The evolution of the Ex-proof flame path

Similar documents
Explosive atmospheres

Hazardous (Classified) Locations

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

SECTION BUTTERFLY VALVES

Coiling Tube with Twist-Proof Fitting

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

IECEx certification of Non-Electrical Ex Equipment

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Technical Data Sheet TI-F50 Locking Units series KFH

Torque Tube TB300 Digital Transmitters

The Omron STI Hazardous Location

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

PENCOFLEX COUPLING ASSEMBLY AND MAINTENANCE

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

OPENINGS AND REINFORCEMENTS 26

IECEx Certificate of Conformity Annexe

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

Type Testing Procedure for Crankcase Explosion Relief Valves

CFSW. Hinges with built-in safety multiple switch

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Electro-Pneumatic Converter YT-940 SERIES

OMS Technical Information Technical data

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Accu Max Limited Warranty

Push-In Fitting Type with Stop Valve

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

IECEx Certificate of Conformity

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Push-In Fitting Type Silencer

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Operating Instructions

OFFICINE OROBICHE S.p.A. 1/9

Push-In Fitting Type Pressure Gauge

Telefon (+45) Telefax (+45)

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

OMS Technical Information. Versions OMS. Versions

FLAMEPROOF EQUIPMENT DESIGN AND CERTIFICATION

Pressure Switches Application Guideline

ISO 5171 INTERNATIONAL STANDARD. Gas welding equipment Pressure gauges used in welding, cutting and allied processes

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

4 Machine maintenance and repair

patented standards SAFETY QUICK COUPLINGS EXPERTISE AT THE SERVICE OF SAFETY AND PERFORMANCE a n d ot h e r p e n di n g

Liquefied gas cargo tanks and process pressure vessels

CFSW. Hinges with built-in safety multiple switch

6-5 Maintenance Manual

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN

OPERATION MANUAL PNEUMATIC VALVES

NEW TYPE M PRESSURE RELIEF DEVICE

Rolled Rotary Ball Screw

pipe connectors. General description of pipe connectors Development/Design Purpose Versions

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

Pressure Measurement Single-range transmitters for general applications

II 2G EEx ia IIC T6. Ignition protection class

World Area Differences Technical Information

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Precision Rotary Ball Screw

CAST IRON SAFETY VALVE TYPE 6301

ExMC15 IECEx certification of non-electrical Ex equipment Summary of how the standards deal with ignition hazard assessment

Installation of Ballast Water Management Systems

Installation, operation & maintenance manual - original version

Certificate of Conformity

Liquid Ring Compressor Catching Chemicals Conserving Cash

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Tube Cutter with Measuring tape built-in

MIE TALK May INTRODUCTION. South African Flameproof Association Page 1 of 19

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Pioneers. Ex-ENGINEERING. Quality

Gas Welding Hoses and connections, the weak link

USER MANUAL PNEUMATIC SERIES SL 275 SL 475 SL(-2) 10 GX 14 GX(-2) 20 DX(-2) 34 GX(-2) 40 DX 46 GX DX 110 DX

Deep groove ball bearings L12DDU. Polyolefin is used for packaging food in supermarkets, replacing dioxin-generating vinyl chloride.

TEST SPECIFICATION NYT-909-C

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

MSC Guidelines for Independent Fuel Tanks

INDICATIONS FOR CHOICE OF ATEX FANS

Guidance on room integrity testing and its interpretation

GM Series Dual-Block Multi-Function Gas Control Valves

THE PROCESS OF JOINT INTEGRITY

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Vehicle-mounted meters, pump supplied

Horizontal Bladder Tanks

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Transcription:

April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into National standards (CEI EN 60079-...), Community standards (EN 60079-...) and international standards (IEC 60079-...), which in fact are the same, we will quote below only the reference 60079-... The reference standard, 60079-1 "Explosive atmospheres Part 1: Equipment protected by explosion proof enclosures d, has been updated so that in this discussion we will analyse the changes relating to the use of the flame path. This is the oldest method of protection that exists, the first used and still one of the safest because it is based on a very simple technology and, therefore, hardly fallible. This method, designed for protection in systems where may be an explosive atmosphere in form of gas, is based on the assumption that it s impossible to prevent a gas to penetrate everywhere. No gasket will ever be able to prevent the entry of a gas in an enclosure. Therefore, if an explosive atmosphere penetrates into an enclosure producing a trigger, for example a spark between two electrical contacts, the explosion occurs, but it remains confined within the enclosure and does not allow the spread of flame to the surrounding atmosphere, thus causing a devastating explosion. To ensure this, enclosures must be constructed with a mechanical strength such as to contain the overpressure caused by the explosion and to allow the escape of flue gases. This is the mission of the flame path which is the interface between two parts of an enclosure, for example the body and the lid. It allows the gases to exit the enclosure and to cool down during the passage, so that they are no longer able to trigger the outside atmosphere. For this reason, the flame path must be sufficiently long and with an interstice enough narrow to guarantee the cooling of the flue gases. Flame path, whether of permanent closed type or of the type intended to be opened occasionally for operation and/or maintenance operations, must meet, in the absence of pressure, the requirements of standard 60079-1 standard and considering that that they have to be sized to support the mechanical effort resulting from the internal deflagration phase. The flame path may be of different types, depending on the nature of the gas and the volume of the housing and, consequently, they will have a size and shape depending on the type of gas present in the environment of installation of the explosion-proof equipment. 1

To better exemplify how many and which types of flame paths are provided for the Standard 60079-1, we will give a brief description, considering the limitation of their use in accordance with what prescribed in Tables 2 and 3 of this Standard, which for convenience we report here below. Table 2: Minimum width of the flame path and maximum gap for enclosures of Group I, IIA and IIB Note 1 For the determination of the maximum distance, the constructive values must be rounded in accordance with ISO 80000-1 (3) Standard. Note 2 In this edition of 60079-1 Standard, two new columns were introduced to divide the "V" volume. This subdivision has been made to introduce maximum dimensions of the gap for cylindrical flanged joints or spigot ones with a minimum length "L" of 9.5mm, as it was non-existent in the previous version of the standard. In particular, it has been introduced the "0:08" value for the group IIA and IIB, with "V" volume 2000 <V 5750 V and> 5750. Note 3 These gap and volume maximum values associated, are based on historical US data, for Class I, Division 1, according to the documentation from ANSI/UL 1203 (4). 2

Table 3: Minimum width of the joint and maximum gap for enclosures of Group IIC Note: For the determination of the maximum distance, the constructive values must be rounded in accordance with ISO 80000-1 Standard. a Flanged joint is permitted for explosive mixtures of acetylene and air only if they comply with para 5.2.7 of the standard 60079-1. b The maximum gap of the cylindrical portion is increased to 0.20 mm if "f" <0.5 mm c The maximum gap of the cylindrical portion is increased to 0.25 mm if "f" <0.5 mm 3

Now, we analyse the various types of flame path considered in the 60079-1 standard currently in force. 1. Threaded joints Threaded joints shall be complying with the requirements of Tables 4 and 5 of 60079-1 standard. They are divided into two types such as: a. Cylindrical joints (refer to Table 4 of 60079-1 Standard), they must have a larger pitch than or equal to 0.7 mm, whereas if the step is greater than 2 mm, special precautions may be necessary as a greater number of full threads in order that these threads meet the test of non-transmission of an internal explosion, as prescribed in the tests of non-transmission of an internal ignition (see para 15.3 of the standard); furthermore, the shape of the thread and the quality of workmanship may have the average or fine tolerance, according to ISO 965-1 and ISO 965-3 standards or, if they do not comply with these standards other threads are allowed, in relation to the thread shape and the quality of processing, if it is exceeded the flame-proof test always prescribed in para 15.3 of the standard, when the length of the threaded joint is specified by the manufacturer; It is reduced as specified in Table 9 of the Standard; they must have at least 5 full threads; they must have a length of thread greater or equal to 5mm for volume less than or equal to 100 cm 3 or greater than or equal to 8 mm for volume higher to 100 cm 3. b. Tapered joints (refer to Table 5 of 60079-1 Standard), they must have at least 5 threads of the same size, both on the external and internal side; thread must meet the NPT requirements, according to ANSI/ASME B1.20.1 and must ensure a firm coupling; accessories with male thread with an edge or an thread interruption must be provided with an effective length of the thread not less than the "L2" and a length dimension of not less than "L4" between the face of the edge and the end of the accessory thread; the internal threads must be controlled using a buffer calibre, for the verification of the L1 measurement. 4

2. Non-threaded joints The non-threaded joints shall be complying with the requirements of Tables 2 and 3 of the 60079-1 standard, reported above and they consist of: a. Spigot joints. For the determination of the "L" width of spigot joints, one of the following shall be taken into account:. both the cylindrical part and the plane part. In this case, the gap shall nowhere exceed the maximum values shown in Tables 2 and 3 (see Figure 1a). the cylindrical part only (see Figure 1b). In this case, the plane part need not to comply with the requirements of Table 2 and 3. Figure 1a: Cylindrical part and plane part Figure 1b: Cylindrical part only Key L= c + d (I, IIA IIB, IIC) d 0.50 L (IIC) 5

c 6.0 mm (IIC) 3.0 mm (i, IIA, IIB) f 1.0 mm (I, IIA, IIB, IIC) b. Conical joints. When joints include conical surfaces, the width of the joint and the gap perpendicular to the joint surface shall comply with the relevant values of Table 2 and Table 3 above. The gap shall be uniform through the conical part. For electrical equipment of Group IIC, the cone angle shall not exceed 5. Note: The cone angle is the angle between the major axis of the cone and the surface of the cone. c. Joints with partial cylindrical surfaces (not permitted for Group IIC). There shall not be intentional gap between the two parts. The width of the joint shall comply with the requirements of the Table 2 above. The diameters of the cylindrical surfaces of the two parts forming the flameproof joint and their tolerances shall ensure the compliance with the relevant requirements for the gap of a cylindrical joint as per Table 2 above. d. Flanged joints for acetylene atmospheres. Flanged joints are permitted for electrical equipment of Group IIC intended for use in explosive gas atmospheres containing acetylene providing all the condition required at the paragraph 5.2.7 of the 60079-1 Standard (gap I: 0.04mm; width L 9.5 mm and volume 500 cm 3 ). e. Serrated joints. They don t need to comply with the requirements of Table 2 and table 3 above but shall have at least five full threads, a pitch greater than or equal to 1.25 mm and an included angle of 60 (± 5 ). This serrated joints shall only be used for joints that are fixed during operation. Serrated joints shall satisfy the test requirements of 15.3 of the 60079-1 Standard. 6

Key Y 5 T T 1.25 mm Test length: Y/1.5 α = 60 (± 5 ) f. Multi-step joints. They consist of not less than 3 adjacent segments where the path changes direction not less than two times by 90 ± 5. Multi-step joint doesn t need to comply with the requirements of Table 2 or Table 3 above, but shall satisfy the test requirements of 15.3 of 60079-1 Standard, with the test length of each segment reduced to not more than 75% of the manufacturer s specified minimum length. For flameproof enclosures that incorporate multi-step joints, the equipment certificate number shall include the X suffix in accordance with the marking requirements of 60079-0 Standard and the specific conditions of use listed on the certificate shall detail one of the following: - Dimensions of the flameproof joints shall be detailed; or - Specific drawing with details of the dimensions of the flameproof joints; or - Specific guidance on how to contact the original manufacturer for information about the dimensions of the flameproof joints; or - Specific indication that the flameproof joints can t be repaired. Key H = 3 adjacent elements a = 90 ± 5 7

3. Holes in joint surfaces Where a plane joint or the plane part or a partial cylindrical surface of a joint is interrupted by holes intended for the passage of threaded parts for the assembling of a flameproof enclosure, the distance l to the edge of the hole shall be equal to or greater than 6 mm when the width of joint L is less than 12.5mm; 8 mm when the width of joint L is equal to or greater than 12.5 mm but less than 25 mm; 9 mm when the width of joint L is equal to or greater than 25 mm. The distance l is determined as follows. - Flanged joints with holes outside the enclosure Figure 3 Figure 4 The distance l is measured between each hole and the inside of the enclosure - Flanged joints with holes inside the enclosure Figure 5 The distance l is measured between each hole and the outside of the enclosure - Spigot joints in which to the edges of the holes, the joint consist of a cylindrical part and a plane part. 8

Figure 6 The distance l is defined as the sum of the width a of the cylindrical part and the width b of the plane part, if f is less than or equal to 1 mm and if the gap of the cylindrical part is less than or equal to 0.2 mm for electrical equipment of Groups I and IIA, or 0.15 mm for electrical equipment of Group IIB, or 0.1 mm for electrical equipment of Group IIC (reduced gap) or the width b of the plane part alone, if either of the above mentioned conditions are not met. - Spigot joints where, to the edges of the holes, the joint consist of the plane part, in spite of plane joints are permitted (see paragraph 5.2.7 of 60079-1 Standard). Figure 7 Figure 8 The distance l is the width of the plane part between the inside of the enclosure and a hole, when the hole is outside the enclosure (Figure 7), or between a hole and the outside of the enclosure where the hole is inside the enclosure (Figure 8). 9

4. Flame paths on rotating machines On Ex d rotating electrical machines, it s necessary to provide a flame path on the propeller shaft. Flame paths positioned in such places must not be subject to wear. They must be completely free and independent from the other structures that support the propeller shaft allowing the rotation. Any bearings, seals, lubrication channels, etc. must be outside of the length of the flame path and it must not be interrupt. 5. Gaskets (including O-rings) If a gasket of compressible or elastic material is used, for example, to protect against the ingress of moisture or dust or against leakage of a liquid, it shall be applied as a supplement and not considered in the determination of the width of the flameproof joint nor interrupt it. 6. Roughness The surfaces of joints shall be such that their average roughness Ra does not exceed 6,3 µm. Note: average roughness is derived from ISO 468. Determination can be made by visual comparison to a reference plate. Today the flame path surfaces, thanks to machining carried out by modern machine tools with numerical control, reach degrees of roughness enormously lower and, therefore, more safe. 7. Joints protected against corrosion The surface of the flame path can be protected against corrosion but is not admitted their coating with paints or finishes based powder. Other types of coatings can be used, if it is proved that the material used and the procedures to apply it does not adversely affect the coupling of flame path properties. It is possible to apply an anti-corrosion grease before assembly. The fat, when applied, must be of type nonhardening with aging, it must not contain solvents which evaporate and must not cause corrosion of the joint surfaces and the verification of its suitability must be in accordance with the manufacturer's specifications fat. We conclude recalling that to ensure the safety of the enclosure, it is appropriate to check that the flame paths are not obstructed and that they are not in close proximity to solid objects such as pipes, walls, trellises or even other enclosures, which may impede the proper exit of gases fuels. In this regard, please refer to the mounting and installation requirements contained in the 60079-14 standard. 10