Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4

Similar documents
Installation and Maintenance Manual. Compact Medical Gas Outlets

Installation and Maintenance Manual. Dual Medical Gas Outlets

Operation and Maintenance Manual for GENTEC Medical Gas Outlets

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Shut-Off Valves and Valve Boxes

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Installation & Maintenance Manual. C2 & C3 Manifolds

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

GM2 SERIES DOME BIAS AUTOMATIC MANIFOLD

Installation & Maintenance Manual. Economy Manifold

Installation Instructions for NP100 Series Nitrogen Control Panels

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Economy Manifold Alert -2. Installation and Maintenance Manual V1.6

AREA VALVE SERVICE UNITS

Pressure Dump Valve Service Kit for Series 2300 Units

Operating and Maintenance Manual. Flowmeter

V-24 OXYGEN LANCE VALVE

Pressure Dump Valve Service Kit for Series 3000 Units

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

TECHNICAL INSTRUCTIONS

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

Medical Gas Control Panel

Installation, Operation and Maintenance Manual for Back Pressure Regulator

CS150 CAP STAPLER OWNER S MANUAL

American Medical Gas Outlets

Technical Specification

Operation Manual Piston Sensed Gas Pressure Regulators

Booster Pump PB4-60 Replacement Kits

Model VR6 System. Installation, Operation & Maintenance

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Santa Fe Cycles Assembly Guide Introduction

PARTS, SERVICE & REPAIR BULLETIN

AUTOMATIC GAS MANIFOLD

Helium-Oxygen Blender

SERIES-O REGULATOR. Instructions for use

Protocol Switchover Station

Installation Instructions

MANUAL GAS MANIFOLDS

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

1800C and 1800C-HC Series Service Regulators

Pressure Balance Trim

Hydraulic Punch Drivers

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation and Maintenance Manual. Microprocessor Based Digital Manifold NFPA

INSTALLATION INSTRUCTIONS

600 / 600FC OWNER'S MANUAL

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Introduction. Table of Contents. Andersen Medical Gas 12 Place Lafitte Madisonville, LA

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

35 TON HYDRAULIC PUNCH WARNING

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10


INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Product Information News September 26, 2003

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

SCUBAPRO Repair Guide. S600-S550 Second Stages

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

Safety Policy Manual Policy No. 133

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

DK ton, Double-acting, Die-type Crimping Tool

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

RG1200 Service and Repair Manual

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

TECHNICAL DATA CAUTION

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

602 STRINGING MACHINE OWNER'S MANUAL

MAINTENANCE PROCEDURE FOR X 650

1700ESL Kamvalok Coupler

Anti-flood device Model B-1

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

PDY TON HYDRAULIC CRIMPING TOOL WARNING

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

12S 1st Stage. -Maintenance Procedure-

750 Cable Cutter INSTRUCTION MANUAL

Hydraulic Punch Drivers

INSTRUMENTATION VALVES

shutoff valves 900 Series psig Manual Shutoff Valves

Continental Industries TRANSITION FITTINGS or FAX Visit

4400 TwinHybrid Gas Seal

NHR-X-X Encore Feed Hoppers

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Hydraulic Piston Accumulators

Instruction Manual Updated 7/26/2011 Ver. 2.2

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation Instructions

Maintenance Manual. Note: This document is broken up into the following 6 sections of prescribed maintenance.

Operating Instructions Model and Hydrostatic Test Pump

Floor Drinking Systems

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

Transcription:

Installation and Maintenance Manual Medical Gas Outlets DISS, Ohmeda, Chemetron, Puritan-Bennett & Oxequip / MedStar Compatible Puritan-Bennett Compatible Chemetron Compatible Ohmeda Compatible DISS Oxequip/ MedStar Compatible w w w. a m i c o. c o m

Table of Contents Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4 Installation & Dimensions 5-7 Wall Outlet 5 Ceiling Outlet 6 Console Outlet 6 Ceiling Column Outlet 7 Service 8-13 Latch-Valve Assembly - DISS 8 Latch-Valve Assembly - Ohmeda (compatible) 9 Latch-Valve Assembly - Chemetron (compatible) 10 Latch-Valve Assembly - Puritan-Bennett (compatible) 11 Latch-Valve Assembly - Oxequip/MedStar (compatible) 12 Rough-In Assembly - Wall and Console 13 Model Numbers 14-16 Latch-Valve Assembly 14 Rough-In Assembly 15 Complete Outlets 16 Gas Indexing 17 Replacement Components 18-23 Latch-Valve Assembly - Ohmeda (compatible) 18 Latch-Valve Assembly - Chemetron (compatible) 19 Latch-Valve Assembly - DISS 20 Latch-Valve Assembly - Puritan-Bennett (compatible) 21 Latch-Valve Assembly - Oxequip/MedStar (compatible) 22 Rough-In Assembly - Wall and Console 23 2 Amico Corporation

Product Description The Amico Medical Gas outlet is composed of two separate modules: the Rough-in assembly and the Latch-valve assembly. The Rough-in assembly is the same for all types (DISS, Ohmeda, Chemetron, Puritan-Bennett or Oxequip/ MedStar), while the Latch-valve assembly determines what type of adapter the outlet will accept. The Rough-in assembly consists of a brass machined body that incorporates a spring loaded check assembly. A 1/2" [12.7 mm] OD copper pipe is silver brazed into the body for external pipeline connections. The brass body and pipe assembly are inserted into a gas specific plate. The wall outlets can be ganged together at 5" [127 mm] centers (see page 5). This makes for a finished assembly that looks like one complete panel of outlets. The Rough-in assembly has a color coded label on the copper pipe, so that the installer can easily identify the gas that the copper pipe should be connected to. The Rough-in assembly incorporates a check valve that allows the Latch valve assembly to be removed for service, without requiring the pipeline to be shut down. The Rough-in assembly has a DUAL pin gas specific indexing arrangement to prevent the wrong Latch valve assembly from being plugged into the Roughin assembly (see page 17). The Latch-valve assembly is manufactured in five different models: DISS, Quick connect Ohmeda compatible, Quick connect Chemetron compatible, Quick connect Puritan-Bennett compatible or Quick connect Oxequip/MedStar compatible. The DISS Latch-valve assembly is permanently riveted together, so that the gas specific components cannot be taken apart, to ensure they remain gas specific. All the servicing on the DISS outlet is done inside the connector. On the Quick connect models the connector plate can be removed for additional O-Ring servicing, but is still gas specific since the gas specific parts are permanently riveted together. The Latch-valve assembly consists of: a connector with an integral check valve, an indexing block complete with indexing pins, a color coded gas front plate and a chrome frame. The Latch-valve assembly is inserted into the Rough-in assembly and secured screws. CAUTION: DO NOT overtighten the Latch Valve Mounting screws! Distortion of the Latch valve can occur. The quick connect models are compatible with the Ohmeda Diamond, the Oxequip/MedStar, the Chemetron, and the Puritan-Bennett quick connect adapters. Only the corresponding type of adapters can be used with the quick connect outlets. The DISS outlet conforms to the CGA Pamphlet V-5 standards. Since the Rough-in assembly is the same for all models of Latch-valve assemblies, the outlet can easily be converted from one type to another by simply replacing the Latch-valve assembly. NOTE: For ceiling applications, only DISS outlets are recommended www.amico.com 3

Cleaning and Lubricating The Amico Outlets are factory cleaned for oxygen service. Exposed surfaces of the outlet may be cleaned with a mild detergent solution or wiped with a disinfectant commonly used in patient rooms, that is compatible with plastics, anodized aluminium and die cast zinc. Lubricate elastomer seals sparingly with a silicone lubricant that is oxygen compatible. DO NOT USE OIL. Inspection and Testing Medical Gas Outlets should be inspected periodically or at least once a year. The test should be in accordance with NFPA 99 Gas and Vacuum systems. Test for Leaks: Ensure that no leaks exists, with or without the adapter inserted. Test for Indexing: Only a mating gas specific adapter should insert smoothly into the outlet, latch and be retained. Test for Flow: Gas Outlets: 120 l/min (4.2 scfm) @ 345 kpa (50 PSI), maximum allowable pressure drop is 28 kpa (4 PSI). Nitrogen Outlet: 400 l/min (14.1 scfm) @ 1,250 kpa (180 PSI), maximum allowable pressure drop is 70 kpa (10 PSI). Vacuum Outlet: 30 l/min (1.1 scfm) @ 54 kpa (16 inhg), maximum allowable pressure drop is 13 kpa (4 inhg). Refer to the appropriate standards for the proper way of performing the flow test. Note: The Amico medical gas and vacuum outlets meet and exceed these requirements at the time of manufacture. However piping source capacity, sizing and restrictions may prevent outlets from attaining these values. 4 Amico Corporation

Installation and Dimensions Wall Outlets DISS, Ohmeda compatible, Chemetron compatible, Puritan-Bennett and Oxequip/MedStar compatible Inch [mm] When wall outlets are ganged together, ensure that they are 5" (127 mm) from center to center. DO NOT let the notches on the mounting plate pass the adjacent holes on the next mounting plate. 3/8 [10] 1-1/16 [27] 5 [127] 5 [127] 5 [127] 1 7/8 [48] 1/2 [12.7] O.D. (3/8 [10] 1/2 [12.7 ] O.D. (3/8 [9.5] nominal) type K copper nominal) pipe, type rotates K 360 copper for pipe, entry rotates from any 360 anglefor entry from any angle Wall thickness may Wall thickness vary may vary from from 3/8 to 1 [10 3/8 to 125] [ 10 to 25] 11-1/4 [286] YGEN OXYGEN Do not bury the outlet during the drywall and plaster application. Ensure that the cover over the outlet is in place until the Latch-valve assembly can be installed. 5-3/4 [146] 5 [127] 3 [76] OXY 5-27/32 [148] OXY NOTE: Amico recomends that you have a Amico recomends that you have a blank space blank between space outlets between and slides. outlets and slides. Maximum 3 outlets 3 outlets may may be ganged be ganged together together without additional support. without additional support. 5-1/2 [140] www.amico.com 5

OXY Installation and Dimensions Ceiling Outlets - DISS Inch [mm] When wall outlets are ganged together, ensure that they are 5" (127 mm) from center to center. DO NOT let the notches on the mounting plate pass the adjacent holes on the next mounting plate. 3/8 [10] 1-1/4 [32] 5 [127] 5 [127] 5 [127] 1-7/8 [48] Wall thickness may very may vary from 3/8 to 1 3/8 to 1 [10 to 25] [10 to 25] MEDVAC Do not bury the outlet during the drywall and plaster application. Ensure that the cover over the outlet is in place until the Latch-valve assembly can be installed. 5-3/4 [146] 5 [127] 3 [76] 5-27/32 [148] NOTE: Amico recomends that you have a blank Amico space recommends between that you outlets have a blank and space slides. between outlets and slides. Maximum Maximum 3 outlets 3 outlets may be may ganged be together ganged together without additional support. support. 5-1/2 [140] Console Outlets DISS, Ohmeda compatible, Chemetron compatible, Puritan-Bennett and Oxequip/MedStar compatible inch [mm] TOP VIEW 1/2 1/2 [12.7] [12.7] O.D. O.D. (3/8 (3/8 [10] nominal) type type K K copper pipe, rotates 360 360 for entry for entry from any angle. from any angle FRONT VIEW BACK ASSEMBLY FRONT VIEW FRONT ASSEMBLY SIDE VIEW 10-1/4 [260] OXYGEN SIDE VIEW FRONT ASSEMBLY 3-9/16 [91] 3-9/32 [83] 3-3/4 [95] OXY 1-13/16 [46] 2-7/16 [62] 2-7/16 [62] 6 Amico Corporation

Installation and Dimensions Ceiling Column Outlets DISS, Ohmeda compatible, Chemetron compatible, Puritan-Bennett and Oxequip/MedStar compatible inch [mm] 1/2 [12.7] 1/2 O.D. [12.7] (3/8 O.D. [9.5](3/8 nominal) [10] nominal) type K copper pipe, type rotates K copper 360 pipe, rotates 360 for entry from for entry any angle. from any angle 10-1/2 [267] FRONT VIEW BACK ASSEMBLY FRONT VIEW FRONT ASSEMBLY SIDE VIEW FRONT ASSEMBLY SIDE VIEW OXYGEN 3-9/16 [91] 3-9/32 [83] 3-3/4 [95] OXY OXY 1-13/16 [46] 2-7/16 [62] 2-7/16 [62] On all outlets (wall and console) the connecting pipe can swivel a full 360 for easy connection to the gas pipe. When soldering the pipe connection take care not to heat up the body, since that could damage the secondary check valve. It is very important to keep the protective cover/caps in place during construction, to ensure that no debris or dirt get into the outlet. When installing the Latch-valve assembly, remove the protective cover and inspect for dirt or debris in the outlet body. Clean out the contaminants, if required. The Latch-valve assembly should slide in smoothly into the Rough-In assembly, if not, check that there is no damages to the indexing pin arrangements. If the indexing pins are bent or damaged, replace the Latch-valve assembly. DO NOT PRESSURE TEST THE PIPELINE OVER 100 PSI [690 kpa] IF THE LATCH-VALVE ASSEMBLY HAS BEEN INSTALLED. All Rough-in assemblies can be pressure tested up to a maximum of 200 PSI without the Latch-valve assembly attached to it. All Latch-valve assemblies with the exception of Nitrogen DISS have a Maximum pressure rating of 100 PSI [690 kpa]. The Nitrogen DISS has a maximum pressure rating of 200 PSI [1,380 kpa]. After installation, perform the test on page 1. www.amico.com 7

Service Before performing any maintenance on the Outlet, the appropriate hospital maintenance or engineering personnel should be notified. The Latch-valve assembly can be removed without interrupting the service, but when servicing the Rough-In assembly the supply pressure has to be shut off. Latch Valve Assembly DISS 20 17 13 12 21 22 23 16 11 15 Note: Latch-Valve Assembly Model Numbers see Page 14 Complete Outlet Model Numbers see Page 16 Repair Kit Model Numbers see Page 20 1. Unscrew the two retaining screws (12) until the Latch Valve Assembly (11) can be removed from the outlet. 2. Remove the O-Ring seal (16) from the front and replace (NOTE: There is no O-Ring for Oxygen, Medical Air and Carbon Dioxide). 3. Remove the retaining ring (23) using appropriate pliers. Remove the valve stem (17), O-Ring seal (20), primary check valve (21) and spring (22). Inspect the items for wear or damage and replace if needed. Replace the O-Ring (20). 4. Re-install all internal components and lock in place with the retaining ring (23). 5. Re-install the Latch Valve Assembly into the outlet. Coat the connector (15) with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the retaining screws (12), DO NOT over tighten, as this could damage the Latch Valve. 6. Connect a gas specific adapter to the outlet. The connection should be smooth and hand tightening of the nut should be sufficient to allow the gas to flow without leakage. If not, replace the entire Latch Valve Assembly (11). 8 Amico Corporation

Latch Valve Assembly Ohmeda (Compatible) 23 22 21 20 19 18 17 13 12 24 25 Note: Latch-Valve Assembly Model Numbers see Page 14 USE NO OIL Complete Outlet Model Numbers see Page 16 11 14 15 16 Repair Kit Model Numbers see Page 18 1. Unscrew the two retaining screws (12) until the Latch Valve Assembly (11) can be removed from the outlet. 2. Remove the four screws (25) holding the connector retaining plate (24) in place. Remove the plate. 3. Remove the connector (17) from the valve assembly. 4. Remove the U-spring (14), inspect for wear or damage, re-install the U-spring. 5. Remove the flat washer (15) and connector O-Ring (16) from the front of the connector. Inspect the items for wear or damage and replace the O-Ring seal (16). 6. Remove the retaining ring (23) using appropriate pliers. Remove the dust cap (18), dust cap spring (19), O-Ring seal (20), primary check valve (21) and spring (22). Inspect the items for wear or damage and replace if needed. Replace the O-Ring (20). 7. Re-install all internal components and lock in place with retaining ring (23). Insert the Connector (17) into the gas specific body. Check that the U-Spring (14), flat washer (15) and O-Ring (16) are in place. Re-install the connector retaining plate (24) and secure with four screws (25), do not overtighten. 8. Re-install the Latch Valve Assembly into the outlet. Coat the connector (17) with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the retaining screws (12), DO NOT over tighten, as this could damage the Latch Valve. 9. Connect a gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not replace the entire Latch Valve Assembly (11). www.amico.com 9

Latch Valve Assembly Chemetron (Compatible) 17 18 19 20 21 22 23 24 25 12 US E NO OIL Note: Latch-Valve Assembly Model Numbers see Page 14 11 16 Complete Outlet Model Numbers see Page 16 Repair Kit Model Numbers see Page 19 1. Unscrew the three retaining screws (12) until the Latch Valve Assembly (11) can be removed from the outlet. 2. Remove the four screws (25) holding the connector retaining plate (24) in place. Remove the plate. 3. Remove the connector (17) from the valve assembly. 4. Remove the connector O-Ring (16) from the front of the connector. Inspect the items for wear or damage and replace the O-Ring seal (16). 5. Remove the retaining ring (23) using appropriate pliers. Remove the dust cap (18), dust cap spring (19), O-Ring seal (20), primary check valve (21) and spring (22). Inspect the items for wear or damage and replace if needed. Replace the O-Ring (20). 6. Re-install all internal components and lock in place with retaining ring (23). Insert the Connector (17) into the gas specific body. Check that the O-Ring (16) is in place. Re-install the connector retaining plate (24) and secure with four screws (25), do not overtighten. 7. Re-install the Latch Valve Assembly into the outlet. Coat the connector (17), with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the retaining screws (12), DO NOT over tighten, as this could damage the Latch Valve. 8. Connect a gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not replace the entire Latch Valve Assembly (11). 10 Amico Corporation

Latch Valve Assembly Puritan-Bennett (Compatible) 20 16 17 18 19 12 P R E S S TO R E LE S E R E LE S E TO P R E S S USE NO OIL Note: Latch-Valve Assembly Model Numbers see Page 14 14 15 Complete Outlet Model Numbers see Page 16 11 Repair Kit Model Numbers see Page 21 1. Unscrew the two retaining screws (12) until the Latch Valve Assembly (11) can be removed from the outlet. 2. Remove the two screws (20), holding the round retaining ring (19) in place. Remove the plate. 3. Remove the gas connector (18) from the valve assembly. 4. Remove the Body Seal (15) and Poppet (16) from the front of the Gas Connector (18). Inspect the items for wear or damage and replace the Body Seal (15). 5. Remove the Gas or Vacuum Spring (17), to inspect for wear or damage. Re-install the Gas or Vacuum Spring. 6. Re-install all internal components into the Gas Connector (18). Check that the Gas or Vacuum Spring (17), Body Seal (15) and Poppet (16) are in place. Re-install the round retaining plate (19) and secure with two screws (20), do not overtighten. 7. Re-install the Latch Valve Assembly into the outlet. Coat the connector (18) with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the retaining screws (12), DO NOT over tighten, as this could damage the Latch Valve. 8. Connect a gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not, replace the entire Latch Valve Assembly (11). www.amico.com 11

Latch Valve Assembly Oxequip/MEDSTAR (Compatible) 20 18 17 16 19 10 9 15 8 14 7 6 12 11 7 Note: Latch-Valve Assembly Model Numbers see Page 14 Complete Outlet Model Numbers see Page 16 Repair Kit Model Numbers see Page 22 1. Unscrew the two retaining screws (12) until the Latch Valve Assembly (11) can be removed from the outlet. 2. Locking Mechanism Repair Unscrewing the first screw (7) and remove item (6). Then unscrew the second set of screws (7), this will give you access to items (8), (9) and (10). Inspect all three items for wear or damage, replace if needed. 3. Outlet Gas Connector Repair. While holding the round retaining ring (19) in place, remove the two screws (20). Remove the retaining ring (19) and gas connector (18). Then remove the Body Seal (15), the Poppet (16) and the Gas or Vacuum Spring (17). Inspect for wear or damage, replace components if needed. Re-install the Gas or Vacuum Spring (17), the Poppet (16) and the Body Seal (15) into the gas connector (18). Re-install gas connector (18) and retaining plate (19), secure with two screws (20). DO NOT OVERTIGHTEN. 4. Re-install the Latch Valve Assembly into the outlet. Coat the connector (18) with a thin coat of Oxygen compatible silicone lubricant to aid insertion. Tighten down the retaining screws (12), DO NOT over tighten, as this could damage the Latch Valve. 5. Connect a gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not, replace the entire Latch Valve Assembly (11). 12 Amico Corporation

Rough-In Assembly Wall and Console OXYGEN 1 OXYGEN 2 Note: Rough-in Assembly Model Numbers see Page 15 Complete Outlet Model Numbers see Page 16 3 Repair Kit Model Numbers see Page 23 4 8 7 6 5 CAUTION: Ensure that the supply pressure is shut off before performing service. Inside the Rough-in assembly is a secondary check valve whose function is to shut off gas flow when the Latch-valve assembly is removed. This seat/seal also prevents leakage around the latch valve connector. As the secondary seal is only a static seal, it will rarely need replacement. However, if the seat/seal does need replacement, follow the following procedure: 1. Ensure that no pressure exists in the line by depressing the secondary check valve (5). 2. Remove the retaining ring (8) from the inside of the outlet body. Use a small screwdriver to pull the end of the ring towards the center and then pull the ring up and out. 3. Remove the washer (7), seat/seal (6), secondary check valve (5) and secondary check valve spring (4). Inspect items for wear or damage and replace the seat/seal (6). 4. Re-install the spring (4), secondary check valve (5), seat/seal (6) and the washer (7). Insert the retaining ring (8) into the slot and ensure that the whole ring is seated properly. 5. Turn on the pressure and check for leaks. Re-install the Latch Valve assembly and perform the inspection and test on page 1. www.amico.com 13

Model Numbers Latch-Valve Assemblies Gas Service DISS Wall Latch-valve assembly: English USA English ISO French ISO Oxygen O-FASW-DI-U-OXY O-FASW-DI-E-OXY O-FASW-DI-F-OXY Medical Air O-FASW-DI-U-AIR O-FASW-DI-E-AIR O-FASW-DI-F-AIR MedVac O-FASW-DI-U-VAC O-FASW-DI-E-VAC O-FASW-DI-F-VAC Nitrous Oxide O-FASW-DI-E-N2O O-FASW-DI-E-N2O O-FASW-DI-F-N2O Nitrogen O-FASW-DI-E-NIT O-FASW-DI-E-NIT O-FASW-DI-F-NIT Carbon Dioxide O-FASW-DI-E-CO2 O-FASW-DI-E-CO2 O-FASW-DI-F-CO2 WAGD/AGSS O-FASW-DI-U-WAG O-FASW-DI-E-AGS O-FASW-DI-F-AGS DISS Console Latch Valve: For DISS Console Latch Valve replace the W in the O-FASW-DI-L-GAS to C. For example: USA DISS Oxygen = O-FASC-DI-U-OXY Ohmeda compatible Wall Latch Valve: For Ohmeda compatible Wall Latch Valve replace the DI in the O-FASW-DI-L-GAS to QD. For example: USA Ohmeda Vacuum = O-FASW-QD-U-VAC Ohmeda compatible Console Latch Valve: For Ohmeda compatible Console Latch Valve replace the W in the O-FASW-QD-L-GAS to C. For example: USA Oxygen = O-FASC-QD-U-OXY Chemetron compatible Latch Valve: For Chemetron compatible Wall Latch Valve replace the DI in the O-FASW-DI-L-GAS to CH. For example: Chemetron USA Vacuum = O-FASW-CH-U-VAC Chemetron compatible Console Latch Valve: For Chemetron compatible Console Latch Valve replace the W in the O-FASW-CH-L-GAS to C. For example: Chemetron USA Oxygen = O-FASC-CH-U-OXY Puritan-Bennett compatible Latch Valve: For Puritan-Bennett compatible Wall Latch Valve replace the DI in the O-FASW-DI-L-GAS to PB. For example: Puritan-Bennett USA Vacuum = O-FASW-PB-U-VAC Puritan-Bennett compatible Console Latch Valve: For Puritan-Bennett compatible Console Latch Valve replace the W in the O-FASW-PB-L-GAS to C. For example: Puritan-Bennett USA Oxygen = O-FASC-PB-U-OXY 14 Amico Corporation

Model Numbers Oxequip Compatible Latch Valve: For Oxequip compatible Wall Latch Valve replace the DI in the O-FASW-DI-L-GAS to OX. For Example: Oxequip USA Oxygen = O-FASW-OX-U-OXY Oxequip Compatible Console Latch Valve: For Oxequip compatible Console Latch Valve replace the W in the O-FASW-OX-L-GAS to C. For Example: Oxequip USA Oxygen = O-FASC-OX-U-OXY Rough-In Assemblies Gas Service Wall Rough-In: English USA English ISO French ISO Oxygen O-BAKW-U-OXY O-BAKW-E-OXY O-BAKW-E-OXY Medical Air O-BAKW-U-AIR O-BAKW-E-AIR O-BAKW-E-AIR MedVac O-BAKW-U-VAC O-BAKW-E-VAC O-BAKW-E-VAC Nitrous Oxide O-BAKW-E-N20 O-BAKW-E-N2O O-BAKW-E-N2O Nitrogen O-BAKW-E-NIT O-BAKW-E-NIT O-BAKW-E-NIT Carbon Dioxide O-BAKW-E-CO2 O-BAKW-E-CO2 O-BAKW-E-CO2 WAGD/AGSS O-BAKW-U-WAG O-BAKW-E-AGS O-BAKW-E-AGS Console Rough-In: For Console Rough-in replace the W in the O-BAKW-L-GAS to CON. For example: USA Oxygen = O-BAKCON-U-OXY Ceiling Rough-In: For Ceiling Rough-in replace the W in the O-BAKW-L-GAS to CEI. For example: USA Nitrogen = O-BAKCEI-E-NIT Ceiling Column Rough-In: For Ceiling Column Rough-in replace the W in the O-BAKW-L-GAS to CCOL. For example: USA Nitrous Oxide = O-BAKCCOL-E-N2O www.amico.com 15

Model Numbers Complete Outlets Gas Service DISS Wall: English USA English ISO French ISO Oxygen O-DISWAL-U-OXY O-DISWAL-E-OXY O-DISWAL-F-OXY Medical Air O-DISWAL-U-AIR O-DISWAL-E-AIR O-DISWAL-F-AIR MedVac O-DISWAL-U-VAC O-DISWAL-E-VAC O-DISWAL-F-VAC Nitrous Oxide O-DISWAL-E-N2O O-DISWAL-E-N2O O-DISWAL-F-N2O Nitrogen * O-DISWAL-E-NIT O-DISWAL-E-NIT O-DISWAL-F-NIT Carbon Dioxide ** O-DISWAL-E-CO2 O-DISWAL-E-CO2 O-DISWAL-F-CO2 WAGD/AGSS O-DISWAL-U-WAG O-DISWAL-E-AGS O-DISWAL-F-AGS * DISS Only ** Not Available for Puritan-Bennett DISS Console Outlet: For DISS Console outlet replace the WAL in the O-DISWAL-L-GAS to CON. For example: DISS Console USA Nitrogen = O-DISCON-E-NIT DISS Ceiling Outlet: For DISS Ceiling outlet replace the WAL in the O-DISWAL-L-GAS to CEI. For example: DISS Ceiling USA Nitrogen = O-DISCEI-E-NIT DISS Ceiling Column Outlet: For DISS Ceiling Column outlet replace the WAL in the O-DISWAL-L-GAS to CCOL. For example: DISS Ceiling Column USA Vacuum = O-DISCCOL-U-VAC Ohmeda compatible Outlet: For Ohmeda compatible outlet replace the DIS in any of the above examples, O-DISWAL-L-GAS to QD. For example: Ohmeda compatible Wall USA Oxygen = O-QDWAL-U-OXY Chemetron compatible Outlet: For Chemetron compatible outlet replace the DIS in any of the above examples, O-DISWAL-L-GAS to CH. For example: Chemetron compatible Console USA Oxygen = O-CHCON-U-OXY Puritan-Bennett compatible Outlet: For Puritan-Bennett compatible outlet replace the DIS in any of the above examples, O-DISWAL-L-GAS to PB. For example: Puritan-Bennett compatible Console USA Oxygen = O-PBCON-U-OXY Oxequip Compatible Outlet: For Oxequip compatible outlet replace the DIS in any of the above examples, O-DISWAL-L-GAS to OX. For Example: Oxequip compatible Wall USA Oxygen = O-OXWAL-U-OXY 16 Amico Corporation

Gas Indexing As seen from the front of the Rough-In Assemblies MEDVAC OXYGEN NITROUS OXIDE MEDICAL AIR NITROGEN CARBON DIOXIDE WAGD/AGSS www.amico.com 17

Replacement Components Latch Valve Assembly Ohmeda Compatible 12 13 17 18 19 20 21 22 23 24 25 USE NO OIL 11 14 15 16 26 Chrome face plate not supplied with console or column outlets Item Description 11 Ohmeda Latch-valve 12 Screw (2 Required) 13 O-Ring (2 Required) 14 Gas Connector U-Spring * 15 Flat Washer * 16 Gas Connector O-Ring * 17 Gas Connector 18 Primary Dust Cap 19 Primary Dust Cap Spring * 20 Primary Check Valve O-Ring * 21 Primary Check Valve * 22a Primary Check Valve Spring * 22b Primary Check Valve Spring-Vac * 23 C-Clip Primary Check Valve * 24 Connector Retaining Plate 25 Retaining Plate Screws (4 Required) 26 Chrome Face Plate Above parts with an * are found in repair kit: O-RK-LVA-QD, not sold individually. 18 Amico Corporation

Replacement Components Latch Valve Assembly Chemetron Compatible 13 17 18 19 20 21 22 23 24 25 26 12 U S E N O O I L 16 Chrome face plate not supplied with console or column outlets. 11 Item Description 11 Chemetron Latch-Valve 12 Screw (3 Required) 13 O-Ring (3 Required) 16 Gas Connector O-Ring * 17 Gas Connector 18 Primary Dust Cap 19 Primary Dust Cap Spring * 20 Primary Check Valve O-Ring * 21 Primary Check Valve * 22a Primary Check Valve Spring * 22b Primary Check Valve Spring-Vac * 23 C-Clip Primary Check Valve * 24 Connector Retaining Plate 25 Retaining Plate Screws (4 Required) 26 Chrome Face Plate Above parts with an * are found in repair kit: O-RK-LVA-QD, not sold individually. www.amico.com 19

Replacement Components Latch Valve Assembly DISS 12 13 17 20 21 22 23 16 26 11 Chrome face plate not supplied with console or column outlets Item Description 11 DISS Latch-Valve 12 Screw (2 Required) 13 O-Ring (2 Required) 16a Adapter O-Ring Nit * 16b Adapter O-Ring Vac * 16c Adapter O-Ring N2O * 17a Valve Stem DISS Gas 17b Valve Stem DISS Oxygen 17c Valve Stem DISS Vac & WAGD/AGSS 20 Primary Check Valve O-Ring * 21 Primary Check Valve * 22 Primary Check Valve Spring * 23 C-Clip Primary Check Valve * 26 Chrome Face Plate Above parts with an * are found in repair kit: O-RK-LVA-DIS, not sold individually. 20 Amico Corporation

Replacement Components Latch Valve Assembly Puritan-Bennett Compatible 24 21 15 16 17 23 12 P R E S S TO R E LE S E R E LE S E TO P R E S S Chrome face plate not supplied with console or column outlets USE NO OIL 13 14 11 Item Description 11 Puritan-Bennett Latch-Valve 12 Mounting Screw (2 Required) 13 O-Ring (2 Required) 14 Body Seal * 15 Poppet For Body * 16a Spring For All Gases (Except Vac.) * 16b Spring For Vacuum * 17 Gas Connector 21 Chrome Face Plate 23 Retaining Ring 24 Retaining Ring Screws (2 Required) Above parts with an * are found in repair kit: O-RK-LVA-PB, not sold individually. www.amico.com 21

Replacement Components 21 Latch Valve Assembly Oxequip/MEDSTAR Compatible 20 18 17 16 19 10 9 15 8 14 7 6 12 11 7 Item Description 6 Plastic Trimcap 7 #6 x 5/8" (15.9 mm) Screws 8 Cover Guide Plate ** 9 U-Spring ** 10 Cam Guide Plate ** 11 Oxequip Latch-valve 12 Mounting Screw (2 Required) 14 O-Ring (2 Required) 15 Body Seal * 16 Poppet For Body * 17a Spring For All gases (Except Vac) * 17b Spring For Vacuum * 18 Gas Connector 19 Retaining Ring 20 Retaining Ring Screws (2 Required) 21 Chrome Face Plate Above parts with * are found in repair kit: O-RK-LVA-OX-GC, not sold individually. Above parts with ** are found in repair kit: O-RK-LVA-OX-LM, not sold individually. Both O-RK-LVA-OX-GC and O-RK-LVA-OX-LM can be ordered as one kit using O-RK-LVA-OX 22 Amico Corporation

Replacement Components Rough-In Assembly OXYGEN 1 OXYGEN 2 3 4 8 7 6 5 Item Description 1 Rough-In Assembly 2 Gas Label ** 3 Screw (2 Required) 4 Secondary Check Valve Spring * 5 Secondary Check Valve * 6 Seat/Seal * 7 Washer * 8 Retaining Ring * Above parts with an * are found in repair kit: O-RK-BAK, not sold individually. ** L refers to language (U = For USA / E = For ISO) www.amico.com 23

www.amico.com Amico Corporation www.amico.com 85 Fulton Way, Richmond Hill Ontario, L4B 2N4, Canada Toll Free Tel: 1.877.462.6426 Toll Free Fax: 1.866.440.4986 Tel: 905.764.0800 C US LISTED Fax: 905.764.0862 Email: info@amico.com AP-INSTAL-MAINT-MEDGAS-OUTLETS 11.11.2015