LEVEL 3 CERTIFICATE IN AUTOMATIC TURF IRRIGATION SYSTEMS ASSESSMENT SCHEDULE

Similar documents
LEVEL 2 CERTIFICATE OF COMPETENCE IN THE SAFE USE AND OPERATION OF MOBILE ELEVATED WORK PLATFORMS

LEVEL 2 CERTIFICATE OF COMPETENCE IN CHAINSAW AND RELATED OPERATIONS ASSESSMENT SCHEDULE

LEVEL 2 CERTIFICATE OF COMPETENCE IN THE SAFE USE OF MOWERS ASSESSMENT SCHEDULE

CERTIFICATE OF COMPETENCE

LEVEL 3 NPTC CERTIFICATE OF COMPETENCE IN THE THOROUGH EXAMINATION OF ARBORICULTURAL EQUIPMENT. ASSESSMENT SCHEDULE (Revised Aug 2010)

LEVEL 2 CERTIFICATE OF COMPETENCE IN FOREST MACHINE OPERATIONS ASSESSMENT SCHEDULE FMO4 SKIDDING

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

LEVEL 2 AWARD IN CHAINSAW AND RELATED OPERATIONS (QCF)

LEVEL 2 AWARD IN CHAINSAW AND RELATED OPERATIONS (QCF) CS34 - Sever Individually Uprooted Trees (Pre requisite: CS30, CS31 and CS32)

LEVEL 2 AWARD IN CHAINSAW AND RELATED OPERATIONS (QCF) CS38 - CLIMB TREES AND PERFORM AERIAL RESCUE ASSESSMENT SCHEDULE

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS

Code AWC20HP Air Compressor

Irrigation System Winterization and Pressurization Procedures

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

Manual Actuated Boiler Blowdown Valves

LEVEL 3 NPTC CERTIFICATE OF COMPETENCE IN THE THOROUGH EXAMINATION OF ARBORICULTURAL EQUIPMENT

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

COUNTER CURRENT UNIT. Instruction Manual

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Valves. Controllers. Valves Two Types

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Winter Shut Down Procedure

6900 Maintenance Instruction System Flush

CITY & GUILDS LEVEL 2 AWARD IN SIT ASTRIDE ALL TERRAIN VEHICLE HANDLING QAN 600/4957/1

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

22. Specialty Valves.

Adjustable. Unloader Valve. O&M Manual. Part #

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

JET Mini Mechanical Pressurisation Equipment

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transferring and Storage

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

HOW TO PLAN AN UNDERGROUND IRRIGATION SYSTEM

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Method Statement: Testing Dry Riser System

CONSIDERATIONS FOR THE USE OF SEA WATER IN FIREFIGHTING. Prepared and Presented by Lenny Naidoo (Chief Fire Officer), Engen Petroleum Company

Installing ASI Umbilical Delivery Systems

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Emergency Shower & Eyewash. Training Guide

Deluge Optimo Shower valve and kit 10032CP

OWNER S TECHNICAL MANUAL

JORDAIR/BAUER Service Manual

TECHNICAL DATA. Q= Cv S

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Underground irrigation

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Driver Operator Pumps: Basic Pump Operations

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

POOL ROVER ST POOL CLEANER Installation Instructions

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Q = C v P S

641/01 AVK SWING CHECK VALVE OPERATION & MAINTENANCE MANUAL. AVK UK Limited OM270710

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

MODEL NUMBER: P PORTABLE COMPRESSOR

ML3M Monnier Miniature Compressed Air Lubricator

General maintenance engineering applications

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Series 58 SAFETY VALVES 312

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

Rapidmain Installation Guide

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

TSS21 Sealed Thermostatic Steam Tracer Trap

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Operating Procedure TITON SUBSEA BOLT TENSIONER

100C Air Compressor Kit

Working Environment Safety Assessment

Duplex Commercial Softeners

Copyright, 2005 GPM Hydraulic Consulting, Inc.

System Pressure Manager Standard & System Pressure Manager Plus

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

Dual Solenoid Gas Valve Installation

APG001. Application Guide for Gas. T: F: E:

Level 3 Diploma in Moving Loads in Construction. Qualification Specification

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

PV4 and PV6 Piston Valves

Transcription:

NPTC Registered Charity No. 1096429 STONELEIGH PARK, WARWICKSHIRE CV8 2LG Tel: 024 7685 7300 Fax: 024 7669 6128 Email: information@nptc.org.uk LEVEL 3 CERTIFICATE IN AUTOMATIC TURF IRRIGATION SYSTEMS ASSESSMENT SCHEDULE 1

Candidate Information Introduction The scheme will be administered by the NPTC. NPTC will: Publish scheme regulations assessment schedule assessment material Approve centres to co-ordinate and administer the scheme Set standards for the training of Verifiers and Assessors Recruit, train and deploy Verifiers Manage verification Issue certificates to successful Candidates The Certificate Certificates will be awarded to Candidates who achieve the required level in all Units. Instruction Attendance at a course of instruction is not a pre-requisite for an application for an assessment but potential Candidates are strongly advised to ensure that they are up to the standards that will be expected of them when they are assessed. NPTC does not hold a register of instructors; however instruction will normally be available from recognised training providers and/or centres of further or higher education active in the areas covered by this certificate. Further information on training may be obtained from the local Assessment Centre. Access to Assessment Assessment Centres will be responsible for arranging assessment on behalf of a Candidate. Assessment may only be carried out by an Assessor approved by NPTC for that scheme. Under no circumstances can either instructors involved in the preparation of candidates, or the candidates work place supervisors, or anyone else who might have a vested interest in the outcome, carry out the assessment. The minimum age limit for Candidates taking certificates of competence is 16 years. There is no upper age limit. Assessment The assessment, taken in the form of a written question paper, is a process by which it is confirmed that the Candidate is competent in the Units within the award to which the assessment relates. It is a process of collecting evidence about his/her capabilities and judging whether that evidence is sufficient to attribute competence. The candidate must be registered through an NPTC approved Assessment Centre for this qualification prior to assessment. The result of the assessment will be recorded on the Candidate Assessment Report Form. The schedule of assessment contains the criteria relating to assessment of knowledge and understanding A list of registered Assessment Centres is available from NPTC. (www.nptc.org.uk) Verification Verification is a process of monitoring assessment; it is an essential check to confirm that the assessment procedures are being carried out in the way that NPTC has laid down. The overall aim of verification is to establish a system of quality assurance that is acceptable in terms of both credibility and cost effectiveness. A selection of written papers marked by the Assessor will be evaluated by an NPTC approved Verifier. Compliance with the verification requirements will be a pre-requisite of Assessors remaining on NPTC s list of approved assessors. Complaints and Appeals NPTC and its Assessment Centres have a formal Complaints and Appeals procedure. In the event of any dissatisfaction with the arrangements and conditions of assessment, the candidate should first contact the Assessment Centre through whom the assessment was arranged and submit the complaint in writing. For further information on NPTC's Equal Opportunities Policy and Complaints and Appeals Procedures, please refer to www.nptc.org.uk 2

Learning Outcomes The candidate will be able to demonstrate knowledge: 1. Of the function of various component parts of an irrigation system 2. About the different features found in sprinkler heads and what advantages found 3. Of the function of solenoid valves, their various features and how they fit into the control system 4. About the potential sources of water and appreciate the regulations covering its use. 5. About the various control system component parts associated with irrigation systems and the efficient use of water 6. On common types of pipe material used in irrigation systems. Methods for joining them. Precautions that must be taken to protect underground pipe work. Function of associated valves and pipe fittings found in a typical irrigation system 7. Of the procedure to undertake simple fault finding 8. About the typical procedure for winterising and opening up irrigation systems 9. Of potential hazards associated with irrigation systems In addition candidates will also be able to calculate: 10. Run times for sprinkler from information obtained from precipitation rates for sprinklers 11. Precipitation rates Assessment takes the form of a written question paper to establish knowledge and understanding. Guidance Notes for Candidates and Assessors The assessment contains 4 compulsory units: The compulsory units are: Unit 1. Component parts of an automatic irrigation system Unit 2. Environment, water and its efficient use Unit 3. Precipitation rate and run time calculations Unit 4. Safe Operation and Maintenance of Turf Irrigation Equipment Candidates must successfully achieve all Assessment Activities. Additional Information: May be sought from the relevant Health and Safety (HSE)/BTLIA publications. 3

Unit 1: Component parts of an automatic irrigation system ASSESSMENT ACTIVITES 1. Demonstrate knowledge of the function of various component parts of an irrigation system taking into account Triple swing joints Solenoid valves. Items in a valve box associated with a golf green, tee or sports area Isolating valves Where isolating valves are likely to be found Air release valves and where they may be found Equipment that might be found in a pump house One way valve To apply water evenly to a specific area To enable the sprinkler to be moved up or down so that it is a grade level To protect the lateral pipe work below from heavy weights To turn off or on the water to the sprinklers remotely via an electrical current To enable the pressure at the sprinkler to be adjusted by using flow control Control maximum pressure when they are pressured regulated Solenoid valve(s) Decoders Hose point Isolating valve Turn water off to enable servicing of sprinklers or solenoid valves Enable leaks in pipe work to be located Enable pipe work to be repaired Used to enable commissioning of a system Used to drain the system Found in Greens valve boxes Found in 'Tee' valve boxes Found around the course especially at junctions in pipe work Found in Pump Houses Found in mains water supplies To enable air to be released from the highest points in the system Irrigation pump(s) One way valves/non return / check valves Pressure relief valve Pressure gauge Isolating valves Controller To protect the pumps against reverse rotation To help maintain pump prime 4

ASSESSMENT ACTIVITES 2. Demonstrate knowledge about the different features found in sprinkler heads and what advantages found taking into account: Sprinkler head delivery mechanisms Impact drive Gear Cam Crown Piston Two Pass Ball Dolphin Sprinkler head Sprinklers with low drainage check valve Pressure regulation sprinklers Digging around a V-I-H sprinkler head 3. Demonstrate knowledge of the function of solenoid valves, their various features and how they fit into the control system taking into account: BSP/ACME Adaptor PTFE Tape Alternatives to a V-I-H system Operating a solenoid valve Flow control wheel Pressure regulated solenoid valves Minimum solenoid coil voltage If a solenoid coil is working Have pressure control Have low drainage check valve Prevents the water from high sprinklers flowing to lower situated ones Limits the maximum nozzle pressure Ensures even nozzle pressure across the course Small bore pipe between the bottom valve and solenoid control Low voltage control cable a) enables BSP & ACME threads to be joined together b) enables a water tight threaded joint to be made. Block Split Block Using an external bleed screw. Rotate external cam through 90º Rotate coil through 90º Can be used to reduce the flow and hence reduce the nozzle pressure Accurately limits the maximum nozzle pressure. Ensures even nozzle pressure across the course 19 volts approximately Check the electrical resistance [12-50Ω] Check using a coil tester 5

Unit 2: Environment, water and its efficient use ASSESSMENT ACTIVITES 1. Demonstrate knowledge about the potential sources of water and appreciate the regulations covering its use taking into account: The Environment Agency Using mains water Restrictions that might be applied to the use of water Sources of water Prevention of contamination of mains water supplies 2. Demonstrate knowledge about the various control system component parts associated with irrigation systems and the efficient use of water taking into account: Low voltage control cable Maximum usable cable voltage The decoder The controller Sensors associated with the control system The action to take if precipitation rate is higher than infiltration rate To control the efficient use of water To manage the resource efficiently for all The water is clean, free from contamination both chemical and organic and has known ph No large scale storage facility is required Amount abstracted Time of year for abstraction and cost Limited use in drought Rivers Streams Wells Bore holes Springs Lakes and ponds Grey water Gap not less than 20mm and at least twice the size of the bore of the inlet pipe Use of back flow devises To transmit an electrical current sufficient to operate the solenoid coil To transmit the control signal to the decoder 50 volts Receive the control signal to switch on or off the solenoid coil Controls the time the sprinklers are operational In none pressurised system, the controller will switch on or off the pumps Low level water switch Rain switch High wind switch Sustained low pressure switch Low sensor Pressure switches Flow sensor Apply the water in multiples of smaller run times Immediate operational action to take if excessive wind speeds encountered Location of control cable Turn the system off Just above the pipe work 6

Unit 3: Precipitation rate and run time calculations ASSESSMENT ACTIVITES 1. Calculate the precipitation rates taking in to account: Square spaced sprinklers spaced at 20 metres and a flow of 100 litres/minute and with a 360º rotation Row space for a triangular configuration if the head space is 18metres 15mm/hr 18 x.866 = 15.58 Maximum head space according to BTLIA Standards for triangular spacings for 5 mph wind speed when the sprinkler data states that the radius of throw is 20metres The formula to enable the precipitation rate for an in-line configuration to be calculated at 360º rotation 20 x 2 x 55% = 22metres l/m x 60 = mm/hr HS x [HS x 2 x 866] Standard % diameter spacings for square and triangular configurations for wind speeds up to 5mph Precipitation rate for triangular sprinklers at 55% of radius of 18metres and a flow of 80 l/m full circle Square 50% of diameter Triangular 55% of diameter HS = 18 x 2 x 55% = 19.8m RS = 19.8 x.866 = 17.1 m 80 x 60 = 14.2 mm/hr 19.8 x 17.1 Precipitation rate for 90º rotation for a sprinkler that has a precipitation rate of 10mm/hr full circle Action needed to counter wind speeds above 5mph during the design stage Maximum wind speed that irrigation should not take place 2. Calculate the run times for sprinkler from information obtained from precipitation rates for sprinklers taking in to account: The run time if the precipitation rate is calculated at 14mm/hr, full circle and the required precipitation is 25mm/week The run time if the precipitation rate is calculated at 30mm/hr, half circle and the required precipitation is 25mm/week The run time if the precipitation rate is calculated at 10mm/hr, full circle and operates at 90º part circle and the required precipitation is 17mm/week 40mm/hr Reduce the head speed by 5% per 5 mph 15 mph 25/7 x 60 = 15.3 mins [15 mins] 14 25/7 x 60 = 7.1 mins [7 mins] 30 Precipitation rate 10 x 4 = 40 mm/hr 17/7 x 60 = 3.6 mins [4 mins] 40 7

Unit 4: Safe Operation and Maintenance of Turf Irrigation Equipment ASSESSMENT ACTIVITES 1. Demonstrate knowledge on common types of pipe material Clean pipe of dirt etc. and cut to length and remove burrs used in irrigation systems. Methods for joining them. Apply cleaner to pipe and fittings Precautions that must be taken to protect underground pipe Apply cement to pipe and fittings using correct techniques. work. Function of associated valves and pipe fittings found in a Push home pipe fully to pre marked position and hold firm for one minute typical irrigation system taking into account: Remove excess cement from joint Allow time to cure according to recommendation The pocedure for making a upvc cement joint Advantages for using upvc pipe work Advantages for using MDPE pipe Advantages for using HPPE pipe Methods of joining PE pipe work together Minimum depth for mains pipe work to meet the water bylaws BTLIA recommended minimum depth of cover for mains and lateral irrigation pipe work Wide range of pipe fittings available Does not corrode but joints may age. More flexible which is better in unstable ground conditions More reliable quality joints More resistant to damage Thinner walled pipe capable of carrying more water for the same OD Electrofusion Butt weld Mechanical joint 650mm cover 450mm cover Initial installation angle of the long arm of a triple swing joint 45º Method of checking air release valves during refilling Drain down valves and where they may be found Position and function of one way /non return /check valves in a complete system Air should be heard escaping from the valve Found at the end and lowest points in the pine work system Enables water to be removed from the pipe work for repairs to be carried out Enables water to be removed from the pipe work to prevent frost damage Prevents water flowing back to source Prevents from contra rotation on switching off Found at the bottom of lift suction pipes After each pump Before the water leaves the pump house Hose points For hand watering Hose points breaking off. High pressure water 2. Demonstrate knowledge of the procedure to undertake simple fault finding taking into account: Pipe leaks Isolating valves Position of mains and sub main pipe locations Cable faults Pressurise system, switch off and check the pressure gauge drop with time Check each section of pipe between isolating valves for pressure drop Use a 'CAT' type cable locator assuming cable laid with pipes Check the controller for cable fault test facility Use cable fault test equipment 8

ASSESSMENT ACTIVITES 3. Demonstrate knowledge about the typical procedure for winterising and opening up irrigation systems taking into account: Storage tanks Frost and mechanical damage Mains and lateral pipe work Damage from frost if not drained down correctly Refilling pipe work Operation of sprinklers Effect of jet of water issuing from a nozzle if very low pressure Appearance of jet of water issuing from a nozzle of over pressurised 4. Demonstrate knowledge of potential hazards associated with irrigation systems taking in to account: Making solvent joints for upvc pipe Incorrect refitting of sprinkler snap rings Removing the bottom valve in V-I-H sprinklers Advice prior to working in trenches or holes Working near mains voltage electrical equipment with water present Pointing jets of water towards overhead electrical cables Aluminium pipes close to overhead power lines Turn of water supply Lower water level Place slab of polystyrene into tank Check tank roof for leaks and tightly fitted Remove drain plug and drain Electrically isolate the pump motors Consider artificial heat from thermostatically controlled heater Open drain valves Open hose points slightly to allow air into the system Blow out water with compressed air Damage to: Pumps Pressure relief valves Pressure switches Pipe work Solenoid valves Sprinkler heads Air release valves Fill slowly and remove air Sprinkler rise and fall Sprinklers rotate at an even rate Sprinklers are rotating to the correct arc The arc settings are correct That there are no leaks The water issuing from the nozzles look similar Check the radius of throw Produces a donut effect Generates a lot of mist and has reduced throw Working in confines space with insufficient ventilation when handling cleaner and cement Protect hands from cleaner and cement Sprinkler head drive mechanism blowing out of the ground Isolate the sub main and reduce pressure in the sub main Follow HSE Guide Lines Isolate electrical equipment Avoid spraying water in a pump house Electrocution Electrocution 9