INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Similar documents
Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format

Organisation Internationale de Métrologie Légale

pren CEN standard-draft pr EN 12261

OIML R 140 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Measuring systems for gaseous fuel

Ships tank - General requirements

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Metering Code Gas TSO, measurement by connected party Effective from to the present

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

WELMEC European Cooperation in Legal Metrology

OIML R 16-1 RECOMMENDATION. Edition 2002 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-invasive mechanical sphygmomanometers

RMG Meßtechnik GmbH. Publication No E

TITLE OF THE CD (English): Revision OIML R 71 Fixed Storage Tanks - General Requirements

OIML R 126 RECOMMENDATION. Edition 1998 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Evidential breath analyzers DE MÉTROLOGIE LÉGALE

INTERNATIONAL STANDARD

P U B L I C N O T I C E

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Fixed storage tanks - General requirements

OIML R 71 RECOMMENDATION. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Fixed storage tanks. General requirements

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

Electronic Turbine Meter TERZ 94

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Mechanical vibration Rotor balancing. Part 11: Procedures and tolerances for rotors with rigid behaviour

Part 6: Critical flow orifices

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

THE WAY THE VENTURI AND ORIFICES WORK

Smart Water Application Technologies (SWAT)

OIML R 143 RECOMMENDATION. Edition 2009 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Gas Pressure Regulator R 51

EC type-examination certificate UK/0126/0065 Revision 1

Certificate of Approval. No 5/6B/211

United Kingdom of Great Britain and Northern Ireland

Supplementary Certificate of Approval. No S433

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Rotor Gas Meter. Creators in flow

Manual HA/CPT E

White Paper August , Rev AA

Instruction and Maintenance Manual

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS

ISO 2503 INTERNATIONAL STANDARD

EUROPEAN pr I-ETS TELECOMMUNICATION September 1995 STANDARD

American National Standard

TECHNICAL SPECIFICATION

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

INTERNATIONAL STANDARD

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Part 1: General principles

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Vehicle-mounted meters, pump supplied

INTERNATIONAL STANDARD

Grafiska symboler för scheman Del 8: Ventiler och spjäll. Graphical symbols for diagrams Part 8: Valves and dampers

Old documentation - Only for your information! Product is not available anymore!

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

INTERNATIONAL STANDARD. Cranes - Safety signs and hazard pictorials - General principles

United Kingdom of Great Britain and Northern Ireland

This document is a preview generated by EVS

Ultrasonic Flowmeter USZ 08

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

ISO INTERNATIONAL STANDARD

Performance tests of two insertion type thermal mass flow meters

ISO 407 INTERNATIONAL STANDARD. Small medical gas cylinders Pin-index yoke-type valve connections

CORESTA RECOMMENDED METHOD N 6

Cover Page for Lab Report Group Portion. Pump Performance

ISO 1977 INTERNATIONAL STANDARD. Conveyor chains, attachments and sprockets. Chaînes de manutention, plaques-attaches et roues dentées

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

KENYA ACCREDITATION SERVICE

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Instruction and Maintenance Manual

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Gas cylinders Cylinder valves with integrated pressure regulators Specification and type testing

IGTM Gas Turbine Meter. with electronic outputs and mechanical counter. Documentation and Technical Specifications

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

IGTM Gas Turbine Meter. Documentation and Technical Specifications. Gas - Measurement. with electronic outputs and mechanical counter

ISO INTERNATIONAL STANDARD

DNVGL-CP-0187 Edition March 2016

This document is a preview generated by EVS

Gas Pressure Regulator HON 200

Product information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution

Part 2: Fluid power systems O-rings. Housing dimensions for general applications

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

Vehicle- or rack-mounted liquefied gas meters, pump supplied

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

Double gas valves for biogases and recycling gases

Determination of density by volumetric displacement Skeleton density by gas pycnometry

GCC STANDARDIZATION ORGANIZATION (GSO)

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

Transcription:

INTERNATIONAL OIML R 32 RECOMMENDATION Edition 1989 (E) Rotary piston gas meters and turbine gas meters Compteurs de volume de gaz à pistons rotatifs et compteurs de volume de gaz à turbine OIML R 32 Edition 1989 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL ORGANIZATION OF LEGAL METROLOGY

Foreword The International Organization of Legal Metrology (OIML) is a worldwide, intergovernmental organization whose primary aim is to harmonize the regulations and metrological controls applied by the national metrological services, or related organizations, of its Member States. The two main categories of OIML publications are: International Recommendations (OIML R), which are model regulations that establish the metrological characteristics required of certain measuring instruments and which specify methods and equipment for checking their conformity; the OIML Member States shall implement these Recommendations to the greatest possible extent; International Documents (OIML D), which are informative in nature and intended to improve the work of the metrological services. OIML Draft Recommendations and Documents are developed by technical committees or subcommittees which are formed by the Member States. Certain international and regional institutions also participate on a consultation basis. Cooperative agreements are established between OIML and certain institutions, such as ISO and IEC, with the objective of avoiding contradictory requirements; consequently, manufacturers and users of measuring instruments, test laboratories, etc. may apply simultaneously OIML publications and those of other institutions. International Recommendations and International Documents are published in French (F) and English (E) and are subject to periodic revision. This publication reference OIML R 32 (E), edition 1989 which is under the responsibility of OIML TC 8/SC 8 Gas meters, was sanctionned by the International Conference of Legal Metrology in 1988 and suspersedes the previous edition dated 1979 OIML publications may be obtained from the Organization s headquarters: Bureau International de Métrologie Légale 11, rue Turgot - 75009 Paris - France Telephone: 3 (0)1 48 78 12 82 and 42 85 27 11 Fax: 3 (0)1 42 82 17 27 E-mail: iml@oiml.org Internet: ww.oiml.org 2

ROTARY PISTON GAS METERS and TURBINE GAS METERS 1 Scope This Recommendation applies to : 1.1. rotary piston gas meters in which internal walls defining the measuring chambers are set in rotation and the number of revolutions of these walls represents a measurement of the volume of the gas passed. 1.2. turbine gas meters where the gas flow rotates a turbine wheel and the number of revolutions of this wheel represents the volume of the gas passed. With regard to the gas meters defined above, this Recommendation complements the International Recommendation R 6 General provisions for gas volume meters, the provisions of which apply jointly with the requirements of this Recommendation. 2 Working range 2.1. The authorized values of the maximum flowrates and the corresponding minimum flowrates of rotary piston gas meters and turbine gas meters are given in the following Table. Gas meter designation G Q max m 3 /h Working range 1:10 1:20 1:30 1:50 Q min m 3 /h 16 25 2.5 1.3 0.8 0.5 25 40 4 2 1.3 1.8 40 65 6 3 2 1.3 65 100 10 5 3 2 100 160 16 8 5 3 160 250 25 13 8 5 250 400 40 20 13 8 400 650 65 32 20 13 650 1 000 100 50 32 20 1 000 1 600 160 80 50 32 and decimal multiples of the values of the last 5 lines of the above Table. 3

3 Details of construction 3.1. Rotary piston gas meters 3.1.1. Rotary piston gas meters shall have a static pressure tapping at the inlet and at the outlet close to the connection (flange) for measuring the pressure absorption ; the pressure measured upstream shall constitute the metering pressure. 3.1.2. Rotary piston gas meters may include a manual device for allowing the pistons to be turned, provided that it cannot be improperly used in such a way as to interfere with the correct functioning of the gas meter. 3.1.3. Notwithstanding the requirements of point 8 of R 6, the bearings of the shafts of the rotating pistons of gas meters (Roots type) of a size greater than G 160 may be constructed in such a way as to allow them to be replaced without damaging the protective seals. 3.2. Turbine gas meters 3.2.1. Turbine gas meters shall have a pressure tapping permitting the determination (indirectly if necessary) of the pressure immediately upstream of the turbine wheel as the metering pressure. 3.2.2. If there is a nozzle upstream of the turbine wheel, the turbine gas meter may have, in addition to the pressure tapping required in point 3.2.1, a second pressure tapping immediately before this nozzle, so that the pressure drop due to the nozzle can be measured. 3.3. Pressure tappings 3.3.1. The bores for pressure tappings shall have a diameter of at least 3 mm. In the case of slit-shaped pressure tappings, slits shall have a width of at least 2 mm in the direction of the flow and a crosssection of atleast 10 mm 2. 3.3.2. Pressure tappings shall be provided with a means of closure so as to make them gas-tight. 3.3.3. The pressure tapping for the metering pressure shall be clearly and indelibly marked р m and other pressure tappings р. 3.4. Built in conversion device 3.4.1. Rotary piston gas meters and turbine gas meters may have a built-in conversion device which converts the volume at metering temperature to that at base temperature or which converts the volume at metering conditions to that at base conditions. 3.4.2. The indicating device for the volume at base conditions shall have a sufficient number of digits to ensure that the volume passed during 2000 hours at maximum flowrate, minimum temperature and, if applicable, maximum pressure does not move or switch all the digits to their initial positions. 4

4 Test element 4.1. When the gas meter has a mechanical test element according to point 5.2.2 of R6, the scale interval and the scale numbering shall comply with the following Table. 1:10 1:20 Designation G for working range 1:30 1:50 maximum scale interval m 3 numbering every m 3 16 0.000 2 0.001 16-65 16-100 25-160 0.002 0.01 100-650 160-1000 250-1600 0.02 0.1 1000-10000 1600-10000 2500-16000 0.2 1 16000 16000 25000 2 10 4.2. The scale interval of the test element of the indicating device for base conditions shall be less than 0.1 % of the converted volume counted in three minutes with maximum flowrate at maximum temperature and, if applicable, minimum pressure. 5 Maximum permissible errors 5.1. Under the conditions laid down in point 6 of R 6, the maximum permissible errors are as follows : Flowrate Q m 3 /h on intial verification Maximum permissible errors in service Q min Q Q t Q t Q Q max ± 2 % ± 1 % ± 3 % ± 1.5 % Note : In service values are recommended values. The values for the transitional flowrate Q t are as follows : Working range 1 : 10 1 : 20 1 : 30 1 : 50 Q t 0.20 Q max 0.20 Q max 0.15 Q max 0.10 Q max 5.2. On initial verification at one set of metering conditions the gas meter shall be adjusted so that the weighted mean error (WME) is as close to zero as the adjustment and the maximum permissible errors allow. 5

The WME is calculated as follows : n (Q i / Q max ) E i i = 1 WME = n (Q / Q ) i = 1 where : Q i /Q max is a weighting factor. E i is the error at the flowrate Q i as specified in point 7.2.1. (where Q i = Q max a weighting factor of 0.4 instead of 1 shall be used). The WME shall have a value between 0.4 % and + 0.4 %. Note : After changing the adjustment it is not necessary to repeat all tests. It is sufficient to repeat a test at one flowrate and calculate the other new E i values from the previous ones. 5.3. The maximum permissible errors on initial verification apply to new meters and to meters submitted for verification after the protective seals have been damaged. 5.4. When the maximum torques indicated on the gas volume meter according to points 3.2.1 and 3.2.2 of R 6 are applied to the drive shafts, the indication of the gas volume meter at Q min when tested with atmospheric air (of density 1.2 kg/m 3 ) shall not shift more than the values given in the following Table. i max Value of Q min 0.02 Q max 0.03 Q max 0.05 Q max 0.1 Q max Permissible shift of the indication at Q min 1 % 1 % 1 % 0.5 % 6 Pattern approval 6.1. Request for pattern approval At the same time as the pattern sample is submitted, the applicant shall place at the disposal of the Authority responsible for the examination from two to six sample meters manufactured in conformity with the pattern. If so requested by the Authority responsible for the examination, these meters should include more than one size if simultaneous approval of those sizes is requested. Depending on the results of the tests, additional sample meters may be requested. Notwithstanding the above provisions, the sample meters may be submitted at different times, but the decision regarding pattern approval will be given only when all these sample meters have been received and examined. 6.2. Examination 6.2.1. General 6.2.1.1. The pattern and its sample meters shall comply with the requirements of R 6 and of points 2, 3, 4 and 5 of this Recommendation. 6

6.2.1.2. In addition, for flowrates between 0.4 Q max and Q max the difference between the maximum and minimum of the error curve as a function of the flowrate Q shall not exceed 1% for each meter. 6.2.2. Disturbance test for turbine gas meters 6.2.2.1. Turbine gas meters are submitted to a test for the influence of flow disturbances as specified in Annex A. 6.2.2.2. During the test the shift of the error curve shall not exceed 0.33 %. 6.2.2.3. If the design of a turbine gas meter pattern is similar for all the pipe sizes, disturbance tests with gas meters of two sites shall suffice. 6.2.3. Durability test 6.2.3.1. The pattern and samples of rotary piston gas meters and turbine gas meters shall be submitted to a durability test. This test shall be carried out as far as possible at the maximum flowrate and with air or gas. 6.2.3.2. The duration of the durability test shall be such that each gas meter measures a volume of air or gas corresponding to 1000 hours of operation of the gas meter at the maximum flowrate ; the test shall be completed within 2 months. 6.2.3.3. After the durability test, the gas meters, when tested with air of density 1.2 kg/m 3, using the same standard instruments as those used in the test resulting from point 6.2.1.1 shall comply with the following requirements : a) the values of the errors determined at the flowrates specified in point 7.2.1 shall not differ by more than 0.5 % from the errors noted during the test resulting from point 6.2.1.1, b) for flowrates between 0.4 Q max and Q max, the difference between the maximum and minimum of the error curve as a function of the flowrate Q shall not exceed 1.5 %. 6.2.4. Gas meters with drive shafts 6.2.4.1. In the case of rotary piston gas meters and turbine gas meters having one or more drive shafts, at least three meters of each size shall be tested with air at a density of 1.2 kg/m 3 for compliance with the requirements of R 6, point 3.2.4 and of point 5.4 of this Recommendation. In the case of rotary piston gas meters and turbine gas meters having several drive shafts, the test shall be carried out on the drive shaft which gives the least favourable result. For gas meters of the same site, the lowest torque value obtained in the tests shall be used as the maximum permissible torque value. Where a pattern embraces gas meters of various sizes, the torque test need be carried out only on the meters of the smallest size, provided that the same torque is specified for the larger gas meters and that the output shafts of the latter have the same or greater output constants. 6.2.4.2. In the case of gas meters with several values for Q min only the test described in point 6.2.1 for the least value of Q min need be carried out. The permissible torques for the other working ranges may be calculated from that test result. Conversion to other Q min values is governed by the following rules : a) where the flow is constant, the variation in the error is proportional to the torque ; 7

b) where the torque is constant, the variation in the error for rotary piston gas meters is inversely proportional to the flowrate, and for turbine gas meters it is inversely proportional to the square of the flowrate. 7 Initial verification and subsequent verifications 7.1. Examination 7.1.1. Gas meters are examined and tested to ascertain whether they conform in general to their approved patterns, and comply with the requirements of R 6, as well as the requirements of this Recommendation. 7.1.2. Gas meters shall be submitted in working order and shall be provided with the required sites for the application of the verification and protective marks. 7.1.3. If gas meters are intended to incorporate ancillary devices operated by the output shafts, these devices shall be attached, unless attachment after verification is expressey authorized. 7.2. Accuracy tests 7.2.1. A gas meter shall be considered to comply with the requirements concerning the maximum permissible errors if these are met at the following flowrates : a) for gas meters with a working range of 1:10 to 1:30 : Q min, 0.05 Q max and 0.1 Qmax when these values are larger than Q min, 0.25 Q max, 0.40 Q max, 0.70 Q max and Q max, b) for gas meters with a working range of 1:50 : Q min, 0.05 Q max, 0.15 Q max, 0.25 Q max, 0.40 Q max, 0.70 Q max and Q max. If the tests are done at other flowrates, they shall be at least as effective as those mentioned above. 7.2.2. A gas meter may be verified using a gas other than air, and/or at other than near-ambient conditions. 7.3. Additional markings The density range in which the errors are required to comply with the maximum permissible errors may be indicated on the data plate, expressed as : ρ =... kg/m 3 This marking may replace the range of metering pressures (point 4.1.(i) of R 6), unless the pressure marking refers to a built-in conversion device. 8

ANNEX A DISTURBANCE TEST FOR TURBINE GAS METERS A.1. General A.1.1. The test specified in this Annex should be carried out with air at close to ambient conditions at flowrates of 0.25 Q max, 0.4 Q max and Q max. A.1.2. If the design of the pattern of the gas meter is similar for all pipe sizes, it is sufficient to perform the test on two sizes. Similarity of sizes is assumed if the values of H/D and S/L (see figure 1) for any size of meter are equal to or less than those for the tested meters. A.2. Mild disturbances A.2.1. The piping configurations (see figure 2a and 2b) consist of a pipe with a nominal diameter DN, and with a length of 5 DN 1, two elbows with radius DN 1, not in the came plane, and a concentric expander with diameter DN 1 and DN and a length between DN and 1.5 DN. 9

The values of DN 1, in relation, to the values of DN are listed in the following Table : DN (meter) (mm) 50 80 100 150 200 250 300 400 500 600 750 1000 DN 1 (pipe) (mm) 40 50 80 100 150 200 250 300 400 500 600 750 A.2.2. The test shall be carried out with the piping configurations as described in point A.2.1 installed 2 DN upstream of the meter inlet (see figure 2c), or with a longer upstream straight pipe and/or flow conditioner if so specified by the manufacturer. In the latter case the necessary upstream straight pipe and/or flow conditioner shall be considered part of the approved pattern and specified in the approval certificate. A.2.3. During the test the shift of the error curve of the meter shall not exceed 0.33 %. A.3. Severe disturbances A.3.1. The same piping configuration as specified in A.2.1 is used with the addition of a half pipe area plate as shown in figure 3 installed between the two elbows with the opening toward the outside radius of the first bend. A.3.2. The provisions of points A.2.2 and A.2.3 apply accordingly. 10

ANNEX B TEST PROCEDURES FOR ROTARY PISTON GAS METERS AND TURBINE GAS METERS (Under consideration) 11

Contents Foreword.2 1 Scope...3 2 Working range.3 3 Details of construction 4 4 Test element 5 5 Maximum permissible errors..5 6 Pattern approval..6 7 Initial verification and subsequent verifications.8 Annex A. 9 Annex B 11 12