Water Regulator Adjustment Service Quick Reference Card

Similar documents
Operation Manual Piston Sensed Gas Pressure Regulators

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

OPERATING AND MAINTENANCE MANUAL

Your safety and the safety of others are very important.

MANUAL BE SERIES Test Benches

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

ACCESSORY KIT INSTALLATION MANUAL

Natural Gas to L.P. Gas Conversion Kit

Advanced Fluid Handling Cart Owner s Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Natural Gas to L.P. Gas Conversion Kit

WW-730. Pressure Sustaining/Relief Control Valve

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

Natural Gas Conversion Kit

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Pressure Dump Valve Service Kit for Series 2300 Units

G96 Series BASOTROL Dual Operator Valve

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Gas Conversion Kit Pilot Ignition Heaters

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

User Instruction Manual

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Operator: Save these instructions for future use!

Universal Valve Company Inc

Universal Valve Company Inc

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

PAPR Flow Tester. instructions. part no WARNING

Types 749B and R130 Changeover Manifolds

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

The FixIt Manual Chapter 14

NGP-250/500 Nitrogen Generator Quick Start Guide

TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL. This manual contains;

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

Freedom8 ShoeBox Compressor Manual

INSTALLATION GUIDE Gas Rangetops

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Dump Valve Service Kit for Series 3000 Units

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

49004 Relief Pressure Check Kit for H8508 Series and HW1 Series Impact Wrenches

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Installation Instructions

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Installation and commissioning instructions 255 series and 256 series

GM-7000 Series CE Approved Gas Control Valve

Natural Gas Conversion Kit

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

OPERATION MANUAL NTF-15

WW-720. Pressure Reducing Control Valve

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

ELECTRONIC PLC SERIES Test Benches

installation instructions

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

G92 Series BASOTROL Automatic Pilot Gas Valve

Pressure Regulators. Operating Instructions. Instrumentation

Installation, Operation, and Maintenance Manual

Retractable Hose Reel with 3/8" x 50' PVC Hose

Installation Instructions For Natural Gas Conversion

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Operating Instructions Model and Hydrostatic Test Pump

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

INSTALLATION INSTRUCTIONS

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

RADROVER REAR RACK INSTALLATION MANUAL

FX IMPACT OWNER S MANUAL

GM Series Dual-Block Multi-Function Gas Control Valves

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

WW-720. Pressure Reducing Control Valve

SUMMITTM 475 & 675. Natural Gas Barbecues. Step-By-Step Guide THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

KJ4000 Operating Instructions & Parts Manual NSN

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

Warning: NEVER ALTER TEST EQUIPMENT

Operating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)

BGC258 Series BASOTROL Gas Valve

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

JACKSON GRILLS PATIO FIRE

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TECHNICAL DATA CAUTION

Cat #: 7310SB UPC #: Spec:

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

RG3100 and RG3100Ice Regulator System

ACCESSORY KIT INSTALLATION INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Installation Instructions

Transcription:

Models SSPG14 & SSPE14 Pasta Water Regulator Adjustment Technical Service Installation & Set Up Instructions Please read complete instructions prior to starting. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE This installation should be performed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, property damage, personal injury or loss of life may result. The qualified service agency is responsible for the proper installation of this assembly. This installation is not proper and complete until the operation of the appliance is checked as specified in the manufacturer's instructions. The power supply to the appliance MUST be disconnected before performing this procedure. Ensure that the gas supply to this appliance is turned off before performing this procedure. Use only parts supplied with the appliance. Use of any parts other than those supplied will void the warranty and could cause unsafe conditions or improper operation of your appliance. Drain the tank and ensure that appliance has cooled to room temperature before performing this installation. DO NOT work on a hot appliance or an appliance containing hot cooking medium; serious personal injury may occur. Adequate means must be provided to limit the movement of this appliance without depending on the gas line connection. If any restraining devices are disconnected during this procedure, ensure that they are reconnected before putting the appliance into service. Failure to do so could result in a dangerous and unsafe condition. 1 L80-101 Rev 0, November 2011

NOTE: If you have any questions about this procedure please call Pitco at (603) 225-6684 and ask for the Technical Service department. Follow these steps to adjust the water regulation system to the models shown. This procedure should be performed by an Authorized Service Agency. IMPORTANT! Some parts or accessories may need to be removed to perform this procedure. When completed, all parts and accessories must be reinstalled onto the appliance. 2 L80-101 Rev 0, November 2011

Tools Recomended for this Adjustment Tool Legend 1)- 7/16", 13/16", 3/4" & 7/8" Assorted Wrenches 2)- Flatblade Screwdriver 3)- 1/2 Gal. Pitcher, Or Larger 4)- Stopwatch Parts List A)- 1/2" or 3/8" NPT water connection B)- Needle Valve C)- 0-60 PSI Regulator D)- 0-15 PSI Pressure Gauge Regulator Assembly pictured above is located inside of the cabinet. The water connection, (A), is located at the rear of the cabinet. Models with 2 or more units may have a manifold assembly installed. 3 L80-101 Rev 0, November 2011

1 Water Regulator Adjustment IMPORTANT- When installing multiple Units, Use the assembly packed with the appliance to keep mating parts together. Make the Hot water connection for the cooker and then follow the steps to adjust the water flow at the mixing valve. The flow will be full on for the fill knob, and 1/2 Gal. per minute on the cook reheat knob. 2 The components, Needle Valve (B), Regulator (C), and Pressure Gauge (D), are located just inside the rear bottom brace of the unit. Sufficient water line will be needed to access the components and check the water flow as the unit will need to be pulled away out from the normal operating position. The needle valve, (B), should have been preset at the factory but if adjustment is required follow the additional steps in these instructions, or contact the factory. 4 L80-101 Rev 0, November 2011

3 Prior to turning on the water supply, ensure that both control knobs on the mixing valve are in the closed position, and the regulator is set to No Flow. To close the mixing valve, turn both knobs CW until they stop. To set the regulator to No flow, loosen the locknut, (C2), and do not retighten at this time. Turn the adjustment screw, (C1), CCW to release pressure on the regulator spring, Do not allow the screw to come completely out of the regulator. 4 Open the pressure gauge vent, (D1), and turn on the water supply to the appliance to set the water pressure to 10 PSI. To set the water pressure, turn the adjustment screw,(c1), on the regulator CW until the indicator on the gauge is pointing to 10. Check for any water leaks and repair as needed prior to continuing. The flow of the Cook/Reheat water line needs to be set to 1/2 Gal./Min. at this time. Ensure the tank drain is closed, then fully open the Cook/Reheat knob by turning it CCW until it stops. Water should be flowing into the tank, and the pressure reading on the gauge should drop to about 6 PSI. 5 5 L80-101 Rev 0, November 2011

6 7 With the water flowing, adjust the regulator screw, (C1), until the pressure is 6 PSI on the pressure gauge. Then use the graduated pitcher to measure 1/2 gal. of water into the tank. The allowable time to measure the 1/2 gal. of water is 50-70 secs. If the required flow is not achieved in this time frame adjust the regulator +/- 1 PSI as needed and recheck until the flow is correct. Once the flow is correct, retighten the locknut, (C2), on the regulator. Additional Step if required NOTE: If the needle valve requires adjustment it is important to maintain the regulator pressure setting of 6 PSI +/- 1 PSI while water is flowing. If you cannot get the required flow with adjusting the regulator +/- 1 PSI, you can adjust the factory preset needle valve, (B). Adjust the needle valve by loosening the locknut, (B2), and turning the valve knob, (B1), CW to decrease flow, or CCW to increase flow. Adjust the needle valve no more than a 1/4 turn at a time. Measure the flow after each adjustment. Tighten locknut after adjustment is completed. N o t e : When the desired water flow is achieved, reinstall any parts that were removed during the procedure and finish installing the appliance in accordance with the operations and service manuals. 6 L80-101 Rev 0, November 2011