VACUUM TESTING PRECAST CONCRETE MANHOLES

Similar documents
CLEANING, INSPECTION, AND TESTING OF SEWERS

SECTION PRESSURE TESTING OF PIPING

SECTION ACCEPTANCE TESTING FOR SANITARY SEWERS

Lecture Outline Chapter 15. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Chapter 15 Fluids. Copyright 2010 Pearson Education, Inc.

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Chapter 15 Fluid. Density

From and

Appendix C Field Testing of Pipelines

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

Design Data 22M. Flotation of Circular Concrete Pipe. w w I = w - x 1000 (3) (SG x 1000)

Gases and Pressure. Main Ideas

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

European Technical Standard Order (ETSO)

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Pressure Measurement

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

Pressure Measurement

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Gauge Pressure, Absolute Pressure, and Pressure Measurement

Using P-T Analysis As A Service Tool

Gas Physics Pressure and Flow Topics Covered:

WSC Performance Standard and Recommended Installation Procedures for Sanitary Water Well. Pitless Adapters, Pitless Units, And Well Caps


Gases and Pressure SECTION 11.1

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

Physics 221, March 1. Key Concepts: Density and pressure Buoyancy Pumps and siphons Surface tension

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

PRESSURE. 7. Fluids 2

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

EDCO VACUUM UNIVERSITY SECTION 18 VACUUM UNIVERSITY EDCO USA. 18:1

Worked Questions and Answers

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Fluid Sealing Association

The Discussion of this exercise covers the following points:

Alkylphosphines. Storage and Handling Recommendations

FIBERGLASS MANHOLES SANITARY SEWER LINES

Quick Reference Technical Data

Phys101 Lectures Fluids I. Key points: Pressure and Pascal s Principle Buoyancy and Archimedes Principle. Ref: 10-1,2,3,4,5,6,7.

Chapter 3: Fluid Statics. 3-1 Pressure 3-2 Fluid Statics 3-3 Buoyancy and Stability 3-4 Rigid-Body Motion

Chapter 12. Properties of Gases

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

Expansion Tank Design (Chilled Water)

PURPOSE OF THE POLICY

Liquids and Gases. 2/26/2012 Physics 214 Fall

Prof AH Basson, Pr Eng March Departement Meganiese en Megatroniese Ingenieurswese. Department of Mechanical and Mechatronic Engineering

Instrumentation & Data Acquisition Systems

Construction Dewatering

Exercises The Atmosphere (page 383) 20.2 Atmospheric Pressure (pages )

Unit A-2: List of Subjects

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Sizing Pulsation Dampeners Is Critical to Effectiveness

Limited quantities of compressed gases.

Perform Pressure & Leak Test, Tubing & Piping. Module 12306

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

CONTROL VALVE SEAT LEAKAGE

Air Eliminators and Combination Air Eliminators Strainers

Pressure and Depth. In a static, non-moving fluid

Section GATE VALVES

PUMP CONSULTING & TRAINING LLC Joseph R. Askew 1811 Stonecrest Ct. Lakeland, Fl

SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

Liquid Level Measurement

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

PHYSICAL FACILITIES Consultant s Handbook Division 33 Utilities 1300 Disinfecting Underground Potable Water Piping.

Operating Guidelines for PermSelect Modules Liquid Contacting

ConcepTest PowerPoints

WIKA INSTRUMENT CORPORATION

Guide for Evaluating Your Hose Assembly Supplier

OPERATIONS CHALLENGE 2017

BUTTERFLY VALVES Series 800

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

Chapter 3 PRESSURE AND FLUID STATICS

September 2018 Pressure Test

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

Cover Page for Lab Report Group Portion. Pump Performance

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Vapour pressure of liquids SURFACE TENSION

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

1 Exam Prep NSF/ANSI Tabs and Highlights

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

OCTOBER 2017 ISSUE Page 1 of 7

Transcription:

1 OF 5 testing is a quick, safe and practical way to validate manhole system integrity. Manhole sections can be tested at the precast concrete plant prior to delivery or on site prior to backfilling. Here you will find not only how to perform vacuum testing, but you will discover the benefits and limitations of vacuum testing as well. MEASURING PRESSURE Having a general knowledge and understanding of atmospheric pressure and hydrostatic pressure is essential when performing a vacuum test in the field. ATMOSPHERIC PRESSURE Atmospheric air, or the air we breathe, is a gas composed primarily of nitrogen molecules (80 percent) and oxygen molecules (16 percent) that are bound to the earth by gravitational forces. Atmospheric pressure is defined as the force per unit area exerted against a surface by the weight of the air above that surface. Thus the atmospheric pressure varies with altitude above the earth s surface. Atmospheric pressure at sea level is 14.67 pounds per square inch (psi). An alternative system of measurement (inches of mercury) is derived from the way in which atmospheric pressure is typically measured. If we insert one end of a vacuum-filled tube (see Figure 1) into a liquid and allow the liquid free access to the atmosphere, then the liquid will rise up the tube until the force exerted by the weight of the liquid column balances the atmospheric pressure. The denser the liquid used, the lower the height of the column. In initial experiments, liquid mercury (Hg) was used, and the corresponding column height was found to be 29.92 inches of mercury. (If water had been used, the column would be 408 inches 34 feet high.) The following relationships can be used to convert atmospheric pressure between the units of inches of mercury (in Hg) and pounds force per square inch of area (psi): GAUGE PRESSURE Most industrial gauges work on the Borden tube principal, which pressurizes a closed, curved tube and measures how much the tube tries to straighten out. The curved tube is surrounded by the atmosphere and therefore has 15 psi resisting the tendency to straighten. The gauge therefore measures the difference between the internal pressure trying to straighten the tube and the atmospheric pressure acting to resist the straightening. So if we read 35 psi on the gauge, there is really 50 psi being applied. Normally we do not take atmospheric pressure into consideration in our everyday lives, since it surrounds us uniformly and universally the same 15 psi exists internally as well as externally, creating a state of equilibrium as illustrated in Figure 2. However, to differentiate between the two measuring systems, we add the word gauge to measurements referencing atmospheric pressure as the zero point (i.e., psig) and the word absolute to measurements referencing full vacuum as the zero point (i.e., psia). Manhole Prior to Backfill Initially a manhole which has not been backfilled is uniformly loaded by atmospheric pressure (15 psia) on its interior and exterior, creating an equilibirum state. Mercury Barometer Atmospheric Pressure h = 29.92 inches at standard sea level pressure Atmospheric Pressure The liquid rises until its fluid pressure exactly balances the atmospheric pressure. No pressure is exerted on the top of the liquid in the column because of the vacuum, so the pressure in the column is just the fluid pressure, which is proportional to depth. 15 psia 15 psia 15 psia Manhole subjected to atmospheric pressure 15 psia uniformly loaded 3 3 5 psia 10 psia 15 psia Internal Pressure (absolute) psia Q U A L I T Y V A L U E P E R M A N E N C E

2 OF 5 HYDROSTATIC PRESSURE The pressure created by a fluid is a function of the fluid s unit weight and the height (h) of the liquid column above a reference plane. Water, for example, has a unit weight of 62.4 pounds force per cubic foot, which corresponds roughly to 0.43 psig per foot of water column height. The pressure created by a 23-foot water column is roughly 10 psi gauge (psig) or 25 psi absolute (psia). Following are a series of expressions that illustrate the relationship between the unit weight of water and its corresponding gauge pressure per foot of water column height and the example solution for the pressure created by a 23-foot water column. Test on Manhole Prior to Backfill -5 psig 10 in Hg 15 psia 15 psia 10 psia Example: 3 3 When a vacuum of 10 in Hg is drawn on a manhole; an internal pressure of roughly -5 psig, or 10 psia, is created. The atmospheric pressure on the exterior of the manhole (15 psia) will thus exert 5 psi differential pressure on all surfaces, joints and connectors. No other test method uniformly tests a structure in this way. 5 psia 10 psia 15 psia Internal Pressure (absolute) psia CREATING A VACUUM is defined as an absence of matter (molecules) in a defined volume of space. To produce a vacuum in the field we need to remove all the molecules of matter (air) from within an enclosed space (manhole structure). Initially a manhole which has not been backfilled is uniformly loaded by atmospheric pressure (15 psia) on its interior and exterior, creating an equilibrium state. To create a vacuum we use a pump, or venturi nozzle, attached to the manhole and attempt to suck out the air. It is almost impossible to produce a total vacuum. The closer we get to a full vacuum (29.92 inches Hg) the harder it gets to encourage the remaining molecules to leave. In reality all we do is create a partial vacuum (somewhere between 0 inches Hg and 29.92 inches Hg), which in turn creates a pressure differential between the partial vacuum inside the manhole and the atmospheric pressure pressing against the exterior of the manhole. WHEN TO VACUUM TEST? Many codes and specifications require that a vacuum test be performed after the manhole has been installed and backfilled. Testing after backfilling provides a degree of certainty that a watertight system has been installed. The major disadvantage is the fact that no industry standards exist for vacuum testing after the structure has been backfilled. Secondly, it is often difficult to determine the cause or locate and repair a system breech once the manhole has been backfilled. The resolution to this problem is to perform a vacuum test prior to backfilling and, if necessary, again after backfilling. See Appendix A: Suggestions for detecting leaks When a vacuum of 10 inches Hg is drawn on a manhole, an internal pressure of roughly -5 psig, or 10 psia, is created. The atmospheric pressure on the exterior of the manhole (15 psia) will thus exert 5 psi differential pressure on all surfaces, joints and connectors as illustrated in the following animation. No other test method uniformly tests a structure in this way.

3 OF 5 ASTM C1244 ASTM C1244, Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure () Test Prior to Backfill, has been developed to govern the proper vacuum testing procedure for testing concrete manholes. ASTM C1244 clearly states that a vacuum test is intended to be used as a preliminary test to enable the installer to demonstrate the condition of the concrete manhole prior to backfill. When utilizing ASTM C1244, a vacuum of 10 inches Hg is drawn on the manhole after all lift holes are plugged, and pipes entering the manhole are temporarily plugged and securely braced. The time is measured for the vacuum to drop to 9 inches Hg. The manhole is accepted if the measured time meets or exceeds the values presented in Table 1 of ASTM C1244. If the manhole fails the initial test, it may be repaired by an approved method until a satisfactory test is obtained. Note: The latest edition of ASTM C1244 shall be used for proper testing procedures and criteria. XYZ County specifications require that all manhole systems be vacuum tested in accordance with ASTM C 1244 requirements after backfilling. Manhole Diameter: 48 inches Manhole Depth: 30 feet Depth to Water Table: 8 feet Acceptance Test: ASTM C 1244* Resilient Connector: ASTM C 923** Depth to Connector: 28 feet * ASTM C 1244 requires a vacuum between 10 inches Hg and 9 inches Hg (-5 psig to -4.5 psig) be maintained for 74 seconds. ** ASTM C 923 requires resilient connectors to withstand a hydrostatic pressure of 13 psig when installed in a straight alignment and 1 when axial deflected 7 degrees. External Pressure at Critical Depth (Hydrostatic pressure) IN THE PRESENCE OF GROUND WATER testing after backfilling should be performed only after a successful non-backfill test has been completed in accordance with ASTM C1244. CAUTION: Many people do not fully understand the effects of vacuum testing backfilled manhole systems in the presence of ground water. testing backfilled manhole systems is not recommended, especially in the presence of ground water. testing a manhole system that is already subjected to hydrostatic pressure may exceed the design limits of critical flexible connectors leading to a system failure. If ground water is present, use the following information to determine if a reduction in vacuum pressure is warranted: Note: For simplicity, the effects of soil pressure are not taken into account in the following information and examples. In reality, the actual in-place loads may be greater when in-place soil conditions (effective stress) are taken into consideration. To determine the actual loads induced on a backfilled structure, use the following information in addition to the actual in-place soil properties to properly calculate the effective stress at the critical location. 1. Depth to water table 2. Pressure rating for flexible connector 3. Depth to bottom-most critical connector With this information, you can determine the theoretical in-place loads experienced by the deepest connector as outlined in the following example. If the combined pressure differential (vacuum and hydrostatic) between the interior and exterior of the manhole exceeds the connector s pressure rating, appropriate adjustments must be made. Test on Backfilled Manhole Already Subjected to Hydrostatic Pressure Note: Values are gauge pressure 3 2 3-5 psig 10 in Hg ASTM C923 pressure rating when pipe is axially deflected 7 = 10 psi 13.66 psig ASTM C923 pressure rating when pipe alignment is straight = 13 psi 5 psig 1 15 psig Pressure Differential at 28 feet below ground level (psig) Pulling 10 in Hg in the presence of 20 feet of hydrostatic head (8.66 psi) creates a pressure differential of 13.66 psi at that bottom most critical connector. 13.66 psi exceeds the ASTM C923 design limit of 13 psi for a straight alignment.

4 OF 5 Internal Pressure at Critical Depth ( pressure) Effects of Hydrostatic Pressure on a Backfilled Manhole Pressure experienced by ASTM C923 connector as groundwater table returns to normal level. below ground level 12' 1 2 24' 3 0 8.66 psig ASTM C923 pressure rating when pipe is axially deflected 7 = 10 psi ASTM C923 pressure rating when pipe alignment is straight = 13 psi 5 psig 1 15 psig External Hydrostatic Pressure (gauge) psig Hydrostatic Head (ft)* 12 13 14 15 16 17 18 19 20 21 22 Pressure (in Hg) 10 9 8 7 6 5 4 3 2 1 ** * Hydrostatic head above critical connector **At 22 feet below the groundwater table, the connector is naturally subjected to 9.5 psi Above Example Continued Using the recommendation above, the testing agency should draw only 2 inches Hg to prevent overloading the flexible connector as illustrated in Figure 3. External Pressure at Critical Depth (Hydrostatic pressure) Internal Pressure at Critical Depth (Adjusted pressure) Reduction -1 psig 2 in Hg Does the Pressure Differential Exceed the ASTM C 923 Pressure Rating? The combined vacuum test and in-place hydrostatic loads exceed the connector s pressure rating so appropriate adjustments must be made. ADJUSTING VACUUM PRESSURE Most flexible connectors have a pressure rating of only 10 psi when deflected, which is fairly common in a field installation; therefore we will use the more conservative 10 psi pressure rating as a base point. Drawing a vacuum of 10 inches Hg creates a pressure differential of 5 psi between the interior and exterior of a manhole system. A water column of 11.5 feet creates an additional 5 psi of external pressure. This ultimately creates a pressure differential of 10 psi at a connector located 11.5 feet under water when drawing a vacuum of 10 inches Hg. A conservative rule of thumb is to reduce the vacuum by 1 inch Hg for every 1 foot of hydrostatic head between 12 feet and 21 feet. A vacuum test should not be performed when the hydrostatic head exceeds 22 feet. 3 3 1 psi 9.67 psi ASTM C923 pressure rating when pipe is axially deflected 7o = 10 psi 5 psi 10 psi 15 psi By reducing the vacuum to only 2 in Hg, a pressure differential of 9.66 is created which is below the ASTM C923 limit.

5 OF 5 APPENDIX (SUPPLEMENTAL INFORMATION) A. DETECTING LEAKS: Prior to Backfilling: Leaks, though rare, can be readily detected by finding the source of the hissing sound as air enters the manhole. Leaks can also be detected by spraying water on the exposed wall surface infiltrating air will produce a dry spot. If the manhole fails the initial test, make repairs and retest until obtaining a satisfactory test. After Backfilling: Leaks can be detected by spraying a soapy solution on the interior of the manhole. Solutions of 2 to 10 ounces of liquid soap per gallon have been recommended for ambient temperatures below 80 degrees F (27 degrees C). A similar solution with a few ounces of corn syrup is recommended for temperatures above 80 degrees F (27 degrees C). Bubbles will form at leaks. If the manhole fails the initial test, make repairs and retest until a satisfactory test is obtained. When adequate repairs cannot be made from the interior, exterior repairs should be made by means of excavation. B. STAND PIPES: The presence of ground water near a manhole can have a significant effect on the performance of a manhole system during a vacuum test as outlined above. To avoid damaging the installed system, an accurate measurement of the water table is required to account for hydrostatic loads. Install a stand pipe alongside the manhole stack during the backfill process. Once dewatering operations cease and the water table stabilizes, measure the water level by lowering a chain or measuring tape into the stand pipe. C. PRESSURE RATINGS: ASTM pressure ratings shall be used unless the manufacturer provides sufficient data indicating a higher rating. ASTM C 923, Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes and Laterals This specification covers the minimum performance and material requirements for resilient connectors used for connections between reinforced concrete manholes conforming to Specification C478 and pipes, between wastewater structures and pipes, and between precast reinforced concrete pipe laterals. ASTM C 1478, Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipe, and Laterals This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. This specification requires that resilient connectors withstand 6 psi of hydrostatic pressure for straight and axial deflected pipes and laterals. D. OTHER TEST METHODS Prior to the introduction of vacuum testing, manholes were typically tested for watertightness in accordance with: ASTM C 969, Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines ASTM C 924, Standard Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method ASTM C 969 may take up to 72 hours or more to complete, while ASTM C 924 presents a potential safety hazard if the line is not prepared properly and if procedures are not followed. Test pressures must also be adjusted to account for groundwater tables when using ASTM C 924 with a maximum testing limit of 5 psi gauge pressure, in which case ASTM C 969 is to be used. ASTM C 969 also has limitations in the fact that the structure is not uniformly tested. DISCLAIMER The above information is intended solely for use by professional personnel who are competent to evaluate the significance and limitations of the information provided herein, and who will accept total responsibility for the application of this information. The National Precast Concrete Association (NPCA) disclaims any and all responsibility and liability for the accuracy and application of the information. This specification requires that resilient connectors withstand 13 psi of hydrostatic pressure for straight aligned pipes and 10 psi of hydrostatic pressure for axial deflected pipes and laterals.