Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Similar documents
Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Model Description

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Vehicle and Engine Emissions Testing

Your local gas generation partner. Precision series Modular gas generation solution for GC.

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Your local gas generation partner. Precision series Modular gas generation solution for GC.

APPLICATION NOTE. GC Integrated Permeation Device

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Gases and welding distributors continue

HiQ laboratory gas generators.

Major Design Features

PE 2400 II CHN/S Operating Instructions Revised 05/29/2015 S.V.

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Rapid and Reliable Detection of Dissolved Gases in Water

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

ISO INTERNATIONAL STANDARD

6890 GC Site Preparation

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Application Note AN-107

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

CORESTA RECOMMENDED METHOD Nº 67

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Ultimate Performance in Gas Chromatography

High Pressure Asher HPA-S

EasyLine Continuous Gas Analyzers. So smart, they re simple

Micro Motion 3098 Gas Specific Gravity Meter

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

490 Micro GC Site Preparation Checklist

Discovery HP-TGA 75/750. Site Preparation Guide

Laser Gases and Support

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

LUMAZOTE T ECHNICAL BRO CHU RE

HumiSys HF High Flow RH Generator

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Potter Nitrogen Generators

Improve Process Reliability

Carrier Gases in Capillary GC

The instrument will process the samples one by one till all the samples have been cleaned up.

GASES PROCESS CHEMICAL SPECIALTY. Gases. Pure Gases & Gas Mixtures. VOC Mixtures EPA Protocols. Propane Methane Nitrogen Air Acetylene Propylene Argon

Retention Time Locking: Concepts and Applications. Application

Multiple Gas#5 GC configuration Jan 2016

CO 2 and O 2 scrubbers

FPG8601 Force Balanced Piston Gauge

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

INSTRUMENT INSTRUMENT YL INSTRUMENT

MILITARY SPECIFICATION POWDER, BLACK

Model EXAxt AV550G. Averaging Oxygen Analyzer

The Tekran Series 2600-IVS Difference!

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Generating Calibration Gas Standards

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Setting a New Standard in Flash Chromatography Performance

A New GC/MS System Designed for Helium Carrier Gas Conservation

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

The latest automotive systems require innovative leak test methods and fixturing.

Optimizing Gas Supply for Industrial Lasers

Drilling Efficiency Utilizing Coriolis Flow Technology


MMS Mercury Monitoring System for Natural Gas

Constant Pressure Inlet (CCN) Operator Manual

SF 6 Product Guide. Gas Analysis Instruments and Accessories

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Trifecta High-Pressure Systems

The Criticality of Cooling

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

ISO INTERNATIONAL STANDARD

CAPITAL CONTROLS SERIES NXT3000

AMT-Ex Dewpoint Transmitter

Agilent Flowmeter ADM1000

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Transcription:

Organic Elemental Analysis 2410 Series II Nitrogen Analyzer proven performance reliable results

PerkinElmer 2410 Series II Nitrogen Analyzer Advanced Combustion Method Q U I C K G L A N C E Advanced combustion design for handling virtually any type of sample Frontal Chromatography for simple, reliable and accurate measurements Unique, economical features such as CO 2 carrier gas, wake-up and gas saver The PerkinElmer 2410 Series II Nitrogen Analyzer measures nitrogen and/or protein in a wide range of materials by using an advanced combustion method. The instrument is easy-to-use with a self-contained microprocessor-controlled analyzer to deliver reliable results. Used primarily in the food and agricultural areas, the 2410 Series II replaces the time-consuming, multistepped Kjeldahl method of analyzing feeds, grains, cereals, dairy products, fish, meats, fruits, nuts, fertilizers, plant material, soils and sediments. Additional application areas are in the polymer and petroleum industries. When nitrogen is the heteroelement in a polymer blend, it is monitored for quality control purposes. In the energy area, nitrogen is monitored as a contaminant or as an indication of the amount of additive present. For virtually any material where the measurement of nitrogen and/or protein is important, the 2410 Series II will find a place in your laboratory testing. 2

Standard features Based on the classical Dumas method, the PerkinElmer 2410 Series II Nitrogen Analyzer employs the following design principals: Furnace. Operating temperatures in excess of 950 C. Combustion of sample occurs in pure oxygen environment. Isolation of Product Gases. Reduction of NO x to N 2. Nitrogen is separated from other combustion gases, including methane, by a gas chromatography column. Detection. Detection of nitrogen by a thermal conductivity detector (TCD). Detector response is automatically converted directly to weight percent nitrogen and/or protein. Calibration. Calibration is based on weight percent nitrogen in a single primary standard. The design meets the method requirements for the determination of nitrogen and/or protein by combustion as described in AOAC methods 990.03, 992.15, 992.23, 993.13 and 997.09, as well as applicable AOCS, AACC and ASBC methods. Reporting results At the end of the analysis, the 2410 Series II automatically prints the results. Results can be directly converted from percent nitrogen to percent protein using the operator selected protein conversion factor. Different protein conversion factors can be selected for each sample. Additionally the nitrogen and/or protein results may be corrected to user-selected moisture content. Automated sample averaging To accommodate the analysis of heterogeneous samples, the results of up to five samplings of a material can be averaged and reported as if it were performed as a single analysis. These features, and more are standard with the 2410 Series II.

Reliable, easy-to-use design Principle of operation With the PerkinElmer 2410 Series II Nitrogen Analyzer samples are combusted in a pure oxygen environment, with the resultant combustion gas measured in an automated fashion. The 2410 Series II system is comprised of four major zones: Combustion Zone Gas Control Zone Separation Zone Detection Zone In the Combustion Zone, samples encapsulated in tin are inserted automatically using an auto injector. In the presence of excess oxygen and combustion reagents, the samples are completely combusted. Oxides of nitrogen are reduced to elemental nitrogen, N 2. Users have the flexibility of optimizing static and dynamic combustion conditions to meet the specific sampling need of their laboratory. The product gas then passes through a water trap into the Gas Control Zone and is captured in the mixing chamber. Here, the gas is rapidly mixed for thorough homogenization and precisely maintained at controlled conditions of pressure, temperature and volume, which leads to highly reproducible results. After the homogenization of the product gas, the mixing chamber is depressurized through a column in the Separation Zone of the instrument. The separation approach used is a technique known as Frontal Chromatography. As the gas elutes, it is measured by a thermal conductivity detector in the Detection Zone of the analyzer. Since the measurement in this design is made as a steady-state, stepwise change, the variations associated with the quantification of peak signals as in other analyzers are eliminated. Automated Weighted Entry. Accurate weighing of samples is a prerequisite for organic elemental analysis since results are presented on a weight percent basis. To avoid transcription errors, the 2410 Series II provides automatic weight entry from the cost-effective PerkinElmer AD-6 Autobalance as well as other balances. Using proven PerkinElmer balance technology, the AD-6 ultra mircobalance provides exceptional resolution and accuracy for the best results. No Special Sample Preparation. Simply weigh your samples into one of the 2410 Series II sample capsules. It doesn't matter if you're analyzing solids or liquids, there are capsules to accommodate most sample types and sizes. Straightforward Operation. Place the encapsulated sample in the system and press the start key. For multiple samples, you can use the integrated 60-position autosampler for unattended operation. The 2410 Series II features multitasking operation. For improved laboratory efficiency, new samples may be added to the run sequence while a sample is being analyzed. www.perkinelmer.com 4

Highlights Operating gases Unlike conventional combustion analyzers, the PerkinElmer 2410 Series II Nitrogen Analyzer uses carbon dioxide as the carrier gas in place of the more expensive helium or oxygen gas. Moreover, the use of carbon dioxide as the carrier gas eliminates the need to remove carbon dioxide from the combustion products prior to the measurement of nitrogen. Therefore there are fewer scrubber traps to maintain. Optimized combustion flexibility for best performance Combustion is the most critical step to the success of the measurements and ultimately affects the accuracy and precision of the final result: the weight percent of nitrogen. The 2410 Series II provides advanced combustion conditions of temperature, time and available oxygen. The user has the flexibility to increase the sample s combustion time in the oxygen atmosphere as well as the amount of oxygen that is introduced allowing for complete combustion of virtually any type of sample. Gas Control Zone A unique mixing chamber ensures a thorough mechanical homogenization of the product gas under the controlled conditions of pressure, temperature and volume. The homogeneity is important in order to achieve the most precise results. In addition, results are independent of changes in barometric pressure because the product gas is controlled to constant conditions every run. Frontal chromatography for the highest reliability In the 2410 Series II, there is selective retention of the gases to produce a steady-state, stepwise signal rather than a peak signal. This technique allows for a simpler, more reliable and accurate determination of the combustion gas than other analyzers which use a peak separation method. Laboratory efficiency The 2410 Series II was designed with reliability and productivity in mind. The instrument is easy to maintain, convenient and offers you the peace of mind that your analyses will run smoothly. If you need the instrument to be ready at a predetermined time, use the system's unique wake-up routine. Simply program in the date and time you want the instrument to start up, equilibrate, purge, and even run blanks and calibration standards. This feature allows the system to be ready when you are. There is the complementary shutdown feature as well as a programmable gas saver which allows for the automatic reduction of the carrier gas flow rate when the analyzer is not in use. A 60-position autosampler allows unattended operation night or day. The autosampler design has been tested through millions of cycles, both in accelerated quality assurance testing, and most importantly, in labs like yours throughout the world. Diagnostic routines continuously monitor electronic and pneumatic components for proper operation and alert the operator in the rare event that a failure is encountered. The 2410 Series II design incorporates a minimum number of valves for a significant reduction in maintenance time and a patented manifold for increased reliability. Water must be removed from the combustion gases prior to the detection of nitrogen. To accomplish this, a unique material, Aquasorb, is used. It efficiently removes water, is noncaking, and can be regenerated. It produces consistent, reliable operation and further savings on reagents. Reusable stainless steel reaction tubes provide costsavings for your lab. All of these features, and more are standard with the PerkinElmer 2410 Series II. 5

2410 Series II Nitrogen Analyzer Special features Optimized combustion Gas Control Zone Diagnostics Wake-up Shutdown Gas saver Run counters Autosampler Multiple sample mode Advanced calculations Offers advanced combustion conditions for static and dynamic steps. Users optimize temperature, time and available oxygen. Controls pressure, temperature and volume of the product gases. Monitors electronic and pneumatic components, continuously, assuring best instrument performance. Allows automatic instrument startup, equilibration and calibration at any operator-selected time and date. Allows for the automatic reduction of operating temperatures at operator-selected time and date. Provides automatic reduction of carrier gas flow rate with a built-in valve at an operator-selected time and date. Aids in routine maintenance procedures and monitors reagent and expendable components. Pneumatic, gravity feed autoinjector with 60-position autosampler carousel. Additional samples may be added during automatic sequencing. Up to five samples may be run; the signals of each run are used to calculate the result which is reported as a single result. In this mode, larger sample sizes may be accommodated. Selectable protein determination, calculates results on dry basis, mixtures Automatic weight Eliminates transcription errors and simplifies operations through automatic transfer weight transfer transfer using a PerkinElmer AD-6 ultra microbalance or TLB 60. CO2 carrier gas Copper reagent reduction Cost effective, pre-heated carbon dioxide (99.995% pure) Allows for the reduction (with 5-8% H2 gas mixture) of the copper reagent for reuse at operator-selected time and date. Physical details Power requirements Bench space 100 VAC ±10% Width 61 cm (24 in) 120 VAC ±10% Depth 55 cm (22 in) 230 VAC ±10% Height 55 cm (22 in) Weight ±45 kg (100 lbs) Specifications Analysis time Sample size Resolution Analytical detector range 4 minutes up to 500 mgs, depending on sample type and matrix. Large samples are limited by the sample matrix and content (see Analytical Range). 1 µg (10 ppm) Measuring range 0.01%-100% Accuracy* 0.001-40.0 mgs total nitrogen content Within ±0.15% of respective theoretical values Precision* Within a standard deviation of < 0.15% *Based on primary standards including EDTA, nicotinic acid, tryptophan, and lysine*hcl. PerkinElmer Life and Analytical Sciences 710 Bridgeport Avenue Shelton, CT 06484-4794 USA Phone: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices 2006 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. PerkinElmer is a registered trademark of PerkinElmer, Inc. or its subsidiaries, in the United States and other countries. All other trademarks not owned by PerkinElmer, Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 007492_01 Printed in USA