SM8200. SO2/NO In Situ Multi-Gas Analyzer

Similar documents
Model EXAxt AV550G. Averaging Oxygen Analyzer

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

Autocalibration Systems For In Situ Oxygen Analyzers

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Thermo Scientific Model 146i Principle of Operation

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Best Practice Guide, Servomex 2700

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

Autocalibration Systems for In Situ Oxygen Analyzers

BUBBLER CONTROL SYSTEM

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Datasheet: K-30 ASCII Sensor

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

THERMAL MASS FLOW MEASUREMENT FOR GASES

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Columbus Instruments

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

BUBBLER CONTROL SYSTEM

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

UniCEM. Continuous Emissions Monitoring System

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

SEC Signature DIR Process Monitor

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Pneumatic high-pressure controller Model CPC7000

GasSense NDIR User Manual

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Pneumatic high-pressure controller Model CPC7000

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

Improve Process Reliability

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

MMS Mercury Monitoring System for Natural Gas

Digital deadweight tester Model CPD8500

Application Note AN-107

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Design Features. General Description

Precision pressure sensor Basic version Model CPT6020

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AMT-Ex Dewpoint Transmitter

PRC CO ² -LASER PRESENTATION

Overview. Front Panel: Keypad and Display

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

ACV-10 Automatic Control Valve

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Automatic Isokinetic Sampler. ST5 Evo

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

FPG8601 Force Balanced Piston Gauge

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Digital dead-weight tester Model CPD8500

PRODUCT CONFORMITY CERTIFICATE

EasyLine Continuous Gas Analyzers. So smart, they re simple

Instruction Manual. Biogas Analyzer InCa Bio 04

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

deltaflowc deltaflowc Venturi or Probe

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

SDX Submersible Depth Transmitter User Manual

OXYGEN MONITORING SYSTEM OMS

Mass Flowmeters. Mass Flowmeters for Gases

Optical Dissolved Oxygen Meter

MB3000-CH90 and MBGAS-3000CH FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

SDX Submersible Depth Transmitter User Manual

UNDERSTANDING, ACCELERATED

EASIDEW TRANSMITTER with Current Source Output

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Flow metering in gases Introduction to COMBIMASS family

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Transcription:

SM8200 SO2/NO In Situ Multi-Gas Analyzer

The SM8200 combines state-of-the-art chemometric spectroscopic analysis software and second-derivative (d2) ultra violet (UV) technology with the proven features of the SM81XX series of analyzers to provide a rugged in situ analyzer. The SM8200 provides a unique innovative approach to monitoring SO2 and NO in utility and industrial process emission monitoring applications. This unique technology allows the SM8200 to measure the absorption of UV energy by SO2 and NO molecules, with no interference from H2O, CO, O2 or CO2 as is common with other analytical techniques. Unlike extractive techniques, this method does not require gases for reference, sample conditioning, pumps, or other plumbing which can leak or cause sample degradation. With no continuously moving parts, the SM8200 offers the ultimate in reliability. The SM8200 transceiver includes a built-in keypad and display that enables the operator to configure, diagnose, calibrate, and operate the instrument while on the stack or duct. This allows basic maintenance and calibration procedures to be done by a single person without control room support. The on-stack equipment works in conjunction with Teledyne Monitor Labs Enhanced Remote Panel (ERP), and can also handle an optional O2 or CO2 analyzer. The ERP provides a 14 line by 30 character display so that complete data can be simultaneously displayed for each analyzer. It further provides Ethernet access to all measurement and status information as well as digital contact closure and analog outputs. This measurement, control and reporting capability, when used with a Teledyne Monitor Labs RegPerfect Data Acquisition System (DAS) fully meets the requirements of U.S. EPA 40CFR75 as well as 40CFR part 60 for continuous emission monitoring systems (CEMS). The SM8200 features a choice of calibration cross-checks, including AUTOMATIC DYNAMIC CALIBRATION which enables the measurement accuracy to be verified with calibration gases measured at the same temperature and pressure as the flue gas being measured, and an alternate electro-optical calibration which uses an internal gas filled cell to verify the span stability of the instrument. Designed to operate with gases having high water vapor content, high particulate loading and high temperatures, the SM8200 is ideally suited to a variety of combustion gas monitoring applications, including installation prior to particulate control equipment such as baghouses and Electro Static Precipitators (ESP) and after DeNOx emission control systems. FEATURES LOW MAINTENANCE With a time-tested ceramic diffusion cell, rugged design, and proven measurement technique, six to twelve months of reliable, maintenance-free operation is typical. An innovation in lamp control techniques has considerably extended lamp life, compared to earlier UV in situ analyzers. FLEXIBLE MEASUREMENT RANGES Internal gains for each measurement channel can be independently adjusted to provide optimum accuracy for each gas of interest. Measurement cavities are selectable from less than one centimeter (cm) to 150 cm to accommodate an extensive range of gas concentrations from single digit to percent concentrations. The power of chemometrics also allows the SM8200 to handle wider ratios of SO2 versus NO than was previously possible with the original d2 technology. Chemometrics is the application of mathematical techniques to chemistry data, typically spectra of one type or another. There are many techniques, most of which look for correlations between the spectral and gas concentration data sets. We use Partial Least Squares (PLS) to develop the models used in the SM8200.

CALIBRATION VERIFICATION Unequaled measurement accuracy is made possible through in situ dynamic gas calibrations for both zero and span. Zero gas can either be supplied via instrument air or a separate bottled gas. VERSATILE Selectable measurement cavities/ ranges and probe lengths that accommodate gas temperatures to 800 F make the SM8200 ideally suited to a variety of combustion m o n i t o r i n g a p p l i c a t i o n s, including hot and dirty gases. Additionally, a variety of analog and digital inputs and outputs are available through the Analyzer Electronics Box (AEB) and ERP which can be made a part of the CEMS data records. INEXPENSIVE AND EASY INSTALLATION Major assemblies are easily handled by a single person. The SM8200 mounts on a single port, with data transmitted from the stack to the ERP over a single pair of shielded wires using a field proven LONWORKS network approach. This data link also incorporates electrical isolation for high data integrity in typical harsh industrial environments, and is largely immune to nearby lightning activity. IN SITU PROBE The proven probe design permits in situ gas measurement without any sample extraction, conditioning or transport. The stainless steel probe includes a Resistance Temperature Detector (RTD) gas temperature sensor and selectable gas measurement cavity. It also incorporates a port for injecting calibration gas into the measurement cavity and a gas pressure sensing port which allows continuous correction for changes in gas pressure. The optical pathlength of the measurement cavity is precisely defined by a quartz window and retro-reflector assembly. As the stack gases diffuse through the ceramic filter and into the measurement cavity, the ultraviolet measurement beam is absorbed according to the unique absorption characteristics of the SO2 and NO in the stack gas. SYSTEM COMPONENTS This porous diffuser concept has been tested in thousands of industrial installations and has proved to provide high reliability and very low maintenance. Optical contamination is avoided by encasing the measurement cavity in a porous, nonreactive, ceramic diffuser. This element permits the gaseous components to diffuse into the measurement cavity, while blocking particulate matter. Clogging is prevented by an aerodynamic deflector that keeps particulate from accumulating on the sides of the diffuser. CYLINDER GAS AUDITS Provide easy traceability to known standards, greatly reducing the effort and cost of U.S. EPA certification and periodic multigas quality assurance audits. Cylinder gas audits (CGA) can be automated with an optional CGA audit box. OFF SITE ACCESS Ethernet interface connectivity allows remote access to all major instrument diagnostic information. This eliminates the need to be at the installation site to observe what is going on with the analyzer.

TOP VIEW (HORIZONTAL FLOW) PRINCIPLE OF OPERATION TRANSCEIVER The transceiver contains the optical system which provides the spectral information that allows the second derivative based measurement values to be computed, with typical one-minute updates of SO2 and NO measurements. The measurement technique is also inherently compensated for changes in the light level which may occur as a result of lamp aging, gradual buildup of optical contamination on the exposed, but protected, retroreflector and window, and shifts in alignment due to temperature and mechanical stress. The optical system is temperature stabilized to minimize sensitivity to ambient temperature. It is easily removed from the probe and disconnected from the AEB for off-stack maintenance. The transceiver also contains a Local User Interface (LUI) which includes a display and keypad for monitoring and controlling the analyzer measurement, diagnostic, and configuration information. This allows for easy on-stack evaluation and/or correction of calibration and operational status. ANALYZER ELECTRONIC BOX Mounted beneath the transceiver, the Analyzer Electronic Box (AEB) assembly provides transceiver measurement information to the controller over an electrically isolated LONWORKS network data link. The AEB, which is continuously purged with instrument air, contains a pressure regulator and gauges to regulate gas flow during calibrations and purge air. An optional pc board contains input/ outputs to the O2 analyzer which is required for pound per million British Thermal Unit (BTU) calculations. ENHANCED REMOTE PANEL Typically mounted in the control room, the Enhanced Remote Panel (ERP) incorporates a display and keypad which provides for fault monitoring, emission alarms, measurement access, and automatic or manually timed calibration cycles. It further outputs measurement data in both analog and digital and provides Ethernet access. The SM8200 multi-gas analyzer enhances the d2 techniques developed in the SM81XX series of gas analyzers, and proven in thousands of installations, by adding the vast mathematical power of chemometric techniques. Chemometrics, as we use it, is the application of mathematical techniques to chemistry data, typically spectra of one type or another. There are many techniques, most of which look for correlations between the spectral and gas concentration data sets. We use Partial Least Squares (PLS) to develop the models used in the SM8200. The analyzer measures the UV response of SO2, NO, and other gases, using a 512 element photo diode array (PDA) in association with a dispersive element (diffraction grating) to establish 512 individual pixel, or wavelength, measurements of a gas stream. At the factory we apply a variety of gas mixtures, known as the training set, which are analyzed using a unique combination of partial least squares techniques, statistical smoothing and derivatizing algorithms, and matrix mathematical operations. These routines, along with measurement of the PDA dark current, the sample cell clear path, and the spectra of the gas sample, are used to create a calibration matrix that allow the analyzer to calculate the unique combination of gases in the stack sample that are in the observed spectra of that sample. Additionally, the spectra are analyzed to allow us to just use that portion that provides the most unique information of interest, further reducing the potential for interference from other gases. The data is also corrected for temperature and pressure, which are measured along with each spectra. The result is a simplified optical system without any continuously moving parts, high voltage power supplies, or photo multiplier tubes. We end up with a very accurate, rugged, and durable software based analyzer which surpasses previous analytical techniques, and which is easily adapted to a great variety of applications, which may include hot and dirty gases with denox emission control systems.

Specifications MEASUREMENT RANGES SO2 and NO Minimum 0 to 50 ppm; Maximum 0 to 10,000ppm GAS MEASUREMENTS LOWER DETECTABLE LIMITS GAS MEASUREMENT CHARACTERISTICS COMMON TO ALL GASES POWER & INSTRUMENT AIR REQUIREMENTS AMBIENT OPERATING CONDITIONS MEASUREMENT MEDIUM CONDITIONS FOR GAS MEASUREMENT WIRING REQUIREMENTS, ANALYZER TO ENHANCED REMOTE PANEL SO2/NO Range Ratio Minimum 0.125; Maximum 8 Stack Temperature Measurement Range: 0 to 800 F (-17.8 C to 426.7 C) (LDL S defined as standard deviation of 15 successive one-minute measurements) (valid from 75 F to 400 F (23.9 C to 204.4 C) SO2 NO Response Time Measurement Principle Environmental Regulatory Compliance Calibration Drift, Zero & Span Linearity Analyzer Electronics Box Analyzer Instrument Air Calibration Gas Heater (Part 75 only) Enhanced Remote Panel Power Multi I/O Module Power (optional) Plant I/O Module Power (optional) Analyzer Electronics Box and Transceiver Enhanced Remote Panel & (Optional) Multi I/O Module Static Pressure Range for Valid Measurement Maximum Particulate Concentration Humidity Temperature Range for Valid Measurement Network Transceiver Type Cable Type Termination Style Maximum Distance Between Analyzer & Enhanced Remote Panel Maximum Total Network Length 1% of nominal full scale, or 1.5 ppm, whichever is greater 1% of nominal full scale, or 1 ppm, whichever is greater Adjustable to a minimum of 200 seconds to 95% of value 2nd Derivative UV Absorption Spectroscopy with Chemometrics USEPA 40CFR60 OR USEPA 40CFR75, dependent on instrument configuration and options ± 2.5% of range, or 5 ppm for range <200 ppm, whichever is greater ±5% of Reference Value from 20 to 100% of range (valid from 75 F to 400 F (23.9 C to 204.4 C) 115 VAC 575 VA Maximum 230 VAC, 590 VA Maximum 47-63Hz, Single Phase, Factory Wired Analyzer requires 0.1 CFM to 0.706 CFM (2.8 to 20 LPM) of clean, oil-free dry air or N2 at 69.6 PSI to 101.5 PSI (480 to 700KPa) gauge 115/230 VAC 300 VA Maximum 85-245 VAC, 47-63Hz, Single Phase, 30 VA Maximum Fuses 2 Amp Time Delay, 250V, 5x20mm 85-245 VAC, 47-63Hz, Single Phase, 25 VA Maximum Fuses 2 Amp Time Delay, 250V, 5x20mm 85-245 VAC, 47-63Hz, Single Phase, 25 VA Maximum Fuses 2 Amp Time Delay, 250V, 5x20mm Temperature Range: -30 to +130 F (-34.4 to 54.4 C). Relative Humidity Range: 0 to 100% condensing. Barometric Pressure Range: 18 to 32 Hg (61.1 to 108.6 KPa). Enclosure Rating: NEMA4 Temperature Range: +32 to +104 F(0 to +40 C) Relative Humidity Range: 0-95% non-condensing ±20 H2O (±4.98 KPa) Gauge 4.37 grains/scf (10,000 mg/nm3) Non-condensing. 75 to 800 F (23.9 to +426.7 C) Free Topology Transceiver (FTT10A) 2 conductor shielded twisted pair, 16 AWG (Alpha 5610B1601 or equivalent) Jumper Selectable Double Termination (Internal) 3281 feet (1000 meters) [must be Double Terminated] 3281 feet (1000 meters) [must be Double Terminated] ENHANCED REMOTE PANEL I/O 2 Serial Ports 1-RS232C, 1-RS422 or RS485 (selectable) 1 Ethernet Port 10/100 Base T 4 Analog Outputs 4-20 ma* 8 Digital Inputs Dry, Isolated or Non-Isolated* 8 Relay Outputs Single Pole Single Throw, Normally Open* *Note: Optional Multi I/O Board will Double these above outputs.

DYNAMIC GAS CALIBRATION The gas calibration technique can be activated either automatically at predetermined intervals, manually from the ERP or LUI, or via digital command. When the instrument enters the automatic gas calibration cycle, zero gas is first flowed into the measurement cavity to establish a true zero concentration baseline. Then, a high level calibration gas of known concentration is injected into the measurement cavity where it is measured at the same temperature and pressure as the stack gas. Purge and averaging times are menu selectable, and calibration values are output from the Enhanced Remote Panel. Automatic selectable correction for calibration drift is applied after the calibration check is completed. When the calibration gas is injected into the measurement cavity through the port provided on the mounting flange, it provides a complete check of the measurement system, including all components used in measuring the normal stack gas concentrations. Gas measurements are continuously corrected for the effects of variable gas temperature and pressure. APPLICATIONS The SM8200 is ideally suited for industrial emission monitoring applications. It is designed for a wide range of stack gas conditions, and can be applied in extremely dirty gas applications such as encountered before ESPs or baghouses. It can be used in conjunction with an O2 or CO2 analyzer to provide SO2 and NO, in pounds per million British Thermal Unit (BTU), or pounds per hour with appropriate flow measurements. The SM8200 can be used for tuning low NOx burners as well as complete CEMS applications. Gas concentrations are available in either parts per million by volume wet basis (v/v wb) or milligrams/normal meter cubed (mg/nm3) and stack temperature is available in degrees C or F. Measurement averages are selectable up to about 60 minutes. As a result, the SM8200 is easily integrated into a CEMS for compliance applications, or a process control system. A full range of TML services are available to support the instrument from startup, training, and certification, through on-call or periodic contract maintenance. SPAN CELL CALIBRATION CHECKS The instrument includes an internal span cell containing both SO2 and NO gases which can be solenoid activated. When this electro-optical mode of calibration is selected, the calibration cycle consists of a zero calibration based on flowing zero calibration gas into the measurement cavity, and then an upscale check based on inserting the span cell into the light beam. This calibration check does not provide for automatic span correction, but does provide a simple method of verifying instrument operation and stability without consuming calibration gases. This method can also be selected either automatically, manually, or by command from an external DAS. The SM8200 is inherently linear, but adjustments have been provided to match the measurements to 40CFR75 specified calibration gases. An adjustable linearizer is provided to allow trimming the output for low, mid, and high level measurements. OPTIONS Multi I/O Module: The Multi I/O module provides additional outputs from the SM8200. The module connects to the analyzers LONWORKS network and can be located either with the ERP or remotely from the Transceiver. The unit doubles the available Analog Outputs, Digital Inputs, and Relay Outputs from the SM8200. Plant I/O Module: The Plant I/O Module provides a means to bring external plant operating data (such as Unit Up/Down, Fuel Flows, Fuel Type, etc.) into the SM8200 which can then be transmitted into the DAS System. The module connects to the analyzers LONWORKS network and can be located with the ERP either remotely or from the Transceiver. Cylinder Gas Audit Box: This box provides the valves and control necessary to automate the CGA procedure. 35 Inverness Drive East / Englewood, Colorado, USA 80112-5189 +1-303-792-3300 Fax +1-303-799-4853 tml_sales@teledyne.com www.teledyne-ml.com For the most current information, please visit our web site: www.teledyne-ml.com Teledyne Monitor Labs, Inc. reserves the right to make changes in construction, design, specifications, and/or prices without prior notice. PL/SM8200/12/08