JRG Valves JRGUTHERM. Thermostatic flow regulator with threaded shut-off connections

Similar documents
THE WORLD COMPETITIVENESS SCOREBOARD 2011

Max Sort Sortation Option - Letters

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Welcome to KNX Scientific Conference 2012 Las Palmas Gran Canaria Watch how international KNX has become!

I. World trade in Overview

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Airfix Pressure expansion vessels for sanitary appliances and potable water systems

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

By-pass valves Series 466 Thermatic - Series USVR

JRGURED Pressure reducing valves

NITROGEN CHARGING KIT type PC 11.1 E 01-12

NITROGEN CHARGING KIT type PC 11.1 E 04-11

Global Construction Outlook: Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009

Update of trade weights data underlying the EERs and HCIs

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

ASB Accumulator Safety Blocks

HydroCOM: High energy savings and excellent controllability

User Guide for the Sterile Cord Blood Collection Unit

AVP-F. p setting range (bar) Code No. 003H6200

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

TERMINAL BLOCK SUMMARY

Demography Series: China

OECD employment rate increases to 68.4% in the third quarter of 2018

Masoneilan * DSH * Series Desuperheater

Product Date Code Beginning With L4171 A 8/2016 O, A NOTICE:

DIAPHRAGM GAS SAMPLING PUMPS

Masoneilan* 78 Model Air Filter Regulator

Masoneilan* Model 78-80H & 08-80H Transfer Valves

Firearms & parts firearms & parts firearms & parts rocket launcher components

2-port and 3-port valves PN 16

2-port seat valves PN25 with externally threaded connections

Finance Domain Task Force

Two-port valves, male threaded, PN25

January Deadline Analysis: Domicile

I N T E R N A T I O N A L S K A T I N G U N I O N

Value Exported (CDN$) Support Systems ,165 firearms ,389 firearms ,465 firearms ,500 rocket launchers

Seated valves VRB 3, VRG 3

Medium-sized vessels water connection. White paper

USTA Player Development 2017 Excellence Grant Criteria Jr Girls, Collegiate & Professional Players

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Post Show Report April 2015, Moscow, Russia. #ipheb

Happiness trends in 24 countries,

European Values Study & World Values Study - Participating Countries ( )

Automatic balancing valves ASV

Confidence through experience. Track record as of 30 June 2012

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

UPB All fluids. Full flow All stainless steel

I N T E R N A T I O N A L S K A T I N G U N I O N

Marsh & McLennan Companies Entities Covered by the BCRs

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Automatic balancing valves ASV

Portuguese, English, and. Bulgarian, English, French, or

June Deadline Analysis: Domicile

FIL Qualifying Event Proposal. Problem Statement. Proposal for voting at GA

Principal Operations in Japan

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Stockholm s tourism industry. November 2016

CMMI Maturity Profile Report. 30 June 2017

UPA All fluids. Full flow All stainless steel

INTERNATIONAL SKATING UNION

Radiator valves VDN1.. VEN1..

Stockholm s tourism industry. December 2016

HERZ-Motorised flow controler

Masoneilan* Model 78-80S & 08-80S Transfer Valves

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

UPA All fluids. Full flow All stainless steel

The 11th Korea Prime Minister Cup International Amateur Baduk Championship

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

2018 Hearthstone Wild Open. Official Competition Rules

IR-Pay Go Rates. There are three pricing groups for Pay Go rates for International Roaming as follows:

Full-Time Visa Enrolment by Countries

The globalisation of sporting events: Myth or reality?

Table I. NET CALORIFIC VALUES OF ENERGY PRODUCTS GJ/ton

2-Port and 3-Port Seat Valves with Female Thread, PN16

STAD-C. Balancing valves DN 15-50

INTERNATIONAL STUDENT STATISTICAL SUMMARY Spring 2017 (Final)

INSTALLATION INSTRUCTIONS

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

Table I. NET CALORIFIC VALUES OF ENERGY PRODUCTS GJ/ton

TABLE 1: NET OFFICIAL DEVELOPMENT ASSISTANCE FROM DAC AND OTHER DONORS IN 2012 Preliminary data for 2012

CONTRIBUTING OIL RECEIVED IN THE CALENDAR YEAR 2016

STAP. Differential pressure controller DN 15-50

CALEFFI. Ball zone valves. series /03 GB

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

New rules, new opportunities: a potential for growth

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

2-port and 3-port seat valves, PN16

German Machine Tool Industry - Key Figures

VZL valve - 2/3/4-way

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Marsh & McLennan Companies Entities Covered by the BCRs

Radiator valves VDN2.. VEN2.. VUN2..

PVM 15-50, differential pressure valves

Transcription:

JRG Valves JRGUTHERM Thermostatic flow regulator with threaded shut-off connections

Structure 1 2 3 4 1 Scale ring 2 Body, gunmetal 3 Regulator sleeve, gunmetal 4 O-Ring, EPDM 5 Thermostat 6 Spring-loaded pin, brass 7 Regulator body, POM 8 Working spring 5 6 7 8 Planning instruction Even with self-regulating circulation regulators such as the JRGUTHERM, it is necessary to configure the system simply. Recommended temperature spreading water heater JRGUTHERM: 2 5 K. In order to select the suitable pump, the discharge flow of the entire system has to be determined. The delivery height is calculated from the pressure loss of the least favourable pipe line (flow way). The pressure loss of the JRGUTHERM in this pipe line is measured on the k Vmax line on the diagram. The pump performance of excessively strong pumps are to be throttled at the pump. The JRGUTHERM must not be used to throttle the pump (maximum differential pressure = 0.4 bar). The regulators in the remaining pipe lines are to be selected in such a way that the intersection of the flow rate and the necessary pressure drop lies within the interpretation field. In the appropriate configuration, with the most unfavourable flow way, the installation of a JRGUTHERM flow regulator can be avoided or it can be replaced by a mechanical throttle e.g. JRG Code 6310 6317. A JRGUTHERM is to be integrated into all circulation outlets. If there is any danger of the water flowing through the JRGUTHERM flow regulator in the wrong direction, this is to be avoided by the installation of suitable non-return valves. We recommend the installation of JRG Code 8208 screw connections with non-return valves. For questions and information on application technology, please contact our technical advisors or the technical customer service. 2

Function/Installation position Function The JRGUTHERM flow regulator regulates the flow volume by permanently sensing the water temperature with a thermostat. The hydraulic calibration is thus automatically established. By using the appropriate threaded shut-off connections, non-return valves and shut-off can be directly integrated. Materials All water-conducting components are made of gunmetal, copper, stainless steel or high-grade plastic. JRGUTHERM advantages Simplifies flow calculations No setting up calculations Simple regulator operation Maintenance-free Automatic adjustment of the flow volume (hydraulic balance) Shorter heat-up phase after temperature drop Energy saving Installation position The JRGUTHERM flow regulator can be installed in any position. We recommend that, for revision purposes, JRG Code 8339 threaded shut-off connections has to be installed before and after the flow regulator. Area of application Setting range 36-63 C Maximum temperature load 70 C Maximum operating pressure PN 10 Maximum differential pressure 40 kpa (0,4 bar) The JRGUTHERM flow regulator is protected from overheating. The JRGUTHERM flow regulator is to be fitted with a bypass for thermal disinfection. The JRGUTHERM flow regulator is not suitable for use in gravity circuits. 3

Pressure loss JRGUTHERM 6320.914 ½ 0.5 0.4 k V min. 0.15 m 3 /h optimum area k V max. 1.15 m 3 /h 0.3 0.2 Pressure loss Δp [bar] 0.1 0.08 0.06 0.04 0.03 0.02 Pressure loss Δp [kpa] 0.001 Flow volume V (l/h) JRGUTHERM 6320.924 ¾ 0.5 0.4 0.3 0.2 k V min. 0.20 m 3 /h k V max. 2.00 m 3 /h optimum area Pressure loss Δp [bar] 0.1 0.08 0.06 0.04 0.03 0.02 Pressure loss Δp [kpa] 0.001 Flow volume V (l/h) 4 Maximum admissible differential pressure 0.4 bar!

Sample of installation upper distribution pipe on pipe conventional m 3 single circulation DIN Text JRG Code SIA TWK cold water WKR TWW hot water WWV TWZ circulation WW WWR Stop valve 5000-31 Non-return valve 1640-66 Swing check valve 1682 Adjustable socket 6310 JRGUTHERM flow regulator 6320 Circulation pump Drain cock 6000-12 Circulation collector 5560 Water meter 5450 m 3 Ball valve 6020/23 5

JRGUTHERM/Screw connections h JRGUTHERM flow regulator PN 10 For hot water circuits, thermostatically regulated, gunmetal body with external threads, regulator sleeve with hexagon socket for angular Allen key and scale ring. l 3 d 1 d 1 l l 1 Factory-set to 57 C, scale value 6 Setting range 36 63 C Max. temperature load 70 C Max. operating pressure PN 10 Max. differential pressure 0.4 bar Accessories Threaded shut off connection 8339 Unions with non-return valve 8208 The flow regulator packing material serves as heat insulation. The JRGUTHERM is to be fitted with a bypass for thermal disinfection. The flow regulator is not suitable for use in gravity circuits. l 2 b 1 b 1 JRG Code GF Code GN DN d1 h l l1 l2 l3 b1 kg 6320.914 350831401 ½ 15 G ¾ 64 60 194 38 70 37 8 0.350 6320.924 350831501 ¾ 20 G 1 64 60 194 38 70 37 8 0.380 d 1 2 3 1 d 2 Threaded shut off connection, PN 10 Made of gunmetal, with internal thread, lockable with ball valve, EPDM seal, loose brass nut, for water up to 70 C, suitable for flow regulator JRGUTHERM 6320. l z JRG Code GF Code GN DN d1 d2 l 1 2 3 z kg 8339.240 350887710 ½ 15 Rp ½ G ¾ 55 30 27 6 43 0.170 8339.320 350887911 ¾ 20 Rp ¾ G 1 55 37 32 6 47 0.200 1 2 d 2 d 1 Union with Non-return valve Made of brass, with external thread and plastic non-return valve (PSU) with EPDM seal, suitable for flow regulator JRGUTHERM 6320. l 2 l 1 l JRG Code GF Code GN DN d1 d2 l l 1 l 2 1 2 kg 8208.240 351055901 ½ 15 Rp ½ G ¾ 42 34 8 30 19 0.090 8208.320 351056001 ¾ 20 Rp ¾ G 1 45.5 37 8.5 37 24 0.130 6

Adjustment/Setting ranges of the JRGUTHERM flow regulator Setting of the flow regulator All flow regulators built into the system must be adjusted to the same scale values. A step less adjustment is possible. The settings value are shown in the table. The calibration of the individual circulation lines takes place automatically. Transport packing Adjusting the flow regulator Changing the factory setting is done exclusively on the responsibility of the person who undertakes it. The factory setting of the JRGUTHERM flow regulator can be changed as follows: Put Allen key into the hexagon socket. Turning the key clockwise lowers the temperature, turning it anticlockwise raises it. JRGUTHERM scale value Circulation set point value 1 36 C 2 41 C 3 45 C 4 49 C 5 53 C 6 (factory setting) 57 C 7 63 C The transport packing of the JRGUTHERM flow regulator serves as thermal insulation after assembly and setting. Maintenance The JRGUTHERM flow regulator operates largely maintenance-free. The assembly and operating instructions supplied are to be given to the owner on delivery of the equipment. 7

GF Piping Systems Worldwide at home Our sales companies and representatives ensure local customer support in over 100 countries. www.gfps.com Argentina / Southern South America Georg Fischer Central Plastics Sudamérica S.R.L. Buenos Aires, Argentina Phone +54 11 4512 02 90 Fax +54 11 4512 02 93 gfcentral.ps.ar@georgfischer.com www.gfps.com/ar Australia George Fischer Pty Ltd Riverwood NSW 2210 Phone +61 (0) 2 9502 8000 Fax +61 (0) 2 9502 8090 australia.ps@georgfischer.com www.gfps.com/au Austria Georg Fischer Rohrleitungssysteme GmbH 3130 Herzogenburg Phone +43 (0) 2782 856 43 0 Fax +43 (0) 2782 856 64 austria.ps@georgfischer.com www.gfps.com/at Belgium / Luxembourg Georg Fischer NV/SA 1600 Sint-Pieters-Leeuw / Belgium Phone +32 (0) 2 556 40 20 Fax +32 (0) 2 524 34 26 be.ps@georgfischer.com www.gfps.com/be Brazil Georg Fischer Sist. de Tub. Ltda. 04571-020 São Paulo/SP Phone +55 (0) 11 5525 1311 br.ps@georgfischer.com www.gfps.com/br Canada Georg Fischer Piping Systems Ltd Mississauga, ON L5T 2B2 Phone +1 (905) 670 8005 Fax +1 (905) 670 8513 ca.ps@georgfischer.com www.gfps.com/ca China Georg Fischer Piping Systems Ltd 201319 Shanghai Phone +86 21 3899 3899 Fax +86 21 3899 3888 china.ps@georgfischer.com www.gfps.com/cn Denmark / Iceland Georg Fischer A/S 2630 Taastrup, Denmark Phone +45 (0) 7022 1975 Fax +45 (0) 7022 1976 info.dk.ps@georgfischer.com www.gfps.com/dk Finland Georg Fischer AB 01510 Vantaa Phone +358 (0) 9 586 58 25 Fax +358 (0) 9 586 58 29 info.fi.ps@georgfischer.com www.gfps.com/fi France Georg Fischer SAS 95932 Roissy Charles de Gaulle Cedex Phone +33 (0) 1 41 84 68 84 Fax. +33 (0) 1 41 84 68 85 fr.ps@georgfischer.com www.gfps.com/fr Germany Georg Fischer GmbH 73095 Albershausen Phone +49 (0) 7161 302 0 Fax +49 (0) 7161 302 25 9 info.de.ps@georgfischer.com www.gfps.com/de India Georg Fischer Piping Systems Pvt. Ltd. 400 076 Powai, Mumbai Phone +91 22 4007 2000 Fax +91 22 4007 2020 branchoffice@georgfischer.com www.gfps.com/in Indonesia George Fischer Pte Ltd 41371 Jawa Barat Phone +62 267 432 044 Fax +62 267 431 857 indonesia.ps@georgfischer.com www.gfps.com/id Italy Georg Fischer S.p.A. 20063 Cernusco S/N (MI) Phone +39 02 921 86 1 Fax +39 02 921 86 24 7 it.ps@georgfischer.com www.gfps.com/it Japan Georg Fischer Ltd 530-0003 Osaka Phone +81 (0) 6 6341 2451 jp.ps@georgfischer.com www.gfps.com/jp Korea Georg Fischer Piping Systems 463-824 Seoul Phone +82 31 8017 1450 3 Fax +82 31 8017 1454 kor.ps@georgfischer.com www.gfps.com/kr Malaysia George Fischer (M) Sdn. Bhd. 40460 Shah Alam, Selangor Darul Ehsan Phone +60 (0) 3 5122 5585 Fax +60 (0) 3 5122 5575 my.ps@georgfischer.com www.gfps.com/my Mexico / Northern Latin America Georg Fischer S.A. de C.V. Apodaca, Nuevo Leon, Mexico Phone +52 (81) 1340 8586 Fax +52 (81) 1522 8906 mx.ps@georgfischer.com www.gfps.com/mx Middle East Georg Fischer Piping Systems (Switzerland) Ltd Dubai, United Arab Emirates Phone +971 4 289 49 60 Fax +971 4 289 49 57 gss.ps@georgfischer.com www.gfps.com/int Netherlands Georg Fischer N.V. 8161 PA Epe Phone +31 (0) 578 678 222 Fax +31 (0) 578 621 768 nl.ps@georgfischer.com www.gfps.com/nl New Zealand Georg Fischer Ltd 5140 Upper Hutt Phone +64 (0) 4 527 9813 Fax +64 (0) 4 527 9834 nz.ps@georgfischer.com www.gfps.com/nz Norway Georg Fischer AS 1351 Rud Phone +47 67 18 29 00 Fax +47 67 13 92 92 no.ps@georgfischer.com www.gfps.com/no Philippines George Fischer Representative Office 1604 Pasig City Phone +632 571 2365 Fax +632 571 2368 sgp.ps@georgfischer.com www.gfps.com/sg Poland Georg Fischer Sp. z o.o. 05 090 Sekocin Nowy Phone +48 (0) 22 3131 050 Fax +48 (0) 22 3131 060 poland.ps@georgfischer.com www.gfps.com/pl Romania Georg Fischer Rohrleitungssysteme (Elvetia) S.A. SUCURSALA BUCURESTI 020257 Bucuresti Phone +40 311 040 492 Fax +40 212 317 479 ro.ps@georgfischer.com www.gfps.com/int Russia Georg Fischer Piping Systems (Switzerland) Ltd Moscow Representative Office 125040 Moscow Phone +7 495 748 11 44 ru.ps@georgfischer.com www.gfps.com/ru Singapore George Fischer Pte Ltd 528 872 Singapore Phone +65 6747 0611 Fax +65 6747 05 77 sgp.ps@georgfischer.com www.gfps.com/sg Spain / Portugal Georg Fischer S.A. 28046 Madrid Phone +34 (0) 91 781 98 90 Fax +34 (0) 91 426 08 23 es.ps@georgfischer.com www.gfps.com/es Sweden Georg Fischer AB 11743 Stockholm Phone +46 (0) 8 506 77 50 0 Fax +46 (0) 8 749 23 70 info.se.ps@georgfischer.com www.gfps.com/se Switzerland Georg Fischer Rohrleitungssysteme (Schweiz) AG 8201 Schaffhausen Phone +41 (0)52 631 3026 Fax +41 (0)52 631 2800 ch.ps@georgfischer.com www.gfps.com/ch Taiwan Georg Fischer Co. Ltd. 24158 New Taipei City Phone +886 2 8512 2822 Fax +886 2 8512 2823 tw@georgfischer.com www.gfps.com/tw Turkey Georg Fischer Hakan Plastik Boru ve Profil San. Tic. A.S. 59500 Cerkezkoy / Tekirdag Phone +90 282 726 64 43 Fax +90 282 726 94 67 hpsales@hakan.com.tr www.hakan.com.tr United Kingdom / Ireland George Fischer Sales Ltd CV2 2ST Coventry, United Kingdom Phone +44 (0) 2476 535 535 Fax +44 (0) 2476 530 450 uk.ps@georgfischer.com www.gfps.com/uk USA /Caribbean Georg Fischer LLC 92618 Irvine Phone +1 714 731 88 00 Fax +1 714 731 62 01 Toll Free 800/854 40 90 us.ps@georgfischer.com www.gfps.com/us International Georg Fischer Piping Systems (Switzerland) Ltd 8201 Schaffhausen Phone +41 (0) 52 631 3003 Fax +41 (0) 52 631 2893 info.export@georgfischer.com www.gfps.com/int The technical data are not binding. They neither constitute expressly warranted characteristics nor guaranteed properties nor a guaranteed durability. They are subject to modification. Our General Terms of Sale apply. 37 237 62 e (1.17) SMS Georg Fischer JRG AG Hauptstrasse 130 CH-4450 Sissach/Switzerland Telefon +41 (0) 61 975 22 22 info.jrg.ps@georgfischer.com Printed in Switzerland