Gas Switching Accessory

Similar documents
SC505 Sof Care Inflator. Operating Instructions and Service Manual

Pressure Automated Calibration Equipment

INSTALLATION GUIDE Gas Rangetops

5 Channel Calibrator

Instructions for Cleaning & Maintaining Air Compressor

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Liquid Nitrogen Cooling Accessory CE

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

NGP-250/500 Nitrogen Generator Quick Start Guide

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

Discovery HP-TGA 75/750. Site Preparation Guide

Workhorse-15 Oxygen Generator

Inert Air (N2) Systems Manual

6890 GC Site Preparation

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Operating Instructions

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Agilent Auxiliary Gas Module AGM 2. User s Guide

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

CAPITAL CONTROLS SERIES NXT3000

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Operating Instructions Part No

TA Instruments Installation Requirements for the Thermal Discovery Series

Pressure Dump Valve Service Kit for Series 3000 Units

UltraLo 1800 Alpha Particle Counter

Customer Responsibilities

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

TOMAHAWK 1025 & 1538 OPERATOR S MANUAL IM /2016 REV06 ENGLISH

Operating Instructions Part No

Nitrogen Tyre Inflator Owner s Manual

RPS900W Redundant Power Supply. Installation Guide.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Domiciliary Oxygen Switch. Instructions for Use

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

DPC-30 DPC-100. Reference Manual

MEDICAL EQUIPMENT CATALOG

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Pressure Dump Valve Service Kit for Series 2300 Units

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

MANUAL BE SERIES Test Benches

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Pressure Injection Cell Operator s Manual

with O 2 Controller Instruction Manual

Dual Solenoid Gas Valve Installation

2010 Technical Education. Topics to be covered: Set Up. Training Manual Overview Set Up / Specifications & Preventive Maintenance

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

DSC Differential Scanning Calorimeter

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

User and Installation Manual

Supplementary Operator s Manual 42/24-14 EN Rev. 3

VACUUM REGULATORS CONTENTS

Rejuvenation Instructions

In Vivo Scientific, LLC INSTRUCTION MANUAL

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

Autocalibration Systems For In Situ Oxygen Analyzers

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

1 DRIVE INDUSTRIAL IMPACT WRENCH

BGA244 Binary Gas Analyzer

100C Air Compressor Kit

Columbus Instruments

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

The SAV04 Small Animal Ventilator. Contents Page

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Setup Guide for your HVO Naked Drone

TECHNICAL DATA. Trimpac 244a. September 16, 2013

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

! Warning, refer to accompanying documents.

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

BP Controller 300 PSI

IMPORTANT SAFETY INSTRUCTIONS

Norrsken Family Booklet

Model 130M Pneumatic Controller

Hallowell EMC Anesthesia WorkStation Operating Manual

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Oxygen Dialflow Meter. Instructions for Use

User Manual. Quantos Automated Dosing Liquid Module

Transcription:

109 Lukens Drive New Castle, DE 19720 Thermal Analysis & Rheology A SUBSIDIARY OF WATERS CORPORATION Gas Switching Accessory Operator's Manual PN 992305.001 Rev. B Issued August 1999 TA INSTRUMENTS GAS SWITCHING ACCESSORY 1

Gas Switching Accessory 1997, 1999 by TA Instruments, Inc. 109 Lukens Drive New Castle, DE 19720 Notice The material contained in this manual is believed adequate for the intended use of this instrument. If the instrument or procedures are used for purposes other than those specified herein, confirmation of their suitability must be obtained from TA Instruments. Otherwise, TA Instruments does not guarantee results and assumes no obligation or liability. This publication is not a license to operate under or a recommendation to infringe upon any process patents. TA Instruments TA Operating System, Instrument, Data Analysis, and Utility Software and their associated manuals are proprietary and copyrighted by TA Instruments, Inc. Purchasers are granted a nonexclusive, nontransferable license to use these software programs on the instrument and controller with which they were purchased. These programs may not be duplicated by the purchaser without the prior written consent of TA Instruments. Each licensed program shall remain the exclusive property of TA Instruments, and no rights or licenses are granted to the purchaser other than as specified above. 2 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Table of Contents Table of Contents Notes, Cautions, and Warnings...4 Ordering Information...5 Safety...7 CE Compliance...7 Electrical Safety...8 Operating Safety...8 Introducing the GSA...9 Description...9 Specifications...11 Principles of Operation...12 Auto Mode...12 Manual Mode...13 Installing the GSA...15 Unpacking the GSA...15 Choosing a Location...15 Connecting the GSA...16 Operating the GSA...20 The GSA Front Panel...20 The GSA Rear Panel...22 Using the GSA...23 Maintaining the GSA...25 Fuse Replacement...25 TA INSTRUMENTS GAS SWITCHING ACCESSORY 3

Gas Switching Accessory Notes, Cautions and Warnings This manual uses Notes, Cautions, and Warnings to emphasize important and critical instructions. NOTE: A NOTE highlights important information about equipment or procedures. t CAUTION: A CAUTION emphasizes a procedure that may damage equipment or cause loss of data if not followed correctly.!warning A WARNING indicates a procedure that may be hazardous to the operator or to the environment if not followed correctly. 4 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Ordering Information Ordering Information TA Instruments, Inc. 109 Lukens Drive New Castle, DE 19720 Telephone: 1-302-427-4000 or 1-302-427-4040 Fax: 1-302-427-4001 HELPLINE U.S.A. For technical assistance with current or potential thermal analysis applications, please call the Thermal Analysis Help Desk at 1-302-427-4070. SERVICE U.S.A. For instrument service and repairs, please call 1-302-427-4050. TA Instruments Ltd. Europe House, Bilton Centre Cleeve Road Leatherhead, Surrey KT22 7UQ England Telephone: 44-1372-360363 Fax: 44-1372-360135 TA Instruments GmbH Max-Planck-Strasse 11 D-63755 Alzenau Germany Telephone: 49-6023-9647-0 Fax: 49-6023-9647-77 TA Instruments Benelux Ottergemsesteenweg 461 B-9000 Gent Belgium Telephone: 32-9-220-79-89 Fax: 32-9-220-83-21 TA INSTRUMENTS GAS SWITCHING ACCESSORY 5

Gas Switching Accessory TA Instruments Japan No. 5 Koike Bldg. 1-3-12 Kitashinagawa Shinagawa-Ku, Tokyo 140 Japan Telephone: 813/3450-0981 Fax: 813/3450-1322 TA Instruments France B.P. 608 78056 Saint-Quentin-Yvelines Cedex France Telephone: 33-1-30-48 94 60 Fax: 33-1-30-48 94 51 TA Instruments Spain Waters Cromatografía, S.A. División TA Instruments Avda. Europa, 21. Pta. Baja 28108 Alcobendas Madrid, Spain Telephone: 34-91-661-8448 Fax: 34-91-661-0855 TA Instruments Australia Unit 3 38-46 South Street Rydalmere NSW 2116 Autstralia Telephone: 61-29-9331-705 Fax: 61-29-8981-455 Printed in U.S.A. TA Instruments Italy Division of Waters SpA via Achille Grandi 27 20090 Vimodrone (MI), Italy Telephone: 39-02-27421-1 Fax: 39-02-250-1827 6 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Safety Safety Read this section and understand the Safety precautions before proceeding with installing or using the GSA. This accessory has been designed to comply with the following standards on safety: IEC 1010-1/1990, A1/1992, and A2/1995 IEC 1010-2-010/1992, A1/1996 UL 3101-1, First Edition. CE Compliance In order to comply with the requirements of Council Directive 89/336/EEC (EMC Directive) and Directive 73/23/EEC (Low Voltage Directive), as amended by 93/68/EEC, the following specifications apply to the Gas Switching Accessory: Safety: EN 61010-1/1993 and A2/1995 EN 61010-2-010/1994 Emissions: EN 55022:1995, Class B (30-1000 MHz) Radiated EN 55022:1995, Class B (0.15-30 MHz) Conducted Immunity: EN 50082-1: 1992, Electromagnetic Compatibility Generic immunity standard Part 1. Residential, commercial, and light industry. IEC 801-2: 1991. Electrostatic Discharge. IEC 801-3: 1984. Radiated RF Immunity. IEC 801-4: 1988. Electric Transients. TA INSTRUMENTS GAS SWITCHING ACCESSORY 7

Gas Switching Accessory Electrical Safety Voltages up to 120 Vac are present in this system. Always disconnect the unit from the power source before performing any maintenance.!warning DO NOT REMOVE THE CABINET COVERS. Dangerous voltages are present in this instrument. Repair procedures requiring internal access to this compartment must be performed only by TA Instruments or other qualified service personnel. Operating Safety When operating the GSA, keep in mind that the maximum pressure allowable is 138 kpa (20 psi), using the following gases: nitrogen, oxygen, air, helium, or argon. If you want to use any other gases, contact the TA Instruments HelpLine for information.!warning When using oxygen with the GSA, you must be able to minimize the buildup of oxygen in order to avoid a fire hazard. We recommend that you either direct the vent gas to an exhaust system or operate in an environment that has adequate ventilation to ensure sufficient dilution. 8 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Introducing the GSA Introducing the GSA The TA Instruments Gas Switching Accessory (GSA) allows you to manually or automatically switch purge gases during your experiments. It can be used with any of the appropriate Thermal Analysis instruments. This manual provides the information necessary to understand, install, operate, maintain, and order parts for the TA Instruments Gas Switching Accessory (PN 992300.901). NOTE: Specifications in this manual are given in the International System of Units (Sl), with English equivalents in parentheses. Description The Gas Switching Accessory is a solenoidcontrolled gas manifold which enables selective switching between two purge gases. The GSA has two modes of operation, automatic and manual. In the AUTO(matic) mode the GSA is controlled with a contact closure in the thermal analyzer through an interconnecting cable. The MANUAL mode permits operator control of the gas switching by a front panel switch. See Figure 1 for an illustration of the front panel. See page 17 for operation of the front panel. TA INSTRUMENTS GAS SWITCHING ACCESSORY 9

Gas Switching Accessory Figure 1 Gas Switching Accessory Front Panel The rear panel of the Gas Switching Accessory, shown in Figure 2, provides entry connections for two purge gases, an exit gas connection to the instrument, an exhaust vent connection, two electrical input connectors for automatic activation/deactivation of the solenoid manifold, power switch, and a power entry instrument AC-line connector. 50 ma 250 V 35 ma Figure 2 Gas Switching Accessory Rear Panel 10 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Introducing the GSA Specifications The specifications for the Gas Switching Accessory are found in the table below. Table 1 GSA Technical Specifications Dimensions Depth: 25.4 cm (10") Width: 21.6 cm (8.5") Height: 11.4 cm (4.5") Power Requirements 120 Vac + 10 %, 50/60 Hz Weight Energy Consumption Control Fuse Type Flow Rate Automatic Gas Control Maximum Pressure Relief Valves 2.9 kg (6.4 lb) 4.2 watts Front panel switch selection. Rear panel remote, J2, J3. 35 ma, Type T, 250 V Up to 1 L/min Input jacks located on rear panel of GSA 138 kpa (20 psi) Both input lines have a 175 kpa (25 psi) pressure relief valve. Operating 15 to 30 C Temperature TA INSTRUMENTS GAS SWITCHING ACCESSORY 11

Gas Switching Accessory Principles of Operation Two solenoid valves and two metering valves are the main elements of the Gas Switching Accessory. A printed circuit board is used to control the solenoid valves. Two purge gases, designated as GAS 1 and GAS 2, are admitted to the gas switching accessory through two separate inlet ports. One gas flows from the INSTRUMENT port to the instrument. The second, unused gas flows out the VENT port to an exhaust system. Gas switchover is accomplished by electrically activating the solenoid valves. The next two sections provide general information on the two modes of operation: automatic and manual. For details on operating the GSA turn to page 20. Auto Mode If you want to program gas selection into an experimental method automatically, through the use of the instrument control software, you will first need to place the GSA in automatic mode. To do this, push the OPERATION pushbutton switch on the GSA front panel until it is in the AUTO mode. When the accessory is in the AUTO mode, activation of the solenoid valves is accomplished by means of contact closure (completion of the circuit) in the thermal analyzer. 12 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Introducing the GSA When the gas solenoid valves are deactivated: GAS 1 flows to the INSTRUMENT port GAS 2 flows to the VENT port. Conversely, when the solenoid valves are activated: GAS 2 flows to the INSTRUMENT port GAS 1 flows to the VENT port. GAS 1 may also be directed to the INSTRU- MENT port by disconnecting the contact closure cable. After the GSA is in automatic mode, you can turn purge gas 1 and 2 on or off using the Instrument Control software. See the software s online documentation for information on how to include gas control in an experimental method, if desired. Manual Mode If you want to manually choose a particular purge gas flow to the instrument, you can switch to MANUAL mode by following these steps: 1. Push the OPERATION pushbutton switch so that it is in the MANUAL position. This will override the automatic operation. 2. Use the SELECT pushbutton switch to choose either GAS 1 or GAS 2 to flow to the INSTRUMENT port. The SELECT pushbutton switch only functions when the OPERATION pushbutton switch is in the MANUAL mode. TA INSTRUMENTS GAS SWITCHING ACCESSORY 13

Gas Switching Accessory A typical mode of operation for the Gas Switching Accessory during actual experiments uses an inert gas such as nitrogen to be GAS 1, and a reactive gas such as oxygen to be GAS 2. Typical end-use applications include oxidative stability studies and TGA decomposition analyses. 14 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Installing the GSA Installing the GSA The Gas Switching Accessory can be used with various thermal analysis instruments, such as the DSC and TGA. This section describes unpacking, selecting a location, and installing the GSA. Unpacking the GSA Choosing a Location The accessory was inspected mechanically and electrically before shipment. After unpacking, inspect the accessory for mechanical damage. If it is damaged in transit, or fails to operate properly upon receipt, notify the carrier and TA Instruments immediately. Also check that you received all items on the shipping list. If any item is missing, notify TA Instruments immediately. Because of the sensitivity of many experiments, it is important to choose a location for the instrument using the following guidelines: In... a temperature-controlled area.... a clean environment.... an area with ample working space around the accessory. (Refer to the technical specifications on page 11 for the dimensions.) TA INSTRUMENTS GAS SWITCHING ACCESSORY 15

Gas Switching Accessory Near... a power outlet (120 Vac, 50 or 60 Hz, 10 amps). A step up/down line transformer may be required if the unit is operated from a higher or lower line voltage.... your TA Instruments thermal analysis controller and instrument.... purge gas supply for use during experiments. t CAUTION: Your air source must be clean, dry, and oil-free to ensure proper operation. Connecting the GSA To connect the Gas Switching Accessory to either the Module Interface, a 2900 series instrument, or a 2000 series instrument, follow the directions below. See Figure 3 on page 18 for an example of the installation of the GSA to a DSC instrument. See Figure 4 on page 19 for the installation of the GSA to a TGA instrument. 1. Plug the power cord (PN 890035.901 for CE instruments) into the connection on the GSA rear panel. Then plug the cord into your primary power source outlet. (Your power source should be 120 Vac only if your main voltage is higher or lower, a transformer will be required.) 2. Connect the appropriate cable between the GAS connector on the instrument and jacks J2 (+) and J3 (-) on the Gas Switching Accessory. (Use cable PN 990906.901 for 2900/2000 series instruments, 16 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Installing the GSA PN 890014.901 for CE instruments, or PN 992119.901 for MIM-based instruments.) NOTE:!WARNING The cable connectors may differ slightly in appearance, depending on the instrument involved. The GSA can be used with the following gases: nitrogen, oxygen, air, helium, or argon. If you want to use any other gases, contact the TA Instruments HelpLine for information. 3. Connect the lines from the purge gas sources to the appropriate inlet ports on the rear panel of the GSA. To facilitate the hookup of rubber tubing to the four threaded, brass gas fittings on the rear of the Gas Switching Accessory, install the four tapered, 1/4-inch brass tube hose connectors (PN 992302.001). t CAUTION: NOTE: Install the brass hose connectors until they are finger tight and then tighten them with a wrench until significant resistance is felt. Do not overtighten! Inert gases (such as nitrogen) are typically connected to the GAS 1 inlet, and reactive gases (such as oxygen) are connected to the GAS 2 inlet. 4. Connect the INSTRUMENT outlet line from the rear panel of the GSA to a flowmeter. Connect the outlet end of the flowmeter to the desired TA instrument. 5. Connect the VENT line on the rear panel of the GSA to a hood or some other appropriate exhaust system. TA INSTRUMENTS GAS SWITCHING ACCESSORY 17

Gas Switching Accessory Vent Flowmeter Gas Switching Accessory DSC Instrument Figure 3 Typical Gas Switching Accessory Installation to a DSC 2910 or 2920 Instrument 18 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Installing the GSA Balance Purge Furnace Purge Flowmeter Gas Switching Accessory TGA Instrument This configuration maintains an inert purge through the TGA balance chamber. Figure 4 Typical Gas Switching Accessory Installation to a TGA 2950 or 2050 Instrument TA INSTRUMENTS GAS SWITCHING ACCESSORY 19

Gas Switching Accessory Operating the GSA Before operating the GSA, it is important to become familiar with the various items located on the front and rear panels of the accessory. The GSA Front Panel Figure 5 provides an illustration showing the front panel and its controls. (See Figure 6 for the rear panel items.) Refer to Table 2 (on the next page) for a description of each item on the front panel. OPERATION Pushbutton Switch SELECT Pushbutton Switch Gas Indicator Lights Flow Regulation Knobs Figure 5 GSA Front Panel 20 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Operating the GSA Table 2 GSA Front Panel Controls Name SELECT pushbutton switch Description A two-position switch that allows you to select either GAS 1 or GAS 2. This switch functions only when the OPERA- TION pushbutton switch is in the MANUAL mode. (This switch can be used to test operation of the GSA for troubleshooting purposes.) A two-position pushbut- ton switch that enables you to manually control the selection of gases or place the accessory in AUTO mode. OPERATION pushbutton switch Gas Indicator Lights Two indicator lights that light selectively to indicate which purge gas is flowing to the instrument. Flow Regulation Used to regulate the flow Knobs of gases to the instrument and to the vent. TA INSTRUMENTS GAS SWITCHING ACCESSORY 21

Gas Switching Accessory NOTE: Flow regulation knobs are not to be used as onoff valves. The GSA Rear Panel Figure 6 provides an illustration showing the rear panel. (See Figure 5 for the front panel items.) Refer to Table 3 below for a description of the rear panel power switch. Connectors for Gas Lines Connectors for Cable 50 ma 250 V 35 ma POWER Switch Connection for Power Cable Figure 6 GSA Rear Panel Table 3 GSA Rear Panel Control Name POWER switch Description Controls power to the accessory. The O position is off. 22 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Operating the GSA Using the GSA Follow these steps to start and operate the Gas Switching Accessory. 1. Adjust the regulator valves on the pressurized gas supply tanks to 14 to 35 kpa (2 to 5 psi).!warning Do not exceed a supply tank pressure of 138 kpa (20 psi). 2. Press POWER switch on the Gas Switching Accessory rear panel to the ON position. 3. Press the SELECT pushbutton switch to the GAS 1 position (switch shows a high profile). 4. Press the OPERATION pushbutton switch to the MANUAL mode position (switch shows a low profile). The indicator light for GAS 1 should light.!warning Do not exceed an inlet pressure of 138 kpa gauge (20 psi). 5. Set the GAS 1 flow rate to the instrument by adjusting the GAS 1 knob on the GSA front panel for the desired flow rate (typically 50 to 75 ml/min) as indicated on a flowmeter (not supplied). A flowmeter needle valve may also be used in combination with the GAS 1 knob to obtain the required flow rate. 6. Press the SELECT pushbutton switch to the GAS 2 position. TA INSTRUMENTS GAS SWITCHING ACCESSORY 23

Gas Switching Accessory 7. Set the GAS 2 flow rate to the instrument by adjusting the GAS 2 knob on the GSA front panel for the desired flow rate (typically 50 to 75 ml/min) as indicated on a flowmeter (not supplied). A flowmeter needle valve may also be used in combination with the GAS 2 knob to obtain the required flow rate. NOTE: If you want to conserve gas, you can connect a restrictor or another flowmeter to the vent outlet and adjust the flow rate accordingly using the needle valve on the flowmeter. If the vent flow is restricted too much, a pressure spike may occur when the GSA switches from GAS 1 to GAS 2. The pressure spike may appear in your data. 8. Press the OPERATION pushbutton switch to the AUTO mode position. The GSA is ready for operation. 9. Use the controller software to set up and start the experiment. 24 TA INSTRUMENTS GAS SWITCHING ACCESSORY

Maintaining the GSA Maintaining the GSA Fuse Replacement The TA Instruments Gas Switching Accessory only requires an occasional cleaning for maintenance of proper operation. To clean the GSA, simply wipe any dirt or dust off the accessory using a cloth that has been damped with water and a mild detergent, if desired. If the fuse should need replacement, follow these instructions to remove and replace a blown fuse. 1. Important: Unplug the power cord before performing any further steps. 2. Slip the end of a small screwdriver under the fuse carrier tab and slide the carrier out of the GSA. 3. Remove the blown fuse from the fuse carrier. A spare fuse is located in a small compartment in the fuse carrier. You can remove the spare fuse by sliding out the compartment drawer using the end of the screwdriver. 4. Insert the new fuse in the plastic clip. 5. Obtain a new 35 ma, Type T, 250 V fuse and place it in the spare fuse compartment. Then replace the compartment and slide the fuse carrier back into the GSA. TA INSTRUMENTS GAS SWITCHING ACCESSORY 25

Gas Switching Accessory 26 TA INSTRUMENTS GAS SWITCHING ACCESSORY