the preferred motion path. Weight relieving has the potential to control the total load acting upon the body and thereby to conduct studies determining the effects on the locomotor system and how the body will adapt to changed load. Everyday activities, like walking or running under different loading conditions are already described in the literature. Therefore, devices were developed to systematically reduce body weight to study individual movement patterns and adaptations to under-g conditions [4, 5]. Besides an application for scientific research, some devices were developed for use in rehabilitation programs for post treatments of orthopedic diseases of the lower extremities or in training. Thereby, this device could support the individual demands in a healing process of a patient [6] or induce a controlled training stimulus. Most of the developed unloading harness systems are commercially not available [7-9]. Others demonstrate construction properties which do not allow for a motion analysis. Therefore the purpose of this study was to develop a methodology for systematically unloading in locomotion which allows for a simple and comfortable weight reduction. By analyzing the vertical ground reaction forces, this study also aimed to develop a generally valid formula, calculating the individual unloading situation with respect to the body weight. 2. Methods The study was performed at the biomechanics lab in the track and field indoor facilities of the German Sport University Cologne, Germany. To study locomotion in under-g load bearing conditions, an unloading harness was developed to systematically reduce body weight in a static situation and while running on an instrumented treadmill. Using this setup analog force signals were collected to develop a methodology to validate the individual unloading situation. 2.1. Construction of the unloading device neoprene. For protection and to provide enhanced comfort, a jock strap was worn underneath the wetsuit. For reinforcement, belts were attached to the wetsuit and four carbines were fixed to four points at the hip (close to spina iliaca anterior superior/posterior, left and right respectively) to ensure a load transmission near the center of mass. The harness was supported by Kevlar ropes attached to four pneumatic cylinders (type: DSNU, Ø 25mm Festo, Esslingen, Germany), which applied a nearly constant upward force. The cylinders were mounted pneumatic cylinders, two precision regulating valves (LRP-1/4-10, Festo, Esslingen, Germany) were used. Vertical GRF data was collected with an instrumented force treadmill (Treadmetrix, Park City, UT, USA) at 1000 Hz. Force data were filtered using a fourth order, recursive Butterworth filter with a cutoff frequency of 40 Hz. The data was used to control the loading reduction both in a static and in a dynamic situation. The treadmill consisted of an aluminum belt unit which was carried by four load cells (AMTI, Watertown, MA, USA). The stand-alone load cells were mounted on four heavy steel columns which were connected to a 350 kg base steel plate.

114 Katina Mira Fischer et al. / Procedia Engineering 60 ( 2013 ) 112 117 Fig. 1. A device for simulating under-g conditions, consisting of a custom made harness, supported by ropes which are attached to four pneumatic cylinders. Two precision regulating valves (one valve for two cylinders) ensure a constant pressure of the pneumatic cylinders. (a) Schematic figure of the unloading device, where a ring replaces the costume made harness and the instrumented force treadmill is replaced by a box. (b) Picture of the constructed unloading device with a subject integrated. 2.2. Development of a generally valid formula to determine the individual unloading situation Eleven healthy male subjects (age 26 ± 3 yrs; height 180 ± 7 cm; weight 76 ± 8 kg; mean ± SD) participated in this study. All subjects were free of pain and injury. To calculate the individual unloading situation a gradual load reduction was carried out, whereas the pressure was increased in 20 kpa steps, from 0 Pa up to 500 kpa, both in a static and in a dynamic (running at 3.0 m/s) condition. The maximum pressure level was individually adapted to the unloading situation. Maximum pressures ranged from 300 kpa up to 500 kpa. For every pressure level in the dynamic condition (3 m/s), ten stance phases of the right leg were analyzed. To control the load reduction, vertical GRF were measured by means of the instrumented force treadmill. In the dynamic situation the mean of the maximum GRF of 10 stance phases of the right leg was analyzed for each trial. Every stance phase began with the heel contact and ended with toe off. For calculations a threshold of 50 N was used. For each trial within the static condition the mean vertical GRF (= average body weight) was included. The entire analysis was conducted using custom written Matlab (R2010a, The Mathworks, Natick, USA) code. From those measurements a relative force reduction over pressure function was derived. To detect correlations between the individual unloading situation and the adjusted pressure level a linear regression analysis was performed, whereas the pressure level represents the independent variable and the resulting vertical GRF the dependent variable. In the fitting procedure, regression lines were forced to always match 100% body weight in the 0 Pa condition (Fig. 2.). Therefore, only the slope of the regression line was varied in order to find the regression line that minimizes the sum of squared residuals

Katina Mira Fischer et al. / Procedia Engineering 60 ( 2013 ) 112 117 115 between measured and predicted data points. Due to this approach, linear relative unloading pressure formulae between subjects differed only with respect to the slope of the regression line. Based on this, two methods were developed to calculate the individual unloading situation with respect to the body weight. The first method assumed that a linear relationship between relative unloading and respective pressure levels was existent. Therefore, four calibration measurements at different pressure levels (e.g. 100, 200, 300 and 400 kpa) had to be performed. Based on those calibration data, an individual regression line was generated, allowing necessary pressure levels to be calculated from the requested weight reduction. The second method was developed in order to avoid calibration measurements and the necessity to use an instrumented treadmill. It was assumed that the individual slope of a load reduction over pressure regression line calculated from the static condition was mass. Therefore, nal regression line was derived, taking all 12 subjects into account. Coming back to that final regression, it was possible to determine an individual pressure-unloading relationship and no further calibration measurements. 3. Results The developed unloading harness device allowed for a systematical reduction of body weight. Easy pressure control was possible by using two regulating valves. Subjects were not restricted by the harness system and showed normal gait pattern up to a relief of about 50% body weight. Perception of comfort varied individually. Vertical GRF showed different characteristics between the static and the dynamic condition. In the static condition a reduction of body weight lead to a linear reduction of the vertical GRF for every subject (Fig. 2.). Correlation coefficients varied for the subjects between r = 0.993 and r > 0.999. Maximum pressures ranged from 300 kpa to 500 kpa and effected a reduction of body weight from 58% to 84%. Fig. 2. Exemplary relative body weight over pressure regression line for one subject. Relationship between pressure and body weight did not always prove to be linear for the dynamic condition. Two different characteristics could be detected. Four subjects showed a linear negative correlation between pressure level and weight reduction in percent. For the other seven subjects a curvilinear correlation could be found (Fig. 3.).

116 Katina Mira Fischer et al. / Procedia Engineering 60 ( 2013 ) 112 117 Fig. 3. Representative relative load over pressure graphs for one subject showing a linear behavior (a) and one showing nonlinear behavior (b). The correlation coefficients varied between r = 0.901 and r > 0.997. Maximum pressures ranged from 300 kpa to 400 kpa and effected a reduction of body weight from 38% to 60%. 4. Discussion and conclusion The construction of an unloading harness device to study locomotion in under-g load bearing conditions was successful. Compared to devices using a spring based system [4, 7, 9], this device, working with four pneumatic cylinders, controlled by two regulating valves, was able to apply a nearly constant upward force near the center of mass to relief body weight up to 50%, both in a static and dynamic situation. In contrast to other devices [8] this modified wetsuit and its four point suspension close to the hip allows for a natural movement of the body without limiting upper body movement. In addition a continuous force transmission was obtained. This construction furthermore allows for a three dimensional motion analysis on a marker based system. Comfort of the harness construction was assessed differently by each subject, especially in the pubic area. For better comfort the wetsuit should be replaced, respectively reworked in this area. In the static condition a linear correlation between pressure level and relative reduction of body weight could be detected for every subject. Accordingly this device allows for a continuous weight relief. In the dynamic condition for some subjects a curvilinear correlation of the vertical GRF could be observed. Those results could be explained by subject specific movement patterns or individual adaptation mechanisms to running under reduced body weight. Based on the kinetic data two methods were developed to calculate the required pressure level to obtain the desired individual unloading situation. The first method is based on calibration measurements at different pressure levels. The regression derived from those measurements enabled us to easily read off the necessary pressure level for a wanted weight relief. For this method an instrumented treadmill is necessary. Further the results show that in the dynamic situation the linear correlation is not as strong as in the static situation, which will lead to imprecise forecasting of the unloading situation and highlights the need for nonlinear fitting procedures in subject specific calibration. The second method was based on data of 12 subjects. With the developed formula, the required pressure level for a wanted percentage weight reduction can be calculated. For a valid formula and to minimize the error, data of every weight class is required. In this study data of weight classes between 75 and 90 kg are missing (Fig. 4.).

Katina Mira Fischer et al. / Procedia Engineering 60 ( 2013 ) 112 117 117 Fig. 4. Correlation between the su individual regression slope of the relative body weight over pressure graphs of method 1. Besides, it could be shown that the correlation coefficient varies between the static and the dynamic situation. Therefore, a calibration approach for every condition is required. To improve validity the sample should be enhanced and missing weight classes should be recruited. The constructed unloading harness device allows for a three dimensional motion analysis. In future studies this device should be used to analyze kinematic, kinetic and muscle activity adaptations to reduced body weight. Thereby it could help to determine individual movement patterns and adaptations to under-g conditions. References [1] Nigg B. M., Nurse M. A.,Stefanyshyn D. J. (1999). Shoe inserts and orthotics for sport and physical activities. Med Sci Sports Exerc; 31: S421-8. [2] Müller O., Lo J., Wünschel M., Obloh C.,Wülker N. (2009). Simulation of force loaded knee movement in a newly developed in vitro knee simulator/simulation von belastungsabhängigen Kniebewegungen in einem neuartigen Knie-Simulator für In-vitro-Studien. Biomedizinische Technik/Biomedical Engineering; 54: 142-149. [3] Stacoff A., Reinschmidt C., Nigg B. M., van den Bogert A. J., Lundberg A., Denoth J., et al. (2000). Effects of foot orthoses on skeletal motion during running. Clin Biomech (Bristol, Avon); 15: 54-64. [4] Farley C. T.,McMahon T. A. (1992). Energetics of walking and running: insights from simulated reduced-gravity experiments. Journal of Applied Physiology; 73: 2709-12. [5] Ivanenko Y. P., Grasso R., Macellari V.,Lacquaniti F. (2002). Control of foot trajectory in human locomotion: role of ground contact forces in simulated reduced gravity. Journal of Neurophysiology; 87: 3070-89. [6] Norman K. E., Pepin A., Ladouceur M.,Barbeau H. (1995). A treadmill apparatus and harness support for evaluation and rehabilitation of gait. Archives of Physical Medicine & Rehabilitation; 76: 772-8. [7] He J. P., Kram R.,McMahon T. A. (1991). Mechanics of running under simulated low gravity. Journal of Applied Physiology; 71: 863-70. [8] Gazzani F., Fadda A., Torre M.,Macellari V. (2000). WARD: a pneumatic system for body weight relief in gait rehabilitation. IEEE Transactions on Rehabilitation Engineering; 8: 506-13. [9] Kram R., Domingo A.,Ferris D. P. (1997). Effect of reduced gravity on the preferred walk-run transition speed. Journal of Experimental Biology; 200: 821-6.