CRiSis System Defibrillation Chest Skin LF03652U Instruction Manual

Similar documents
CHILD DEFIBRILLATION CHEST SKIN LF03611U INSTRUCTION MANUAL

Infant ECG/Umbilical Cannulation Skin LF03710U Instruction Manual

Skin and Vein Replacement Kit LF01122 (White Skin) LF01123 (Black Skin) LF01124 (Vein)

CHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U

INJECTABLE TRAINING ARM

Advanced IV Hand LF01139U & LF01146U Instruction Manual

CRiSis System Defibrillation Chest Skin

Child CRiSis Injectable Training Arm LF03612U Instruction Manual

Blood Pressure Simulator LF01095U Instruction Manual

Advanced Airway Larry TORSO MANIKIN LF03960U INSTRUCTION MANUAL

INFANT INJECTABLE TRAINING LEG LF03636U INSTRUCTION MANUAL

CRiSis TORSO MANIKIN LF03957U INSTRUCTION MANUAL

CRICOID PRESSURE TRAINER LF03760U INSTRUCTION MANUAL

CRiSis MANIKIN AUSCULTATION UPDATE PACKAGE LF03967U INSTRUCTION MANUAL

BLOOD PRESSURE SIMULATOR LF01095U INSTRUCTION MANUAL

Airway Larry TORSO MANIKIN LF03669U INSTRUCTION MANUAL

CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL

Airway Larry AIRWAY MANAGEMENT TRAINER INSTRUCTION MANUAL

AIRWAY MANAGEMENT TRAINER LF03601U INSTRUCTION MANUAL

Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual

ADVANCED Airway Larry AIRWAY MANAGEMENT TRAINER LF03685U INSTRUCTION MANUAL

Skin and Vein Replacement Kit LF01122U (Light Skin) LF01123U (Dark Skin) LF01124U (Vein) Instruction Manual

Infant Auscultation Trainer and SmartScope LF01201U Instruction Manual

Complete CRiSis Update Package LF03959U Instruction Manual

Basic KERi THE NURSING SKILLS MANIKIN LF4021U INSTRUCTION MANUAL

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Child CRiSis Manikin Simulator LF03616U Instruction Manual

INTERMEDIATE INFANT MANIKIN LF03700U INSTRUCTION MANUAL

Table of Contents. Introduction 2. Airway Management Trainer 3. IV Arm 4. IV Leg 9. Intraosseous Infusion Leg 14

Infant IV Leg LF03636U Instruction Manual

Deluxe Child CRiSis Manikin LF03617U Instruction Manual

Airway Larry Airway Management Trainer Head LF03667U Instruction Manual

NG Tube and Trach Skills Trainer LF01174U Instruction Manual

Complete CRiSis Torso Manikin LF03957U Instruction Manual. NP114_99_LF03957_CRiSisTorso.indd 1. Manikin LF03957U Instruction Manual

DELUXE CHILD CRiSis MANIKIN WITH ECG SIMULATOR LF03617U INSTRUCTION MANUAL

CPARLENE Series Instruction Manual

HEALTHCARE CPR Metrix

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

AT Kelly Torso. Directions for Use

AT Kelly Torso. Directions for Use

Basic Sanitary CPR Dog LF01156U Instruction Manual

Quality CPR and live defi brillation training with real-time feedback and evaluation report Airways, Standard Resusci Anne (pkg. 24) $111.

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

AED Plus Accessories and Training Products

Texas Multiple Award Schedule (TXMAS) Program Contract Number TXMAS

INSTRUCTION MANUAL. January 23, 2003, Revision 0

ADVANCED KERi NURSING SKILLS MANIKIN LF4022U INSTRUCTION MANUAL

Assembly Instructions. -Cantilever Boat Lifts

ACCESSORIES FOR EVERY RESCUE

ADVANCED GERi NURSING SKILLS MANIKIN LF4030U INSTRUCTION MANUAL

Resusci Anne Simulator

SimNewB. User Guide.

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

Dual Electronic Basketball System Owners Manual

Simulation for emergency care

To assist you in preparing STAT Baby for student activities we offer the following set up suggestions:

Overview. The user must follow the instructions below.

RADROVER REAR RACK INSTALLATION MANUAL

ACCESSORIES FOR EVERY RESCUE

Bleeding Trauma Module Set. Directions for Use

GENERAL SERVICES ADMINISTRATION Federal Supply Service Authorized Federal Supply Schedule Price List

Chapter 9 Accessories for the Kirby Morgan BandMasks

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Tripod Setup Guide (M-TPx)

INSTRUCTION MANUAL NOTE:

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

Disclaimer This material is intended for use by trained family members and caregivers of children with tracheostomies who are patients at the Alberta

BR-2444 ROWING MACHINE

DeskCycle USER S MANUAL. Ellipse QUESTIONS / PROBLEMS. Order# Support and Contact: See the support link at DeskCycle.com

Gel Drop Seal for FOSC 450 Fiber Optic Splice Enclosure Installation Instructions

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

TWB Shoulder Retractors

Pressure Dump Valve Service Kit for Series 2300 Units

TWB Shoulder Retractors

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

OWNER'S MANUAL LOCK-N-LOAD BULLET FEEDER (PISTOL)

T3200 TransPlate Harness

Hose Reel Instruction Manual

VERSA BIKE RACK INSTRUCTIONS

Thank you for purchasing a Porta-Dock product! *Please read and follow these instructions step by step*

Installation Guide, MPower Echelon Console

The World s Best Adductors

General Services Administration Federal Supply Service Authorized Federal Supply Schedule Price List

VISIT THE LIFETIME WEB SITE: **U.S. and Canada customers ONLY** IF ASSISTANCE IS NEEDED, COPY

Backboard and Rim Owners Manual

Defibtech AED Training Equipment. User Manual

AED Trainer NF1200-T. Operator s Manual

COPY. **For U.S. and Canada Customers ONLY:** IF ASSISTANCE IS NEEDED,

VISIT THE LIFETIME WEB SITE: **For U.S. and Canada Customers ONLY:** IF ASSISTANCE IS NEEDED,

Important Note: Tighten lock nuts so the support tubes still swing freely see figure 2. There must be 1 2 threads of bolt past end of lock nuts.

DK ton, Double-acting, Die-type Crimping Tool

Page 1. Single Scull Car Rack Assembly and User s Manual " "

Warranty The device shall have a 6-year warranty at minimum

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

GENERAL SERVICES ADMINISTRATION Federal Supply Service Authorized Federal Supply Schedule Price List

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

Transcription:

CRiSis System Defibrillation Chest Skin LF03652U Instruction Manual Products by Nasco

About the Simulator The CRiSis System Defibrillation Chest Skin has been designed to be placed on the CPARLENE or Resusci Anne * brands of CPR manikins to enable you, the customer, to safely defibrillate using either of these CPR manikins. The Defibrillation Chest Skin has been designed to absorb a maximum of 360 joules of energy**. Although capable of absorbing 360 joules, we recommend that the smallest energy level possible be used while training with the skin. The CRiSis System Defibrillation Chest Skin will enable you to practice defibrillation using manual, semiautomatic, and automatic external defibrillators (AEDs). When using any one of the above listed types of defibrillators in training, always follow the recommended operating procedures for that particular defibrillator. Our chest skin has been specially designed to accommodate either the CPARLENE or Resusci Anne * brand CPR manikins, regardless of the version you have of either manikin. List of Components Defibrillation Chest Skin with Load Box and Four Lead Snap Cable Connected Z Shaped Mounting Bracket Set of Large Thread Screws Set of Bolts with Washers and Wing Nuts *Resusci Anne is a registered trademark of Laerdal Medical Corporation. **Note: 360 joules is the maximum energy level that Nasco recommends administering to the defibrillation chest skin. Energy levels in excess of 360 joules may cause irreparable damage to the chest skin, circuitry, and patient simulator being used thus voiding Nasco s warranty and endangering your equipment. Nasco assumes no liability for damage or injury that may be caused by the use and/or misuse of this equipment. All normal safety precautions for defibrillation training should be followed and energy levels should be minimized. Nasco did not design nor intend this defibrillation chest skin to be used as anything other than a training apparatus for defibrillation. 1

Set Up The CRiSis System Defibrillation Chest Skin has been designed to replace the standard outer chest skin on the CPARLENE and the Resusci Anne * brand CPR manikins, thus enabling you to safely defibrillate these types of CPR manikins. Please follow the setup procedures for the type of manikin on which you wish to place the CRiSis System Defibrillation Chest Skin. Resusci Anne * installation instructions begin on this page. CPARLENE installation instructions begin on page 4. For those of you who have purchased the complete CRiSis manikin, your load box has already been installed for you. You can skip over the setup procedures and go to the operating instructions on page 5. Resusci Anne * Installation Instructions Regardless of the type or version of Resusci Anne * you have, you will be able to use our CRiSis System Defibrillation Chest Skin. Simply follow along with the installation procedures. Removing the Regular Chest Skin In order to install our Defibrillation Chest Skin, you must first remove the outer chest skin that is currently in place on your CPR manikin. This is the device that will absorb the energy being administered to the chest skin during defibrillation. Note: It is very important that this load box is installed properly! The first step is to determine the type of Resusci Anne * you have. Don t worry, our skin works with all the various versions, although the installation techniques may vary. No extra tools are needed; we have provided everything you will need. Lift out the chest plate from the manikin. This will enable you to see down inside the manikin. Installing the Load Box The next step is to install the load box for the defibrillation chest skin. The load box is the box attached to the skin via one large cable and a smaller cable with four lead snaps attached. 2 *Resusci Anne is a registered trademark of Laerdal Medical Corporation.

Basic Resusci Anne * Now your load box is secure. Electronic Version Once the chest plate has been removed, you will need to determine if you have an electronic version or the basic (nonelectronic version) of Resusci Anne *. If you have a basic Resusci Anne * (without the battery pack), the load box must be attached to the back plate of the manikin using the bracket and bolts provided with the chest skin. The back plate is the flat part of the manikin that the legs screw into when attached to the manikin. As you can see from the photos, the electronic version has a battery pack in the lower right hand corner of the chest cavity. The basic does not. To install the load box in the electronic version, simply remove the top of the battery pack and screw our load box down onto the threaded screw sticking up through the battery pack. We have included with the chest skin a bag of hardware and a Z shaped bracket. This bracket should be screwed down tight to the back plate on the right hand side using the screws provided. *Resusci Anne is a registered trademark of Laerdal Medical Corporation. 3

If your manikin has legs on it, use the larger threaded screws to attach the bracket. If you have a torso manikin, simply use the bolts, washers, and wing nuts to secure the bracket. CPARLENE Installation Instructions The load box for the CRiSis System Defibrillation Chest Skin is installed the same way in every version of the CPARLENE, regardless of when you purchased it or the version you purchased. Removing the Regular Chest Skin In order to install the Defibrillation Chest Skin, the outer chest skin currently in place on the manikin must be removed. Once the bracket is in place with the single threaded screw and foam pads pointing towards the inner chest cavity, attach the load box to the screw sticking out and tighten until secure. Installing the Load Box The next step is to install the load box for the Defibrillation Chest Skin. The load box is attached to the skin via one large cable. Your load box is now in place. This is the device that will absorb the energy being administered to the chest skin while defibrillating. Note: It is very important that this load box is installed properly! 4

Once you have the chest skin removed, you must next remove the rib plate and the upper compression plate. The next step is to attach the mounting bracket to the back plate of the manikin. The back plate is the part of the shell where the legs are or would be attached. The bracket should be secured so that the foam pads and single screw stick out toward the chest cavity. If you have a torso manikin without legs, you will need to use the bolts provided with the bracket to mount it. Simply line up the bracket with the holes in the back plate and tighten up the wing nuts until the bracket is securely attached to the back plate. Again, make sure the single screw and the foam pads are pointing in toward the chest cavity. Securing the Load Box Now that the bracket is in place, screw the load box onto the single screw sticking up off the Z bracket. If you have a manikin with legs attached to it, you will already have four screws with washers and wing nuts holding the legs on. To attach the load box in this situation, just loosen one set of these nuts and slide the mounting bracket underneath as shown below. Operating Instructions Replacing the Skin Now that you have secured the load box, uncoil the smaller cable that has the four lead snaps attached. These four lead snaps will eventually be attached to your arrhythmia generator or patient simulator cable. For now, simply uncoil the cable and allow it to hang freely from the manikin. Next, replace the chest plates that you removed earlier and lay the CRiSis System Defibrillation Chest Skin on top of the chest of the manikin. 5

If you have a Resusci Anne *, we have die-cut holes and slots in your chest skin so that it can be stretched over your Resusci Anne * and attached to the posts. If you have a CPARLENE, the hookand-loop fastener has already been sewn onto the skin. Simply line up the hook-and-loop fastener and you are all set. If you want to connect the manikin to the simulator that came with your defibrillator, it is necessary to purchase the corresponding adapters from Nasco separately, if the patient simulator doesn t have the standard snap connectors. (Please see accessories at the end of this manual.) Connecting Your Arrhythmia Generator or Patient Simulator Now that the chest skin and the load box are in place, you will want to connect the four lead snap cable to your arrhythmia or patient simulator. Nasco has designed the CRiSis System to be compatible with a variety of patient simulators. This is possible via the standard four lead snap cable. If your patient simulator has only two output posts, the red and black leads must be connected to the patient simulator. Once your manikin is connected to your patient simulator, you will be able to pick up the ECG waves either through the monitor hook-ups on the skin or through the two disks attached to the skin on the defibrillation sites. These disks will enable you to pick up the ECG wave using either the Quick Look paddle option or directly through gel pads, just like on a real patient. It is possible to use AED gel pads with the cable connectors built into the gel the same ones you use on patients. In an effort to help you save money, Nasco does offer a set of training buttons that will correspond to your particular AED unit. These buttons are sold separately and can be used over and over again. They come as a set with the patient simulator adapters. (See accessories at the end of this manual.) *Resusci Anne is a registered trademark of Laerdal Medical Corporation. 6

Troubleshooting: Problem ECG wave is not being picked up from the manikin. Solution 1. Check your connections on the patient simulators; one or more may be disconnected. 2. Check to make sure your patient simulator is plugged in and working properly. Problem ECG wave is inverted. Solution Recheck the position of the red and black lead snaps on the patient simulator. Note: If the Defibrillation Chest Skin is not functioning or wiring comes undone, please contact us to repair or replace the unit. Failure to do so, or unauthorized repair, may void the warranty or cause further harm or damage to you or your equipment. Accessories LF03656U Physio Control Training Pad Adapters and Patient Simulator Adapters for LifePak 10 and LifePak 20 LF03657U Marquette Electronics Training Pad Adapters and Patient Simulator Adapters LF03658U Space Labs/Laerdal/ Heartstart/First Medic Training Pad Adapters and Patient Simulator Adapters LF03961U Zoll Training Cables with Adapters LF03962U Physio Control Training Cables with Adapters for LifePak 12 Note: If you need help selecting the training pad adapters that correspond to your AED unit, please feel free to call us at 1-800-558-9595 for assistance. 7

Other Available LF00698U Adult Injectable Arm (White) LF00855U Male Catheterization LF00856U Female Catheterization LF00901U Prostate Examination LF00906U Ostomy Care LF00929U Surgical Bandaging LF00957U Enema Administration LF00958U Pediatric Injectable Arm LF00961U Intramuscular Injection LF00984U Breast Examination LF00995U Arterial Puncture Arm LF00999U Pediatric Injectable Head LF01005U First Aid Arm LF01008U Intradermal Injection Arm LF01012U Heart Catheterization (TPN) LF01019U Ear Examination LF01027U Peritoneal Dialysis LF01028U Suture Practice Arm LF01034U Suture Practice Leg LF01036U Spinal Injection LF01037U Hemodialysis Practice Arm LF01038U Episiotomy Suturing Set LF01042U Suture Kit LF01062U Pelvic, Normal & Abnormal LF01063U Stump Bandaging, Upper LF01064U Stump Bandaging, Lower LF01069U Cervical Effacement LF01070U Birthing Station LF01082U Cricothyrotomy LF01083U Tracheostomy Care LF01084U Sigmoidoscopic Examination LF01087U Central Venous Cannulation LF01095U Blood Pressure Arm LF01108U Infant Intraosseous Infusion LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF01142U Auscultation Trainer LF01143U Testicular Exam LF01152U Male & Female Catheter LF01155U Advanced CPR Dog LF01162U Venatech IV Trainer LF01174U NG Tube & Trach Skills Simulators LF01184U Venatech IM & Sub Q LF01193U Special Needs Baby LF03000U CPARLENE Series LF03601U Adult Airway Management Trainer with Stand LF03602U Adult Airway Management Manikin LF03609U Child Airway Management Trainer with Stand LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor LF03620U PALS Update Kit LF03623U Infant Airway Management Trainer with Stand LF03632U Child Intraosseous Infusion/ Femoral Access Leg on a Stand LF03633U Child Airway Management Trainer Torso LF03693U Basic Buddy CPR Manikin LF03699U Airway Larry Airway Management Trainer LF03709U Infant CRiSis Manikin LF03720U Baby Buddy Infant CPR Manikin LF03750U Fat Old Fred LF03760U Airway Management/Cricoid Pressure Trainer LF03770U Chest Tube LF03953U CRiSis Manikin, Complete LF03955U Deluxe CRiSis Manikin LF03956U Deluxe Plus CRiSis Manikin LF03965U Adult CRiSis Auscultation Manikin LF03966U Adult CRiSis Auscultation Manikin with ECG Simulator LF04000U GERi /KERi Manikin Series LF04200U Adult Sternal Intraosseous Infusion LF06001U CPR Prompt Adult/Child Manikin LF06012U CPR Prompt Infant Manikin LF06200U CPR Prompt Keychain Rescue Aid LF06204U CPR Prompt Rescue and Practice Aid Fort Atkinson 901 Janesville Avenue, P.O. Box 901 Fort Atkinson, Wisconsin 53538-0901 1-800-558-9595 enasco.com E-mail: lifeform@enasco.com COPYRIGHT NASCO 1994 PRINTED IN U.S.A. NP 76-94/RV 7-12