Elcometer Viscosity Cup. Operating Instructions

Similar documents
Elcometer ISO Groove Depth Checker. Operating Instructions

Elcometer 123. Surface Profile Gauge. Operating Instructions

Elcometer 125. Surface Profile Comparator. Operating Instructions

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Elcometer 2300 Rotational Viscometers. elcometer.com

Standard Test Method for Viscosity of Paints and Related Materials by ISO Flow Cups 1

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

Rotary Viscometers Rotary viscosimeters ST-2020

Elcometer 406L. Statistical Glossmeter. Operating Instructions

STARLOG. Capacitive Water Depth Probe

BS ml Bottle Sampling Unit

Pneumatic service kit Model CPG-KITP

SITRANS P measuring instruments for pressure

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

H&D Fitzgerald Pressure Pyknometry System Mark 5

BD Cytopeia Fluidic Kit User s Guide

VLI Visible Level Interface Operation & Maintenance Manual

Peak Pressure Indicator MSI-3

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

AUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed

Fungilab s new branch in New York (US)

Fungilab s new branch in New York (US)

How to specify a product. Process Sensors and Mechanical Instruments

ST 18 Aluminium Gas Model

Alpha Series. Main Features > Data displayed Selected speed r.p.m Selected spindle SP

ST 18 Aluminium Gas Model

GMC-I Service GmbH Calibration Center

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Tensiometer For the measurement of surface and interfacial tension

CalCheck. Instrument User Manual V1.8

Constant Pressure Crude Oil Container Model CPCCP

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Hydraulic hand test pump Models CPP700-H and CPP1000-H

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Propor tional Re lief Valve s

SV60 Safety valves. for use with steam, gas and liquids

Proportional Relief Valves

130 SSP Soluble Salt Profiler

User Manual PTW-DensiX. D / Di/Zi

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pressure Automated Calibration Equipment

Model Visit our website at:

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Spindles AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.

ISO INTERNATIONAL STANDARD. Steel wire ropes for the petroleum and natural gas industries Minimum requirements and terms of acceptance

STAG. Balancing valves Balancing valve with grooved ends DN

ISO 2503 INTERNATIONAL STANDARD

Product Catalogue. P-SERIES Pressure Gauges

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

O NEof Premium tools for professionals!

Tensiometer For the measurement of surface and interfacial tension

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Transferpette -8/-12

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

The temperature gradient plate consists of a high precision chromium measuring plate, with equispaced temperature sensors beneath the surface.

Self-operated Pressure Regulators for special applications

Digital pressure gauge Model CPG500

TEST SPECIFICATION NYT-909-C

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Installation, Operation, and Maintenance Manual

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Contents. 1. Non Destructive Testing Requirements. 2. Non Destructive Testing Methods Magnetic Particle Examination

GA24 Technical Datasheet

SNOW PICKETS` Climbing and Mountaineering Equipment. Foreword

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Installation, Operation, and Maintenance Manual

BDT20 Safety process pressure gauge 100 & 160mm

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Digital Melting Point Apparatus

PM105 PRESSURE METER USER S MANUAL

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

INTERNATIONAL STANDARD

Liquid level instruments BM 24 /BM 51

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

A REFERENCE GUIDE FOR REQUALIFICATION OF GAS CYLINDERS

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Oxygen Dialflow Meter. Instructions for Use

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Easy with a modular concept for future expansion

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

GETREN P Sliding Agents for Window Profiles. Sept 2014

Installation, operating and maintenance Instructions for Seemag bypass level indicator

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

Elcometer 2350 2351 2352 2353 2354 English Viscosity Cup Operating Instructions

English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2009/2010. All rights reserved. No part of this Document may be reproduced, transmitted, transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of Elcometer Limited. A copy of this Instruction Manual is available for download on our Website via www.elcometer.com. Doc.No. TMA-0318 Issue 05 Text with Cover No: 19334

CONTENTS Section Page 1 About your viscosity cup.......................................................... 2 2 Taking a reading................................................................. 4 3 Storage......................................................................... 7 4 Technical specification............................................................ 7 5 Maintenance.................................................................... 8 6 Accessories..................................................................... 9 7 Certification..................................................................... 9 8 Related equipment.............................................................. 10 9 Viscosity standard oils........................................................... 11 10 Elcometer viscosity cups......................................................... 12 1

Thank you for your purchase of this Elcometer Viscosity Cup. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply of inspection equipment for coatings and concrete. Our products cover all aspects of coating inspection, from development through application to post application inspection. This Elcometer Viscosity Cup is a world beating product. With the purchase of this Viscosity Cup you now have access to the worldwide service and support network of Elcometer. For more information visit our website at www.elcometer.com 1 ABOUT YOUR VISCOSITY CUP Elcometer Viscosity Cups are easy-to-use gauges for measurement of viscosity of liquids. The cup is supported in a stand and is filled with the liquid to be measured. The time taken for the liquid to drain through an orifice in the bottom of the cup is measured. The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cst). A wide range of cups with different orifices is available for measurements between 5 cst and 5100 cst. 1.1 THESE INSTRUCTIONS These instructions describe the operation of the following Elcometer Viscosity Cups: Elcometer 2350: DIN Elcometer 2351: FORD ASTM Elcometer 2352: AFNOR NFT Elcometer 2353: ISO, DIN, NF, NBN, ASTM Elcometer 2354: BS 2

1.2 STANDARDS The Elcometer Viscosity Cups can be used in accordance with a wide range of National and International Standards. For full details of which standards are appropriate see Elcometer viscosity cups on page 12. 1.3 WHAT THE BOX CONTAINS Elcometer Viscosity Cup Operating instructions Storage case The Elcometer Viscosity Cup is packed in a cardboard and foam package. Please ensure that this packaging is disposed of in an environmentally sensitive manner. Consult your local Environmental Authority for further guidance. 1.4 CAUTION Take care to avoid damaging your viscosity cup. Damage to the orifice, scratches on the internal surface or deformation of the cup will affect the readings and the gauge may have to be replaced. 3

2 TAKING A READING 2.1 BEFORE YOU START Select a cup which gives a flow time of between 30 seconds and 100 seconds. Ensure the cup and the orifice are clean and free of debris. The liquid being tested must be homogeneous and must not contain any bubbles. Use freshly strained samples only. The liquid being tested must be newtonian. To determine whether a liquid is newtonian, carry out the following measurements using the instructions given in Test procedure on page 5: Fill the cup and measure flow time immediately after filling. Fill the cup, wait one minute, then measure flow time. If the difference between the two flow times is greater than 10%, the liquid is considered to be nonnewtonian and cannot be tested using the Viscosity Cup. Measure and record the temperature of the liquid. 4

2.2 TEST PROCEDURE 1. Place the cup into the stand and level the cup using the glass plate and bubble level supplied with the stand. 2. Allow the temperature of the cup and the sample to stabilise at the agreed temperature. Check the temperature of the sample before filling a. 3. Place a finger over the cup orifice to close the orifice. 4. Pour the liquid gently into the cup, avoiding the formation of air bubbles. a. If the test environment is not temperature stabilised, use a double wall jacket - see Accessories on page 9. 5

5. Slide the glass plate over the rim of the cup to remove excess sample. Avoid the formation of air bubbles between the glass plate and the liquid. 6. Remove finger from cup orifice and wait for a few minutes to allow any air bubbles to rise to the top of the liquid. 7. Remove the glass plate and start the stopwatch. 8. Watch the flow of liquid from the orifice and stop the stopwatch the moment the flow breaks. 9. Repeat the test. 10. If the test results do not differ by more than 5%, calculate the average of the two test results and record the result. 6

The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cst). To convert, use the Elcometer 2400 Viscosity Disc - see Related equipment on page 10. 2.3 AFTER THE TEST Clean the gauge and all equipment. Do not use wire brushes, metal scrapers, metal files or other metallic tools for cleaning. Viscosity Disc Clean the gauge and all equipment using a suitable solvent. After cleaning, ensure that all materials are removed and that the instrument is dry. 3 STORAGE Always store the gauge in its case. 4 TECHNICAL SPECIFICATION Body: Orifice: Accuracy Anodised aluminium Stainless steel 2350 - DIN4 2351 - ASTM 2353 - ISO 2354 - BS 3% 10% 3% 2.5% 7

5 MAINTENANCE Elcometer Viscosity Cups are designed to give many years reliable service under normal operating and storage conditions. Regular calibration checks over the life of the gauge are a requirement of quality management procedures e.g. ISO 9000 and other standards. To check for wear, use Elcometer 2410 Viscosity Standard Oils b in place of your liquid and measure the flow time. If wear is detected, contact Elcometer or your local Elcometer supplier. Details of Elcometer offices around the world are given on the outside cover of these Operating Instructions. Alternatively visit the Elcometer website, www.elcometer.com b. See Viscosity standard oils on page 11 for ordering information. 8

6 ACCESSORIES Stand (with bubble level and glass): Stand, double wall jacket (with bubble level and glass): KT002400N001 KT002400N002 Double wall jacket Bubble level: Glass plate: KT002400P001 KT002400P999 7 CERTIFICATION Elcometer Viscosity Cups are supplied with a Batch Calibration Certificate as standard. Individual Calibration Certificates are available but must be requested at the time of order as they can not be issued retrospectively. 9

8 RELATED EQUIPMENT In addition to Viscosity Cups, Elcometer produces a wide range of other equipment for measuring the physical characteristics of surface coatings. Users of the Elcometer Viscosity Cups may also benefit from the following Elcometer products: Elcometer 2410 Viscosity Standard Oils for Calibration Elcometer 2400 Viscosity Disc Elcometer 7300 Digital Stopwatch Elcometer 212/213 Digital Thermometer For further information contact Elcometer, your local supplier, or visit our website at www.elcometer.com 10

9 VISCOSITY STANDARD OILS Part Number Range at 25 o C (77 o F) Cup Type Cup No. Model Orifice Diameter K0002410M022 60-120cSt DIN Flow Cup 4 Elcometer 2350/2 4mm K0002410M023 100-230cSt DIN Flow Cup 4 Elcometer 2350/2 4mm K0002410M024 200-460cSt DIN Flow Cup 4 Elcometer 2350/2 4mm K0002410M021 20-34cSt ASTM/Ford Flow Cup 2 Elcometer 2351/2 2.53mm K0002410M022 60-120cSt ASTM/Ford Flow Cup 3 Elcometer 2351/3 3.4mm K0002410M023 100-230cSt ASTM/Ford Flow Cup 4 Elcometer 2351/4 4.12mm K0002410M021 20-34cSt ISO Flow Cup 3 Elcometer 2353/1 3mm K0002410M022 60-120cSt ISO Flow Cup 4 Elcometer 2353/2 4mm K0002410M023 100-230cSt ISO Flow Cup 6 Elcometer 2353/4 6mm K0002410M024 200-460cSt ISO Flow Cup 6 Elcometer 2353/4 6mm 11

10 ELCOMETER VISCOSITY CUPS Elcometer model 12 Cup number Applicable standards Range (cst) Without Calibration Certificate Part Number With Calibration Certificate 2350/1 2 - - K0002350M001 K0002350M001C 2350/2 4 DIN 53211 96-683 K0002350M002 K0002350M002C 2350/3 6 - - K0002350M003 K0002350M003C 2350/4 8 - - K0002350M004 K0002350M004C 2351/1 1 ASTM D1200 10-35 K0002351M001 K0002351M001C 2351/2 2 25-120 K0002351M002 K0002351M002C 2351/3 3 49-220 K0002351M003 K0002351M003C 2351/4 4 70-370 K0002351M004 K0002351M004C 2351/5 5 200-1200 K0002351M005 K0002351M005C 2352/1 2.5 NF T30-014 5-140 K0002352M001 K0002352M001C 2352/2 4 50-1100 K0002352M002 K0002352M002C 2352/3 6 510-5100 K0002352M003 K0002352M003C 2353/1 2353/2 3 4 ISO 2431 a ASTM D 5125 7-42 34-135 K0002353M001 K0002353M002 K0002353M001C K0002353M002C 2353/3 5 91-326 K0002353M003 K0002353M003C 2353/4 6 188-684 K0002353M004 K0002353M004C 2353/5 8 - - K0002353M005 K0002353M005C 2354/1 2 BS 3900 A6:1971 - K0002354M001 K0002354M001C 2354/2 3 AS/NZS 1580.214.2 - K0002354M002 K0002354M002C 2354/3 4 (Cup 4 only) - K0002354M003 K0002354M003C 2354/4 5 - K0002354M004 K0002354M004C 2354/5 6 - K0002354M005 K0002354M005C a. ISO 2431 supersedes DIN 53224 NF T30-070, EN 535, NBN T22-108 Efflux Time Certificate Dimensional Certificate