State-of-the-art anesthesia technology

Similar documents
Your patients, our primary focus. Siesta i Whispa anesthesia machine

Dameca MRI 508. State-of-the-art MRI technology

Your patients, our primary focus

Siesta i Whispa Integrated technology

The centerpiece of a comprehensive anaesthesia workstation

An intuitive and innovative answer to your anaesthesia challenges

APUS Anesthesia Machines

APUS Anesthesia Machines

A9600 Anesthesia Workstation. Your healthcare, we care.

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Safe Accurate Reliable. CWM-301 Anesthesia System

Anesthesia Workstation

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Technical Data and Specifications

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

The anaesthesia workstation focused on you

SLE5000 Infant Ventilator with HFO

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Blease900 Ventilator PATIENT CENTERED VENTILATION

The anaesthesia workstation focused on you

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

GE Healthcare. Avance Carestation. Upgrade promotions guide

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

GE Healthcare. Aestiva/5. More than superior ventilation

V8800 Ventilator System. Your healthcare, we care.

Milestones of Aeonmed Ventilators

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

AkzentColor. Anesthesia. Anesthesia and excellent ventilation for neonatal, pediatric and adult patients

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

INTENSIVE CARE VENTILATORS

WILAmed INTENSA. Intensive Care Ventilator System

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

DATA SHEET. VENTILATION SERVO-s

D The specialist for every environment DRÄGER FABIUS TIRO

Carestation 620. Key Features. Ventilation. Design

Carestation 650c. Key Features. Design. Ventilation

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

Aespire 7100 Essential performance Compact design

HAMILTON-MR1. Technical specifications HAMILTON-MR1

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

fabian HFO: Modular, Powerful, Versatile.

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Carestation 650. Key Features. Design. Ventilation

SERVO-s v8.0 Data sheet

Flow meter. bellow vaporizer. APL valve. Scavenging system

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Oxylog 3000 plus Emergency & Transport Ventilation

Panther 5 Acute Care Ventilator

fabian HFO Our 4-in-1 device

Penlon MRI Product Range ANAESTHESIA SOLUTIONS

fabian Therapy evolution Our 2-in-1 device

Dräger Fabius Tiro Anaesthesia Workstations

D The plus that gives you more DRÄGER FABIUS PLUS

Intensa GO Alternate Care Ventilator

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

D The plus that makes all the difference DRÄGER FABIUS PLUS

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Intelligent Ventilation solution from ICU to MRI

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

SERVO-air ventilator. Datasheet for system version 2.1

Draeger Fabius GS Pre-Use Check

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

IEC C LASSIFICATIONS:

Airox Supportair Ventilator

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Anaesthesia Workstation. MODEL 7400A MODEL 7200A Glory Plus. Critical Care

Flight Medical presents the F60

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Apollo Safety Features

Dräger Fabius plus XL Anaesthesia Workstations

Dräger Fabius GS premium Anaesthesia Workstations

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

C O R P O R AT E B R O C H U R E

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Emergency Transport and Ventilation

Stephanie. Pediatrics. The ventilation system for neonatology

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Dräger Savina Sub-Acute Care Ventilation

Innovating with you Shaping exceptional care

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14

ekom Compressor for Medical Air Sonata with Ekom

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Infant Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

AV-S Ventilator. Service Manual. Partnership for Life. Remote Display Module and Interface for use with A200SP Absorber

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Transcription:

State-of-the-art anesthesia technology anesthesia system

Get closer to the MRI scanner Superb certified performance in close proximity to strong magnetic fields. Our innovative machine provides benefits in support of patient safety. MRI compatibility The has the unique ability to withstand up to 1000 Gauss and is 3.0 Tesla approved. Tests in cooperation with leading MRI scanner suppliers have confirmed that diagnostic images are undisturbed by the functioning anesthesia machine, and the machine is not affected by the MRI operation. For patients and hospital staff, the machine supports safety and comfort and saves time and space. Long lengths of tubing between the patient and the anesthesia machine are no longer necessary, reducing system compliance and allowing the operator to respond more quickly to patient needs. Continuous platform development Our commitment to ongoing innovation ensures our technological platform is continuously improved and aims to satisfy even the most demanding users. The benefits are many 2 Tested up to 1000 Gauss 3.0 Tesla approved Intuitive and user-friendly interface Integrated breathing system Microprocessor-controlled ventilator with seven advanced ventilation modes, including PRVT* 8" high-resolution color display High-level safety features Space-saving design User-friendly interface When not required in the scanner room, the Dameca MRI 508 can function as a conventional anesthesia machine in the operating theater. We have given it the same user interface and breathing system as our well-known Siesta i Whispa. Thus, no extra training is necessary to operate the so the operators can get to work right away. High-level safety features The has a number of built-in safety features, including: Improved audible and visual LED alarms for easy monitoring from the MR operating room Hypoxic guard function, ensuring at least 25% oxygen in the oxygen/nitrous oxide mix A slave regulator that cuts off nitrous oxide in the event of low oxygen flow A separate visual alarm will quickly alert the operator in the event of a failed oxygen supply A fresh-gas switch between the breathing system and the auxiliary gas outlet An oxygen flow meter with separate outlet, including tube nipple Adjustable integrated patient suction unit Semi-automatic self-test at start-up. In case of an emergency, the self-test can easily be bypassed Built-in battery backup (90 minutes) No drawers, eliminating the risk of magnetic materials being drawn away and forgotten 3

State-of-the-art MRI anesthesia technology Microprocessor-controlled ventilator Our ventilator compensates for changes in the freshgas flow and compliance in the breathing system. Pressure, spirometry data, and oxygen concentration are displayed on the 8 color TFT screen. Supports seven ventilation modes: VCV, PCV, SIMV, PSV, PRVT*, manual, and spontaneous. PRVT* Pressure Regulated Volume Target PRVT* (Pressure Regulated Volume Target), a lungprotective ventilation mode that combines the advantages of Volume Controlled Ventilation (VCV) and Pressure Controlled Ventilation (PCV). PRVT* continuously adjusts the inspiratory pressure based on the compliance and resistance of the patient s lungs and airways, to maintain pressure at the lowest possible level while providing the preset tidal volume. This provides optimum gas exchange and subsequent oxygenation during surgery. Space-saving design The slim, modular is a compact choice for all MRI suites, occupying a minimum of space. Twin wheels allow the machine to be moved around smoothly and easily. We have done our best to integrate all the key functions into the machine as standard. Even the AGSS for gas evacuation is among the core functions, eliminating the need for a separate system on the machine s side or rear. A backbar for mounting Selectatec vaporizers and simple mounting of all types of patient monitors adds to the flexibility of the the. 4 5

Integrated breathing system Forget about time-consuming, multiple-tube connections between the anesthesia machine, breathing system, and patient. Our integrated breathing system (IBS) integrates an ascending bag-in-bottle, patient circuit, and CO 2 absorber in one compact unit. That means no tubing between the breathing system and machine. Setting up for a procedure is fast, and cleaning is easy. In less than sixty seconds the breathing system can be taken apart for cleaning, without any need of special tools. The foolproof design prevents reassembly errors after cleaning. Bag-in-bottle The ascending bellows is designed to prevent air from being drawn into the breathing system in the event of a leakage. The capacity is up to 1500 ml, making it suitable for adults, pediatrics, and neonates. DAMECA MRI 508 Dimensions (H x W x D) Weight Hypoxic guard system Vaporizers Integrated breathing system (IBS) 1510 x 760 x 670 mm 110 kg Total flow range: 0 20 L/min Backbar for two Selectatec vaporizers (German or British standard) with interlock safety mechanism Vertical Insp./Exp. valve flaps Tool-free disassembly in less than sixty seconds Fresh gas introduced after Insp. valve Valves Vertical yellow valve flaps allow visual supervision of inspiration and expiration. An APL valve is also integrated and used in the manual and spontaneous modes. i-sorb absorber Available in reusable or disposable versions, i-sorb minimizes the waste of unused soda lime thanks to its flow-optimized design. Soda lime capacity is 900 g. The absorber can be replaced while the machine is in operation. Absorber capacity 900 g Ventilation modes VCV (volume-controlled ventilation) PCV (pressure-controlled ventilation) SIMV (synchronized intermittent mandatory ventilation) PSV (pressure support ventilation) PRVT* (pressure-regulated volume target) Manual, spontaneous Tidal volume 20 to 1500 ml Respiration rate 4 to 80 bpm I:E ratio 3:1 to 1:9,9 Electronic PEEP 4 to 20 hpa (cmh 2 Inspiratory pressure PCV 4 to 67 hpa (cmh 2 PSV 4 to 50 hpa (cmh 2 AGS System Ventilation measurements 30 to 40 L/min Peak, Plateau, and PEEP Pressure Patient compliance Tidal & minute volume Inspired O 2 %* Spirometry loop* incl. pressure waveform 6 7

Dameca_MRI508_brochure_Nov2016 Dameca A/S Islevdalvej 211 2610 Roedovre, Denmark Telefon +45 4450 9990 Fax +45 4450 9999 info@dameca.com www.dameca.com 2016 Dameca - reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.