NON RETURN / UNIDIRECTIONAL VALVE

Similar documents
To use the Atex valve model is obligatory to consult the appropriate manual.

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

FLANGED MULTI-PORT BALL VALVES

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

OPERATION MANUAL PNEUMATIC VALVES

Operating instructions - Translation of the original -

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

AIR INLINE METAL SHEAR

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

Installation & Operation Manual Proven Quality since 1892

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Pressure Relief Valve Instruction Manual

Flowmeter. Original operating manual DFM

ROPV R40 E Series User Manual

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Instruction manual. HLSD-2 Circular Access Tank Cover IM-TE91K041-EN1 ESE Date of issue: August 29, 2012

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type BBS-03, BBS-05, BBS-06, BBS-25

TactAir PCP Fill Kit/Adapter. Operation Manual

G&H SPC-1 SANITARY PROPORTIONAL-CONTROLLED VALVE WITH POSITIONER INSTRUCTION MANUAL IM US1 S 0812

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Operating instructions - Translation of the original -

Operating Instructions in accordance with the Machines Directive 2006/42/EC

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Sterile Visual Flow Indicator

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Operating and maintenance manual Filter and reducing station Series / 1.0

Installation and Operating Instructions Bypass Flow Meter DST

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Vessel Installation and Operating Manual

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Siphon vessel / Priming aid

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Model No Product Name Handpiece Only Complete System

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Cylinder Tilt Saddle Instruction Manual

Pressure Reducing Valve DMV 750

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Operating instructions - Translation of the original -

Model ASSEMBLY and OPERATING INSTRUCTIONS

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Pressure relief valve

Operating instructions - Translation of the original -

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Declaration of Conformity as per Directive 97/23/EC

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

453 Series Steam Heated Vaporizing Regulator

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Installation and Operating Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

MANUALLY OPERATED VALVE VLM SYNCROFLUX TECHNICAL MANUAL MT042/E

Non-Return Valve SRK 22A

Instructions for use Compressed air injector with water trap

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Pressure Reducing Valve

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pressure relief valve

Pressure Relief Valve DHV 718

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

TITAN FLOW CONTROL, INC.

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

VERTICAL AIR COMPRESSORS

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Atmospheric relief valve type 1100 Installation and maintenance instructions

Materials : Dichromate zinc plated steel flanges or AISI 316

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

MANUAL. Sesame. Thermoplastic Tank Technologies

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

User Instruction Manual

Transcription:

User and maintenance manual EDF valves M 7.5.7B pag. 1 di 21 USER AND MAINTENANCE GUIDE NON RETURN / UNIDIRECTIONAL VALVE EDF VALVE DN10-DN100 Carollo srl Unipersonale Via Pettinà, 24 36010 Zanè Italy M 7.5.7B User and manteinance manual_en_06 Rev.0 24/11/2015

CONTENTS 0. Introduction... 3 1. Valve Description... 3 2. Working Principle... 4 3. Declaration of Conformity CE... 5 4. Safety Symbols... 6 5. Safety Instructions... 6 6. Technical Data... 7 7. Unpacking / Storage... 9 8. Installation Instructions... 10 9. Start-up... 11 10. Troubleshooting... 11 11. Cleanliness... 12 12. Maintenance... 13 13. Planned Maintenance... 14 14. Disassembly / Assembly... 14 15. Warranty... 20 16. Recommendations... 21 - Valvola EDF-2

0. Introduction This instruction manual is an integral part of the delivery of the valve. You must: ALWAYS read carefully before using the valve; ALWAYS store it for future reference. All rights reserved. You may not reproduce or transfer any portion of this instruction manual by any means, electronic and mechanical - including photocopying, recording, or any other storage system or re-use for other purposes than exclusively personal use - without the prior written accord to the manufacturer. This manual's handbook is specifically intended for use by technical staff. For this reason some information easily deduced from the examination of the text and illustrations and drawings have not been specified. The publisher is not responsible for any consequences resulting from incorrect operations by the user. The data and information contained in this manual are subject to change or updates without further notice or obligation by the manufacturer. 1. Valve Description YGROS valve is a non return/unidirectional valve with magnetic technology. Inside Ygros valve there is not a spring, but the functioning takes place through the presence of a magnetic field. Ygros non return valve consists of: Valve body Shutter Front Flange Rear Flange Magnet (usually in 2 part) Gasket. Flanges can be chosen among: Welding ends, Tri-clamp ASME BPE Female DIN. - Valvola EDF-3

2. Working Principle Ygros non-return valve can stop the return flow of gasses and liquids. The Ygros non return valve opens the inflow pressure exceeds that of the out flow and magnetic field pressure combined. The valve closes when the difference in pressure ceases. A higher back pressure pushes the valve shutter against the seal. The gas / liquid flows inside the valve body by opening the shutter, once the flow is over the shutter returns to the closed position interrupting the flow of return. - Valvola EDF-4

3. Declaration of Conformity CE - Valvola EDF-5

4. Safety Symbols WARNING signal indicating that the general special instructions SHOULD BE followed to avoid serious injury. CAUTION generic signal indicating that you MUST follow special instructions to avoid damage to equipment and environment. NOTE! Identify IMPORTANT information to improve the understanding of the instructions. 5. Safety Instructions ALWAYS read the technical data before the installation, operation and maintenance. ALWAYS use authorized personnel for the installation, operation and maintenance of the valve. The staff must know perfectly the valve and the manual. Use the valve ONLY for the purpose intended. ALWAYS operate the valve carefully. ALWAYS make sure any split of the valve when removed from its packaging. NEVER touch a hot valve. The valve should be installed at a safe distance from components that can lead to turbulent motions fluid through the valve. Turbulent flows can cause noise, vibration and cavitations with consequent wear of valve components. In this case, the installation position of the valve to be modified. Always check before mounting, fluid chemical compatibility with the materials from which the valve (par. technical data) and seals. In conditions of difficult jobs and aggressive, periodically check of possible wear of the components that make up the valve (see par. Planned Maintenance). Install the valve due to distance from the external heat sources. Be careful with detergents. - Valvola EDF-6

NEVER remove a valve from piping or disassemble the valve, while under pressure. The permanent magnets mounted on the valve have a high magnetic field. Magnets should be handled carefully to avoid crushing of the fingers and any damage or injury. You must keep a safe distance between the magnets and all electrical and electronic equipment and objects that can be damaged by a magnetic field such as monitors, credit cards and ATMs, computers, diskettes and other data, mechanical clocks, lamps hearing and speakers. To avoid any risk, the staff arranges for the assembly / disassembly of the valve should not have the Pacemaker. handle. We must pay close attention when handling the magnets mounted on the valve, a breakage of the magnet itself can generate sharp and very small parts dangerous to We disclaim all responsibility for inappropriate installation, use and maintenance! 6. Technical Data Valve Use Application: For use in: operating pressure: 16 bar Non-return Valve Chemical, Pharmaceutical, Food, Vacuum system, Compressed air, Water treatment, Oil & Gas, Special applications MAX MAX temperature use: Standard Version 150 C High Temp Version 220 C MIN temperature use: -10 C Nominal conditions: Environmental temp. From 0 to +40 C Max humidity 10% - 90% Max altitude 1500 a.s.l. Materials Valve Body: 1.4404/1.4301 Shutter: 1.4462 Magnet: - Valvola EDF-7

Standard Version High Temp Version External Seals: Neodymium Samarium Cobalt EPDM Seals in contact with the product: EPDM: Excellent resistance to heat, weathering, good durability. Good compatibility with acids, alcohols, ketones and esters. Poor resistance to oils and fats. Temperature range: from -40 C to 160 C Silicone: Good resistance to animal and vegetable oils, resistance to oils, lubricants mediocre at aliphatic hydrocarbons, oil and gasoline, diluted alkali. Temperature range: from -60 C to 200 C NBR: Excellent resistance to oils and fats, minerals, plants, animals, aliphatic hydrocarbons. Alkali resistance. Unsuitable for use with amines, ketones, esters, ethers, benzene, chlorinated solvents and concentrated acids. Temperatura range: from -25 C to 125 C FPM(Viton): Excellent resistance to oils and greases, aliphatic hydrocarbons, aromatic hydrocarbons. Temperature range: from -20 C to 200 C FEP(PTFE): Excellent thermic and chemical properties. Practically insoluble at high temperatures, and acid resistant in temperature. Very low coefficient of friction but limited mechanical strength and wear. Temperature range: from -10 C to 200 C The parameters of application are considered in relation to a standard and proper use of equipment. To dispose of the components, refer to the local law in the Country where the valve has to be dismantled. Finishing surfaces Surfaces in contact with product: 0.4 µm < Ra < 3.2 µm Surfaces not in contact with product: 0.8 µm < Ra < 3.2 µm Installation position All installation positions are possible. Check the flow direction (see the mark on the valve). - Valvola EDF-8

7. Unpacking / Storage A B 1. Unpacking and checking the delivery valve: A. Complete valve. B. Instruction Manual. 1 2. Handling split parts: - Avoid dropping the product. - Check inside the valve. - Unpack and take the instructions for assembly / disassembly. 3. Control / complaints: - Document / verify damage, missing parts or wrong. - Contact Ygros srl, if necessary. 4. Storage / protection: - Avoid dust, humidity, wet areas, heat and the like. - Avoid vibration. - Temp Min:-10 C - Temp Max: +50 C 1 Dowloadable from www.ygros.com - Valvola EDF-9

8. Installation Instructions The valve should be installed at a safe distance from components that can lead to turbulent motions fluid through the valve. Turbulent motions can cause noise, vibration and cavitation with consequent wear of valve components. In this case, the installation position of the valve has to be modified. ALWAYS check before mounting, fluid chemical compatibility with the materials from which the valve (par. technical data) and seals/gasket. Install the valve due to distance from the external heat sources. Preferably, install the valve easily accessible and suitable for maintenance activities.. We strongly recommended that the fittings should be installed by specially trained, qualified personnel. Correct direction of flow: - Check the correct flow direction before installing the non-return valve. If the valve is welding type, to perform welding, the valve must be disassembled to prevent damage to seals and magnets. To disassemble the valve see par. Disassembly/Assembly. ALWAYS drain and bleed the system before installing the valve. Verify that the installation must be equipped with grounding. - Valvola EDF-10

9. Start-up After installing the valve and before starting the plant make sure which the valve is installed correctly and the arrow marked on the valve indicates the direction of flow. 10. Troubleshooting Be sure that nothing impedes the flow in the pipeline. Verify that the installation was successful before starting the installation pressure. TROUBLESHOOTING VALVE Please study the maintenance manual before searching. WEAR VALVE REPLACEMENT PARTS See par. Disassembly/Assembly. Problem Pssible cause Possible remedy External loss Body gaskets worn Replace gaskets Closed valve has an internal Loss caused by normal wear Closed valve has an internal loss incurred prematurely Excessive Pressure Excessive Temperature Shutter gasket worn Aggressive fluids Check the pressure of the installation (see par. Technical data usable) maximum pressure Replace with seal of different kinds of elastomers Replace gaskets. Change the operational conditions or replace the material of the seals Difficult opening and closing Incorrect Type elastomers seal Replace with seal of different kinds of elastomers Incorrect Shutter positioning Remove and reseat properly the shutter Valve noise during operation Cavitation or fluid turbulence Move the valve position - Valvola EDF-11

11. Cleanliness To clean the valve is necessary to disassemble the valve by following the instructions of par. Disassembly / Assembly, contained in this manual. CLEANING VALVE: - Enforce the cleaning of the valve by authorized personnel - Follow the indicated concentrations in detergents - Follow the instructions of the detergents suppliers - Always wear gloves and safety glasses. RISK DAMAGE ELASTOMERS WARM VALVE/PIPE: - If possible, do not touch the valve or piping hot. - Alternatively, wear protective gloves. HANDLING DETERGENTS: - Measure out the detergent to avoid excessive concentrations - Rinse thoroughly with clean water after cleaning - Check the materials compatibility of the valve. - Valvola EDF-12

12. Maintenance Before starting maintenance work to ensure that: The tubes are discharged liquids and / or residual pressure; Maintain ONLY with piping system NOT in pressure-free product; The staff is informed about the possible risks / hazards that may occur and take the necessary security measures; Assemble the valve following assembly instructions (see par. Disassembly / Assembly) REQUIRED AIR PRESSURE DANGER OF BURNS VALVE / PIPE UNDER PRESSURE : - Always discharge fluid pressure from the valve and the pipe before removing the valve. WARM VALVE / PIPE: - Possibly not touch the valve or piping hot - Alternatively, wear protective gloves. WASH AND THOROUGHLY CLEAN CLEANING: - Wash and thoroughly clean all parts of the valve before disassembling - Consider possible deposits of detergents and other aggressive residues within the valve; - Always use goggles and gloves. WEAR VALVE REPLACEMENT PARTS - Always use original spare parts. - To order parts contact Ygros Inc. or retailers with reference to the code marked on the valve. - Valvola EDF-13

13. Planned Maintenance Planned Maintenance Preventive In case of loss not dangerous (internal) Valve For the turbulent fluid motion and consequent noise valve, check daily (see possible remedy on par. Troubleshooting) Monthly control only in the case of use of particularly aggressive fluids Check at the end of the day any unusual wear Gasket Replace after 12 months Replace at the end of the day Periodic Check correct operation and leakage Check correct operation and leakage Record all actions Record all actions 14. Disassembly / Assembly Record the sections of the valve: the first with a single piece bolt, the second shutter into 2 parts. COMPONENTS: 1. Screw 2. Screw 3. Valve body 4. Front flange 5. Rear flange 6. Magnet 7. Gasket 8. O-Ring back 9. O-Ring shutter 10. O-Ring Front 11. Shutter - Valvola EDF-14

COMPONENTS: 1. Screw 2. Screw 3. Body front shutter 4. Rear body bolt 5. Valve body 6. Front flange 7. Rear flange 8. Magnet 9. Gasket 10. O-Ring back 11. O-Ring shutter 12. O-Ring Front WARNING PRESENCE OF PERMANENT MAGNET: To disassembly the valve pay attention to the presence of a permanent magnet and follow the instructions carefully. The permanent magnets mounted on the valve have a high magnetic field. It 'must be careful to avoid crushing of the fingers and any damage or injury. You must keep a safe distance between the magnets and all electrical and electronic equipment and objects that can be damaged by a magnetic field such as monitors, credit cards and ATMs, computers, diskettes and other data, mechanical clocks, lamps hearing and speakers. Pacemakers can be disturbed by the presence of a large magnet. To avoid any risk, so that a support staff that arranges for the assembly / disassembly of the valve. We must pay close attention when handling the magnets mounted on the valve, a breakage of the magnet itself can generate sharp and very small parts dangerous to handle. - Valvola EDF-15

Valve disassembly 1. REMOVING THE FRONT FLANGE Remove the screws (1), remove the front plate (2) and subsequently O-Ring (3) from valve body (6). 2. REMOVING THE REAR FLANGE Remove screws (11), then the rear flange (10) and later the O-Ring (9) from the valve body (6). THE MAGNET MAY BE REMOVED FROM THE VALVE ONLY WHEN ABSOLUTELY NECESSARY AND ONLY BY QUALIFIED PERSONNEL. WARNING PRESENCE OF PERMANENT MAGNET: The permanent magnets have a high magnetic field. It 'must be careful to avoid crushing of the fingers and any damage or injury. 3. REMOVAL OF MAGNET Remove the gasket (4) and then the two magnets (5). - Valvola EDF-16

speakers. You must keep a safe distance between the magnets and all electrical and electronic equipment and objects that can be damaged by a magnetic field such as monitors, credit cards and ATMs, computers, diskettes and other data, mechanical clocks, lamps hearing and Pacemakers can be disturbed by the presence of a large magnet. To avoid any risk, so that a support staff that arranges for the assembly / disassembly of the valve. We must pay close attention when handling the magnets mounted on the valve, a breakage of the magnet itself can generate sharp and very small components dangerous to handle. Shutter disassembly 4.A IN CASE OF ONE-PIECE SHUTTER Pull the shutter (8) from valve body (6) and remove the O-Ring (7). To remove the OR is necessary to cut it. 4.B IN CASE OF TWO PARTS SHUTTER Remove the shutter (11-12) from the valve body (6), divide both sides shutter loosen and remove the O-Ring (7). - Valvola EDF-17

Shutter Assembly 1.A ASSEMBLY OF ONE PIECE SHUTTER Pre-heat the O-ring shutter (7) at about 70 C to soften it and place it in the cracks shutter (8). Insert the ring at crossing by pressing a plastic cylindrical tool. 1.B ASSEMBLY OF TWO PIECES SHUTTER Mount O-Ring (7) on the body front shutter (11) and screw it into the rear body shutter (12) to bring the upper body (11) in mechanical stop on the rear body (12). 2. INSERT SHUTTER IN VALVE BODY Insert the shutter (8) complete with O-ring (7) into the valve body (6). 3. ASSEMBLY MAGNET Place the two magnets (5) on the valve body (6) following the instructions prescribed in this manual and place the outer gasket (4). - Valvola EDF-18

WARNING PRESENCE OF PERMANENT MAGNET : FOR THE MAGNET ASSEMBLY, FOLLOW THE SAFETY INSTRUCTION IN THE par. DISASSEMBLY/ASSEMBLY. Valve Assembly 4. ASSEMBLY REAR FLANGE Ensure that the shutter inside the valve body (6). Place the O-ring (9) on the valve body (6) and push the rear flange (10) on valve body (6) taking care not to pinch the OR (9), secure the rear flange (10) on body valve (6) through screws (11). 5. ASSEMBLY FRONT FLANGE Place the O-ring (3) on the valve body (6) and push the front flange (2) on the valve body (6) taking care not to pinch the rings (3), attach the front flange (2) through the screws (1). Tighten the screws with a torque wrench as defined in Table for screws in A2 stainless material, which is given also below: M4= 2.6 Nm M5= 5.1 Nm M6= 8.8 Nm M8=21.4 Nm - Valvola EDF-19

15. Warranty 1. CONVENTIONAL GUARANTEE 1.1. YGROS srl warrants its products against possible defects in construction and operation and bad material for 12 (twelve) months from the date of delivery. 1.2. The defects and / or product defects must be reported accurately in writing YGROS srl within 8 (eight) days of discovery, with proper documentation proving the allegation of their existence. 2. EXCLUSION OF WARRANTIES 2.1. Detain and affect any rights which the purchaser by mandatory provisions of law, are excluded from the guarantee provided elastomers. 2.2. It also excluded the application of the guarantee: - Defects and/or damages attributable to Buyer and due to the same mode of use or maintenance or storage of products not meeting the requirements of "Instruction manual use and maintenance ; - Defects and/or damages due to normal wear and tear, or parts thereof and / or components; - Defects and/or damages if the product were carried out repairs and / or intervention by anyone not authorized by YGROS srl professionally qualified or not; - Defects due to falls, collisions, abuse, accidents caused by negligence of Buyer. 3. CONTENT OF THE GUARANTEE 3.1. This warranty is only in the repair and/or replacement, at the discretion of YGROS srl, product or part of the approved product /s defect /s. 3.2. In the case of repair and/or replace the product or its component, the parties have become the property of YGROS srl and the cost of return shall be borne by YGROS srl. 3.3. In any case, YGROS srl, will not be obligated to repair or indirect and intangible damage shall under no circumstances be liable for damages and/or indirect or consequential losses which are merely examples, damages for any loss of business opportunities, time, production, profits, and goodwill or damage its image. 3.4. The services performed under warranty does not entail an extension of the warranty period beyond the period of 12 (twelve) months, a term which shall be deemed exhaustive. 3.5. No dealer, agent or employee of YGROS srl, is authorized to make any modification, extension or addition to this guarantee. - Valvola EDF-20

16. Recommendations 1. All statements, claims, and the news given herein are based on test data which are deemed reliable, but not due to any possible use of the product. Since conditions of use and application are beyond our control, the Buyer must first establish the suitability of the product for which you will support, assuming all risk and liability arising from the use itself. YGROS srl assumes no responsibility for any accident, loss or damage, direct or consequential loss arising from the use or inability to use the product. No one is authorized to issue loan guarantees greater than or different from those shown here. 2. Recommend our customers to always consult our technical and commercial staff to request specific information about the technical characteristics of our products. 3. Representations, all of general value and not binding, may not correspond to the real conditions of the products. 4. Reported in this publication refers to products of our normal production and in no case be a basic reference for products made to specific requests. 5. YGROS srl is not responsible for flaws or defects arising from installation of the product according to what is stated in the "Use and Maintenance Instruction Manual" or otherwise arising from improper installation or improper or incorrect use and/or improper product. 6. YGROS srl is not responsible for defects and / or product defects resulting from improper transport and/or arising from improper and/or unsuitable storage and/or maintenance of the same. 7. YGROS srl is not liable for defects and/or defects in the product due to tampering and/or interventions conducted by unqualified personnel, professionally, and it is not liable for damage caused by bumps, bruised, carelessness, negligence, and usually causes no fault defects in construction, manufacturing and material defects. - Valvola EDF-21