PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Similar documents
CUT OFF TOOL MODEL: CAT113

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

PRESSURISED PAINT CONTAINER

4 ANGLE GRINDER MODEL NO: CAT 52 PART

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

HYDRAULIC PALLET TRUCKS. MODEL Nos: PT550BC, PT685BC, PT550NC, PT685NC OPERATION & MAINTENANCE INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

AIR STAPLER MODEL: CSG1C Part No

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

30T A/Manual Hydraulic Shop Press

HIGH SPEED SABRE SAW

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

VERTICAL AIR COMPRESSORS

HYDRAULIC MOBILE LIFTING TABLE

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

VERTICAL AIR COMPRESSORS

200L BELT DRIVEN AIR COMPRESSOR

OPERATION & MAINTENANCE INSTRUCTIONS

1/2 REVERSIBLE RATCHET. 1/2 REVERSIBLE RATCHET MODEL NO: CAT 22b + CAT 91 PART No: & OPERATION & MAINTENANCE INSTRUCTIONS

50L BELT DRIVEN AIR COMPRESSOR

DUAL ACTION SANDER MODEL NO: CAT121 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0211

75 Ton SD Shop Press Operating Instructions

air/hydraulic nut riveter heavy-duty vacuum system

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

REVERSIBLE AIR DRILL

IMPACT WRENCH MODEL NO: CAT78 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0813

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

20 Ton SD Shop Press Operating Instructions

HEAVY DUTY BELT SANDER. MODEL NO: CAT 70 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 0906

Product Sheet Spraymist Unit

3/8 ANGLED AIR DRILL

PIONEER 205 OPERATING & MAINTENANCE INSTRUCTIONS

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

AIR COMPRESSOR OPERATING & MAINTENANCE INSTRUCTIONS GC0511. Model No: PIONEER 220. Part Nos: (230V) & (110V)

AIR INLINE METAL SHEAR

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

50L ENGINE DRIVEN AIR COMPRESSOR MODEL NO: XPPV11 & XPP15 RANGE

1/2 REVERSIBLE AIR DRILL

8-GAL PNEUMATIC OIL DISPENSER

OPERATING & MAINTENANCE INSTRUCTIONS

½ REVERSIBLE AIR RATCHET

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

AIR/OVER HYDRAULIC JACK 20 TON

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

G7S Hand Pump Owner s Manual

Retractable Hose Reel with 3/8" x 50' PVC Hose

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

MODEL NUMBER: AS18-2 USER GUIDE

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

STRAIGHT DIE GRINDER

AIR RATCHET WRENCH MODEL NO: CAT21B & CAT90 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC05/14

RANGER 64 AIR COMPRESSOR

OWNER S TECHNICAL MANUAL

Operating Procedure TITON SUBSEA BOLT TENSIONER

80 Litre Suction Oil Drainer

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

3/8" Dr. Air Butterfly Impact Wrench

ROUGHNECK II Pumpless Drain

BRONCO 2 OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

100L BELT DRIVEN AIR COMPRESSOR

AIR COMPRESSOR MODEL NO: CHAMP

2.5 & 5.0 GALLON PRESSURE TANKS

WARRIOR 30 & 60 AIR COMPRESSOR OPERATING & MAINTENANCE INSTRUCTIONS

DUAL ACTION AIR SANDER

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

PIONEER 215 AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

MODEL CAT108 (1/2 ) & CAT109

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Operating Instructions Part No

SPYDER 3 & 7 OIL FREE AIR COMPRESSOR. OPERATION & MAINTENANCE INSTRUCTIONS Serial/Batch No:...

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

LONG BED SANDER MODEL NO: CAT49 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0714

Installation, Operation, and Maintenance Manual

ANGLE DIE GRINDER SET

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Constant Pressure Crude Oil Container Model CPCCP

AIR IMPACT WRENCH MODEL NO: CAT81 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0614

DelVal Flow Controls Private limited

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

Manual Actuated Boiler Blowdown Valves

GAS BBQ 4 burner. instructions for. model no: BBQ10

Operating Instructions Model and Hydrostatic Test Pump

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Model: 43T. Bermad Pressure Relief Valve

FV Flash Vessel Installation and Maintenance Instructions

RANGER 46 AIR COMPRESSOR

OPERATING & MAINTENANCE INSTRUCTIONS

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Transcription:

PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09

INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service. GUARANTEE This product is guaranteed against faulty manufacture for a period of 2 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. ENVIRONMENTAL PROTECTION Do not dispose of this product with general household waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of appropriately. PARTS & SERVICING For parts & Servicing, please contact your nearest dealer, or CLARKE International, on one of the following numbers. PARTS & SERVICE TEL: 020 8988 400 PARTS & SERVICE FAX: 020 88 622 or e-mail as follows: PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com 2

OVERVIEW This Pressure Testing Pump is primarily intended for the pressure testing of new domestic heating installations prior to the connection to the boiler and for fault-finding of leaks and identifying air ingress problems on existing systems. It can also be used for quick and exact pressure testing of installations such as compressed air and refrigeration systems and small bore pipelines. However, it is unsuitable for testing gas systems since liquid must be used. When correctly connected to a pipeline/radiator network or complete central heating system, this hand operated unit is used to build up the required hydraulic pressure. The reservoir incorporates a filter to prevent dirt entering the system under test and the gauge is shielded to prevent damage.. Outlet Pressure Hose (to system) 2. Reservoir. Operating Handle 4. Pressure Relief Valve. Pressure Gauge 2 4 LIST OF CONTENTS When unpacking, check for damage and /or shortages etc. Any found should be reported to your CLARKE dealer where the appliance was originally purchased. This Pressure Testing Pump should include the following: x Pressure Testing Pump Assembly x Locking Pin & Chain 2 x Sealing Washers (O-rings) x High Pressure Hose x Instruction Manual (this document)

GENERAL SAFETY RULES As with all machinery, there are certain hazards involved with the use and operation of this equipment. Exercising caution will reduce the risk of personal injury.. ALWAYS thoroughly familiarise yourself with this unit and its operation, and follow all instructions in this manual. 2. ALWAYS ensure that the pump is properly positioned where necessary to prevent it from moving during operation, and that the immediate area surrounding the pump is kept clear.. ALWAYS use only replacement parts supplied by the manufacturer. The use of non standard parts could be hazardous. 4. ALWAYS ensure that any residual pressure has been relieved before perfoming any maintenance work on the unit.. ALWAYS use only piping, hose and fittings rated equal to or greater than the maximum PSI rating of the pump. 6. ALWAYS maintain the equipment in good /clean condition for the best/ safest performance.. ALWAYS wear eye protection when working with pressurised systems. 8. ALWAYS return any systems that has been sealed off for testing to their original state before the system can be used again. 9. ALWAYS wash your hands thoroughly after handling used oil. 0. NEVER exceed the recommended testing pressure for any water heating system or component within that system. NEVER use this pressure tester for tasks it is not designed to perform. 2 NEVER use this equipment if it is damaged. ALWAYS establish the correct testing pressure for the pipework/installation to be tested before attempting to pressurise the system. 4. NEVER allow children to use this machine.. NEVER attempt any repairs to this appliance. 6. NEVER throw away used oil with domestic refuse or flush down a sink or drain. Collect any old oil in a leakproof container and take it to you local waste disposal site.. When necessary, have your appliance repaired by a qualified person using identical replacement parts. This will ensure that the safety of the appliance is maintained. Please keep these instructions in a safe place for future reference. 4

USING THE TEST PUMP. If you are not a trained plumber or heating engineer, seek professional guidance on the correct use of this equipment in conjunction with the system to be tested. 2. Establish the correct test pressure for the installation to be tested by refering to the system specification and /or the manufacturer s recommendations.. Ensure the heating system is fully OFF before commencing testing. 4. Any system to be tested must be fully sealed off in order for the test pressure to build up. When testing is finished, the system must be returned to its original design state before it can be used again.. If the system includes pressure relief valves, these must be temporarily disabled if the system is to be tested at more than their pre-set relief pressure. After testing, the pressure relief valves must be re-activated. 6. The system to be tested must be fully filled with water throughout and the test pressure built up. BEFORE USE. Check the condition of the hose and ensure all connections are tight and secure. Remove the locking pin to allow full movement of the arm/pivot assembly. 2. Connect the pressure hose to the pump outlet and the other end to the system to be tested. A suitable point on the system will need to be chosen and if necessary, an adaptor used to connect the pump outlet hose to the fluid system.

. Ensure there is sufficient clean liquid in the reservoir to cover the inlet pipe and then close the pressure relief valve. 4. Pump the handle until the pressure gauge indicates the desired pressure has been reached. If the required pressure is exceeded, reduce it by twisting the release valve as required. Allow the unit to stabilise for -0 seconds.. If the system is free from leaks, the pressure shown on the gauge will not drop during the test period. If the pressure is being lost, there is a leak in the system and a visual inspection should be made to locate the leak. 6. After testing, open the relief valve to release all pressure and allow water to flow back into the reservoir before disconnecting the pump from the tested system and re-sealing the point of connection.. Where the system has been temporarily sealed for testing, ensure the system is returned to its original condition. PARTS DIAGRAM 6

PARTS LIST NO CODE DESCRIPTION Qty NO CODE DESCRIPTION Qty HTPTP000 2 HTPTP002 HTPTP000 4 HTPTP000 4 HTPTP000 6 HTPTP000 6 HTPTP000 8 HTPTP000 8 9 HTPTP000 9 0 HTPTP00 0 HTPTP00 2 HTPTP00 2 HTPTP00 4 HTPTP00 4 HANDLE GLOVE HTPTP00 HANDLE 6 HTPTP00 6 CIRCLIP 6 HTPTP00 DROP ARM 2 8 HTPTP00 8 SPINDL E 2 9 HTPTP00 9 AXLE 20 HTPTP002 0 PISTO N 2 HTPTP002 STEEL BALL 22 HTPTP002 2 AIRTIGHT GASKET 2 HTPTP002 CASTING BODY 24 HTPTP002 4 AIRTIGHT GASKET 2 HTPTP002 M6X20 SCREW 26 HTPTP002 6 COVER PLATE 2 HTPTP002 RELIEF VALVE 28 HTPTP002 8 O-RING SEAL CONNECTING TUBE PRESSURE GAUGE STEEL BALL SPRING SCREW PLUG O-RING SEAL OIL FILTE R OIL HOSE RESERVOIR M6x 6 SCREW PIN & CHAIN NUT O-RIN G 2 TECHNICAL SPECIFICATION G auge max 60 bar (80psi) Volume stroke 40 cm P ressure MPa (2psi) Reservoir capacity 0 L Dimensions (mm) 28 x 220 x 20 Weight kg Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice.