For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Similar documents
Match Lit Fire Pit Insert MLFPK Series Installation & Operation Instructions

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

Toll Free: (877) Fax: (877) TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

127 / 460 Air Mixer and all FPSLPK Kits Installation & Operation Instructions

MATCH LIT FIRE PIT INSERT

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

JACKSON GRILLS PATIO FIRE

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

FPK Spark Ignition Safety Manual Installation & Operation Instructions. This Product is for use with Natural Gas Only.

PUSH-BUTTON / FLAME SENSING FIRE PIT INSERT

Match Lit Fire Pit Safety Manual Installation & Operation Instructions

WARNING: FOR OUTDOOR USE ONLY

Hearth Products Controls Co. 706 Congress Park Dr. Dayton, OH FPK Spark Ignition Safety Manual Installation & Operation Instructions

MATCH LIT FIRE PIT MANUAL INSTALLATION & OPERATION INSTRUCTION

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

INSTALLER: THIS MANUAL MUST BE LEFT WITH THE APPLIANCE. CONSUMER: KEEP THIS MANUAL FOR FUTURE REFERENCE. WARNING

OPERATING INSTRUCTIONS

Viking Installation Guide

ROBERT H. PETERSON CO.

INSTALLATION AND OPERATION INSTRUCTIONS

Owner s Manual for Assembly, Operating & Maintenance of

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

Installation and Operation Instructions

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Natural Gas Conversion Kit

OWNERS MANUAL WARNING WARNING WARNING WARNING WARNING WARNING DANGER. Series No.: Style No.: READ BEFORE USE!

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

GAS FRYER Instruction Manual Model #5099NS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

OCBE-34-01M (P) OUTDOOR CAMPFYRE ELECTRONIC SYSTEM WITH REMOTE CONTROL

INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

Robert H. Peterson Company

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Operating and Maintenance Instructions

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

AC POWERED ELECTRONIC PILOT KIT

ACCESSORY KIT INSTALLATION INSTRUCTIONS

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Propane Conversion Kit Instruction

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

Congratulations! Hand Held Torch. Warranty Policy PARTS

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

INSTALLATION INSTRUCTIONS

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Installation Instructions

for Assembly, Operating & Maintenance of Model Big 60 II Gas Utility Stove THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Owner's Manual and Instructions

Topanga Propane Fire Table Owner s Manual Small Round Style #

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

Your safety and the safety of others are very important.

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Propane Conversion Kit Instruction

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Installation Instructions

ASSEMBLY & OPERATING INSTRUCTIONS

Yoke Block Instruction Manual

USER S INFORMATION MANUAL

Topanga Propane Fire Table Owner s Manual Rectangle Style # /

for Assembly, Operating & Maintenance of THIS GAS GRILL IS DESIGNED FOR OUTDOOR USE ONLY.

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

User Manual 4 BURNER GAS GRILL Model number: GR OG-00 Ref. style: FSOGBG1106

ROBERT H. PETERSON CO. EPIC BURNER GAS LOG SET

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation, Operation and Maintenance Manual for Back Pressure Regulator

A Cover 1 B Burner Assembly 1 C 1/4 Table 4 D Angle Iron 4 E Back Bracket Post (Left) H Front Bracket Post (Right) 1 J K

ASSEMBLY & OPERATING INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

For outdoor use ONLY!

ACCESSORY KIT INSTALLATION MANUAL

MODELS. Premium Weave Rectangular Woven Table

for Assembly, Operating & Maintenance of THIS GAS GRIDDLE IS DESIGNED FOR OUTDOOR USE ONLY.

36H SERIES Combination Gas Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

Important: Retain these instructions for future use.

installation instructions

Yoke Block Instruction Manual


OUTDOOR PROPANE FIREPIT

Standard Gas Countertop Griddle

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

Types 749B and R130 Changeover Manifolds

SPECIFICATIONS CAPACITY

G45-2 STAINLESS STEEL BURNER FOR INDOOR OR OUTDOOR USE

INSTRUCTION MANUAL. Gas Salamander

1 Square = Foot/Feet Revision G 1/18/2013 Titan Controls

Transcription:

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping. Service We suggest that our products be serviced by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Specialists. Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. DANGER If you smell gas: 1) Shut off gas to appliance. 2) Extinguish any open flame. 3) If odor continues, keep away from appliance and immediately call gas supplier or fire department. Cylinders must be stored outdoors in a well ventilated area out of the reach of children. This appliance can only be stored indoors if it has been disconnected from its fuel supply. Before each use, inspect the fuel supply connections for leakage. Only the pressure regulator and hose assembly supplied with LP models is to be used. The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP gas cylinders as required by DOT. When an LP model is not in use, the LP gas must be turned off at the supply cylinder. The LP gas cylinder used must include a collar to protect the cylinder valve. 1

Index: 1) Parts List 2) General Information 3) Construction of LP Tank Enclosure 4) Warranty 5) Connecting kit to fire pit 1. Parts List STLPK Hose Assembly L-bracket for LP tank Installation and Operation Instructions INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 2. General Information Instructions are also available at hpcfire.com 3. Warranty Please carefully follow the instructions in this manual to prevent personal injury or property loss. Instructions are updated as needed. It is the installer s responsibility to periodically review instruction for applicable updates. These instructions contain information critical to the safe installation and operation of the fire pit. To qualify for warranty, instructions must be strictly followed. Warranty may be void if not followed. Never alter product or configuration in any way. IMPORTANT: It is the installer s responsibility to ensure a safe installation and to educate the end user as to proper operation. Leave this manual with the end user. We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping. We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Specialists or in Canada by WETT (Wood Energy Technical Training). Installer must follow all instructions carefully to ensure proper performance and safety. Hearth Products Controls Company is not responsible for your actions. It is the responsibility of the installer to follow: o The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel Gas Code. o Local Codes Only use gas/fuel type specified for fire pit refer to label on the fire pit control box. Never use an alternative fuel to include bio-fuel, ethanol, lighter fluid or any other fuel. Gas pressure and type should be checked prior to use and installation. o LP Gas: Supply Pressure: Minimum: 8.0 W.C.; Maximum: 11.0 W.C. BTU Maximum Fire Pit: 100K BTU Limited Warranty Hearth Products Controls Company (HPC) warranties fire pits against manufacturing defects that prevent safe and correct function as follows: STLPK Assembly 2 yrs. This commences from the date of original sale / shipment from HPC FOB Dayton, Ohio. This warranty is for parts and in-house (HPC) labor. The defective product must be sent back to HPC with a Return Merchandise Authorization (RMA) issued by HPC for that specific product and any other additional information for the nature of the defect or warranty claim. The warranty does not cover items that have been damaged by overheating, modification, abuse, or improper storage. Also any labor involving installation or maintenance with the unit is not covered. This warranty excludes claims for consequential, indirect-collateral expenses arising from product defects or warranty recovery. 2

4. Construction of the Remote LP Tank System Enclosure IMPORTANT: Only select models of Push Button / Match Lit (FPPK and MLFPK) fire pits are permissible for small tank use- please see HPC Product catalog, visit www.hpcfire.com or contact your HPC Dealer for details. IMPORTANT: Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage. For an enclosure using an LP tank system, follow these recommended specifications: You must follow local codes. IMPORTANT: The remote LP Tank / Enclosure should be a minimum of 36 from the fire pit. One side of the enclosure shall be completely open; OR For an enclosure having four sides, a top, and a bottom: o At least two ventilation openings shall be provided in the side walls of the enclosure, located within 5 in (127mm) of the top of the enclosure, equally sized, spaced at a minimum of 180 degrees, and unobstructed. The opening(s) shall have a total free area of not less than 1in 2 lb (14.2 cm 2 kg). See Figure 1. o Ventilation opening(s) shall be provided at floor level of the enclosure and shall have a total free area of not less than ½ in 2 /lb (7.1cm 2 /kg) of stored fuel capacity. If ventilation openings at floor level are in a side wall, there shall be at least two openings. The bottom of the openings shall be 1 in (25.4mm) or less from the floor level and the upper edge no more than 5 in (127mm) above the floor level. The openings shall be equally sized, spaced at a minimum of 180 degrees and unobstructed. See Figure 1. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 in (3.2mm) diameter rod. Ventilation openings in sidewalls shall not communicate directly with other enclosures of the appliance. LP Tank Size Top Opening Bottom Opening 20 LB (9.1 KG) 20 in 2 (130 cm 2 ) 10 in 2 (65 cm 2 ) 30 LB (13.6 KG) 30 in 2 (195 cm 2 ) 15 in 2 (100 cm 2 ) LP Tank Enclosure Specifications 2 Openings for each top and bottom - 180 o apart From LP tank base to bottom of opening - Max. 1" (25.4mm) From floor to base of LP tank - Min. 2" (50.8mm) Figure 1 The cylinder valve shall be readily accessible for hand operation. A door on the enclosure to gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools. Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a minimum of 180 degrees apart to facilitate lifting of the cover. The enclosure for the LP-gas cylinder shall isolate the cylinder from the burner compartment to provide: o Shielding from radiation; o A flame barrier; and o Protection from foreign material. There shall be a minimum clearance of 2 in (50.8mm) between the floor of the non-disposable LP-gas cylinder enclosure and the ground. The design of the enclosure shall be such that: o A non-disposable LP-gas cylinder can be connected, disconnected, and the connections inspected and tested outside the cylinder enclosure; and o Those connections which could be disturbed when installing the cylinder in the enclosure can be leak tested inside the enclosure. 3

Propane Cylinder: A worn cylinder may be hazardous and should be checked by your propane supplier. Never use a cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance with the specifications for LP gas cylinders of the National Standard of Canada, CAN/CSA B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or the Specifications for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). This appliance has been designed for use with a 20lb or 30lb size propane cylinder only (not supplied). The propane cylinder must be provided with a cylinder connection device compatible with the connection for outdoor appliances. The propane cylinder must be provided with a shut-off valve terminating in a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder shall include a collar to protect the cylinder valve. The cylinder shall incorporate listed OPD (overfill protection device). Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond 80 percent full. Use only the pressure regulator and hose assembly provided with this appliance. Replacement pressure regulators and hose assemblies must be specified by the manufacturer. The regulator supplies a pressure of 11 inches water column to the appliance and has a QCC1 type fitting. Cylinders to be used with this unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a positive seating connection, which will not allow gas to flow until a positive seal has been achieved. It is also equipped with an excess flow device. In order to attain full flow to the appliance, the valve must be in the off position when the cylinder valve is turned on. Locating the LP tank: : Failure to follow location and mounting guidelines for the LP tank could result in serious injury. : Locate the LP Tank and enclosure out of pathways where people may trip over it or in areas where the LP tank enclosure may be subject to accidental damage. Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage. Securing the LP tank: 1. Fasten the L-bracket to the bottom of the propane tank using the nut and bolt supplied. Ensure the nut is tight and will not loosen. 2. Select location for the propane tank following the guidelines above and screw the bracket to the mounting surface. For concrete surface, use a concrete anchor (not supplied). Ensure that screw is tight so that the cylinder cannot move. : Always ensure L-bracket is securely fastened to avoid tipping of LP tank. Cylinder Connection: Ensure the gas regulator has no kinks and is smooth. Remove the cap or plug from the cylinder fuel valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve and tighten until snug. Do not use tools. Leak test all joints prior to using the gas appliance. A leak test must be performed annually and each time a cylinder is hooked up or if a part of the gas system is replaced. Follow the instructions for natural gas hook-up if the appliance is to be connected directly to a house propane gas supply line. 5. Connecting kit to fire pit 1. Utilizing fitting connected to flex line, thread the NPT side to your fire pit with the use of approved thread sealant for gas. 2. Connect flex line to flare side of fitting that is now attached to your fire pit. (Do not use any thread sealant on flare threads.) 3. Ensure that connection to flare fitting is tight. 4. After installing your fire pit into your enclosure, run your STLPK hose to your LP tank. 5. Connect tank adapter (QCC1-quick connect) to your LP tank. 6. Ensure fire pit is turned off. 7. When all connections are assembled, slowly open the valve on your LP tank. 8. Check for any leaks using gas leak detector or soapy water. IMPORTANT: The propane cylinder is equipped with an excess flow device. If LP tank valve is opened quickly or fire pit is on before opening the tank valve, this may cause excess flow valve on the tank to close resulting in low flame height. Turn off fire pit and disconnect tank adapter (QCC1) and repeat connection steps. 4

5