Gaseous oxygen technical grade Specification

Public Assessment Report Scientific discussion. Lung test gas CO (He) AGA, 0.28%, inhalation gas, compressed (carbon monoxide, helium) SE/H/1154/01/MR

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

ISO 7941 First edition

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Experiment GC : Analysis of BTEX by GC-FID

System Overview. TCD Detector temperature setpoint Regulator

The analysis of complex multicomponent

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Multiple Gas#5 GC configuration Jan 2016

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Background Statement for SEMI Draft document 4657B NEW STANDARD: SPECIFICATIONS FOR TUNGSTEN HEXAFLUORIDE (WF 6 )

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

CORESTA RECOMMENDED METHOD Nº 67

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

800.Keen.Gas

LUMAZOTE T ECHNICAL BRO CHU RE

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

This GC has two columns (I think new columns can be ordered from Restek)

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Since the beginning of production of oil for transformers

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Rapid and Reliable Detection of Dissolved Gases in Water

Gases and welding distributors continue

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

Quantitative Analysis of Hydrocarbons by Gas Chromatography

HiQ laboratory gas generators.

The content of your gas cylinders. Pocket Safety Guide No. 1

Safety Data Sheet. Nitrous oxide. Version : see paragraph 16 "OTHER INFORMATION" see paragraph 16 "OTHER INFORMATION"

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

Niltox Breathing Air Purifier Range

Super-Clean Gas Filters from Restek

SAFETY DATA SHEET. CARBON DIOXIDE in non-refillable gas cylinders

APPLICATION NOTE. GC Integrated Permeation Device

Working in Gas Hazard Areas

REFINERY GAS ANALYSIS BY GAS CHROMATOGRAPHY

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

DURING the course of certain investigations it became

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

The Polyethylene Casing as Diffusion Barrier for Polyurethane Insulated District Heating Pipes

ONB/MHPQ/MDIS/ /Q22

ExamLearn.ie. The Air & Oxygen

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SRI Multi Gas Analyzer 2016

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Under pressure pushing down

OPERATING INSTRUCTIONS

Self-operated Pressure Regulators for special applications

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

High-purity gases. Customer-oriented offering highest quality

BASIC PHYSICS APPLIED TO ANAESTHESIOLOGY

Label 2.2: Non-flammable, Non-toxic gas 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

Cool - Headed Solutions

Class 2 Gases Learning Tool

Online DGA-monitoring of power transformers

Material Safety Data Sheet. FE-227 fire extinguishing agent

NITROGEN GENERATION FOR INDUSTRIAL APPLICATIONS

Cortisol Saliva ELISA

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

IT is frequently desirable to be able to determine the

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

MEDICAL GASES Manufacture, Storage, Transport & Delivery B.KIRUTHIGA LECTURER DEPT OF PHARMACEUTICAL CHEMISTRY

Anaesthesia. Update in. Gases and Vapours. Ben Gupta Correspondence Summary

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

MATERIAL SAFETY DATA SHEET May be used to comply with OSHA s Hazard Communication Standard 29 CFR

Zebron Gas Management

Safety Data Sheet. Ammonia. Version : 1.03

The right atmosphere for health. A system for medical gas supply

ISO INTERNATIONAL STANDARD

Gas Chromatographic Applications of the Dielectric Barrier Discharge Detector

LABELLING OF MEDICAL GAS CONTAINERS

DATA SHEET Revised edition no : 0. o óm MÁM M« : Industrial and professional. Perform risk assessment prior to use. Company identification

Applied Physics Topics 2

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

CHAPTER 5 : THE AIR AROUND US

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Transcription:

Svensk läkemedelsstandard 2017.2 Nitrous oxide Postadress/Postal address: P.O. Box 26, SE-751 03 Uppsala, SWEDEN Besöksadress/Visiting address: Dag Hammarskjölds väg 42, Uppsala Telefon/Phone: +46 (0)18 17 46 00 Fax: +46 (0)18 54 85 66 Internet: www.lakemedelsverket.se E-mail: registrator@mpa.se

Ansvarig utgivare: Svenska farmakopékommittén Läkemedelsverket Box 26 S-751 03 Uppsala, Sweden Tel. 018/17 46 00 2(6)

NITROUS OXIDE 1 Dinitrogenii oxidum N 2 O M r 44.01 [10024-97-2] DEFINITION Content: minimum 98.0 per cent V/V of N 2 O in the gaseous phase, when sampled at 15 C. This monograph applies to nitrous oxide for medicinal use. CHARACTERS Appearance: colourless gas. Solubility: at 20 C and at a pressure of 101 kpa, 1 volume dissolves in about 1.5 volumes of water. PRODUCTION Nitrous oxide is produced from ammonium nitrate by thermic decomposition. Examine the gaseous phase. If the test is performed on a cylinder, keep the cylinder at room temperature for at least 6 h before carrying out the tests. Keep the cylinder in the vertical position with the outlet valve uppermost. Carbon dioxide. Gas chromatography (2.2.28). Gas to be examined. The substance to be examined. Reference gas. A mixture containing 300 ppm V/V of carbon dioxide R1 in nitrous oxide R. Column: - material: stainless steel; - size: l = 3.5 m, Ø = 2 mm; - stationary phase: ethylvinylbenzene-divinylbenzene copolymer R. Carrier gas: helium for chromatography R. Flow rate: 15 ml/min. Temperature: - column: 40 C; 1 Kapitlet är hämtat från Ph Eur 9th Ed för information. I händelse av tvist gäller alltid det vid tillfället giltiga kapitlet i Ph Eur. 3(6)

- detector: 90 C. Detection: thermal conductivity. Injection: loop injector. Adjust the injected volumes and operating conditions so that the height of the peak due to carbon dioxide in the chromatogram obtained with the reference gas is at least 35 per cent of the full scale of the recorder. The test is not valid unless the chromatograms obtained show a clear separation of carbon dioxide from nitrous oxide. Limit: - carbon dioxide: not more than the area of the corresponding peak in the chromatogram obtained with the reference gas (300 ppm V/V). Carbon monoxide. Gas chromatography (2.2.28). When the test is carried out on a cylinder, use the first portion of gas to be withdrawn. Gas to be examined. The substance to be examined. Reference gas. A mixture containing 5 ppm V/V of carbon monoxide R in nitrous oxide R. Column: - material: stainless steel; - size: l = 2 m, Ø = 4 mm; - stationary phase: suitable molecular sieve for chromatography (0.5 nm). Carrier gas: helium for chromatography R. Flow rate: 60 ml/min. Temperature: - column: 50 C; - injection port and detector: 130 C. Detection: flame ionisation with methaniser. Injection: loop injector. Adjust the injected volumes and the operating conditions so that the height of the peak due to carbon monoxide in the chromatogram obtained with the reference gas is at least 35 per cent of the full scale of the recorder. Limit: - carbon monoxide: not more than the area of the corresponding peak in the chromatogram obtained with the reference gas (5 ppm V/V). 4(6)

Nitrogen monoxide and nitrogen dioxide: maximum 2 ppm V/V in total in the gaseous and liquid phases, determined using a chemiluminescence analyser (2.5.26). Gas to be examined. The substance to be examined. Reference gas (a). Nitrous oxide R. Reference gas (b). A mixture containing 2 ppm V/V of nitrogen monoxide R in nitrogen R1. Calibrate the apparatus and set the sensitivity using reference gases (a) and (b). Measure the content of nitrogen monoxide and nitrogen dioxide, separately examining the samples collected from the gaseous phase and the liquid phase of the gas to be examined. Multiply the result obtained by the quenching correction factor in order to correct the quenching effect on the analyser response caused by the nitrous oxide matrix effect. The quenching correction factor is determined by applying a known reference mixture of nitrogen monoxide in nitrous oxide and comparing the actual content with the content indicated by the analyser which has been calibrated with an NO/N 2 reference mixture. Quenching correction factor = actual nitrogen monooxide content indicated nitrogen monooxide content Water: maximum 67 ppm V/V, determined using an electrolytic hygrometer (2.5.28). Assay. Infrared analyser (2.5.35). Gas to be examined. The substance to be examined. It must be filtered to avoid stray light phenomena. Reference gas (a). Nitrous oxide R. Reference gas (b). A mixture containing 5.0 per cent V/V of nitrogen R1 and 95.0 per cent V/V of nitrous oxide R. Calibrate the apparatus and set the sensitivity using reference gases (a) and (b). Measure the content of nitrous oxide in the gas to be examined. IDENTIFICATION First identification: A. Second identification: B, C. A. It complies with the limits of the assay. B. Place a glowing splinter of wood in the substance to be examined. The splinter bursts into flame. C. Introduce the substance to be examined into alkaline pyrogallol solution R. A brown colour does not develop. 5(6)

TESTS Examine the gaseous phase. If the test is performed on a cylinder, keep the cylinder of the substance to be examined at room temperature for at least 6 h before carrying out the tests. Keep the cylinder in the vertical position with the outlet valve uppermost. Carbon dioxide: maximum 300 ppm V/V, determined using a carbon dioxide detector tube (2.1.6). Carbon monoxide: maximum 5 ppm V/V, determined using a carbon monoxide detector tube (2.1.6). When the test is carried out on a cylinder, use the first portion of the gas to be withdrawn. Nitrogen monoxide and nitrogen dioxide: maximum 2 ppm V/V, determined using a nitrogen monoxide and nitrogen dioxide detector tube (2.1.6). Water vapour: maximum 67 ppm V/V, determined using a water vapour detector tube (2.1.6). STORAGE Store liquefied under pressure in suitable containers complying with the legal regulations. The taps and valves are not greased or oiled. IMPURITIES Specified impurities: A, B, C, D, E. A. carbon dioxide, B. carbon monoxide, C. nitrogen monoxide, D. nitrogen dioxide, E. water 6(6)