OPERATION AND MAINTENANCE

Similar documents
THE DELIVERY OF GAS SUPPLY

multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

INTENDED USE TECHNICAL SPECIFICATIONS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Public. Water Supply Emergency Response Plan For The. Village of Clayton Water Treatment Facility. Public Water System I.D. No.

PHYSICAL FACILITIES Consultant s Handbook Division 33 Utilities 1300 Disinfecting Underground Potable Water Piping.

22. Specialty Valves.

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

Backflow What is it? City Water. Boiler. Make-Up Water Line

Associated Hazard (outcome) Control Measures. Reduction of water supply

DW Module 8: Distribution Answer Key

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

RISK ASSESSMENT & DISASTER MANAGEMENT PLAN

SECTION DOMESTIC WATER PIPING

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Siphon vessel / Priming aid

SECTION PRESSURE TESTING OF PIPING

Water Distribution Study Guide Class II (Made available by: Kansas Rural Water Association)

Introduction to Emergency Response & Contingency Planning

Well Disinfection NONCOMMUNITY PUBLIC WATER SUPPLY PROGRAM

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Rubber Dock Hose care, Use & Maintenance

SECTION 25 TESTING AND DISINFECTING WATER MAINS General

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL

TECHNICAL DATA. Q = C v P S

30T A/Manual Hydraulic Shop Press

Right-Angle Tube Roller Model

Vacufill MACHINE FOR FAST, ECONOMICAL AND EFFECTIVE COOLANT EXCHANGE, THE VACUFILL, WHILST UNDER VACUUM REFILLS THE COOLING SYSTEM IN SECONDS

9.0 Equipment Cleaning and Repair

Essentials of Fire Fighting 6 th Edition Firefighter I

Technical Service Bulletin March 2015 TSB142.01

Emergency Situation Assessment

STORM WATER RETENTION TANKS MAINTENANCE INFORMATION FOR HEALTH AND SAFETY FILE

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Series IRV1000/2000/3000

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

Flammability Chart. Gas Formula Ignition

TECHNICAL DATA. Q = C v P S

Pilot Check Valve: Metal Body Type

In this presentation we will talk about Florida Administrative Code, 64E-9 and how it regulates swimming pools and pool operator s responsibilities.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

TECHNICAL DATA OBSOLETE

. Cross Connections 1

G10K - 1/2" Heavy-Duty Air Impact Wrench


CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Village Of Cache Creek Policy No. H-2 Confined Space Entry

COMPRESSED AIR DISTRIBUTION SYSTEMS

Effective protection thanks to the latest technology

POWER LIFT LOW PRESSURE LIFTING BAGS. Instructions for use

Marschalk Model # 94000

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

ADVERSE WEATHER AT PUBLIC SWIMMING POOLS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

NORMAL OPERATING PROCEDURES Operating Parameter Information

Air Operated Hydraulic Pumping Systems to 50,000 psi

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03

Hydrolastic Fluid - where do you get it?

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Organization for Traffic Control on County Highways

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

POOL CARE GUIDE. The E-Z Clor System To Perfect Pool Water.

20 Ton SD Shop Press Operating Instructions

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Float Valve Function and Design Considerations

Essentials of Fire Fighting

Section 38 Brieser Construction SH&E Manual

Requests for Proposal (RFP) Swimming Pool Management Services

Village of Lombard. Building Division/Community Development Department 255 E. Wilson Avenue Lombard, IL Tel: Fax:

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

TEM# Air Hammer Combo USER'S MANUAL

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

Unit 24: Applications of Pneumatics and Hydraulics

Emergency Response Plan Supervisor Version

Drum / cylinder handling

Cylinder Tilt Saddle Instruction Manual

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

MoveRoll Conveyor Operating and Maintenance Manual

KJ1000 Operating Instructions & Parts Manual NSN

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

Chapter 10 SWIMMING POOLS

TECHNICAL DATA. Dry 132a. October 1, 2008

Airfix D-E-B Installation and operating instructions

75 Ton SD Shop Press Operating Instructions

Piped Air SCBA Refilling System Standard

Transcription:

Chapter 11 OPERATION AND MAINTENANCE General Considerations The nature and scope of the operation and maintenance required will vary with the design and elements of water-supply systems. Depending upon the particular situation, the field work may include : (1) well, spring, or drainage basin inspection and maintenance; (2) dam and reservoir maintenance; (3) pump and engine operation and maintenance; (4) treatment operation; (5) distribution system maintenance; (6) service connexions to system; (7) meter repairs and maintenance; (8) operation in emergencies; (9) detection and elimination of cross-connexions. Some information has already been given under the relevant sections regarding the principal features of operation and maintenance of various elements of water systems. This will not be repeated here; but some additional points of interest to waterworks field personnel are described in Annex 9 (see page 313). There are two principal factors which contribute to most failures in water systems : (a) equipment and materials used under conditions for which they were not designed; and (b) operators who, because of either ignorance or disinterest, do not recognize the signs which precede or portend breakdowns and failures. By careful review of plans, design, and specifications, the water-supply-control administration can succeed in preventing or eliminating most difficulties of a mechanical character. The reduction of troubles caused by the human element is perhaps harder to achieve; but much can be done, as previously indicated, through training of field personnel, assistance from outside qualified staff (a form of in-service training) and close supervision. Equipment For small water systems, the following suggestions may be made : (I) Manufacturers' recommendations as to operation and maintenance procedures should be scrupulously observed. They should be drafted into

244 WATER SUPPLY FOR RURAL AREAS a form which can be easily understood by the operators. This is especially important with regard to pumping machinery. (2) Maintenance should be organized according to rigid schedules. This applies to operations such as greasing, oiling, inspections, adjustments, and minor repairs. (3) A system of supervision should be established to ensure that procedures and schedules are followed. (4) Lubrication recommendations by the manufacturer of a particular piece of equipment must be followed. (5) Ample space must be provided for equipment operators or maintenance men to work and to keep tools, spare parts, oil, grease and other supplies. (6) Provision must be made for the establishment of suitably equipped workshops. The following major field equipment will be found useful in most instances (depending upon the scope of the water system) : (1) dump truck(s), for the transportation of pipes smaller than 25 cm (10 in.) in size; (2) an air compressor, pavement breakers. and air hammers; (3) ditch pumps (at least two of them) equipped with 3.6-m (12-ft) hoses, for keeping trenches dry during work; (4) electric generators, with two floodlights and extension cords, for emergency work at night; (5) a small crane, handling up to about 2.5 metric tons (3 tons), equipped with pneumatic tires and a ball-bearing swivel safety hook and capable of 180" turning capacity. A crane is not needed for handling pipes of less than 15 cm (6 in.) in diameter, but is useful for handling, turning, and lowering pipes of larger diameter. Handling large pipes with hand labour and ropes usually results in an undue amount of breakage of pipe joints. Distribution System First and foremost, the operation and maintenance of a distribution system require the establishment of system maps and records. The system map should be drawn on large scale, preferably not less than 1 : 10 000, and should show all streets and their names, mains and their sizes and locations, valves and hydrants, reservoirs and elevated tanks, supply sources, and any other useful information. Besides the making of at least one full map, the same map may be divided into sections and bound for easy handling in the field. In addition to the system map, valve records are necessary (except in very small water-supplies) to show their exact location, their numbering, and any particular reference regarding their operation. These records

MANAGEMENT OF WATER-SUPPLY SYSTEMS 245 can take the form of separate large-scale drawings, each for one valve, entered in a loose-leaf binder for handy reference. A system should be devised to ensure that these records and the maps are kept up to date. This is facilitated if pertinent information is reported and recorded after each rep@ or maintenance job is performed. These records are especially useful when valve boxes and cones are hidden or " lost ", having been covered in the course of street repairs or construction. The following specific suggestions may apply : (1) Valves: Their function and installation are described in a previous section (see page 205). Valves and hydrants (if any) should be inspected every two months. This should be a primary duty of field operators and should be carried out on a regular inspection schedule using a simple check list to ensure that no valve is missed. The effort spent will repay itself many times in cases of emergency and fire when valves must be located and operated quickly. Packing and leakage can also be checked at inspection time. (2) Piping : The maintenance of distribution pipes consists in checking for leaks, corrosion, and scale. Each time a line is opened, the interior of the piping can be observed. The life of more than one system has been greatly extended by workmen who have reported pipe damage when making a house connexion. (3) Tanks : Concrete tanks require very little attention, while steel tanks must be painted often to prevent damage from corrosion. Instructions of manufacturers regarding type of paints and methods for painting must be closely followed. (4) Meters : Meters usually require much attention. An organized maintenance system must be set up, or else the whole metering process will soon fail. A small repair shop is required for the cleaning and testing of meters and for the replacement of worn-out parts. It can be a room about 4 x 5 m (13 x 17 ft), equipped with benches, small tools, water connexions, gauges, etc. It need not be complex and may be run by from one to four trained persons. A well-equipped repair shop manned by four experienced workmen can handle up to 5000 ordinary service meters a year. Cross-Cornexions In small community water-systems, many opportunities exist for direct cross-connexions between public water-supplies and private cisterns and wells. Also, there is the always-present danger of back-siphonage of contaminated water from lavatory washbasins, water-closets, etc., into public distribution pipes when the domestic plumbing systems are not properly built. Furthermore, it does happen sometimes that the positive pressure existing in a main pipe drops suddenly to nil, or even becomes negative,

246 WATER SUPPLY FOR RURAL AREAS because of an accident, fire demand, leaking valves, or some human error of operation. Sanitary engineers are very familiar with the different types of cross-connexion and with the public health hazards associated with them. Many water-borne epidemics caused by accidental cross-connexions are reported in the literature. The field personnel of small water-systems should be alert to the danger and, although they are usually not respohsible for inspection of house plumbing, the field service should be prepared to advise and assist customers in eliminating such plumbing defects. Cross-connexions should be expressly forbidden. However, special requests from industries or neighbouring public water systems, for example, for connexions of their water pipes with the town's distribution system should be closely examined by competent public health or water engineers on behalf of, or attached to, the controlling health administration. Wherever possibilities exist for back-siphonage, a free-fall discharge of the town's water should be observed. It is generally agreed that a free fall equal to at least two pipe diameters above the highest flood level of the receiving unit is safe. In the case of lavatory washbasins, the maximum flood level would be the top of the basin, even though an overflow pipe is provided. Vacuum breakers are also used to prevent back-siphonage. They are usually installed at least 10-15 cm (4-6 in.) above the maximum flood level of the receiving unit, according to manufacturers' instructions. Special devices, such as the back-flow preventer, must be approved by the public health administration before they can be installed in a system linking private and public water-supplies. Operation in Emergencies Every public water-system, whether large or small, should be as prepared as possible for emergency operating procedures which may be necessitated by such catastrophes as earthquake, flood, war damage, or evacuation of populations due te war or sudden cataclysms. It must be remembered that, in such circumstances, water is probably the most urgent need of individuals, who will use any available source, polluted or not, with the consequent hazards of epidemics, if provision is not made quickly for a supply of safe water. In fact, the amount of water available may govern the number of evacuees who may be received and handled in a particular village or town. For this reason, it is recommended that, soon after the start of operation of a new water-system, or even before, a realisticinventory be made covering all available sources of water supplies, public or private, together with their capacities, location, accessibility and potability. This inventory should also include personnel resources and available, emergencytype, water-supply equipment, hand and motor pumps, water-tank trucks, pipe accessories (especially coupling ar,d jointing materials), mobile or

MANAGEMENT OF WATER-SUPPLY SYSTEMS 247 portable filter units, tools, spare parts, and chemicals (especially those for water disinfection purposes). At times of emergencies, a minimum of 1 litre (1 qt) of water should be provided daily for drinking only and another 3 litres (3 qt) for other purposes, in such places as temporary shelters. In camps with tents, a rninimum of 20 litres (5 US gal.) should be provided, and this amount should be doubled for the supply of temporary hospitals and first-aid stations. It goes without saying that every step should be taken to conserve water, and that every possible sanitary safeguard should be employed to protect existing supplies-especially surface supplies such as lakes, ponds, open reservoirs, and springs-from contamination. While ground-water supplies from properly constructed wells, infiltration galleries, and spring structures may sometimes be considered safe, all surface water should be considered of doubtful quality and should be disinfected by boiling, chlorination, or disinfection by iodine compounds. The notes previously given under " Household purification of water" (see page 185) also apply here, except that heavier chlorination is recommended. The free chlorine residual in reasonably clear water at times of emergencies should be not less than 5 p.p.m. after 30 minutes of contact 38 when the water has not had the benefit of prior filtration. The raw water should be taken from an approved source; and, if it has strong taste, odour, or colour, it should be avoided as far as possible.