RegO Adapters, Connector, & Fittings

Similar documents
ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

Excess Flow Valves. General Information. How They Work. An Explanation and Warning. Proper Installation

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957

User Information Sheet 013

1200B2 Series Service Regulators. Instruction Manual

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Section B Cylinder and Service Valves

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

1800C and 1800C-HC Series Service Regulators

Pressure Regulator B-95

Refrigerant Gases Valves

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

RG1200 Service and Repair Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual

Industrial Compression Style Fittings

2 in. 18 Gauge Brad Nailer. User manual

Regulator from 1800 B series

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements

3/8" Dr. Air Butterfly Impact Wrench

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

INSTRUCTION MANUAL & PARTS

KJ4000 Operating Instructions & Parts Manual NSN

TECHNICAL DATA. Page 1 of 12

INDUSTRIAL PRODUCTS. Industrial Products Catalog. Innovative Solutions for Gas Management Systems ENTERPRISES

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Choosing the right miniature instrument and control valve is a snap

NEW Edge Series Products: OUTFITS and REGULATORS

PRO-50 Instrument Supply Regulator

Portable Hydrostatic Pneumatic Test Pump. Procedure Manual

Pressure Dump Valve Service Kit for Series 2300 Units

Industrial Compression Style Fittings. Compression Fittings Compress-Align Fittings Brass Metric Compression Poly-Tite Fittings Hi-Duty Fittings

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

V-24 OXYGEN LANCE VALVE

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

1805 Series Relief Valves

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

High Pressure Cylinder Valves

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

2.0 INSTALLATION & SERVICE

4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY:

shutoff valves 900 Series psig Manual Shutoff Valves

TECHNICAL DATA CAUTION

BS Series Basket Strainer

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

Section 3- Repair and Calibration Procedures

APPS-160 Gen 2 User Manual

Industrial Products. Innovative Solutions for Gas Management Systems. Global Gas Management Technology. Enterprises Innovator Medica Westwinds

AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES

SIMPLAIR PIPING TOOL. JXT Company

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Instruction Manual Updated 7/26/2011 Ver. 2.2

PLUMBING WATER & GAS TRADE CATALOGUE

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Speed control assembly model A-1

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Model: AT-1000 L.P.G. FREEZE VALVE

G7S Hand Pump Owner s Manual

CASH VALVE CRYOGENIC CONTROLS

Operation Manual Piston Sensed Gas Pressure Regulators

Owner's Manual and Instructions

SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.

Types 749B and R130 Changeover Manifolds

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

B-Too Drilling and Tapping Machine

DBML-60/80 Squeeze Tool

Description Pressure range Connection thread Device Page

Pressure Regulators. Instructions for Use

CAPITAL CONTROLS SERIES NXT3000

Right-Angle Tube Roller Model

V43 Pressure Actuated Water Regulating Valve

Please Contact Do It American for Pricing

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Continental Industries STEEL SERVICE TEES or FAX Visit

Operating Instructions Models and Hydrostatic Test Pumps

7625 West New York Street Indianapolis IN Phone: Fax: Order Desk:

AIR/OVER HYDRAULIC JACK 20 TON

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Industrial Products Catalog Tank Valves

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Operating Instructions Model and Hydrostatic Test Pump

High Pressure Gas Master Valves

User Instruction Manual

INSTALLATION AND OPERATION INSTRUCTIONS

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Pressure Dump Valve Service Kit for Series 3000 Units

Transcription:

RegO dapters, onnector, & Fittings Extended Type ouplings for Vapor and Liquid Service esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging cautious removal to properly bleed off trapped product to assure closure of the filler valve and hose end valve. The ME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle, providing for durability under repeated use. Type of Service onnection (M. NPT) L2* L Liquid L4 " L** L Vapor L * Includes 99- adapter, shipped loose. ** Includes L- adapter, shipped loose. oupling onnection (F. ME) pprox. Length " Series Series Short Type ouplings for Vapor and Liquid Service Style For Liquid Filling Style For Liquid Filling Style For Vapor Equalizing Style For Vapor Equalizing Style rass onnection (M. NPT) oupling onnection (F. ME) Tailpiece ore 64" End To Nut Overall Length 2" 2 " 8 2 6" 2 6" 9 rass Nut & Steel Nipple 2" 6" 2 2" 2 " Steel 8 2 6" 2 9 2" 6" 2 6" 2 6" 8 rass 6" 2" 8 " 6" 9 2 6" 2 6" ME Wrench # escription J Wrench For ME Wrench I2 For ME Wrench I2 J Wrench 80

RegO dapters, onnector, & Fittings ME heck onnectors for Lift Trucks These brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. ack checks automatically close in each connector when disconnected. The 4M couples directly to the service valve. n integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. gasket at the ME thread is a secondary seal when the connectors are tightened together. The connector fits RegO lift truck cylinder filling adapters for fast, convenient filling. The 4F accepts fuel line adapter and couples directly to the 4M. The O-ring seal in the 4M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ME threads provide rapid effortless make-up, even against LP-Gas pressure. 4M 4F pplication Inlet Outlet 4M 4F Service Valve Fuel Line F. NPT F. ME M. ME F. NPT *Recommended to minimize foreign material entering valves which could result in leakage. ** See page 82 for size chart. Protective ap* Rubber rass 4M-40 4FP Repair s** Gasket 4M-R (2 Per Pkg) O-Ring -2 Unloading dapters for ontainer Evacuation esigned to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the ME male hose connection of RegO Filler Valves used on RegO ouble heck Filler Valves and Multivalves. The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container. 9 20 2 Style In-Line ngle Filler Valve onnection F. ME onnection M. ME F. NPT 9 20 2 Filler dapters These adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). n integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container. 9 uilt-in Vent Valve Filler Valve onnection onnection V V 9 Yes No F. ME M. ME 8

RegO dapters, onnector, & Fittings End dapters for OT ylinder Filling esigned to provide quick and easy filling of OT cylinders with POL or Type I connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO 90T Quick cting Shut-Off Valve. These filling connectors have an extended connection on the handwheel, which makes it possible to connect the loading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation. 9-0 pplication Inlet onnection Outlet onnection s 9-0 9U-0 Filling of OT ylinders with POL onnections Filling of OT ylinders with Type I onnections M. NPT M. POL (G 0) Type I onnection ( 6 M. ME) rass and Stainless Steel rass 9U-0 onnector for OT ylinder Filling dapter The 9T-0 is designed for use on the 9-0 Filling dapters. onnector allows adapter to be used on the 6 M. ME & F. POL connections of Type valves. pplication Inlet onnection Outlet onnection s 9T-0 onverts 9-0 dapter from POL to a Type onnection M. POL G 0 Type onnection ( 6" M. ME) rass 9T-0 End dapter for Lift Truck ylinder Filling The 9L-0 is designed to provide quick and easy attachment of the filling hose to OT cylinders equipped with RegO 4M check connectors. 9L-0 pplication Filling of Fork Lift ylinders* Inlet onnection Outlet onnection ody ccessories dapter M. NPT F. ME rass 60 * The 9L-0 is intended to be permanently attached to the filling hose. 60 adapter enables the 9L-0 to be attached to the POL connection on the 9-0 at regulator cylinder filling stations to allow for occasional filling of fork lift cylinders. Lever Operated End dapter for Fork Lift ylinder Filling esigned to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO 4M check connectors. pplication Inlet onnection Outlet onnection s 9K-0 Lever Operated for Quick Filling of Fork Lift ylinders F. NPT Quick isconnect Yoke* rass and Steel * For use with RegO 4M check connector. 82

RegO dapters, onnector, & Fittings ME Plugs Specifically designed to withstand the everyday abuse given hose end valves on delivery trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent possible gas contamination from these same sources. The heavily ribbed outer surface permits hand-tight make-up. (M. ME) 6N 6N 6PR Nylon rass hain & Ring Fits Pipe Size Up To: 6N 2 Nylon 69N 2" Not pplicable POL Plugs Highly recommended for installation in LP-Gas cylinder valve POL outlets whenever the service line is disconnected or when the cylinder is being transported. When properly installed, the POL plug is designed to prevent contamination of the valve outlet and guards against product leakage if the cylinder valve is accidentally opened. 90EZP 0R W/hain & Ring onnection 90EZP 08P 0R Plastic rass M. POL (G 0) aps and Reducers 08P (Has hole for attaching wire to prevent loss of plug) 44-9 Plastic ap 94-90 Metal ap 6 Reducer oupling ap With hain & Ring Ring Fits Pipe Size Up To: ap Only 44-9 44-9P 4-9 ycolac 4-9P 4-9 806-9 806-9P Nylon 08 Thread onnection F. ME F. ME F. POL (G 0) 4FP F. ME P F. ME rass 84-90 2" 2 F. ME 94-90 " 94-9 6* F. ME 84-90 2" 2 F. ME 94-90 " Steel F. ME 6* * Reduces to M. ME 4FP ap Plug 08 POL ap G 0 P ap Plug 8

RegO dapters, onnector, & Fittings Washers (ctual Size) # Use Size 4M-R Fork Lift onn. ME 269-20R ME 29-20R Filter, Vapor Valve & dapter ME 84-8R onnections 2 ME 94-8R ME 4M-R 29-20R 269-20R 84-8R 94-8R una-n O-Rings (ctual Size) # Use 9- POL Nipple Size POL -2 Internal Fork Lift ME 84-20R Filler, Vapor Valve 2 ME 94-20R & dapter onnections ME 9- -2 84-20R 94-20R 84

RegO dapters, onnector, & Fittings ME dapters 64 M. ME F. NPT 64 64 64 64E " rass 66E " 2 66F 68G 68H 2" 68J 2 64 64E Steel " E iameter For Spare Gasket Order No. 269-20R 2 2 6" 84-8R 2 94-8R 2 6" 269-20R 68H 2" 6" 94-8R Gasket (Furnished with adapter) E ME x Female NPT M. ME M. NPT E iameter For Spare Gasket Order No. 6 6" 29-20R 6 6" 6E " 269-20R 2 6F 6F rass 2 2 2 6" 6" 6G 84-8R 6H 2" 2 2 6" 2 64" 69H 2" 2 69J 2 94-8R 2 69K " 6 6 6" 2 6" 6E " 269-20R 6F Steel 6" 6F 2 2 2 6" 84-8R 69H 2" 2 69K " 6" 2 94-8R E Gasket (Furnished with adapter) ME x Male NPT 6M M. ME iameter For Spare Gasket Order No. 2 6" 269-20R 6M rass 2 2 2 6" 2 64" 84-8R 69M 2 2 94-8R Gasket (Furnished with adapter) ME x ME M. ME Thread For Spare Gasket Order No. 64W Steel * 6" 269-20 * -6 UN Thread. ME x Miscellaneous (Recommended for securing hose-end valve when not in use). 8

RegO dapters, onnector, & Fittings Male POL Swivel dapters 90U (G 0) POL Hard Nose POL 90S (G 0) POL Soft Nose POL w/60 MS Orifice 90XS (G 0) POL Soft Nose POL w/excess Flow 0-0 Micron Filter 99W (G 0) POL Heavy uty Hard Nose POL w/excess Flow 90X (G 0) POL Hard Nose POL w/excess Flow 90W (G 0) POL 90HT Soft Nose POL w/handwheel (G 0) POL 90JR Hard Nose POL w/ arb onnection losing Flow (Propane) rill Liquid (GPM) 90U 6" 2 90S 6" 2 90X 2 64" 404.0 90XS M. NPT 6" 99W rass 2 6" 40 0.9 90W 2 90HT 6" 90JR arb Note: ll nipples incorporate wrench hex section. 2 Vapor at 00 PSIG Inlet (SFH) G Swivel dapters 2982 2982G rass M. NPT 9 6"-8NF 6" 6" G 86

RegO dapters, onnector, & Fittings POL dapters (G 0) POL Male POL x Female NPT F. NPT 2906 6" rass 2906G 2" 2906 2906F 2906E rass (G 0) POL Male POL x Male NPT and SE Flare M. NPT SE Flare SE Flare 2 6" 2 6" iameter 9 G 0 (POL) G 0 (POL) Female POL x Male NPT Female POL x Female NPT and Female POL 60Z F. NPT iameter 6" 60 60 64" 60 rass 4 64" 60 60S dapter For use with fuel gases (LP-Gas, cetylene). POL (G 0) 2 00 rass 9 6"-8NF (L.H.) M. NPT 9 6". M. NPT 6 6 rass 6 6 4- rass M. NPT iameter 6" 6" Miscellaneous dapters Female Inverted Flare. Female Inverted Flare x Male NPT Pressure Gauge dapter 2 6". E 494- rass F. NPT F. NPT M. NPT Male Female E F 28-8 UNF -8 UNF 6" 2" rass -6 UNF -6 UNF 6" 2 arb 2-4 UNF -4 UNF 6" 2 F 8