Operating Instructions. Predilution chamber EC. BA 821C/24/ae/01.07

Similar documents
Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Pressure Reducing Valve DMV 755

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Flowmeter. Original operating manual DFM

Gas Pressure Regulator HON 200

For the highest operational safety around the clock

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Flow control valves Series RFU - RFO 2/

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Armatures for analytical probes

Pressure Relief Valve DHV 718

Flamco Flamco-Fill STA Flamco-Fill STM

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

Pressure Reducing Valve

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

INSTALLATION, OPERATION

OPERATING INSTRUCTIONS

User's Manual. MixRite TF 10. Edition 05.08

UPGRADE KIT. Installs a new EAZY filter into Nexus 200 / 300 manufactured after 2006 and Nexus 210 / 310 manufactured after 2009

Genie Supreme Model 123 Installation & Operation Instructions

VALVES HIDROMATIC VALVE.

Ballorex Dynamic Description. Versions. Benefits. Balancing

RTD Temperature sensor TH11

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Siphon vessel / Priming aid

C 10 Pressure Reducing Valve

Regulators/valves Compressed air regulators Without filter

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Liquid level regulating valves Types PMFL / PMFH and SV

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

GAS PRESSURE CONTROL UNIT TYPE 132

Self-operated Pressure Regulators for special applications

200 / 300 Upgrade Kits

AVP-F. p setting range (bar) Code No. 003H6200

Chlorinator. MODEL C-731 (Floor Mounted)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Vetter Leak-Sealing Systems

Instruction presentation Special valves

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Relief Valve DHV 718

Operating Instructions

Combination Air Valve

ELADOS EDP L Diaphragm Metering Pump Type

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Pressure relief valve DHV 718

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Bermad Pressure Reducing. Model: 42T

UsER manual for Watersens ph -REDOX

swimming pool technology

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Pressure Reducing Valve DMV 750 set range: bar

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Installation, Operation, and Maintenance Manual

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

PRESSURE REGULATOR LBM SERIES

Y O U R W A Y IRRIGATION COMPONENTS. adritec.com

PRO SINK -R 1 and 2. Dilution system CONTENTS

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Chlorinator MODEL MK-I

Genie Supreme TM Model 123HP Installation & Operation Instructions

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Regulator from 1800 B series

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

CLASS TLP Pressure Reducing Valve

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

Operating Instructions Flowfit CUA252

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Pressure relief valve

D05T Compact Design Pressure Regulating Valves

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

GENERAL CATALOGUE 2O16

Diaphragm Pressure Keeping Valve

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Transcription:

Operating Instructions Predilution chamber 20687627EC BA 821C/24/ae/01.07

1 0 2 4 3 Predilution chamber DESIGN 1 Predilution chamber 1.1 Design A predilution chamber is optionally available for certain analyzers of Endress+Hauser Conducta GmbH& Co.KG, Division STIP. The chamber is mounted between the pipes of either of the sample processors PA-2 or PA-3. Utilisation of a predilution chamber enables the sample stream to be diluted at a constant rate between 1:3 and 1:100. In order to operate the chamber, a fresh water supply with a stable pressure from between 3 and 10 bar needs to be installed next to the analyzer. The predilution chamber consists of three components: pressure regulator (1) predilution chamber (2) double peristaltic pump head (3) 1 3 2 MV1 P1 MV3 MO MV2 MS P3 H3 PTFE P2 H1 MV4 H2 PA MAO Standard 1 Standard 2 Reagenz Reaktionslösung 1 6 10 13 The predilution chamber (1) is formed from a rectangle plexiglass body (8 x 5.50 x 5.50 cm). 2 6 7 4 8 14 9 Set into the chamber are: water inlet (3), sample inlet (9), sample outlet (14), sample overflow (10) and an injection cartridge screwed into the chamber (2) with a screwed-on dosage needle (8). The injection cartridge (2) is fitted-out with two seals (4, 6). 5 3 A drainage valve (11) is set into the underside of the predilution chamber to facilitate cleaning. 11 12 Endress+Hauser page 1

FUNCTION Predilution chamber 1.2 Function The sample is fed continuously into the chamber by the pump P1. At the same time, dilution water is injected into the fresh sample via the dosage needle. The diluted sample is then sucked out of the chamber by the double tube bed mounted on pump P1, and fed into the measuring chamber. Excess sample water is fed out of the predilution chamber and into the outlet via the sample overflow. Both stardard solutions and sample solutions (sample) can be diluted in this way. A constant rate of dilution is maintained throughout. The pressure regulator unit ensures that the water pressure at the water inlet to the chamber remains stable. The rate of dilution can be adjusted by varying the water pressure between 1.5 bar and 3 bar at the pressure regulator unit. The higher the pressure, the more dilution water is injected into the chamber. At a low pressure, less water is then injected in. The inner diameter of the dosage needle also influences the dilution factor, the various sizes suited to different applications are listed below (see also the spare parts order form) dosage needle ml/min at 1 bar ml/min at 2 bar ml/min at 3 bar transparent 9 18 27 red 17 34 51 orange 33.3 66,5 100 blue 47 94 141 mauve 75 150 225 pink 105 210 315 green 210 420 630 1.3 Technical data Dimensions : Water connection to the pressure regulator: Sample inlet: Sample outlet: Sample overflow: Adjustability of dilution factor: 8 x 5.50 x 5.50 cm G 3/4 thread 3-10 bar, stable tube int. d. 6 mm tube i.d. 4 mm tube Ø 6/8 pressure-free drainage 1:3 to 1:100 dependant upon the tube diameter and rotational speed of the pump P1 page 2 Endress+Hauser

Predilution chamber CLEANING 1.4 Cleaning It is recommended to clean the predilution chamber should dirt accumulate there. A procedural cleaning once a month should never the less be carried out. In order to do this, access the service program of the measuring unit. Press: CLEANING - BYPASS SCREEN E CLEANING BYPASS-SCREEN IS CLEANING FINISHED?? This display shows that operation has been entirely shut down for the duration of the maintenance task. Carry out the cleaning. TO QUIT Confirm only after the entire maintenance is completed. Close the valve on the pressure regulator; Place a receptacle under the drainage valve and open this to empty the dilution chamber; Unscrew and remove the injection cartridge from the chamber; Unscrew the dosage needle from the injection cartridge; Clean both the cartridge and the dosage needle; change the needle, if necessary; Clean the O-ring, change it, if necessary; Clean the predilution chamber; Place the dosage needle onto the injection cartridge and screw on tightly by hand; Every two months, unscrew the special nipple (5) from the water inlet (3) and check, if the sintered metal disc (7) contained within it is free from dirt. Should it be necessary, clean the disc with diluted hydrochloric acid and insert it back into the nipple. Screw the injection cartridge complete with dosage needle tightly by hand back into the predilution chamber. Finally, close the drainage valve. Open the valve on the pressure regulator. Confirm completion now with the Enter-key. The analyzer returns to OPERATION in the first stage of a measuring cycle with PAUSE VALUE. Endress+Hauser page 3

SPARE PARTS ORDER FORM Predilution chamber 1.5 Spare parts order form Use the appropriate column to fill out your order. Your order - amount - Part no. Description 9.007.77.07 Pressure regulator 9.007.77.08 Manometer 0 to +4 bar 6.010.23.05 Predilution chamber (1 fig.) 6.044.18.03 Plug for dosage needle (2 fig.) 6.011.18.04 Special nipple (3 fig.) 9.009.05.01 O-ring 11,.91 x 2.62 (4 fig.) 9.009.05.27 O-ring 9.75 x 1.78 mm EPDM (5 fig.) 9.021.05.28 O-ring 10 x 1.5 mm EPDM (6 fig.) 9.028.77.01 Filter disc (7 fig.) 9.023.21.06 Dosage needle 0.2 mm G½ transparent (8 fig.) 9.023.21.03 Dosage needle 0.84 mm G½ green 9.023.21.04 Dosage needle 0.58 mm G½ pink 9.023.21.05 Dosage needle 1.54 mm G½ olive 9.023.21.07 Dosage needle 0.2 mm G½ mauve 9.023.21.08 Dosage needle 1.4 mm G½ 9.023.21.09 Dosage needle 0.41 mm G½ blue 9.023.21.10 Dosage needle 0.34 mm G½ orange 9.023.21.11 Dosage needle 0.26 mm G½ red 9.022.06.08 PP screw-fitting DN 06/08 G¼ (10 fig.) 9.006.18.08 Mini ball-valve (11 fig.) 9.011.18.02 Screw-in nipple (12 fig.) 6.023.04.09 Luerlock screw-fitting (13 fig.) 9.011.06.05 PP screw-fitting 4 x 1 (14 fig.) 9.019.24.04 Tube Ø 9/12 mm fabric-reinforced. PVC 9.019.11.07 Tube Ø 6/8 mm PE transparent 9.019.11.12 Tube Ø 1.6 /4.8 EPDM ** 9.019.11.05 Tube Ø 2.4/5.6 EPDM ** 9.019.11.06 Tube Ø 3/5 EPDM ** 9.021.24.18 Tube Ø 4/6 mm EPDM ** 9.019.24.09 Tube Ø 6/10 mm PVC ** Please note that the specifications of your measuring unit will determine the tube diameter. Check which size your unit requires before you place your order. page 4 Endress+Hauser

USA Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Tel. 317-535-7138 Sales 888-ENDRESS Service 800-642-8737 Fax 317-535-8498 inquiry@us.endress.com www.us.endress.com Canada Endress+Hauser, Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 www.ca.endress.com Mexico Endress+Hauser México, S.A. de C.V. Av. Gustavo Baz No. 43 Fracc. Bosques de Echegaray Naucalpan de Juárez, C.P. 53310, Estado De México Tel. (52) 55-5371-1110 Fax (52) 55-5371-1128 mexico@mx.endress.com BA 821C/24/ae/01.07 2007 Endress+Hauser