TYPE APPROVAL CERTIFICATE

Similar documents
TYPE APPROVAL CERTIFICATE

SLOP RECEPTION AND PROCESSING FACILITIES

Assessment of Ships and Managers for the Acceptance of Extended Interval Between Bottom Surveys in Dry-Dock

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

N.I.V. Bluestar Plus

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

RULES FOR CLASSIFICATION Yachts. Part 5 Ship types Chapter 3 Passenger Yachts. Edition December 2015 DNV GL AS

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control

Electrical Shore Connections

CY LSOH Screened Halogen Free Control Cables with improved fire performance

RULES FOR CLASSIFICATION. Yachts. Part 5 Ship types Chapter 3 Passenger yachts. Edition October 2016 DNV GL AS

TYPE APPROVAL CERTIFICATE

Type MMV Medium Power Cable

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008

LNG BOIL-OFF RE-LIQUEFACTION PLANTS AND GAS COMBUSTION UNITS

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

HYDRAULIC CYLINDERS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2009

Semoflex Roboschlepp The PUR cable for cable chains

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

Halogen free cable. Halogen free cable

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

PURA. Pure Gas Dewpoint Transmitter. Users Guide

23.1 Functions, Basic Configuration, and Interfaces

M-06 Nitrogen Generator (Nitrogen Making Machine)

Part 7 Fleet in service Chapter 2 Inclining test and light weight check

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

Dynamic Positioning Systems

DT400/436 Tee Connector Installation Instructions

HV Spiker Kit - CSTE. 30 th April 2014

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

SILENT CLASS NOTATION

Pleasure Boat Inspection

Cable Accessories Contents Pg 64. Lighting Components Contents Pg 88. Cables Contents Pg 4 & 5. Lamps Contents Pg 95. Lightings Contents Pg 28

Sockets. terminations

Amphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment

Pressure controls for hydro carbons, zone II applications, Type KPE

Operating Instructions

7.0 Compliance certificates

Reliability Analysis Including External Failures for Low Demand Marine Systems

These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

RESOLUTION MSC.236(82) (adopted on 1 December 2006) ADOPTION OF AMENDMENTS TO THE GUIDELINES FOR THE TRANSPORT AND HANDLING OF LIMITED AMOUNTS OF

Chapter 16 - Protective Equipment

Pressure transmitters EMP 2

SMARTen STP Patch Cords Features

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

REQUIREMENTS FOR ONBOARD LIFTING APPLIANCES AND ANCHOR HANDLING WINCHES

To: Relevant departments of CCS Headquarters, Plan approval centers, CCS surveyors, relevant shipyards, designers and shipping companies

CMC Series Moulded Case Circuit Breaker Cielo Electric

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

REGULATION 22. STANDARD RELATING TO THE USE OF ARTIFICIAL RUGBY TURF

OFFSHORE. Trasfor OFFSHORE

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

VG5 Supplementary instructions

Ultima. X Series Gas Monitor

Pro-Tekt European Cable System. Technical Catalog

Metering Code Gas TSO, measurement by connected party Effective from to the present

ANNEX 15. RESOLUTION MEPC.158(55) Adopted on 13 October 2006

GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE

CAYMAN ISLANDS SHIPPING REGISTRY YACHT ENGAGED IN TRADE

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

Electronic Instrumentation

Status Date Prepared Reviewed Endorsed Approved

EASIDEW TRANSMITTER with Current Source Output

RESOLUTION MSC.397(95) (adopted on 11 June 2015) AMENDMENTS TO PART A OF THE SEAFARERS' TRAINING, CERTIFICATION AND WATCHKEEPING (STCW) CODE

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Stator Resistance Thermometers

Further technical information is available on

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

Hangt de baggerindustrie aan een (zijden) draadje

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired

Hollandse Kust (zuid) Wind resource assessment. 17 January 2017 Anthony Crockford

Guideline No.: L-01(201510) L-01 LIFEJACKETS. Issued date: October 20,2015. China Classification Society

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

ARC:Gear from Unipart Rail

Solar Sport One Notice of Race 2017 Version july, 2017

TYPE APPROVAL CERTIFICATE

This Procedure details the procedures to be followed in order to achieve Safety from the System when:

Arran LED Floodlight Luminaire

OTL Universal terminals

Progressive Safety Services LLC - All Rights Reserved

The IEC61508 Inspection and QA Engineer s hymn sheet

ARC:Gear from Unipart Rail

O&M MANUAL HIGHLIGHTS

The IEC61508 Project Manager's & Project Engineer's hymn sheet

F GENERAL RULES OF COMPETITION

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

Transcription:

<0> DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-11781 This is to certify that the Electric Power Cable with type designation(s) CS 90 MBZH YZp & & 0,6/1 kv, CS 90 MBZH YZafp 0,6/1 kv Manufactured by B.V. Twentsche Kabelfabriek HAAKSBERGEN, Netherlands is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC 60092-353 (2011-08) IEC 60332-3-22 (2009-02) IEC 60754-1/2 (2011-11) IEC 61034-2 (2005-04) Application General power and lighting. Flame retardant in buch Cat. A. Halogen free. Low smoke. Type Voltage class (kv) Temp. class ( C) CS 90 MBZH YZp & & 0,6/1 kv 0,6/1 90 CS 90 MBZH YZafp 0,6/1 kv 0,6/1 90 Høvik, 2012-07-03 for Det Norske Veritas AS This Certificate is valid until 2016-06-30 Marit Laumann Head of Section DNV local office: Rotterdam Ivar Bull Surveyor This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. Form No.: TA 1411a Issue: October 2009 Page 1 of 5

Product description Type: CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv Construction: Conductors: Plain or tinned stranded copper class 2, round or sector shaped or class 5 () Core insulation: XLPE Filler: Non hygroscopic tape or Halogen free filler ( and ) Outher sheath: SHF1 1 x 1 4,7 5,3-2 x 1 7,2 7,8-3 x 1 7,6 8,2-4 x 1 8,5 9,1-5 x 1 9,2 9,8-6 x 1 9,9 - - 7 x 1 9,9 - - 8 x 1 11,2 - - 9 x 1 12,1 - - 10 x 1 12,6 - - 11 x 1 12,6 - - 12 x 1 13,0 - - 13 x 1 13,6 - - 14 x 1 13,6 - - 15 x 1 14,6 - - 16 x 1 14,6 - - 17 x 1 15,3 - - 18 x 1 15,3 - - 19 x 1 15,3 - - 20 x 1 16,1 - - 21 x 1 16,1 - - 22 x 1 17,2 - - 23 x 1 17,2 - - 24 x 1 18,0 - - 25 x 1 18,0 - - 26 x 1 18,0 - - 27 x 1 18,4 - - 28 x 1 16,3 - - 29 x 1 19,0 - - 30 x 1 19,0-31 x 1 20,0 - - 32 x 1 20,0 - - 33 x 1 20,0 - - 34 x 1 20,7 - - 35 x 1 20,7 - - 36 x 1 20,7 - - 37 x 1 20,7 - - 1 x 1,5 5,0 5,6-2 x 1,5 7,8 8,6-3 x 1,5 8,2 9,0-4 x 1,5 9,2 9,8-5 x 1,5 10,0 10,6-6 x 1,5 10,8 - - 7 x 1,5 10,8 - - 8 x 1,5 12,3 - - 9 x 1,5 13,2 - - 10 x 1,5 14,0 - - 11 x 1,5 14,0 - - 12 x 1,5 14,4 - - 13 x 1,5 15,1 - - 14 x 1,5 15,1 - - 15 x 1,5 16,0 - - 16 x 1,5 16,0 - - 17 x 1,5 17,0 - - 18 x 1,5 17,0 - - 19 x 1,5 17,0 - - 20 x 1,5 17,9 - - 21 x 1,5 17,9 - - 22 x 1,5 18,9 - - 23 x 1,5 18,9 - - 24 x 1,5 20,0 - - 25 x 1,5 20,0 - - 26 x 1,5 20,0 - - 27 x 1,5 20,4 - - 28 x 1,5 18,1 - - 29 x 1,5 21,1 - - 30 x 1,5 21,1 - - 31 x 1,5 22,2 - - 32 x 1,5 22,2 - - 33 x 1,5 22,2 - - Form No.: TA 1411a Issue: October 2009 Page 2 of 5

34 x 1,5 23,0 - - 35 x 1,5 23,0 - - 36 x 1,5 23,0 - - 37 x 1,5 23,0 - - 1 x 2,5 5,4 6,0-2 x 2,5 8,8 9,4-3 x 2,5 9,3 9,9-4 x 2,5 10,1 10,7-5 x 2,5 11,2 11,8-6 x 2,5 12,2 - - 7 x 2,5 12,2 - - 8 x 2,5 13,6 - - 9 x 2,5 15,0 - - 10 x 2,5 15,6 - - 11 x 2,5 15,6 - - 12 x 2,5 16,1 - - 13 x 2,5 17,1 - - 14 x 2,5 17,1 - - 15 x 2,5 18,0 - - 16 x 2,5 18,0 - - 17 x 2,5 19,0 - - 18 x 2,5 19,0 - - 19 x 2,5 19,0 - - 20 x 2,5 20,3 - - 21 x 2,5 20,3 - - 22 x 2,5 21,3 - - 23 x 2,5 21,3 - - 24 x 2,5 22,6 - - 25 x 2,5 22,6 - - 26 x 2,5 22,6 - - 27 x 2,5 23,1 - - 28 x 2,5 20,5 - - 29 x 2,5 23,9 - - 30 x 2,5 23,9 - - 31 x 2,5 25,0 - - 32 x 2,5 25,0 - - 33 x 2,5 25,0 - - 34 x 2,5 26,0 - - 35 x 2,5 26,0 - - 36 x 2,5 26,0 - - 37 x 2,5 26,0 - - 1 x 4 5,9 6,5-2 x 4 9,8 10,4-3 x 4 10,4 11,2-4 x 4 11,6 12,2-5 x 4 12,6 13,2-1 x 6 6,4 7,0-2 x 6 10,8 11,6-3 x 6 11,7 12,3-4 x 6 12,8 13,4-5 x 6 14,1 14,7-1 x 10 7,2 7,8-2 x 10 12,6 13,2-3 x 10 13,4 14,2-4 x 10 14,9 15,5-5 x 10 16,3 17,1-1 x 16 8,1 8,9 9,9 2 x 16 14,6 15,2 16,9 3 x 16 15,5 16,1 17,8 4 x 16 17,3 17,9 19,6 5 x 16 18,9 19,7 21,2 1 x 25 9,8 10,4 11,6 2 x 25 17,8 18,4 20,1 3 x 25 19,0 19,8 21,3 4 x 25 21,1 21,7 23,4 5 x 25 23,4 24,0 25,7 1 x 35 10,9 11,7 12,7 2 x 35 20,2 20,8 22,5 3 x 35 21,6 22,4 23,9 4 x 35 24,0 24,8 26,3 5 x 35 26,6 27,4 28,9 1 x 50 12,6 13,2 14,9 2 x 50 23,4 24,0 25,7 3 x 50 25,2 25,8 27,5 4 x 50 28,0 28,6 30,3 5 x 50 31,0 31,6 33,3 1 x 70 14,4 15,0 16,7 2 x 70 26,8 27,6 29,1 3 x 70 28,9 29,5 31,2 4 x 70 32,1 32,9 34,4 5 x 70 35,7 36,3 38,5 1 x 95 16,0 16,8 18,3 2 x 95 30,4 31,0 32,5 3 x 95 32,5 33,3 34,8 4 x 95 36,3 36,9 39,1 5 x 95 40,2 41,0 43,0 1 x 120 17,8 18,4 20,1 2 x 120 33,8 34,4 36,6 3 x 120 36,4 37,0 39,2 4 x 120 40,4 41,2 43,2 5 x 120 45,0 45,6 47,8 1 x 150 19,8 20,4 22,1 Form No.: TA 1411a Issue: October 2009 Page 3 of 5

2 x 150 37,6 38,4 40,4 3 x 150 40,5 41,3 43,3 4 x 150 45,4 46,4 48,4 5 x 150 50,4 51,2 53,4 1 x 185 21,7 22,5 24,0 2 x 185 41,8 42,4 44,6 3 x 185 45,0 45,6 47,8 4 x 185 50,4 51,2 53,4 5 x 185 56,0 56,8 59,0 1 x 240 24,3 25,1 26,6 2 x 240 47,2 48,0 50,2 3 x 240 50,7 51,7 53,7 4 x 240 56,6 57,6 59,8 5 x 240 63,0 63,8 66,0 1 x 300 26,7 27,5 29,0 2 x 300 52,0 52,8 55,0 3 x 300 55,9 56,7 58,9 4 x 300 62,5 63,3 65,5 5 x 300 69,4 70,2 72,4 Type: CS 90 MBZH YZafp 0,6/1 kv: 2 1 x 1,5 5,6 2 x 1,5 8,6 3 x 1,5 9 4 x 1,5 9,8 5 x 1,5 10,6 6 x 1,5 11,6 7 x 1,5 11,6 8 x 1,5 12,9 9 x 1,5 14 10 x 1,5 14,6 11 x 1,5 14,6 12 x 1,5 15 13 x 1,5 15,7 14 x 1,5 15,7 15 x 1,5 16,8 16 x 1,5 16,8 17 x 1,5 17,6 18 x 1,5 17,6 19 x 1,5 17,6 20 x 1,5 18,5 2 21 x 1,5 18,5 22 x 1,5 19,7 23 x 1,5 19,7 24 x 1,5 20,6 25 x 1,5 20,6 26 x 1,5 20,6 27 x 1,5 21 30 x 1,5 21,7 32 x 1,5 22,8 37 x 1,5 23,6 1 x 2,5 6 2 x 2,5 9,4 3 x 2,5 9,9 4 x 2,5 10,7 5 x 2,5 11,8 6 x 2,5 12,8 7 x 2,5 12,8 8 x 2,5 14,4 9 x 2,5 15,6 10 x 2,5 16,2 2 11 x 2,5 16,2 12 x 2,5 16,9 13 x 2,5 17,7 14 x 2,5 17,7 15 x 2,5 18,6 16 x 2,5 18,6 17 x 2,5 19,8 18 x 2,5 19,8 19 x 2,5 19,8 20 x 2,5 20,9 21 x 2,5 20,9 22 x 2,5 22,1 23 x 2,5 22,1 24 x 2,5 23,2 25 x 2,5 23,2 26 x 2,5 23,2 27 x 2,5 23,7 30 x 2,5 24,7 32 x 2,5 25,6 37 x 2,5 26,6 Application/Limitation The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. Type Approval documentation Tests carried out Standard Release General description Limitation Form No.: TA 1411a Issue: October 2009 Page 4 of 5

Standard Release General description Limitation IEC 60092-350 2008-02 General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications IEC 60092-351 2004-04 Insulating materials for shipboard and offshore units, power, control, instrumentation, telecounication and data cables IEC 60092-353 2011-08 Electrical installations in ships - Part 353: Power cables for rated voltages 1kV and 3kV IEC 60092-359 1999-08 Sheathing materials for shipboard power and telecounication cables IEC 60332-3-22 2009-02 Flame retardance in bunch, cat. A IEC 60754-1 1994-01 Test on gases evolved during combustion of materials from cables Determination of the amount of halogen acid gas IEC 60754-2 1997-04 Test on gases evolved during combustion of materials from cables Determination of the degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and condctivity IEC 61034-1/2 2005-04 Measurement of smoke density of cables burning under defined conditions Test apparatus, procedure and requirements Low Halogen: <0,5% Halogen Halogen free: ph > 4,3 Conductivity < 10µS/ Light transmittance > 60% Marking of product TKF - Size - 0,6/1kV - CS 90 mbzh - YZp HALOGEN FREE - {batch nr} TKF - Size - 0,6/1kV - CS 90 mbzh - YZp 0,6/1kV HALOGEN FREE - {batch nr} TKF - Size - Class 5-0,6/1kV - CS 90 mbzh - YZp 0,6/1kV HALOGEN FREE - {batch nr} TKF - Size Class 5 - CS 90 mbzh - YZafp 0,6/1kV {batch nr} Certificate retention survey The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Survey to be performed at least every second year. END OF CERTIFICATE Form No.: TA 1411a Issue: October 2009 Page 5 of 5