Pressurize Well to One Atmosphere with Probe Installed

Similar documents
GUARD TANK PRESSURIZATION FOR TRANSPORT

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR DISCONNECT MAIN TANK VENT LINE FROM GAS MODULE MAIN TANK SUBATMOSPHERIC

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR REGULATE GUARD TANK PRESSURE

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR

PUMP DOWN MAIN TANK TO SUBATMOSPHERIC CONDITION

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Install Fill Line Relief Assembly on SMD

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Install Fill Line Burst Disk on SMD

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR STOP PUMPING ON SMD VACUUM SHELL / DISCONNECT VACUUM MODULE

Reduce Liquid Level in Main Tank- Liquid at NBP To be performed at Vandenberg Air Force Base building 1610

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Upright SMD (Rotate from Horizontal to Vertical Orientation)

(PTP) Un-vented Rate of Temperature Rise Using Guard Tank

PREPARE FOR CRYO OPS FOLLOWING TRANSPORT TO B1610 To be performed at Vandenberg Air Force Base building 1610

(PTP) Un-vented Rate of Rise of Main Tank w/ Gas in Well

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Prepare Payload for Mass/CG Measurements and Condition Payload During Spin Balance Test

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Spacecraft Battery Magnetic Field Survey

GUARD TANK LIQUID LEVEL REDUCTION To be performed at Vandenberg Air Force Base building 1610

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR MAIN TANK SUBATMOSPHERIC FILL FROM NBP SUPPLY DEWAR GUARD TANK PRECOOL

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR CONNECT VACUUM MODULE / PUMP ON SMD VACUUM SHELL

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Configure SMD for Transport to SLC-2W To be performed at Vandenberg Air Force Base building 1610

CERTIFICATION OF THE TEMPERATURE MONITOR AND ALARM

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR MAIN TANK SUBATMOSPHERIC FILL FROM NBP SUPPLY DEWAR GUARD TANK PRECOOL.

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR

GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR. Prep Payload for Thermal Vacuum Test

POROUS PLUG CHARACTERIZATION TEST

(PTP) PROBE PRESSURE MEASUREMENT SYSTEM INSTALLATION AND LEAK CHECK PROCEDURE

BLEED DOWN OF THE HIGH GMA PRESSURE

GMA SLEEP PROCEDURE AT VAFB

GSE CAGING AND SPINUP BUFFER LINE INSTALLATION

STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA

GDS OPERATING PROCEDURE

INTERNAL LEAKAGE CHECK OF THE FLIGHT GMA

GSE CAGING BALLAST SYSTEM INSTALLATION

(PTP) REMOVE PROBE SPINUP GAS/VAC. LINES (HORIZ.)

GMA FUNCTIONAL TEST SETTING & TESTING OF SPIN UP PARAMETERS. P0586 REV -- 20, June 2000 GPB SCIENCE MISSION PROCEDURE

TEST OF GMA SPINUP ASSEMBLY PRESSURE SENSOR CALIBRATION

Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and 3223) spare units. GP-B Engineering Procedure P0761 Rev.-

SCRUB LAUNCH RECOVERY PROCEDURE FOR THE GMA

GMA VENT EXTENSION SERVICE PROCEDURE

Proton Monitor Thermal Vacuum Test Procedure GP-B P0635

DESIGN VERIFICATION AND QUALIFICATION OF NEW POPPET AND BUSHING ON GMA FLIGHT SOLENOID VALVES

LOW PRESSURE VOLTAGE BREAKDOWN TEST PROCEDURE FOR GSS FSU FLIGHT SPARE HVA BOARD October 28, P0938 Rev

CHECK READOUT LOOP CONTINUITY IN PROBE C

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

CALIBRATING THE GMA PRESSURE SENSORS AND THE ECU ENGINEERING UNIT

STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA

BLEED DOWN OF THE GMA HIGH PRESSURE AT VAFB

PROCEDURE FOR THERMAL CYCLING IN LIQUID NITROGEN

GMA PREPARATION FOR E28 TESTING

PROCEDURE TO MEASURE READOUT LOOP RESISTANCE

PROBE-C CAGING VALVE INSTALLATION

CLEANLINESS TEST OF PROBE SPINUP EXHAUST LINES

GMA TO SPACE VEHICLE PLUMBING HOOKUP

Inert Air (N2) Systems Manual

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

ASSEMBLY OF GAS FLOW HARDWARE INTO SM GMA

STANDARD OPERATING PROCEDURES

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

MEDICAL EQUIPMENT CATALOG

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Teacher s Assistant Laboratory Guide

STANDARD OPERATING PROCEDURES

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Installing a Probe. Typical Installation

Dilution Refrigerator manual

NPDGamma LH2 Target OJT Lesson Plan: Senior Operator for the NPDGamma LH2 Target Operators

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Gas Absorption Draft Standard Operating Procedure

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

HYDROSTATIC LEAK TEST PROCEDURE

CRYO INDUSTRIES. Liquid Helium Research Dewars

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Major Design Features

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Pneumatic high-pressure controller Model CPC7000

Rejuvenation Instructions

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Healthcare. Ref: Final results of the quench line inspection at your MAGNETOM system. Dear Siemens MR User,

Cryostream 800 Series

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Cryogenic Materials Operating Procedure and Safety Requirements

Additel 780 Series Pressure Controller

Specification Sheet. Equipment Model: J-VAC-12 High Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

200 PSI FAST-FILL AIR SOURCE KIT

Proto-qual Vibration Test Procedure 2.5 and 6 Vacuum Valves (3179 and 3223) Retest of Flight Spare Valves. GP-B P0735 Rev.-

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

FPG8601 Force Balanced Piston Gauge

ACV-10 Automatic Control Valve

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Transcription:

Stanford University GRAVITY PROBE B PROCEDURE FOR SCIENCE MISSION DEWAR Pressurize Well to One Atmosphere with Probe Installed ECO 1089 September 25, 2000 Revised by Date Jim Maddocks Cryogenic Test Checked by Date Dave Murray Cryogenic Test Approvals: Date Dorrene Ross Quality Assurance Date Barry Muhlfelder Payload Technical Manager Date Harvey Moskowitz LMMS Safety Date Mike Taber Payload Test Director

REVISION RECORD REVISION ECO PAGES DATE A 1089 Changed title to Pressurize Well to One Atmosphere with Probe Installed. Changed Sections A, B, C, D, E, and F to comply with other cryogenic procedures, as well as, accurately reflect changes in scope and changes in personnel. Incorporated list of configuration requirements Changed Section G (Operations). Added sections to verify QA notification and initial configuration. Deleted sections on leak back testing of VTH, replaced with leak test of newly installed vent line. page ii

Table of Contents A. SCOPE...1 B. SAFETY...1 B.1. Potential Hazards...1 B.2. Mitigation of Hazards...1 B.3. Injuries...2 C. QUALITY ASSURANCE...2 C.1. QA Notification...2 C.2. Red-line Authority...2 C.3. Discrepancies...2 D. TEST PERSONNEL...3 D.1. Personnel Responsibilities...3 D.2. Personnel Qualifications...3 D.3. Qualified Personnel...3 E. REQUIREMENTS...3 E.1. Electrostatic Discharge Requirements...3 E.2. Lifting Operation Requirements...3 E.3. Hardware/Software Requirements...3 E.4. Instrument Pretest Requirements...4 E.5. Configuration Requirements...5 E.6. Optional Non-flight Configurations...6 F. REFERENCE DOCUMENTS...8 F.1. Drawings...8 F.2. Supporting documentation...8 F.3. Additional Procedures...8 G. OPERATIONS...9 G.1. Verify Appropriate QA Notification...9 G.2. Verify Configuration Requirements and Record Initial Conditions...9 G.3. Verify Gas-Module in Standard Configuration...10 G.4. Verify SMD in Standard Configuration...11 G.5. Connect Well Vent to Gas Module, Pump and Backfill Vent Line...11 G.6. Perform Leak Test on Well Vent Line:...11 G.7. Verify Well Evacuated...12 G.8. Open Well to Gas Module...12 G.9. Bring Well Up to One Atmosphere by Opening RAV-7:...12 G.10. Close RAV-7...13 G.11. Fill Well...13 G.12. (Option) Add Flex Line Section Between VTH and Well Manifold:...13 page iii

List of Abbreviations and Acronyms AG-x Gauge x of Gas Module auxiliary MT Main Tank section AMI American Magnetics Inc. MTVC Main Tank Vent Cap ATC Advanced Technology Center MTVC-G Main Tank Vent Cap pressure gauge Aux Auxiliary MTVC-RV Main Tank Vent Cap relief valve AV-x Valve x of Gas Module auxiliary MTVC-V Main Tank Vent Cap valve section Bot Bottom NBP Normal boiling point CN [xx] Data acquisition channel number ONR Office of Naval Research DAS Data Acquisition System PFCG Fill Cap assembly pressure Gauge EFM Exhaust gas Flow Meter PFM Pump equipment Flow Meter EG-x Gauge x of Gas Module exhaust PG-x Gauge x of Pump equipment section EM Electrical Module PM Pump Module ERV-x Relief valve of Gas Module exhaust psi pounds per square inch section EV-x Valve number x of Gas Module exhaust section psig pounds per square inch gauge FCV Fill Cap Valve PTD Payload Test Director FIST Full Integrated System Test PV-x Valve x of the Pump equipment GHe Gaseous Helium QA Quality Assurance GM Gas Module RAV-x Remote Actuated Valve-x GP-B Gravity Probe-B RGA Residual Gas Analyzer GSE Ground Support Equipment SMD Science Mission Dewar GT Guard Tank STV SMD Thruster vent Valve GTVC Guard Tank Vent Cap SU Stanford University GTVC-G Guard Tank Vent Cap pressure gauge SV-x SMD Valve number x GTVC-RV Guard Tank Vent Cap relief valve TG-x Gauge x of Utility Turbo System GTVC-V Guard Tank Vent Cap valve TV-x Valve x of Utility Turbo System GTV-G Guard Tank vent pressure gauge UTS Utility Turbo System GTV-RV Guard Tank vent relief valve Vac Vacuum GTV-V Guard Tank vent valve VCP-x Vent cap pressure gauge HX-x Vent line heat exchanger in Gas VCRV-x Vent cap relief valve Module KFxx Quick connect o-ring vacuum flange VCV-x Vent cap valve (xx mm diameter) LHe Liquid Helium VDC Volts Direct Current LHSD Liquid Helium Supply Dewar VF-x Liquid helium Fill line valve Liq Liquid VG-x Gauge x of Vacuum Module LL Liquid level VM Vacuum Module LLS Liquid level sensor VV-x Valve x of Vacuum Module LMMS Lockheed Martin Missiles and Space VW-x Valve x of Dewar Adapter LMSC Lockheed Missiles and Space Co. page iv

A. SCOPE This procedure describes the steps necessary to raise the pressure in the Well to one atmosphere while the Probe is installed. These steps include: Pump and backfill vent line Open Well to vent line Open RAV-7 The procedure requires that the Well be immediately filled with liquid per procedure P0210. B. SAFETY B.1. Potential Hazards Personal injury and hardware damage can result during normal positioning, assembly and disassembly of hardware. Examples include: positioning Dewar in tilt stand; integrating probe with airlock; positioning airlock on Dewar; removing airlock from Dewar; removing probe from Dewar; and positioning support equipment such as pressurized gas cylinders and supply dewars. A number of undesired events may be associated with these operations. For example, personnel or equipment can be struck when hardware is being moved (e.g. by forklift or crane load). Personnel are subject to entrapment while positioning hardware, such as hands or feet caught between objects as hardware is moved into place. Suspended hardware may be dropped. Personnel can be caught between objects such as forklifts and walls or loads and building support columns. In addition, liquid helium used in the SMD represents a hazardous material for the personnel involved in the operations. Cryogenic burns can be caused by contact with the cold liquid or gas, high pressures can result if boiling liquid or cold gas is confined without a vent path, and asphyxiation can result if the vent gas is allowed to accumulate. The SMD Safety Compliance Assessment, document GPB-100153C discusses the safety design, operating requirements and the hazard analysis of the SMD. B.2. Mitigation of Hazards B.2.1. Lifting hazards There are no lifting operations in this procedure B.2.2. Cryogenic Hazards The FIST OPS laboratory has an oxygen deficiency monitor that alarms when the oxygen level is reduced to 19.5%. Additional temperature and pressure alarms, provided by the DAS, warn of potential over-pressure conditions. Emergency vent line deflectors are installed over the four burst disks on the SMD vacuum shell, and oxygen collection pans are on the floor beneath them. Page 1

The following requirements apply to personnel involved in cryogenic operations. Gloves that are impervious to liquid helium and liquid nitrogen are to be worn whenever the possibility of splashing or impingement of high-velocity cryogens exists or when handling equipment that has been cooled to cryogenic temperatures. Protective clothing and full-face shields are to be worn whenever the possibility of splashing cryogens exists. The FIST Emergency Procedures document, SU/GP-B P0141, discusses emergency procedures. These documents should be reviewed for applicability at any facility where the hardware is operated. B.3. Injuries In case of any injury obtain medical treatment as follows LMMS Call 117; Stanford University Call 9-911 C. QUALITY ASSURANCE C.1. C.2. C.3. QA Notification The ONR representative and SU QA shall be notified 24 hours prior to the start of this procedure. Upon completion of this procedure, the QE Manager will certify her concurrence that the effort was performed and accomplished in accordance with the prescribed instructions by signing and dating in the designated place(s) in this document. Red-line Authority Authority to red-line (make minor changes during execution) this procedure is given solely to the PTD or his designate and shall be approved by the QA Representative. Additionally, approval by the Hardware Manager shall be required, if in the judgement of the PTD or QA Representative, experiment functionality may be affected. Discrepancies A Quality Assurance Representative designated by D. Ross shall review any discrepancy noted during this procedure, and approve its disposition. Discrepancies will be recorded in a D-log or a DR per Quality Plan P0108. Any time a procedure calls for verification of a specific configuration and that configuration is not the current configuration, it represents a discrepancy of one of three types. These types are to be dealt with as described below. 1. If the discrepancy has minimal effect on procedure functionality (such as the state of a valve that is irrelevant to performance of the procedure) it shall be documented in the procedure, together with the resolution. Redlines to procedures are included in this category. 2. If the discrepancy is minor and affects procedure functionality but not flight hardware fit or function, it shall be recorded in the D-log. Resolution shall be in consultation with the PTD and approved by the QA representative. Page 2

3. All critical and major discrepancies, those that effect flight hardware fit or functions, shall be documented in a D-log and also in a Discrepancy Report, per P0108. D. TEST PERSONNEL D.1. Personnel Responsibilities The performance of this procedure requires a minimum complement of personnel as determined by the Test Director. The Test Director is the designated signer for the witnessed by sign-off located at the end of each procedure. The person in charge of the operation (Test Director or Test Engineer) is to sign the completed by sign-off. D.2. Personnel Qualifications The Test Director must have a detailed understanding of all procedures and facility operations and experience in all of the SMD operations. Test Engineers must have SMD Cryogenic operations experience and an understanding of the operations and procedures used for the cryogenic servicing/maintenance of the Dewar. D.3. Qualified Personnel Test Director Mike Taber Dave Murray Jim Maddocks Dave Frank Test Engineer Tom Welsh Chris Gray Bruce Clarke E. REQUIREMENTS E.1. Electrostatic Discharge Requirements This procedure does not include any equipment sensitive to electrostatic discharge. E.2. Lifting Operation Requirements There are no lifting operations in this procedure E.3. Hardware/Software Requirements E.3.1. Commercial Test Equipment No commercial test equipment is required for this operation. E.3.2. Ground Support Equipment The Ground Support Equipment includes the Gas Module, the Pump Module, the Electrical Module, and the Vacuum Module. The Gas Module provides the capability to configure vent paths, read pressures and flow rates, and pump and backfill vent lines. The Pump Module provides greater pumping capacity than the Gas Module, together with additional flow metering capabilities. The vent output of the Gas Module Page 3

flows through the Pump Module. The Electrical Module contains the instruments listed in Table 1, and provides remote control of valves in the Gas Module, Pump Module, and SMD. The Vacuum Module contains a turbo pump, backed by a vane pump, and provides the capability to pump out the SMD vacuum shell. This procedure calls for use of hardware located in the Gas Module (Figure 1), and Electrical Module (Table 1). E.3.3. Computers and Software: The Data Acquisition System (DAS) and data acquisition software are required for this procedure. The DAS reads and displays pressures, temperatures, and flow rates and monitors critical parameters. No additional computers or software are required. E.3.4. Additional Test Equipment No additional test equipment is required E.3.5. Additional Hardware E.3.6. Tools Description 1-inch diameter Well vent line 3-ft. Stainless steel flex line (optional) No special tools are required E.3.7. Expendables No expendables are required E.4. Instrument Pretest Requirements The GSE instruments required to perform this procedure are listed in Table 1, together with their serial numbers, where available. Instruments that are required to have current calibrations are indicated in the Cal-Required column. Instruments that do not require calibration are those not used to verify performance requirements and are not connected to flight instrumentation. The status column is to be filled in with the due date of the instrument calibration sticker and verified to be in calibration by QE or QE designee. Serial numbers are to be updated as appropriate. Table 1. Required Instrumentation and Calibration Status No. Location Description User Name Serial No. Cal Required Status Cal due date 1 DAS Power Supply, H-P 6627A - 3452A01975 Yes 2 DAS Power Supply, H-P 6627A - 3452A01956 Yes 3 DAS Data Acquisition/Control Unit H-P 3497A 4 DAS Digital Multimeter H-P 3458A - 2936A245539 No - - 2823A15047 Yes Page 4

No. Location Description User Name Serial No. Cal Required Status Cal due date 5 EM Vacuum Gauge Controller Granville-Phillips Model 316 6 EM Vacuum Gauge Controller Granville-Phillips Model 316 7 EM Vacuum Gauge Controller Granville-Phillips Model 316 EG-1a, -1b 2827 No - AG-2a, -2b 2826 No - EG-3 2828 No - 8 EM MKS PDR-C-2C EG-2, FCG 92022108A No - 9 EM Flow meter Matheson 8170 EFM-1 96186 No - 10 EM Flow meter totalizer Matheson 8124 11 EM Liquid Helium Level Controller American Magnetics, Inc. 136 12 EM Liquid Helium Level Controller American Magnetics, Inc. 136 13 EM Liquid Helium Level Controller American Magnetics, Inc. 136 14 EM Liquid Helium Level Controller American Magnetics, Inc. 136 EFM-1 96174 No - LLS Main Tank LLS Guard Tank 96-409-11 No - 96-409-10 No - LLS Well 96-409-9 No - LLS Axial Lock 96-409-12 No - 15 EM Pressure Controller MKS 152F-92 EV-7a, -7b 96203410A No - 16 EM Power Supply HP 6038A 17 EM Power Supply HP 6038A 18 EM Power Supply HP 6038A 19 EM Vac Ion Pump power supply Varian 929-0910, Minivac 20 EM Flow meter totalizer Veeder-Root H08D Tank Heater H09D Tank Heater RAV Power Supply 96023407A Yes 3511A-13332 Yes 3329A-12486 Yes SIP 5004N No - PFM-1 576013-716 No - 21 GM Pressure Gauge, Heise AG-1 CC-122077 No - 22 GM Pressure Gauge, Marshall Town AG-3 N/A No - 23 GM Main Tank Heat Exchanger: a) Thermocouple, b) Current meter, c) Temperature set point controller 24 GM Guard Tank Heat Exchanger: a) Thermocouple, b) Current meter, c) Temperature set point controller 25 VM Vacuum Gauge readout, Granville-Phillips 316 26 VM Vacuum Gauge readout, Granville-Phillips 360 E.5. Configuration Requirements E.5.1. Main Tank - C-19950 No - - C-09920 No - VG-3 VG-4 VG-1, VG-2 VG-5 2878 No - 96021521 No - Liquid in the Main Tank must be at its normal boiling point (NBP). E.5.2. Guard Tank Page 5

E.5.3. Well The Guard Tank may contain liquid or be depleted and pressure regulated. The Well is evacuated, and the Probe is installed. E.5.4. SMD Vacuum Shell The Vacuum Shell pressure is not read in this procedure. 1. The DAS alarm system must be enabled and contain the following alarm set-points: a. Station 200 temperature (CN 01) set at T 6.5 K. b. Top of lead bag temperature set (CN 28) at T 6.0 K. c. Relative Guard Tank Pressure (CN 46) set at P 0.3 torr. 2. The Facility Main Alarm System must be armed. E.5.5. GSE and Non-flight Hardware 1. GSE cabling must be connected between the SMD and the Electrical Module (P/N 5833812) and between the SMD and the Data Acquisition System (P/N 5833811). 2. The Well vent manifold pictured in Figure 2 must be installed at the Well vent. 3. The Guard Tank Vent Valve Assembly is installed in the GT vent line. E.6. Optional Non-flight Configurations The following modifications or non-flight arrangement of the basic SMD configuration may also be in place. They are incidental to the performance of this procedure and not required. 1. The SMD is installed in its transportation/test fixture. 2. A relief valve is installed in place of the fill line burst disk. 3. A foreign object and debris shield covering the upper cone of the SMD is installed. 4. The ion pump magnet is installed. 5. The Main Tank vent may be connected to the Gas Module with a vacuum insulated line (P/N 5833806) or may be disconnected and venting through the appropriate vent line cap. 6. The Guard Tank vent may be connected to the Gas Module (P/N 5833813) with a vacuum insulated line or may be disconnected from the Gas Module and depleted of liquid, with its pressure independently regulated. 7. The Vacuum shell pump out port at SV-14 may be connected to the Vacuum Module (P/N 5833816) via a 2-in valve operator and pumping line, with the valve in either the closed position or in the open position. The Vacuum Module pump may be; off, actively pumping the pumping line up to a closed SV-14, or actively pumping the vacuum shell. Page 6

8. The thruster vent port must be flanged to a shut-off valve. 9. The Fill Cap Assembly may be installed at SV-13. Page 7

F. REFERENCE DOCUMENTS F.1. F.2. F.3. Drawings Drawing No. Title LMMS-5833394 Instrumentation Installation Supporting documentation Document No. Title LMMC-5835031 GP-B Magnetic Control Plan GPB-100153C SMD Safety Compliance Assessment SU/GP-B P0141 FIST Emergency Procedures LMSC-P088357 Science Mission Dewar Critical Design Review P0108 Quality Plan Additional Procedures Document No. SU/GP-P0210 Title Internal Main Tank to Well Transfer Page 8

Operation Number: Date Initiated: Time Initiated: G. OPERATIONS G.1. G.2. Verify Appropriate QA Notification Verify SU QA notified. Record: Individual notified, Date/time /. Verify ONR representative notified. Record: Individual notified, Date/time /. Verify Configuration Requirements and Record Initial Conditions G.2.1. Verify enabled/enable Facility Main Alarm System. G.2.2. Verify Probe installed. G.2.3. Verify liquid in Main Tank at NBP (4.2<T<4.3) and record temperature at bottom of tank CN [9] K. G.2.4. Verify GSE cabling connected between SMD and Electrical Module and between SMD and Data Acquisition System. G.2.5. Verify DAS alarm system enabled and record set points. 1. Station 200 temperature verify [CN 1] on DAS alarm list and set to alarm at T 6.5 K. Record set point. 2. Top of lead bag temperature verify [CN 28] on DAS alarm list and set to alarm at T 6.0 K. Record set point. 3. Relative Guard Tank Pressure verify [CN46] on DAS alarm list and set to alarm at P 0.3 torr. Record set point. K K tor r G.2.6. Verify enabled and record the liquid-level alarm set points. 1. Main Tank ensure liquid-level alarm set 20%. Record set point. 2. Guard Tank ensure liquid-level alarm set 10% (if liquid in GT). Record set point. % % Page 9

G.2.7. Verify VTH closed. G.2.8. Verify Well vent manifold installed per Figure 2. Manifold installed with optional flex-line. Manifold installed without optional flex-line. G.3. Verify Gas-Module in Standard Configuration G.3.1. Establish Intital configuration. Initial Valve States Configuration Open Closed Main Tank at NBP Connected to GM Disconnected from GM Guard Tank connected to GM Venting in bypass mode: Venting in common manifold mode Depleted and pressure regulated: verify He gas connected through APR-2 to EV-23. Guard Tank disconnected from GM Venting in bypass mode: Venting in common manifold mode: Depleted and pressure regulated: verify He gas connected through APR-2 to GTV-Va. EV-9 MTVC-Va EV-20, EV-16, GTV-V EV-16, EV-13, GTV-V EV-16, EV-23, GTV-V GTV-V GTVC-V, MTVC-V GTV-V GTV-Va EV-17 EV-9, EV-17 EV-13, EV-23 EV-20, EV-23 EV-13, EV-20 EV-13, EV-16, EV-20, EV-23, GTV-Va, GTVC-V, MTVC-V EV-13. EV-16, EV-20, EV-23, GTV-Va EV-13. EV-16, EV-20, EV-23, GTVC-V, MTVC-V, GTV-V Well Evacuated with Probe installed: VTH, VW-3, EV-19, EV-11, EV-15 Other EV valves EV-7a/b EV-4, EV-5, EV-6, EV-8, EV-10, EV-12, EV-14 EV-18, EV-21/22, EV-24 AV valves All Page 10

G.3.2. Record pressures. 1. Well Vent Manifold (PW-3) mtorr. 2. If Main Tank connected to GM (EG-3): torr. 3. If Main Tank disconnected from GM (MTVC-G) torr (relative to atm) 4. If Guard Tank Connected to GM (EG-1a): torr. G.4. 5. If Guard Tank disconnected from GM (GTV-G) torr (relative to atm.). Verify SMD in Standard Configuration G.4.1. Using the RAV log book verify that the dewar s internal valves are in the following positions. If not, investigate to verify previous RAV operations properly recorded. If necessary, note resolution in D-log. 1. Open: RAV-3, and RAV-6B. 2. Closed: RAV-1, RAV-2, RAV-5, RAV-6A, and RAV-7. G.5. Connect Well Vent to Gas Module, Pump and Backfill Vent Line G.5.1. Attach 1-inch diameter Well vent line from EV-19 on Gas Module to KF fitting at VW-3 on Well vent manifold, per Figure 2. G.5.2. Pump out and backfill Well vent line as follows: 1. Turn on pump AP-1. 2. Close/verify closed EV-16. 3. Open AV-6 and EV15: now pumping up to closed VW-3. 4. When EG-1b < 50 mtorr close AV-6. 5. Open EV-10 and EV-12. 6. Open AV-9 and adjust vent line pressure to one atmosphere, as indicated by EG-1a, then close AV-9. 7. Close EV-10 and EV-12 G.6. 8. Open AV-6, now pumping up to VW-3. Perform Leak Test on Well Vent Line: G.6.1. When EG-1b < 20 mtorr close AV-6 and record time of day. G.6.2. Record pressure EG-1b every 5 minutes for 25 minutes Time 0 5 10 15 20 25 EG-1b (mtorr) Pressure Rise (mtorr) G.6.3. Verify pressure EG-1b doesn t rise by more than 5 mtorr during the last 10 minutes. Pass Fail. Page 11

G.6.4. If leak test fails, check vent line connections at EV-19 and VW-3 and repeat leak test Time 0 5 10 15 20 25 EG-1b (mtorr) Pressure Rise (mtorr) G.7. G.6.5. Verify pressure EG-1b doesn t rise by more than 5 mtorr during the last 10 minutes. Pass Fail. Verify Well Evacuated G.7.1. Open AV-6 G.7.2. Open VW-3, now pumping up to VTH G.7.3. When PW-3 < 20 mtorr, close VW-3. G.7.4. Open VTH to verify Well evacuated. G.7.5. Record Well pressure PW-3 torr. G.8. Open Well to Gas Module G.8.1. Close AV-6 G.8.2. Open VW-3, Well now open to gas module G.9. Bring Well Up to One Atmosphere by Opening RAV-7: G.9.1. Verify all RAV selection switches in the OFF position. G.9.2. Turn on RAV power supply adjust current limit to 1.8 amps. G.9.3. Adjust power supply to 28 VDC. G.9.4. Power up controller #4. G.9.5. Position controller #4 selection switch to RAV-7. G.9.6. Record initial switch status: Open: θ θ Closed: θ θ G.9.7. Activate controller #4 to open RAV-7 and record: 1. Run time: seconds 2. Current draw: amp 3. Time of day: G.9.8. Record final switch status: Open: θ θ Closed: θ θ G.9.9. When convenient, record operation in RAV Log Book. Page 12

G.10. Close RAV-7 Note: As soon as the Well pressure reaches 1 atm., as indicated by EG-1a, Close Rav-7. G.10.1. Record initial switch status: Open: θ θ Closed: θ θ G.10.2. Activate controller #4 to close RAV-7 and record: 1. Run time: seconds 2. Current draw: amp 3. Time of day: G.10.3. Record final switch status: Open: θ θ Closed: θ θ G.10.4. Turn controller selection switch #4 to OFF position. G.10.5. Power off controller #4. G.10.6. Turn off RAV power supply. G.10.7. When convenient, record operation in RAV Log Book. G.10.8. Enter comment in DAS Pressurized Well to 1 atmosphere. G.11. Fill Well G.11.1. Turn on power to Well liquid level sensors. G.11.2. Open EV-19: Well venting in bypass mode. G.11.3. Fill Well to cover Well liquid level sensors and continue 15 minutes past that point using Procedure P0210. Record Operation No. Note: filling the Well may be difficult in that it is likely to be warm, resulting in a rapid boiloff rate. Two or three repetitions of P0210, over a period of 48 hours, may be necessary before the Well level remains at Station 200 (i.e., maintains a non-zero reading on the Well level sensor). G.12. (Option) Add Flex Line Section Between VTH and Well Manifold: Comment: This may be required to allow clearance for various test or fit-check activities (See Figure 2.). G.12.1. Verify strong flow of helium from Well vent. G.12.2. Prepare 3-ft length flex line with one end capped off with a 0.5 psid relief valve. G.12.3. Close VW-3 and remove the Well vent manifold at VTH and immediately install the flex line. G.12.4. If necessary replace PW-3 with compound gauge. G.12.5. Arrange Well manifold so as not to interfere with activity. G.12.6. Remove relief valve from flex line and attach to Well vent manifold. Page 13

Verify Final Configuration G.12.7. Verify valve states are as indicated in following Table. Record configuration in left-hand column, then verify corresponding valve states. Initial Valve States Configuration Open Closed Main Tank at NBP Connected to GM Disconnected from GM Guard Tank connected to GM Venting in bypass mode: Venting in common manifold mode Depleted and pressure regulated: verify He gas connected through APR-2 to EV-23. EV-9 MTVC-Va EV-20, EV-16, GTV-V EV-16, EV-13, GTV-V EV-16, EV-23, GTV-V EV-17 EV-9, EV-17 EV-13, EV-23 EV-20, EV-23 EV-13, EV-20 Guard Tank disconnected from GM Venting in bypass mode: Venting in common manifold mode: Depleted and pressure regulated: verify He gas connected through APR-2 to GTV-Va. GTV-V GTVC-V, MTVC-V GTV-V GTV-Va EV-13, EV-16, EV-20, EV-23, GTV-Va, GTVC-V, MTVC-V EV-13. EV-16, EV-20, EV-23, GTV-Va EV-13. EV-16, EV-20, EV-23, GTVC-V, MTVC-V, GTV-V Well Filled with Probe installed: VTH, VW-3 EV-19 EV-11, EV-15 Other EV valves EV-7a/b EV-4, EV-5, EV-6, EV-8, EV-10, EV-12, EV-14 EV-18, EV-21/22, EV-24 AV valves All Page 14

G.12.8. Verify DAS alarm enabled and record set points if changed Thermal conditions substantially unchanged, alarm set points for Station 200 and lead bag are unchanged and set to alarm. Thermal conditions substantially changed, temperature alarm points reset as follows: a. Station 200 set point [CN 1] K ( 6.5 K) b. Top of Lead Bag set point [CN 28] K ( 6.0 K) G.12.9. Ensure liquid level sensor alarms enabled and record set points if changed. 1. Main Tank Level ensure liquid-level alarm set 20%. Record set point. 2. Well Level ensure liquid-level alarm set 20% if able to maintain liquid. Record set point. % % G.12.10. 3. Guard Tank Level ensure liquid-level alarm set 10% (if liquid in GT). Record set point. % Verify Main Facility Alarm enabled. Completed by: Witnessed by: Date: Time: Quality Manager Payload Test Director Date Date Page 15

ERV-6 (1/3 psi) ERV-5 (1/3 psi) EV-20 EV-19 EV-24 EV-23 APR-2 He gas supply Vent Output ERV-1 (1/3 psi) EV-6 EV-18 EFM-1 EV-15 EV-11 ERV-2a (2.0 psi) Well Vent EV-22 EV-21 EV-7B M M EG-1a 1000 torr bara. EG-1b conv. EV-16 EV-17 EV-9 EV-13 ERV-4a 2.0 psi ERV-3a (2.0 psi) ERV-2b (4 psi) ERV-3b (4.0 psi) EH-2 Guard Tank Vent Pump Out EV-14 EV-4 EV-7A EV-10 EG-3 1000 torr Cap. ERV-4b (4.0 psi) EH-1 (Heat Exchanger) Main Tank Vent EV-5 Access #3 EV-8 EG-2 100 torr Cap. EV-12 AV-5 AV-6 AV-8 AV-3 ARV-1 (1.0 psi) AF-1 Exhaust AP-1 Vane Pump AG-1 30 in to 30 psi AG-2a Bara 1000 torr AG-2b conv. AV-10 AV-1 AG-3 AV-9 APR-1 Access #1 He Gas Supply AV-2 ARV-2 1.0 psi AV-7 Access #2 AV-4 AH-1 Heat Exchanger Figure 1. Schematic of Gas Module Plumbing. LHe Supply Dewar Page 16

Well VTH RVW-2 VW-3 PW-3 Optional Flex Line EV-19 EV-11 Gas Module Figure 2. Schematic of Well vent manifold and its connection to the Gas Module. Page 17

MT Vent Line to GM. SV-9 GT Vent Line to GTVVA and GM. Well Vent through Dewar Adapter or Well Vent Manifold to GM. STRV 1.0 psi STV Neck Tube SV-14 operator SV-14 STG Thruster Vent Manifold Guard Tank Axial Lok LLS LLS H-3D H-4D PO Pumping Line to Vac Module 2 3 Porous Plug LLS Well LLS 5 6B 6A FEP 7 1 SV-13 FCRV 4.0 psi FCV Main Tank Well Bayonet B3 PFCG H-8D H-9D Fill Cap Assy. Vacuum Shell Valve Positions Open Closed 1 RAV-1 3 RAV-3 2 RAV-2 5 RAV-5 Remote Actuated Valves (RAV) 6A 6B RAV-6A RAV-6B 7 RAV-7 Figure 3. Schematic of Science Mission Dewar plumbing. Page 18

MAIN TANK VENT CAP ASSY SV-9 Main Tank Short Vent Line MTSL-RV 4.0+0.3 psid MTVC-G MTVC-V MTVC-RVc,d 1.0 & 0.3 psid MTVC-RVa,b 0.3 psid MTVC-Va To Room GT/MT Manifold line SMD GTV-Va GTV-V GTVG GTVC-G GTVC-V GTVC-RVa,b 0.3 psid GTVC-Fill Vent To Room Guard Tank ShortVent Line GTSL-RV 4.0+0.3 psid GTV-RV 4.0+0.3psid GTVVA GUARD TANK VENT CAP ASSY Vacuum clad Vent line Bayonet fitting Endevco 2psid (2PLS) Figure 4. Schematic representation of Guard Tank Vent Valve Assembly (GTVVA) and Main Tank and Guard Tank vent cap assemblies. Common manifold capability is provided by the GT/MT manifold line. Page 19